Table of Contents
FCC Information -------------------------------------------------------------------- 2
Safety and Environmental Precautions ------------------------------------------------ 2
1. Scope --------------------------------------------------------------------------------- 3
2. Unpacking ----------------------------------------------------------------------- 3
3. Battery Charge ---------------------------------------------------------------------- 3
4. Getting Started ----------------------------------------------------------------------- 4
5. Shutting Down Tester ------------------------------------------------------------------ 4
6. Turning the Screen On/Off ---------------------------------------------------------- 4
7. Connectors and Function Description -------------------------------------------- 4
8. Menus ---------------------------------------------------------------------- 5
9. Dimensions ---------------------------------------------------------------------- 12

2
FCC INFORMATION
This Equipment has been tested and found to comply with the limits for a ClassA digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at this own expense.
WARNING
[A shielded-type power cord is required in order to meet FCC emission limits and also to
prevent interference to the nearby radio and television reception. It is essential that only the
supplied power cord be used.]
[Use only shielded cables to connect I/O devices to this equipment.]
You are cautioned that changes or modifications not expressly approved by the party
responsible for compliance could void your authority to operate the equipment.
[ ]: depend on EUT condition.
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1)This device may not cause harmful interference.
(2)This device must accept any interference received; including interference that may
cause undesired operation.
SAFETY AND ENVIRONMENTAL PRECAUTIONS
1. Charging this unit only from the charger comes with the package.
2. Do not try to replace the battery which secured inside the cabinet.
3. Do not place this monitor near a radiator or heating vent.
4. Do not use monitor in wet areas, or where it may be exposed to rain or water. Do not
spill liquid of any kind on the unit.
5. Use only a damp cloth. Do not use alcohol, spirits, or ammonia to clean the display. DO
NOT ATTEMPT TO CLEAN THE INTERIOR OF THIS UNIT- THIS ACTION MUST BE
PERFORMED BY THE SERVICE TECHNICIAN AS REQUIRED DURING NORMAL
MAINTENANCE.
6. Refer all servicing to qualified service personnel. REMOVAL OF BACK COVER BY
UNAUTHORIZED PERSONNEL MAY EXPOSE THE USER TO DANGEROUS
VOLTAGES OR OTHER HAZARDS.
7. Stop using the unit immediately and notify the service technician.
A. If liquid has been spilled into the display or the display has been exposed to rain or
water.
B. If the unit has been dropped or the cabinet damaged.
C. If the battery life time extremely short.
D. If the charging time extremely long.
E. If a distinct change from normal operation is apparent.
When replacement parts are required, be sure that the service technician uses components
specified by the manufacturer which have the same characteristics as the original parts.
UNAUTHORIZED SUBSTITUTIONS MAY RESULT IN FIRE, OVER HEAT OR OTHER
HAZARDS. Upon completion of any service or repairs, ask the technician to perform safety
checks to determine that the equipment is in safe operating condition.
WARNING: DO NOT OPEN THE COVERS UNDER ANY CIRCUMSTANCES,
THERE ARE NO USER SERVICEABLE COMPONENTS INSIDE

3
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
Do not dispose of your device in a fire.
Do not throw your device in the trash.
Your device contains an internal lithium ion battery and it may require
recycling in accordance with local laws. Contact your local regulatory
authorities for more information.
This device is compliance with RoHS.
1. Scope
This specification is used to define the performance of ADE-043A IP Cam Test
Monitor. The Tester benefits users by providing various network protocol compatibilities.
The Tester also operates on both NTSC and PAL system by standard BNC video input.
IP Cam Tester is a versatile video tester for both analog and IP applications.
2. Unpacking
After you unpack your tester, make sure the following items are included in the box
and in good condition:
˙4.3” IP Cam Test Monitor
˙DC12V Adapter
˙Power Cord
˙BNC Cable
˙CAT5 Cable
˙UTP Terminal Block
˙Wrist Band
˙Carrying Bag
˙User’s Manual
˙Warranty Card
3. Battery Charge
Please connect the DC 12V adaptor to the DC jack to charge the battery pack on
the side of the Tester. While battery is charging, the power indicator LED-orange lit.
The LED will be off after the battery fully charged.
The Li-ion battery provided is able to support up to 3 hours of operating time with
PoE off, and takes approximately 6 hours to recharge.
WARRANTY VOID IF SEAL IS BROKEN

4
4. Getting Started
Press and hold the power key on the right edge for 2 seconds.
The Tester will start booting up then slide to to unlock the screen.
The START menu will come up, tap on START to proceed.
5. Shutting Down Tester
Press and hold the power key until [Power Off] prompted.
Tap [Power off] and [OK]
The Tester will automatically turn off in a few seconds.
If you cannot shut down your Tester as described above, press and hold the power
key for about 5 seconds to force it to shut down.
6. Turning the Screen On/Off (Sleep Mode)
You can turn off the screen (sleep mode) when you are not using your tester.
Press the power key.
The screen goes to sleep. To deactivate sleep mode and turn on the screen, press
the power key again
You can set the time until the screen automatically goes to sleep when the device
has not been operated for a given amount of time. Tap [Apps & Widgets] - [Settings] -
[Display] - [Sleep], and select the desired time interval before going to sleep
Note. If you will not use the Tester for a long time please turn off (shut down) it.
7. Connectors and Function Description
6 5 4 3 2 1
7
8
9
10
11
12
14 13

5
No.
Name
Connector
Function Description
1
Power Bank Switch
--
Switch ON to use external power bank (Optional).
Switch OFF to use internal battery.
2
PoE IN
RJ-45
Connect the LAN cable to the power bank (Optional).*
3
IP CAM
RJ-45
Connect the LAN cable to the IP camera.
4
Video IN
BNC
Connect the BNC cable to the camera’s video output.
5
Video OUT
BNC
Connect the BNC cable to a monitor.
6
Speaker
--
1W speaker.
7
Volume Keys
--
Adjust the Volume.
8
CAT5
RJ-45
For UTP cable test.
Connect one end of the network cable to this port and the
other end to the UTP Terminal Block.
9
DC 12V
DC Jack
Connect to the DC 12V adapter.
10
Power Key
--
Turn on/off the tester.
11
LED indicators
--
Power: Green - Power ON; Orange - Charge
PoE: Red - Internal battery;
Green - External power bank (Optional)
Link: Green - Ethernet active
12
4.3”OLED
--
4.3”OLED display with multi-touch screen.
13
USB Slot
USB A-type
Connect the USB storage devices to the USB slot for data
storage. (Format: FAT32)
14
MicroSD Slot
MicroSD
Insert the MicroSD card into the slot for data storage.
* WARNING: DO NOT CONNECT THE LAN CABLE CONTAINS POWER( PoE) TO
OTHER RJ-45 JACK, THE PERMANENT DAMAGE COULD HAPPEN AND RESULT IN
WARRANTY VOID.
8. Menus - Main menu
The Main Menu of IP Cam Test Monitor is shown as follows:
Section 1
Section 2

6
ICON
Description
Function
IPCAMSETTING
Setting and add IP Camera and connect to IP Camera.
SAVEFOLDER
Preview and manage the snapshot files.
Playback and manage the video files.
CAT5VIEWER
CAT5 Network Cable Test.
CVBSVIEWER
View analog camera connected to BNC connector.
PoE
PoE Function Enable or Disable.
CVBSOUTPUT
Output PAL and NTSC test patterns.
SETTING
Setting storage devices, folder and maximum recording
time.
INFORMATION
Tap this to get the Tester information.
EXIT
Exit CAMERA TESTER App.
RecentApps
Tap this to display the Apps used recently.
Home
Tap this to display the Home screen.
Back
Tap this to return to the previous screen.
IP CAM SETTING
˙Tap the “IP CAM SETTING”icon on the Main Menu to enter the submenu.

7
˙Tap “ADD”to add IP camera and enter the submenu.
˙DHCP off: Select DHCP On or Off(static IP)
˙Add: Add new camera
˙Camera Type: Select IP camera type.
˙Camera ID: Enter ID of the IP camera.
˙Login: Enter the user name of the IP camera.
˙Password: Enter the password of the IP camera.
˙IP: Set IP address for the IP camera.
˙Port: Set Port for the IP camera.
˙Channel: Set Channel for the data stream
˙Tap Screen to get video streaming.

8
˙Press to image snapshot and press to start video recording.
˙Tap “BACK”to return to the Main Menu.
*NOTE: Some of the camera brand does not support live snapshot and/or video recording
features, the icon will gray-out if it’s not supported.
SAVE FOLDER
˙Tap the “SAVE FOLDER”icon and select the saved file for preview.
˙Tap “BACK”to return to the Main Menu.
Manage the files
˙Press and hold the file name to enter the file operation submenu.
˙User can select the location to copy the file or delete it.
Preview the snapshot files
˙Tap the file name in the list to enter the Complete action using submenu.

9
˙User can select “ES Image Browser”or “Gallery”to view a image.
Playback the video files
˙Tap the file name in the list to view a video.
CAT5 VIEWER
˙Connect one end of the RJ-45 cable to the UTP Terminal Block and another end to
the CAT5 port at the right side of the Tester.
˙Tap the “CAT5 VIEWER”icon on the Main Menu.
˙Press the touch screen to start test.
˙Tap “PIN”to show RJ45 pin define.
˙Tap “BACK”to return to the Main Menu.
CVBS VIEWER
˙Connect the BNC cable from the video output connector of the Camera to the BNC IN
port on the Tester.
˙Tap the “CVBS VIEWER”icon and enter its setup page as shown below.
˙User can select aspect ratio 4:3 or 16:9 and view live video on the OLED screen.
PoE (Power over Ethernet)
˙Connect the Ethernet cable from the IP Camera to the IP CAM Port on top of the
Tester.
˙Tap the “PoE”icon and enter its setup page as shown below.

10
˙Tap the “PoE function”to enable or disable the PoE function.
CVBS OUTPUT
˙Connect the BNC cable from the video input of another monitor to the BNC OUT port
on the tester..
˙Tap the “CVBS OUTPUT”icon and enter its setup page as shown below.
˙Tap “CVBS output status”to enable CVBS output.
˙Tap “CVBS output mode”to select NTSC or PAL mode.
˙Tap “Enable and enter the pattern page”to enter the pattern page.
˙Tap “Pattern page”to enter the pattern page.
˙User can slide screen to change pattern.
˙Tap “Back”to exit pattern page.
Note. Pattern list:
0: 16 STEP / 1: 32 STEP / 2: LETTER / 3: COLOR BAR / 4: WINDOW1 / 5: RED /
6: GREEN / 7: BLUE / 8: WHITE / 9: BLACK
SETTING
˙Tap the “SETTING”icon and enter its setup page as shown below.
Section1
Section2

11
˙External storage devices: Select SD card or USB device.
˙Internal storage folder: Created folder named “Camera_Tester”. (User editable)
˙Maximum recording time: Select 15, 30, 60 or 120 seconds.
˙Icon hidden time: Select 5, 10, 20 or 30 seconds.
˙Sleep mode: Disable or Enable.
˙Tap “Back”to exit the setting page.
Note.When you need to remove the microSD card while the Tester is on, you must first unmount
the microSD card. This prevents corrupting the data stored on it or damaging the microSD
card. Close all running applications on your Tester and save any data before you unmount
the microSD card.To safely remove the microSD card on your Tester.
INFORMATION
˙Tap the “INFORMATION”icon on the Main Menu to get the tester information.
˙Tap “OK”to return to the Main Menu.
EXIT
˙Tap the “EXIT”icon on the Main Menu and press “YES”to exit CAMERATESTER App.
To restart the CAMERA TESTER, under desktop or in Apps page, tape on to
start the App.

12
9. DIMENSIONS

13
Page intentionally left blank

14
Page intentionally left blank

15
Atherton Electronics Corp.
www.athertonelectronics.com
29350 Hunco Way Ste. A, Lake Elsinore, CA 92530
© 2014 Atherton Electronics Corp. All rights reserved. 1-3121-1620G02
Table of contents