CS1822 / CS4824 RS-232 Commands
2
Compliance Statements
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE
STATEMENT
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC ules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
The device complies with Part 15 of the FCC ules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC Caution
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.
Warning
Operation of this equipment in a residential environment could cause radio
interference.
Achtung
Der Gebrauch dieses Geräts in Wohnumgebung kann Funkstörungen
verursachen.
KCC Statement
CS1822 / CS4824 RS-232 Commands
3
Industr Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
HDMI Trademark Statement
The terms HDMI, HDMI High-Definition Multimedia Interface, and the
HDMI Logo are trademarks or registered trademarks of HDMI Licensing
Administrator, Inc.
RoHS
This product is oHS compliant.
CS1822 / CS4824 RS-232 Commands
4
RS-232 Operation
Overview
The CS1822 / CS1824’s built-in bi-directional S-232 serial interface allows
system control through a high-end controller or PC. S-232 serial operations
in a CS1822 / CS1824 installation are managed via HyperTerminal sessions on
systems that are running Windows. In order to use this feature to send
commands to the CS1822 / CS1824, you must first download and install a
HyperTerminal application. For detailed instructions and information about
each of the commands provided in this manual, please refer to the CS1822 /
CS1824 user manual.
Setup
Install a HyperTerminal application on a computer that is not part of the
installation, which will be used to control the switch via the S-232
connection. HyperTerminal applications can be download from the Internet,
and many operating systems are embedded with HyperTerminal applications.
Hardware Connection
Use a J-11 to DB-9 serial adapter (LIN5-04A2-J11G) to connect a
computer’s serial port to the serial port on the CS1822 / CS1824, as shown
below:
Note: The unit used in the diagram below is CS1824, the procedure for
connecting CS1822 is identical with fewer KVM ports.
RJ-11 to DB-9 Adapter
CS1822 / CS4824 RS-232 Commands
5
RS-232 Pin Assignments
Pin assignments for the CS1822 / CS1824’s rear J-11 Serial Port that is used
for connecting to a serial terminal are given in the table, below:
Note: This J-11 female connector is 4P4C.
Pin Assignment
1 TXD: Transmit Data
RJ-11 Female
2 RXD: Receive Data
3 N/A
4 GND: Si nal Ground
1 4
CS1822 / CS4824 RS-232 Commands
6
Console ogin - HyperTerminal
Once a physical connection from the computer to the CS1822 / CS1824 has
been made, you can establish a HyperTerminal session using the instructions
below.
1. Open the HyperTerminal application, and configure the port settings for
COM1 port, then click OK.
Bits per Second: 19200, Data Bits: 8, Parity: None, Stop bits: 1, Flow Control:
None.
2. After configuring the port settings you must enable serial control on the
switch by typing the command: Open + [Enter].
CS1822 / CS4824 RS-232 Commands
7
RS-232 Commands
After you login via HyperTerminal (see Console Login - HyperTerminal) use
the instructions below to send S-232 commands to control the switch from the
computer.
When S-232 control is enabled via the Open + [Enter] command, the
CS1822 / CS1824’s front panel pushbuttons, mouse switching and hotkeys will
be disabled, until the serial connection is closed.
For detailed information about the controls listed in this guide, please refer to
the CS1822 / CS1824 user manual.
Verification
After entering a command, a verification message appears, as shown below, at
the end of the command line, as follows:
With all commands in the sections that follow:
Each command string can be separated with a space.
The [Enter] command can be replaced with the ASCII code: 0x0D0A
Response Message Description
Command OK Command or parameter is correct.
Command incorrect Command or parameter is incorrect.
CS1822 / CS4824 RS-232 Commands
8
Open / Close
The Open and Close commands allows you to start and end the link between
the computer sending S-232 commands and the CS1822 / CS1824. When the
link is open, the CS1822 / CS1824 only accepts S-232 commands and will
not respond to front panel pushbuttons, mouse switching and hotkeys – until
the link is closed. The link starts with the open command and ends with the
close command or after 2 minutes if no command is sent. The default value is
close.
Use the Formula - to set Parameters - to create a Command.
Formulas:
Command + [Enter]
Parameters:
Open/Close RS-232 ink Command
The available formulas for the Open/Close S-232 Link commands are as
follows:
1. Command + [Enter]
For example, to open the S-232 link between the computer and CS1822 /
CS1824, type the following:
open [Enter]
2. Command + [Enter]
For example, to close the S-232 link between the computer and CS1822 /
CS1824, type the following:
close [Enter]
Command Description
open Open RS-232 Link command
close Close RS-232 Link command
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
9
Switch Port
The Switch Port command allows you to switch ports. The default port is 01.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Switch Port Commands
Some available formulas for the Switch Port commands are as follows:
1. Command + Control + [Enter]
For example, to switch to port 2, type the following:
sw i02 [Enter]
Note: The Control command can be skipped and the default value will be
used.
Command Description
sw Switch Port Command
Control Description
ixx Input Port Number
xx= 01~02 (CS1822) / 01~04 (CS1824)
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
10
Switch to Next Port
The Switch to Next Port command allows you to switch ports from 01~02 and
02~01 (CS1822); 01~02, 02~03, 03~04, and 04~01 (CS1824).
Note: This command is only supported by CS1822 / CS1824 using firmware
v. 1.1.101 or later.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + [Enter]
Parameters:
Switch to Next Port Command
The available formula for the Switch to Next Port command is as follows:
Command + [Enter]
For example, to switch to from port 1 to port 2, type the following:
sw [Enter]
Command Description
sw Switch Port Command
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
11
Switch Port (KVM Focus only)
The switch port command allows you to switch the KVM focus among
computers connected to the CS1822 / CS1824’s ports.
Note: This command is only supported by CS1822 / CS1824 using firmware
v. 1.1.101 or later.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Switch Port (KVM Focus only) Command
Some available formula for the Switch Port (KVM Focus only) command is as
follows:
Command + Control + [Enter]
For example, to switch the KVM focus to port 2, type the following:
sw i02 kvm [Enter]
Note: The Control command string can be skipped, and the default value will
be used.
Command Description
sw Switch Port Command
Control Description
ixx Input Port Number
x= 01~02 (CS1822); 01~04
(CS1824)
kvm Switch KVM focus only
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
12
Switch Port (USB Peripherals Focus only)
The switch port command allows you to switch the USB peripherals focus
among computers connected to the CS1822 / CS1824’s ports.
Note: This command is only supported by CS1822 / CS1824 using firmware
v. 1.1.101 or later.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Switch Port (USB Peripherals Focus only) Command
Some available formula for the Switch Port (USB Peripherals Focus only)
command is as follows:
Command + Control + [Enter]
For example, to switch the USB peripherals focus to port 2, type the following:
sw i02 usb [Enter]
Note: The Control command string can be skipped, and the default value will
be used.
Command Description
sw Switch Port Command
Control Description
ixx Input Port Number
x= 01~02 (CS1822); 01~04
(CS1824)
usb Switch USB peripherals focus
only
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
13
Switch Port (Audio Focus only)
The switch port command allows you to switch the audio focus among
computers connected to the CS1822 / CS1824’s ports.
Note: This command is only supported by CS1822 / CS1824 using firmware
v. 1.1.101 or later.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Switch Port (Audio Focus only) Commands
Some available formula for the Switch Port (Audio Focus only) command is as
follows:
Command + Control + [Enter]
For example, to switch the audio focus to port 2, type the following:
sw i02 audio [Enter]
Note: The Control command string can be skipped, and the default value will
be used.
Command Description
sw Switch Port Command
Control Description
ixx Input Port Number
x= 01~02 (CS1822); 01~04
(CS1824)
audio Switch audio focus only
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
14
Switch Port (KVM and USB Peripherals Focus)
The switch port command allows you to switch the KVM and USB peripherals
focus among computers connected to the CS1822 / CS1824’s ports.
Note: This command is only supported by CS1822 / CS1824 using firmware
v. 1.1.101 or later.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Switch Port (KVM and USB Peripherals Focus) Commands
Some available formula for the Switch Port (KVM and USB Peripherals
Focus) command is as follows:
Command + Control + [Enter]
For example, to switch the KVM and USB peripherals focus to port 2, type the
following:
sw i02 kvm usb [Enter]
Note: The Control command string can be skipped, and the default value will
be used.
Command Description
sw Switch Port Command
Control Description
ixx Input Port Number
x= 01~02 (CS1822); 01~04
(CS1824)
kvm usb Switch KVM and USB
peripherals focus
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
15
Switch Port (KVM and Audio Focus)
The switch port command allows you to switch the KVM and audio focus
among computers connected to the CS1822 / CS1824’s ports.
Note: This command is only supported by CS1822 / CS1824 using firmware
v. 1.1.101 or later.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Switch Port (KVM and Audio Focus) Commands
Some available formula for the Switch Port (KVM and Audio Focus)
command is as follows:
Command + Control + [Enter]
For example, to switch the KVM and audio focus to port 2, type the following:
sw i02 kvm audio [Enter]
Note: The Control command string can be skipped, and the default value will
be used.
Command Description
sw Switch Port Command
Control Description
ixx Input Port Number
x= 01~02 (CS1822); 01~04
(CS1824)
kvm audio Switch KVM and audio focus
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
16
Switch Port (USB Peripherals and Audio Focus)
The switch port command allows you to switch the USB peripherals and audio
focus among computers connected to the CS1822 / CS1824’s ports.
Note: This command is only supported by CS1822 / CS1824 using firmware
v. 1.1.101 or later.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Switch Port (USB Peripherals and Audio Focus) Commands
Some available formula for the Switch Port (USB Peripherals and Audio
Focus) command is as follows:
Command + Control + [Enter]
For example, to switch the USB peripherals and audio focus to port 2, type the
following:
sw i02 usb audio [Enter]
Note:The Control command string can be skipped, and the default value will
be used.
Command Description
sw Switch Port Command
Control Description
ixx Input Port Number
x= 01~02 (CS1822); 01~04
(CS1824)
usb audio Switch USB peripherals and
audio focus
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
17
Set Baud Rate
The Set Baud Rate command allows you to configure the baud rate setting for
the serial port connection. The default baud rate is 19200.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Set Baud Rate Commands
Some available formulas for the Set Baud ate commands are as follows:
1. Command + Control + [Enter]
For example, to set the baud rate to 19200, type the following:
baud 19200 [Enter]
2. Command + Control + [Enter]
For example, to set the baud rate to 38400, type the following:
baud 38400 [Enter]
Command Description
baud Baud Rate Command
Control Description
19200 Set baud rate to 19200 (Default)
38400 Set baud rate to 38400
9600 Set baud rate to 9600
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
18
Keyboard anguage ayout
The eyboard Language Layout command allows you to change the keyboard
language layout. The default language is English.
Use the Formula - to set Parameters - to create a Command.
Formula:
Command + Control + [Enter]
Parameters:
Keyboard anguage ayout Commands
Some available formulas for Keyboard Language Layout commands are as
follows:
1. Command + Control + [Enter]
For example, to change the keyboard language layout to Japanese, type the
following:
la out jp [Enter]
2. Command + Control + [Enter]
For example, to change the keyboard language layout to French, type the
following:
la out fr [Enter]
Command Description
layout Keyboard Lan ua e Layout Command
Control Description
en Chan e the keyboard lan ua e layout to
En lish (Default)
fr Chan e the keyboard lan ua e layout to
French
jp Chan e the keyboard lan ua e layout to
Japanese
e Chan e the keyboard lan ua e layout to
German
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
19
Hotkey Setting
The Hotkey Setting command allows you to change the hotkey used to invoke
the HSM (Hotkey Setting Mode). The default hotkey is [Num Lock] + [-].
Use the Formula - to set Parameters - to create a Command.
Formulas:
Command + Control + [Enter]
Parameters:
Hotkey Setting Commands
Some available formulas for Hotkey Setting commands are as follows:
1. Command + Control + [Enter]
For example, to change the HSM invoke key to [Num Lock] + [-], type the
following:
hotke num [Enter]
2. Command + Control + [Enter]
For example, to change the HSM invoke key to [Ctrl] + [F12], type the
following:
hotke f12 [Enter]
Command Description
hotkey Hotkey Settin Command
Control Description
num Chan e the HSM invoke key to:
[Num Lock] + [-] (Default)
f12 Chan e the HSM invoke key to:
[Ctrl] + [F12]
Enter Description
Enter Enter and send out command
CS1822 / CS4824 RS-232 Commands
20
Hotkey Switching
The Hotkey Switching command allows you to change the hotkey used for
switching. The default hotkey is [Scroll][Scroll].
Use the Formula - to set Parameters - to create a Command.
Formulas:
Command + Control + [Enter]
Parameters:
Hotkey Switching Commands
Some available formulas for Hotkey Switching commands are as follows:
1. Command + Control + [Enter]
For example, to change the hotkey switching mode to [Scroll] [Scroll], type the
following:
switch scroll [Enter]
2. Command + Control + [Enter]
For example, to change the hotkey switching mode to [Ctrl] [Ctrl], type the
following:
switch ctrl [Enter]
Command Description
switch Hotkey Switchin Command
Control Description
scroll Chan e hotkey switchin key to:
[Scroll] [Scroll] (Default)
ctrl Chan e hotkey switchin key to:
[Ctrl] [Ctrl]
Enter Description
Enter Enter and send out command

Other manuals for KVMP CS1822

3

This manual suits for next models

1

Other ATEN Switch manuals

ATEN CS1922M User manual

ATEN

ATEN CS1922M User manual

ATEN Bi-tronics Auto User manual

ATEN

ATEN Bi-tronics Auto User manual

ATEN Petite CS682 User manual

ATEN

ATEN Petite CS682 User manual

ATEN CL-1758L User manual

ATEN

ATEN CL-1758L User manual

ATEN CS1762a User manual

ATEN

ATEN CS1762a User manual

ATEN CM1164A User manual

ATEN

ATEN CM1164A User manual

ATEN AACS1208A User manual

ATEN

ATEN AACS1208A User manual

ATEN MASTER VIEW CS-92 User manual

ATEN

ATEN MASTER VIEW CS-92 User manual

ATEN Altusen KH1508a Operating and maintenance instructions

ATEN

ATEN Altusen KH1508a Operating and maintenance instructions

ATEN CS1922ATC User manual

ATEN

ATEN CS1922ATC User manual

ATEN Master View Slideaway ACS-1208AL User manual

ATEN

ATEN Master View Slideaway ACS-1208AL User manual

ATEN CS1768 User manual

ATEN

ATEN CS1768 User manual

ATEN KN1000A User manual

ATEN

ATEN KN1000A User manual

ATEN RCM101A User manual

ATEN

ATEN RCM101A User manual

ATEN Master View CS-9134 User manual

ATEN

ATEN Master View CS-9134 User manual

ATEN VS0801H User manual

ATEN

ATEN VS0801H User manual

ATEN ALTUSEN KL1508 User manual

ATEN

ATEN ALTUSEN KL1508 User manual

ATEN CS782DP User manual

ATEN

ATEN CS782DP User manual

ATEN CS52D User manual

ATEN

ATEN CS52D User manual

ATEN Petite CS62US User manual

ATEN

ATEN Petite CS62US User manual

ATEN CL6708MW User manual

ATEN

ATEN CL6708MW User manual

ATEN CS18208 User manual

ATEN

ATEN CS18208 User manual

ATEN Master View CS-1762 User manual

ATEN

ATEN Master View CS-1762 User manual

ATEN CM1284 User manual

ATEN

ATEN CM1284 User manual

Popular Switch manuals by other brands

Tekvox TEK 1201-MV user manual

Tekvox

Tekvox TEK 1201-MV user manual

Intellinet 560917 user manual

Intellinet

Intellinet 560917 user manual

Barco ScreenPRO-II user guide

Barco

Barco ScreenPRO-II user guide

D-Link DUB-H7 - Hub - USB Quick installation guide

D-Link

D-Link DUB-H7 - Hub - USB Quick installation guide

Owon SLC628 quick start guide

Owon

Owon SLC628 quick start guide

Data Video SE-1000 instruction manual

Data Video

Data Video SE-1000 instruction manual

Belkin F5U403 installation instructions

Belkin

Belkin F5U403 installation instructions

Yamaha EKS quick guide

Yamaha

Yamaha EKS quick guide

Orbis DICROMAT+ user manual

Orbis

Orbis DICROMAT+ user manual

Elko iNELS RFSA-61M quick start guide

Elko

Elko iNELS RFSA-61M quick start guide

Raritan Dominion KSX DKSX440 user manual

Raritan

Raritan Dominion KSX DKSX440 user manual

Edimax EK-082C Specifications

Edimax

Edimax EK-082C Specifications

Donner ABY BOX owner's manual

Donner

Donner ABY BOX owner's manual

ADDER CCS-PRO8 user guide

ADDER

ADDER CCS-PRO8 user guide

Minicom 0SU52015 owner's manual

Minicom

Minicom 0SU52015 owner's manual

ORiNG IGPS-1041GTA Quick install guide

ORiNG

ORiNG IGPS-1041GTA Quick install guide

Grasslin FM/1 digi 42 operating instructions

Grasslin

Grasslin FM/1 digi 42 operating instructions

Sollatek Voltshield AVS3P-0 user manual

Sollatek

Sollatek Voltshield AVS3P-0 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.