1
Sound pressure level at (x) m from the appliance, 1.5 m from the ground,
free eld, directivity 2.
2 The acoustic power is a measurement made in the laboratory of the
power of the noise emitted but contrary to the noise level, it does not
correspond to the measurement of what is felt.
3 Refrigerating uid R410A in compliance with standard NF EN 378.1.
4 Factory charge of refrigerating uid R410A.
5 Taking into account the potential additional charge of refrigerating
uid R410A (see gure 25, page 22).
Denomination of model .........alféa hybrid duo ........10 ........ 13 ........16........11 tri ......14 tri........16 tri
Absorbed power
+7°C/+35°C - under-oor heating ........kW .......2,70 .......3,50 ......4,34 .......2,68 ...... 3,20 ........3,70
-7°C/+35°C - under-oor heating .........kW .......3,40 .......4,10 ......4,59 .......3,68 ......5,18 ........5,40
+7°C/+45°C - LT radiators ..............kW .......1,88 .......2,40 ......3,11 .......3,01 ...... 3,81 ........4,00
-7°C/+45°C - LT radiators ..............kW .......2,62 .......2,93 ......4,39 .......4,04 ...... 6,00 ........6,37
Coefcient of performance (COP) (+7°C/+ 35°C). . . . . . . . . . 3,67 .......3,80 ......3,42 .......4,95 ......4,14 ........4,02
Useful thermal power for boiler back up.........kW.............................25..................................
Electrical characteristics
Voltage (50 HZ) ..........................V.......230 .......230....... 230 .......400........400 .........400
Maximum current of the appliance ........... A........17 ........ 20 ........26........10.5 ......10.5 ........10.5
Nominal current .......................... A.......11.7 .......16.7 ......20.6 .......3.6 ........4.8 .........5.5
Actual power absorbed
- by the fan ...........................W.......103 ......2x103 ..... 2x103 .....2x104......2x104 ......2x104
- by the circulation pump ................W............................ 151.................................
Maximum power absorbed
- by the outdoor unit ....................W.......3910 ...... 4600 ......5980...... 7245 ......7245........7245
Burner (Stella 4000 unit), combustion chamber, chimney
Fuel ow rate .........................kg/h.............................2.3 .................................
Nominal caloric ow rate .................kW............................28.7.................................
Jet ...............................Delavan .........................0.6 gph 60° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Max. viscosity at 20°C.................... °E.............................1.5 .................................
Pump ..............................Suntec . . . . . . . . . . . . . . . . . . . . . . . . . . . .AL 35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Factory set pressure .....................bar.............................15..................................
Diameter (combustion chamber) ........... mm............................ 270.................................
Length (combustion chamber)............. mm............................ 400.................................
Volume (combustion chamber) ............ dm3............................22.9.................................
Volume on smoke side .................. dm3............................31.1.................................
Number of turbulators in the exchanger ........-............................. 7..................................
Temperature of the smoke.................°C............................ 190.................................
Mass ow rate of the smoke ..............kg/h............................44.4.................................
Boiler pressure .........................Pa .............................16..................................
Optimum low pressure in the chimney .......Pa .............................15..................................
Hydraulic circuit
Maximum operating pressure ..............bar............................. 3..................................
Flow rate of the hydraulic circuit at 4°C<Δt<8°C (nominal conditions)
- minimum ..............................l/h .......1000 ...... 1380 ......1670...... 1200 ......1500........1700
- maximum .............................l/h .......2100 ...... 2700 ......3300...... 2400 ......3000........3400
Domestic hot water tank
Capacity of domestic hot water tank .........litre............................ 125.................................
Maximum operating pressure ..............bar............................. 7..................................
Specic ow rate (in boiler mode only).........l/mn.............................19..................................
Miscellaneous
Weight of the outdoor unit .................kg ........64 ........ 98 ....... 105 ....... 99 ........99...........99
Weight of the hydraulic module (empty/with water) .kg . . . . . . . . . . . . . . . . . . . . . . . . . . .215/482 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Capacity of boiler........................litre............................ 142.................................
Expansion tank .........................litre.............................18..................................
Noise level at 1 m 1(hydr. mod. in thermodynamic mode) . dB............................35.5.................................
Acoustic power in compliance with
EN 12102 2(hydr. mod.) .......................dB............................43.3...................
Noise level at 5 m 1(outdoor unit) ............dB ........41 ........ 40 ........44........ 39 ........41...........42
Acoustic power in compliance with
EN 12102 2(outdoor unit)......................dB ........68 ........ 67 ........71........ 66 ........68...........69
Min./max. outdoor temp. (thermodynamic mode). . . °C ......-15/+24....-15/+24 ....-15/+24.... -25/+35 ....-25/+35 ....-25/+35
Max. water temperature for start of heating ...°C.............................80..................................
Max. water temperature thermodynamic mode.. °C ........52 ........ 52 ........52........ 60 ........60...........60
Refrigerating circuit
Diameters of the gas pipes .............inches.............................5/8 .................................
Diameters of the liquid pipes ............inches.............................3/8 .................................
Factory charge of refrigerating uid R410A 3.... g.......2100 ...... 3350 ......3400...... 2500 ......2500........2500
Max. operating pressure ..................bar............................41,5.................................
Min. length of pipes .................................0.........0......... 0.........5..........5............5
Max. length of pipes 4.....................m.............................15..................................
Max. length of pipes 5.....................m........25 ........ 25 ........25........ 20 ........20...........20
Max. difference in height 5..................m........25 ........ 25 ........25........ 20 ........20...........20
Installation and commissioning instructions “1440 - EN” - 5 -
Heat pump alfea hybrid duo