ATEQ D620 User manual

ATEQ D620
Quick Start Guide

D620.388.00_QS_UK_01
2/03
Table of contents
Safety advisory / Warranty
Good practices and safety instructions 5
Air quality requirements 6
Preamble
ATEQ D620, a universal flow meter 7
Flow rate test 8
Principle of a cycle 10
Your ATEQ D620
Front panel 11
Connectors on the back panel (with all options) 12
Power supply connectors 14
Digital links 15
Digital inputs/outputs 18
Pneumatic connectors 22
Pneumatics configuration 26
User interface
Overview 31
Keys 31
Display 32
Starting up
Power up 34
Preparing a Program 34
Modifying a parameter 35
Selecting a program 36
Starting and stopping current cycle 36

D620.388.00_QS_UK_01
3/03
User adjustments
Options of the menus 37
Specifications
Characteristics 42

D620.388.00_QS_UK_01
4/42
ATEQ - Measurement Solution, Global Leader.
ATEQ
15, rue des Dames, Z.I.
78340 LES CLAYES-SOUS-BOIS
FRANCE
ateq.com
T.: +33 1 30 80 1020
F.: +33 1 30 54 1100
ATEQ K.K.
3 – 41 ATEQ Building, Ikehata
Chiryu-city, Aichi-pref
JAPAN
ateq.co.jp
T.: +81 566-84-4670
F.: +81 566-84-4680
ATEQ China
98 Jian Peng Lu
Shanghai
CHINA
ateq.com.cn
T.: +86 21 6763 9508
F.: +86 21 6763 9528
ATEQ SYSTEMS ANALYSIS
TAIWAN CO., LTD.
NO. 3, LAN 223, San Jia Dong
Street
40642, TAICHUNG
TAIWAN
ateq.com.tw
T.: +886 4 2437 5278
F.: +886 4 2437 3675
ATEQ CORP.
35980 Industrial Road Suite L
Livonia MI 48150
UNITED STATES
atequsa.com
T.: +1 734-838-3100
F.: +1 734-838-0644
We continuously work on improving our products. This is why information contained in this
manual, the device and the technical specifications may be modified without prior notification.
Pictures and figures in this manual are non-contractual.

D620.388.00_QS_UK_01
5/42
Safety advisory / Warranty
GOOD PRACTICES AND SAFETY INSTRUCTIONS
Safety recommendations
If the device is supplied with 100/240VAC, it is mandatory to connect it to the ground with
a good link to the ground, to protect against electric hazard or electrocution.
It is dangerous to change the status of the outputs.
They can control power actuators or other equipment (mechanical, pneumatic, hydraulic,
electrical or other) which can cause serious personal injury and damage to surrounding material.
For safety and quality measurement reasons, it is important, before powering on the device,
to ensure that it is air supplied with a minimum operating pressure (0.6 MPa ± 15%).
Recommendations for the test environment
Keep the test area as clean as possible.
Recommendations for operators
ATEQ recommends that the operators who use the devices have training and a level of
qualification that correspond to the job to perform.
General recommendations
— Read the user manual before using the device.
— All electrical connections to the device must be equipped with safety systems (fuses,
circuit breakers, etc.) adapted to the needs and in accordance with the applicable
standards and rules.
— To avoid electromagnetic interference, electrical connections to the device must be
shorter than 2 meters.
— Power supply plug must be grounded.
— Disconnect the device from the mains before performing any maintenance work.
— Shut off the compressed air supply when working on the pneumatic assembly.
— Do not open a connected device.
— Avoid splashing water on the device.
ATEQ is at your disposal for any information concerning the use of the device under
maximum safety conditions.
We draw your attention to the fact that ATEQ cannot be held responsible for any
accident related to a misuse of the measuring instrument, the workstation or non-
compliance of the installation with safety rules.
In addition, ATEQ declines any responsibility for the calibration or the fitting of their
instruments that is not done by ATEQ.
ATEQ also declines any responsibility for any modification (program, mechanical or
electrical) of the device done without their written consent.

D620.388.00_QS_UK_01
6/42
AIR QUALITY REQUIREMENTS
The air supplied into the device must be clean and dry. Even though the device is provided
with a filter, the presence of dust, oil or impurities may cause malfunction.
Air quality requirements according to ISO standard 8573
The air must be clean and dry.
The presence of impurities, oil or humidity in the air may cause deterioration which will not
be covered by the warranty.
When the instrument is working in vacuum conditions, impurities must be prevented from
being drawn into its internal components.
For this purpose we strongly recommend that a suitable airtight filter is installed between
the part under test and the instrument.
ATEQ recommends the following characteristics for the air supplied into the device.
Air characteristics ISO standard 8573 class
Grain size and concentration 0.1 μm and 0.1 mg/m3 Class 1
Dew point under pressure - 40° dew Class 2
Maximum concentration of oil 0.01 mg/m3 Class 1
Recommended additional equipment
ATEQ recommends the installation of this additional equipment:
— Air dryer to provide dry air at less than - 40° dew point
— 25 micron and 1/100 micron double filter.

D620.388.00_QS_UK_01
7/42
Preamble
ATEQ D620, A UNIVERSAL FLOW METER
ATEQ D620 is a universal flow meter that measures flow rates through parts to test.
ATEQ D620 can memorise 128 different test programs.

D620.388.00_QS_UK_01
8/42
FLOW RATE TEST
The ATEQ D6 series can do direct or indirect measurements. In both cases, the flow meter
can also work in depressurization (option).
Measurement principle
When the fluid (gas) enters the device1, it moves through a calibrated flow tube2which
causes a drop in pressure. The pressure drop is measured by a differential pressure sensor3.
The pressure of the part under test 5 is measured by the sensor4.
1Device
2Calibrated flow tube
3Differential pressure sensor
4Pressure sensor
5Part under test
Direct measurement
Once the part is filled, the device measures the flow rate through the part.
The test pressure is applied to the device1 and then to the input of the part under test2.
1Device
2Part under test

D620.388.00_QS_UK_01
9/42
Indirect measurement
The indirect measurement (also called recovery mode or under bell) allows a considerable
gain in time as the flow which enters into the device is already stabilized.
The test pressure is first applied to the input of the part under test1and then to the
device2. The output of the device2is vented to the atmosphere.
This method allows to test the parts at a higher pressure test (up to 2 MPa).
1Part under test
2Device
Depending on the part type, it may be possible to use a bell (ex: shower head where it is
impossible to recover the flow other than through the use of a bell). This method can only be
used if the recovery of the flow is easy.

D620.388.00_QS_UK_01
10/42
PRINCIPLE OF A CYCLE
The measurement cycle is made of 4 main phases: fill, stabilization, test, dumping.
An additional Pressure auto zero phase0can be placed at the start or at the end of a cycle,
depending on the requirement of the operator.
Flow rate
(0) (1) (2) (4) (0)
Time
Cycle start Cycle end
(3)
0Pressure auto zero phase
1Fill phase
2Stabilization phase
3Test
4Dumping

D620.388.00_QS_UK_01
11/42
Your ATEQ D620
FRONT PANEL
The user interface is located on the front panel.
1Display
2Cycle keys
3Navigation keys
4USB connectors
For more information, refer to User interface.

D620.388.00_QS_UK_01
12/42
CONNECTORS ON THE BACK PANEL (WITH ALL OPTIONS)

D620.388.00_QS_UK_01
13/42
Ref Name Description
1J1 Analog outputs - pressure and flow (option)
2J5 Fieldbus connector
3J8* Extender (not operational)
4J10 Program selection extension connector (option)
5J12 Printer RS232 connector / Modbus (option) or Profibus (option)
6M1 External capillary option
7J13 Temperature probe connector (option for external capillary)
8PExternal back pressure connector (option)
9-Input connector to the air filter (valves or regulator air supply)
10 -0.6 MPa valves air supply input (1 MPa range) or vacuum input
11 TEST Capillary connector to connect to the part under test
12 -Regulator output (indirect mode or bypass option or external
capillary option)
13 -Pneumatic output for external bypass option
14 ATM Output capillary (indirect mode): has to be left to the atmosphere
15 BPneumatic output for external shut off option or B automatic
connector option
16 ATM Output to be left to the atmosphere
17 APneumatic output for external dump option or A automatic
connector option
18 ATM Output to be left to the atmosphere
19 -Air supply energy information
20 ATEQ Part number / Serial number
21 M2 External capillary connector (option)
22 -Ground
23 J11 Relay board connector (digital inputs/outputs and 24VDC-2A
power supply)
24 J9 Outputs code board connector (digital inputs/outputs)
25 J7 Connector for 24VDC-2A or 100/240VAC power supply
(according option provided)
26 J4* USB (not operational)
27 J3* Dry contact input for ERD test mode (option)
28 J6 Fieldbus connector
29 J2* Network (not operational)
* These connectors are not operational. They are provided for future development of our
devices.

D620.388.00_QS_UK_01
14/42
POWER SUPPLY CONNECTORS
The device can be connected to an external power supply (24VDC-2A) or provided with
an internal power supply (100/240VAC) (option).
External supply
24 V DC connector (J7)
The device can be connected to a 24VDC-2A power supply through a M12 4 pins type
connector.
Pin number Signal
1Not connected
2+ 24 V DC
3Not connected
4Ground: 0 V
24 V DC on the relay board connector (J11) (option)
The device can also be connected to a 24VDC-2A power supply through J11 connector
on the relay board.
Pin number Signal
2+ 24 V DC
4+ 24 V DC
16 Ground: 0 V
Apply 24 V DC to the pin2 or4.

D620.388.00_QS_UK_01
15/42
Internal supply only
100 / 240 V AC connector (J7) (option)
The device can be connected to a 100/240VAC power supply (option).
This connector has a ON/OFF button.
It is mandatory to connect the device to the ground with a good link to the ground, to protect
against electric hazard or electrocution.
1ON
0OFF
DIGITAL LINKS
PC USB connectors (on front face)
USB connectors can be used for connecting miscellaneous compatible USB devices.
The USB connectors are located under the rubber cover1(see figure).
1Rubber cover
2USB connector to PC
3USB connector to USB key
Do not connect two USB devices at the same time.
Do not use a cable longer than 2 m.
Push the rubber cover1 slightly forward for an easy access to USB connectors2 and3.
Only use this connection for temporary communication. Connection to a PC cannot be used
permanently because the communication can be disconnected by the PC.

D620.388.00_QS_UK_01
16/42
Printer RS232 connector / Modbus (option) or Profibus (option)
(J12)
RS232 - SubD 9 pins male connector (printer)
RS232 for printer, bar code reader, PC connection.
Pin number Signal
1Not used
2RXD data input
3TXD data input
4Not used
5Ground
6Not used
7RTS request to send
8CTS clear to send
9Not used
RS232 - SubD 9 pins female connector (Profibus) option
Profibus: SubD 9 pins female connector.
Pin number Signal
1PE (ground)
2Not used
3Data line A
4CNTR - A (repeater control
signal)
5DGND (logic ground)
6VP (supply)
7Not used
8Data line B
9Not used
Devicenet connectors (J5) (J6) (option)
M12 type connector - 5 pins male connector (J5) (Devicenet input)
For connection to others ATEQ devices.
Pin number Signal
1Drain
2V+
3V-
4CAN_H
5CAN_L

D620.388.00_QS_UK_01
17/42
M12 type connector - 5 pins female connector (J6) (Devicenet output)
For connection to others ATEQ devices.
Pin number Signal
1Drain
2V+
3V-
4CAN_H
5CAN_L
Profinet connectors (J5 + J6) (option)
M12D coded type connector - 4 pins female connector (J5 + J6)
Pin number Signal
1Ethernet Tx + (Transmit
Data+)
2Ethernet Rx + (Receive Data +)
3Ethernet Tx - (Transmit Data -)
4Ethernet Rx - (Receive Data -)

D620.388.00_QS_UK_01
18/42
Ethernet connector (J5 + J6) (option)
Standard connection Ethernet TCP / IP protocol.
One of these network protocols is available:
— Ethernet IP
— Profinet
— Ethercat.
DIGITAL INPUTS/OUTPUTS
The 24V DC power supply for the digital inputs can be provided by 2 means:
— The internal power supply of the device (0.3A max)
— An external power supply provided by the customer.
Inputs default mode is PNP. NPN mode is available on request.
Relay board connector (J11) (option)
Characteristics
— Inputs
• Activation: + 24 V DC.
— Outputs
• Dry contacts
• 60 V AC / DC max - 200 mA max.

D620.388.00_QS_UK_01
19/42
Pin number Inputs / outputs Description
1Input 1 RESET
2+ 24 V DC Common
3Input 2 START
4+ 24 V DC Common
5Input 3 Program selection
6Input 4 Program selection
7Input 5 Program selection
8Input 6 Program selection
9Input 7 Program selection (programmable input)
10 Output Common floating output
11 Output Pass part
12 Output High flow fail part
13 Output Low flow fail part
14 Output Warning
15 Output End of cycle
16 0 V Ground
The device can be energized through a theJ11 connector of the relay board (except if internal
supply option):
–0 V to the pin16
–24 V DC to the pin2 or4.
Program selection extension connector (J10) (option)
The J10 connector is an extension of the J11 connector that enables the selection of128
programs.
Characteristics
— Inputs
• Activation: + 24 V DC.
Pin number Inputs/outputs Description
I8 Input 8 Program selection from 33 to 64 (programmable
input)
I9 Input 9 Program selection from 65 to 128 (programmable
input)

D620.388.00_QS_UK_01
20/42
Program selection (J11 and J10)
The connectors J11 and J10 (option) enable you to select a program from digital inputs.
Combinations of connector pins to activate for program selection
Program
number
J11 J10
Pin 5
(input 3)
Pin 6
(input 4)
Pin 7
(input 53)
Pin 8
(input 6)
Pin 9
(input 7)
Pin 1
(input 8)
Pin 2
(input 9)
10000000
21000000
30100000
41100000
50010000
61010000
70110000
81110000
90001000
10 1001000
11 0101000
12 1101000
13 0011000
14 1011000
15 0111000
16 1111000
17 to 32 X* X X X 1 X X
33 to 64 XXXXX1X
65 to 128 XXXXXX1
*X is equal to 0 or 1 in function of the program number.
Table of contents
Other ATEQ Measuring Instrument manuals