ATIGO A3101 User manual

1 | P a g e
2-Wire Video
System
Installation Manual

2 | P a g e
Introduction
The Atigo door entry system is a 2-Wire
system that can be expanded up to 4
entrance panels and up to 32 internal
monitors per system.
For programming camera module use built in
set of DIP switches and touch keys.
The camera module has built in visual and
audible status indictors as well as white LED
for night view.
Installation Notes:
Wire up the system in accordance with the
Wiring diagram supplied.
Make sure A2300 is installed next to the
Power supply when installing multiple
Entrances.
Set each Door Station ID as per instructions
on Page 3
Set the address for each handset by following
programming instructions supplied with the
unit.
System Layout:
Maximum of 4 monitors can be connected to
a single call button.
Maximum of 4 monitors can be connected in
daisy chain configuration
Maximum of 4 monitors can be connected to
a single A2200 in distributor mode (DIP
switch 1 OFF)
Maximum of 4 A2200 units can be connected
to single A2200 in raiser mode (DIP switch 1
ON)
Maximum of 32 monitors can be connected in
any given system.

3 | P a g e
Video camera module A3101
1. SET
DIP switches for system configuration.
2. JP-LK
Jumper for setting state of the NO contact
3. CN/KMB
Call button module A2400 connection port
4. CN/T-COIL
Not in use
5. BUS
L1, L2 bus line connecting to terminal
BUS(DS) on the power supply
6. CN-LK
+12V 12VDC power output.
LK- Power ground.
LK+ Common contact of the relay.
NO Normally open/closed contact (use
JP-LK jumper to set)
EB+ Exit button connection port.
EB- Exit button connection port.
7. CN/FUN
Not in use
8. CN/WGN
Not in use
DIP switch settings for A3101
The video module is configured by 6 DIP
switches.
The DIP switches can be modified either
before or after installation. Restarting the
camera module is necessary whenever the
DIP switches have been modified.
DIP switches 1 and 2 are for addressing door
station(s).
When multiple door stations are installed on
the system, these two DIP switches must be
set correctly.
Door station DIP switch settings:
No.1 = 00 (Default setting)
No.2 = 10
No.3 = 01
No.4 = 11
DIP switch 3 needs to be set to 0 for
mechanical call button operation.
DIP switch 4 is for call button automatic
allocation. Call buttons are automatically
assigned to the indoor unit. The default setting
for this DIP switch is 0.
DIP switch 5 is for setting door unlock time. 0
is the default setting for one second delay and
1 is the setting for five second delay.
DIP switch 6 is for activating keys A and B
which are used for programming camera
module functions.
The default setting for this DIP switch is 0.

4 | P a g e
Video module functions and
programming
Restore factory settings.
With Camera Module instandby, short out the
Exit Button Ports (EB+ and EB-) and toggle
DIP switch 6 four times.
A long Beep will sound, and all three indicators
will blink at the same time meaning the
Restore Factory Settings is in progress.
Once the three Indicators turn off with a
warning sound of a long Beep, it means the
Restore Factory Settings is complete.
Activate Programming mode and
touch keys, A and B
Key A and key B cannot be used on the
camera module until activated.
To activate the keys and set the unit to
programming mode, put DIP switch 6 to ON
position.
DIP switch 6 must be set to ON.
Other DIP switches must be set to OFF.
When programming is finished, put DIP switch
6 back to OFF position.
Sound theme settings.
When the Camera Module is in programming
mode:
1. Press and hold Key A for 3 seconds to
enter the Sound Theme Mode.
2. The Status indicator will turn on and
current theme sound, will play.
3. Press Key A again to play the next theme.
4. Press Key B to exit.
Sound volume settings.
When the Camera Module is in programming
mode:
1. Press Key B to enter Tune Volume
Setting, theTalkindicator will turn on and
play the sound at the current volume.
2. Press Key A to increase/decrease the
volume (loop setting)
3. Press Key B to exit.
Talk volume settings.
1. During the conversation, press and hold
Key B for 3 seconds to enter the Talk
Volume Setting.
The Talk indicator will turn on with a long
Beep followed by a short Beep.
2. Press Key A to increase/decrease the
volume (loop setting).
3. Press Key B to exit.

5 | P a g e
Electric lock mode settings
Set the Camera Module in to Programming
mode:
1. Press Key A, the Unlock Indicator will
turn on with the warning sound of a long
Beep followed by a short Beep!
2. Press Key A again to select lock mode:
a. Fail Locked Lock Mode = 0 (default)
Contact status: Normally Open
The Status indicator blinks once with the
warning sound of a single long Beep.
b. Fail Unlocked Lock Mode = 1
Contact status: Normally Closed
The Status indicator blinks twice with the
warning sound of a long Beep followed by
a short Beep.
Lock time delay setting
When the Camera Module is in programming
mode:
1. Press Key A. The Unlock indicator turns
on with the warning sound of a long Beep
followed by a short Beep.
2. Press Key B and hold for desired lock
opening time.
The Unlocking Time delay is indicated by the
number of times that the Status indicator
blinks (set in seconds). For example: The
Status indicator blinks four times, that means
the unlocking time is 4 seconds.
Electric lock with additional
power supply.
1. Contact rating is limited to 24V DC and
MAXIMUM CURRENT of 1000mA.
2. The jumper JP-LK must be taken off
before connecting.
3. Set electric lock mode using touch keys A
and B
Fail Locked Lock Mode = 0
(default)
Fail Unlocked Lock Mode = 1

6 | P a g e
Electric lock powered by internal
12V DC output.
Internal output is limited to 12V DC and
MAXIMUM CURRENT of 200 mA.
Jumper setting JP-LK:
1-2 Normally Closed (Fail Unlocked)
2-3 Normally Open (Fail Locked)
Normally Closed (Fail Unlocked)
12V DC 200mA MAX
Normally Open (Fail Locked)
12V DC 200mA MAX
Triggering a Gate automation:
When triggering a gate, must use A2601
auxiliary relay.
NOTE: Do not connect Gate contacts to
Video module as this will cause permanent
module damage.

7 | P a g e
Terminals
1. INPUT
Connect to CN/KMB port video module
2. OUTPUT
Connect to next call module.
3. J3
Call buttons 1, 3, 5, 7
4. J4
Call buttons 2, 4, 6, 8
Single module connections
Connecting multiple modules
(Max. 4)