REED R6001 User manual

www.REEDINSTRUMENTS.com
Thermo-
Hygrometer
Instruction
Manual
R6001
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

2
www.REEDINSTRUMENTS.com
Table of Contents
Introduction ................................................................................................ 2
Product Quality........................................................................................... 3
Safety ......................................................................................................... 3
Features...................................................................................................... 3
Specications..........................................................................................3-4
Included...................................................................................................... 4
Instrument Description ............................................................................... 4
Display Description .................................................................................... 5
Operating Instructions.............................................................................5-7
Unit of Measure Selection (Temperature)............................................... 5
Data Hold ............................................................................................... 5
Relative Function ................................................................................... 5
MAX/MIN Function ................................................................................ 6
Auto Power Off ...................................................................................... 6
Humidity Calibration Procedure..........................................................6-7
Restoring Factory Settings .................................................................... 7
Battery Replacement.................................................................................. 7
Accessories and Replacement Parts ......................................................... 7
Applications................................................................................................ 8
Product Care .............................................................................................. 8
Product Warranty ....................................................................................... 8
Product Disposal and Recycling ................................................................ 9
Product Support......................................................................................... 9
Introduction
Thank you for purchasing your R6001 Thermo-Hygrometer. Please read the
following instructions carefully before using your instrument. By following the
steps outlined in this manual your meter will provide years of reliable service.
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

3
www.REEDINSTRUMENTS.com
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
Never attempt to repair or modify your instrument. Dismantling your
product, other than for the purpose of replacing batteries, may cause
damage that will not be covered under the manufacturer's warranty.
Servicing should only be provided by an authorized service center.
Features
• Easy-to-use,intuitivedesign
• DualLCDreadoutdisplaystemperatureandhumidity
• Userselectable°F/°C
• HighSamplingRateof2.5times/sec
• Datahold,Min/MaxandRelativefunctions
• Lowbatteryindicatorandautoshut-off
Specifications
Temperature
MeasuringRange: -4to140°F(-20to60°C)
Accuracy: ±1.6°F(0.8°C)
Resolution: 0.1°F/°C
Humidity
MeasuringRange: 0to100%RH
Accuracy: ±3%RH
Resolution: 0.1%RH
General Specifications
Display: DualDisplay,LCD
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

4
www.REEDINSTRUMENTS.com
DataHold: Yes
Min: Yes
Max: Yes
RelativeFunction: Yes
SamplingRate: 2.5times/sec.
AutoShut-off: Yes(30mins/off)
LowBatteryIndicator: Yes
PowerSupply: 9Vbattery
ProductCertications: CE
OperatingTemperature: -4to140°F(-20to60°C)
StorageTemperature: 14to140°F(-10to60°C)
OperatingHumidityRange: 10to80%
Dimensions: 9.5x2.1x1.3"(240x54x34mm)
Weight: 6.4oz(180g)
Included
• CarryingCase
• Battery
Instrument Description
1. Sensor Protective Cap
2. LCDDisplay
3. Power Button
4. MAX/MINButton
5. Data Hold Button
6. Relative Function Button
7. UnitofMeasureButton
8. Battery Cover
1
2
3
4
5
6
78
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

5
www.REEDINSTRUMENTS.com
Display Description
Data Hold Indicator Relative Indicator
Humidity Measurement
Temperature Display
Unit Indicator
Minimum Indicator
Maximum Indicator
Low Battery Indicator
Auto Power Off Indicator
Indication de la fonction de
conservation de la lecture
Indication de l'unité de mesure
Indication de la valeur de lecture minimum
Indication de pile faible
Indication du mode d'arrêt automatique
Indication de la valeur de lecture maximum
Indication du mode de relativisation
Mesure d'humidit
é
Operating Instructions
PresstheON/OFFbuttontoturnthemeterONorOFF.
Unit of Measure Selection (Temperature)
When the meter is powered on press the °C/°F button to toggle between
Celsius and Fahrenheit.
Note:ThedefaultunitofmeasureisCelsius(°C).Themeterwillautomati-
cally save the last selected unit of measure when turned off.
Data Hold
Press the HOLD button to freeze the current reading on the display. Press
the button again to resume normal operation.
Note:WhentheDataHoldfunctionisenabledtheREL,MAX/MIN,and
°C/°Fbuttonsaredisabled.
Relative Function
Press the REL button to store the current measurement. The meter will
display the difference between any new measurement and the stored
measurement. Press the RELbuttonagaintoexitRelativeFunction
mode and resume normal operation.
continued...
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

6
www.REEDINSTRUMENTS.com
MAX/MIN Function
1.
Press the MAX/MINbuttontoaccessMaximumandMinimummodes.
2. When pressing the MAX/MINbuttononce,theMAXIndicatorwill
appearonthedisplay.Themaximumtemperatureandmaximum
humidity values are displayed and will automatically update when
newmaximumdatavaluesaremeasured.
3. Press the MAX/MINbuttonagainandtheMINindicatorappearson
the display. The minimum temperature and minimum humidity values
are displayed and will automatically update when new minimum data
values are measured.
4. Press the MAX/MINbuttonathirdtimeandboththeMAXandMIN
indicatorswillblinkcontinuously.TheMaximum&Minimumvalues
willautomaticallyupdateintheMax/Minmemorywhilethecurrent
temperature and humidity measurements are displayed. To view
theMax/MinmeasurementsduringthismodepresstheMAX/MIN
button at any time to toggle through stored measurements.
5. ToexitMAX/MINmodeandresumenormaloperation,pressandhold
the MAX/MIN button for two seconds.
Note:WheninMAX/MINmode,theRELand°C/°Fbuttonsaredisabled.
Auto Power Off
To preserve battery life, the meter is programmed to turn itself off after
30 minutes of inactivity. To disable this feature, press and hold the HOLD
button while powering on the meter. When the meter turns on, release both
buttons simultaneously. The Auto Power Off indicator will not appear on
the display, conrming this feature is now disabled. If the meter is turned
offthenbackon,the"AutoPowerOff"featurewillbeenabledagain.
Humidity Calibration Procedure
In order to calibrate the meter humidity calibration standards are required
(REEDR9933,R9975orR9980).Ifthemeterhasbeenexposedto
extremeconditionsorithasnotbeenusedinalongperiodoftimethe
meter should be calibrated by following steps 1 through 6 below.
1. Turn the meter off.
2.
PresstheHOLD,°C/°F,andpowerbuttonssimultaneouslyandrelease.
continued...
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

7
www.REEDINSTRUMENTS.com
3. WhentheLCDashes,pressthe REL button to enter calibration
mode.Thiswillbeindicatedby"CAL1"ontheLCD.
4.
Insertthetipofthemeterintothe33%RHHumidityCalibrationStandard
(REEDR9933)thenpresstheMAX/MIN button to start the adjustment.
The calibration adjustment will be conrmed by a long beep.
5.
Themeterwillthendisplay"CAL2"tocalibratethesecondcalibration
point.Insertthetipofthemeterintothe75%RHHumidityCalibration
Standard(REEDR9975)thenpressMAX/MIN button to start the adjust-
ment. The calibration adjustment will be conrmed by a long beep.
6. After both calibrations are complete, the meter will resume normal
operation.
Note: The calibration steps can be cancelled at any point by pressing the
ON/OFFbutton.
Restoring Factory Settings
1. Turn the meter off.
2.
PresstheHOLD,°C/°F,andpowerbuttonsimultaneously,thenrelease.
3. WhentheLCDashes,presstheMAX/MIN button to restore factory
default settings.
4. A long beep will conrm factory settings have been restored. The
meter will then resume normal operation.
Battery Replacement
When the low battery indicator appears on the display, the battery should be
replaced.Removethebatterycoveronthebackandinsertanew9Vbattery.
Accessories and Replacement Parts
CA-05A Soft Carrying Case
R993333%HumidityCalibrationStandard
R997575%HumidityCalibrationStandard
R998033%and75%HumidityCalibrationKit
Don't see your part listed here? For a complete list of all accessories and
replacement parts visit your product page on www.reedinstruments.com.
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

8
www.REEDINSTRUMENTS.com
Applications
• Environmentalstudies
• Fooddistribution
• HVAC/Rsysteminstallation
• Greenhousesandindustrialspaces
• Saunas
• Humidors
• Museums
• LabMonitoring
Product Care
Tokeepyourinstrumentingoodworkingorderwerecommendthefollowing:
• Storeyourproductinaclean,dryplace.
• Changethebatteryasneeded.
• Ifyourinstrumentisn'tbeingusedforaperiodofonemonthorlonger
please remove the battery.
• Cleanyourproductandaccessorieswithbiodegradablecleaner.Donot
spraythecleanerdirectlyontheinstrument.Useonexternalpartsonly.
Product Warranty
REED Instruments guarantees this instrument to be free of defects in
materialorworkmanshipforaperiodofone(1)yearfromdateofshipment.
During the warranty period, REED Instruments will repair or replace, at no
charge, products or parts of a product that proves to be defective because
of improper material or workmanship, under normal use and maintenance.
REED Instruments total liability is limited to repair or replacement of the
product. REED Instruments shall not be liable for damages to goods,
property, or persons due to improper use or through attempts to utilize
theinstrumentunderconditionswhichexceedthedesignedcapabilities.
In order to begin the warranty service process, please contact us by email
at 1-877-849-2127 or info@reedinstruments.com to discuss the claim and
determine the appropriate steps to process the warranty.
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

9
www.REEDINSTRUMENTS.com
Product Disposal and Recycling
Please follow local laws and regulations when disposing or recycling your
instrument.Yourproductcontainselectroniccomponentsandmustbe
disposed of separately from standard waste products.
Product Support
If you have any questions on your product, please contact your authorized
REED distributor or REED Instruments Customer Service by phone at
1-877-849-2127 or by email at info@reedinstruments.com.
Please visit www.REEDINSTRUMENTS.com for the most
up-to-date manuals, datasheets, product guides and software.
Product specifications subject to change without notice.
All rights reserved. Any unauthorized copying or reproduction of
this manual is strictly prohibited without prior written permission
from REED Instruments.
1.800.561.8187info@REED-Direct.ca REED-Direct.ca

www.REEDINSTRUMENTS.com
TEST & MEASURE
WITH CONFIDENCE
CHECK OUT OUR LATEST PRODUCTS!
1.800.561.8187info@REED-Direct.ca REED-Direct.ca
Other manuals for R6001
1
Table of contents
Other REED Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Vega
Vega VEGAPULS WL 61 operating instructions

Elcometer
Elcometer 224 user guide

International Light Technologies
International Light Technologies ILT710 Operation manual

Simex
Simex SRT-N118 user manual

Chadwick-Helmuth
Chadwick-Helmuth 8500C Operator's manual

Hanna Instruments
Hanna Instruments HI 8010 instruction manual