5
atlona.com Toll free: 1-877-536-3976
Local: 1-408-962-0515
HDMI IN
IR OUTIR IN
HDBaseT OUT
AUDIO OUT
123456 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12
17 18
19 20
13 14 15 16
OFF
ON
HDMI OUT
PWR: 100-240VAC 50/60Hz
1ED 2ED 3ED 4ED 5ED 6ED 7ED 8ED 910 11 12 13 14 15 16
1 2 345 6 78910 11 12 13 14 15 16
1
L R 2
LR3
L R 4
LR5
L R 6
L R 7
L R 8
L R 9
L R 10
L R 11
L R 12
L R
SSS S SSS S SSS S S S SSS S SSSSS S S S SSSSSS
IR INRS-232
MAIN
RX TX S
LAN FW
AT-UHD-PRO3-1616M
EDID
POWER ENTER
FNC CANCEL INFO
123 4
6 7 98
5
0
Back Panel
1. Long distance HDBaseT ports - Connect to long distance EX receivers for pass through
of PoE, control, and A/V signals. Ex. AT-UHD-EX-70C-RX
2. Extended distance HDBaseT ports - Connect to extended distance EX receivers for pass through
of PoE, control, and A/V signals. Ex. AT-UHD-EX-100CE-RX
3. HDMI Input - Connect HDMI sources to these ports
Ex. DVD players, Blu-ray players, computers, game consoles, etc
4. Audio out - Captive screw analog audio breakouts for use with a sound system or multi-channel
zone amplifier
5. IR IN - Use with a 3rd party IR control box to extend IR control commands to video displays over
category cable
6. IR OUT - Connect IR emitter here for controlling sources
7. LAN port - Connect to a network for TCP/IP, WebGUI, and firmware updates
8. FW port - USB not enabled at this time for future functionality
9. Main system control - Connect IR or RS-232 control system to the matrix
10. Internal power supply - Connect included IEC C13 power cable from here to a power outlet.
11. HDMI outputs - Mirror to provide a local output for HD audio routing to an AVR, or matrix the
ports to provide a local video output for in room displays or an HDBaseT extender set
Ex. AT-UHD-EX-100CE-KIT or AT-UHD-EX-70C-KIT
To rack mount the UHD-PRO3-1616M
unit: use the rack mount ears, the 6
screws from the sides of the UHD-
PRO3-1616M, and 4 rack screws.
To affix the rack mount ears, remove
the three screws on each side of the
UHD-PRO3-1616M and affix the rack
ears to the UHD-PRO3-1616M (as
shown in the picture to the left).
Place the UHD-PRO3-1616M in the
rack, lining the holes in the rack ears
with the holes in the rack. Once
placed, use the rack screws to keep
the unit in place. (as shown in the picture
to the left)
Note: Increase the air flow as needed to
maintain the recommended
temperature inside the rack.
Note: Do not exceed maximum weight loads
for the rack. Install heavier equipment
in the lower part of the rack for
stability.
3
2
11
1
5 6
4
9
810
POWER ENTER
CANCEL INFO
EDID
FNC
678
12 3
9
4
0
5
POWER ENTER
CANCEL
INFO
EDID
FNC
678
12 3
9
4
0
5
Rack Mounting
7