ATM Lighting TNL320LED Manual

ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk POLAND, tel: +48 58 347 51 07, fax: +48 58 347 51 08
Read this manual carefully before installation.
INSTALATION AND MAINTENANCE MANUAL
FOR THE LIGHTING LUMINAIRE SYSTEM
TNL320LED

2 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
1. GENERAL INFORMATION ............................................................................................................. 3
2. TECHNICAL DATA .......................................................................................................................... 3
3. PHOTOMETRICAL DATA ............................................................................................................... 4
4. CONSTRUCTION ........................................................................................................................... 4
5. PRELIMINARIES ............................................................................................................................ 5
6. INSTALLATION ............................................................................................................................... 5
7. ELECTRICAL CONNECTION ......................................................................................................... 6
8. CONDITIONS OF SAFETY USE .................................................................................................... 7
9. LIGHT FITTING MAINTENANCE AND SERVICING ...................................................................... 7
10. SPARE PARTS .......................................................................................................................... 8
11. REPAIRING ............................................................................................................................... 8
12. LIGHT SOURCE EXCHANGE ................................................................................................... 8
13. TRANSPORT AND STORAGE CONDITIONS .......................................................................... 8
14. DOSPOSAL OF WASTE EQUIPMENT ..................................................................................... 8
15. WARRANTY .............................................................................................................................. 8
TABLE OF CONTENTS

3 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
1. GENERAL INFORMATION
TNL320LED lighting system is designed to mark evacuation doors. Suitable for use in tunnels. The
luminaire is equipped with a power supply with DALI protocol.
Risk group of the LED modules RG = 1.
2. TECHNICAL DATA
Luminaire type
Source
power
Power
supply
IP
Protection
class
Power factor
TNL320LED
68,2 W
230V
0,50,60Hz
65
I
0,97

4 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
1. Dimensions of individual elements:
o Power box:
o Luminaire:
3. PHOTOMETRICAL DATA
Luminaire type
Luminous flux
of the system
Lifetime of
modules
TNL320LED
>200 lm
>70000 h
Lifetime of LED modules: L70B10
4. CONSTRUCTION
The luminaire has been built in accordance with the principles of good engineering practice. The product
meets the essential requirements of the directives and harmonized standards listed in the provided EU
declaration of conformity.
The housing is made of 316 Ti stainless steel. The diffuser is made tempered glass.
The set consists of 6 luminaires shining on both sides, 2 luminaires shining on one side and a power
supply box.

5 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
5. PRELIMINARIES
SAFETY RULES
• Before starting the installation, carefully read all the information contained in this manual,
• General safety rules should be followed,
• Failure to comply with the installation and use rules may result in personal injury or material
loss. ATM Lighting sp. z o.o. is not responsible in such cases,
Failure to follow the recommendations in this manual will void the manufacturer's warranty.
NECESSARY TOOLS
6. INSTALLATION
The TNL320LED luminaire should be mounted directly on the wall with dowels. Installation dimensions
are given in point 2 of this manual (page 4)
TNL320LED system consists of 6 luminaires on both sides, 2 luminaires shining on one side
(downwards) and a power box. Housings should be mounted as follows:

6 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
Luminaires are marked with the following symbols:
A1, B1
Luminaires mounted horizontally above the door (A1 on the left, B1 on the right).
A2, A3, A4
Luminaires mounted vertically, on the left side of the door (from top A2, A3, A4).
B2, B3, B4
Luminaires mounted vertically, on the right side of the door (from the top B2, B3, B4).
Power Supply A i B
Marking of connections of luminaires mounted horizontally (A1 and A2) to the power box.
For example, the socket marked "Power Supply A (" should be connected to the socket in
the power box marked "Power Supply A".
A1-A2, A2-A3, A3-A4,
B1-B2, B2-B3, B3-B4
Designations of connections of individual luminaires. For example, socket marked A1-A2 in
A1 socket should be connected to socket A1-A2 in A2 luminaire.
Direction of installation of luminaires arranged vertically. Housings should be mounted so
that the arrow is pointing upwards.
Installation of luminaires marked with the above symbols does not require opening them.
7. ELECTRICAL CONNECTION
To co n n e c t t h e po we r s u p p l y:
• insert the power cord into the power box, through the cable entry (gland),
• carefully remove insulation the cable conductors (8-10mm) and then insert them into connector
according to the marking inside the housing,
• tighten the power cord in the gland with 2 keys,
• connect the grounding of the lid and check the effectiveness of the grounding.
Attention:
• Use one key to tighten the gland sealing nut while securing the gland body with the other key
against rotation.
• Failure to comply with the above remark may damage the sealants, thus reducing the degree
of tightness.
Power connection diagram:

7 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
8. CONDITIONS OF SAFETY USE
•
Each luminaire has a nameplate with technical data. Each luminaire has an instruction and
operating manual, which should be kept until the end of the luminaire's useful life.
•
The luminaires are suitable for fixed installations only.
•
Operation of the luminaire outside the designated operating temperature range will lead to faster
wear and/or damage. At the same time, it I cause the loss of the manufacturer's warranty.
•
Each luminaire must have a warning plate saying: "DO NOT OPEN UNDER VOLTAGE".
•
7-conductor cables (with PE conductor) with a maximum external diameter of 1.3-21 mm
should be used as power cables.
•
Unused glands should be properly plugged with special plugs,
•
Power wires with a cross section of 0.5-10 mm2 should be used.
•
Maximum load on through-line cables I=32A
• Do not stare at a working light source
• Risk of electric shock
9. LIGHT FITTING MAINTENANCE AND SERVICING
REMARK:
during service and conformation works, it is forbidden to touch LED points, as this will reduce
the life of the luminaire and lose the manufacturer's warranty.
INSPECTION:
at least once a month, the luminaire should be inspected without opening it. Check the
condition of the power cords (insulation damage, cracks, burns, etc.). Cables must not be refracted at
sharp angles. Visual inspection of the exterior parts. There must be no cracks or signs of corrosion. The
mounting screws must be tensioned. Check the cleanliness of the outer surfaces of the housing. The
luminaire must not be contaminated with paint or greasy. Do not allow dust and dust to accumulate on
the luminaire. Check the legibility of the statutory plates. Any irregularities encountered must be rectified
immediately.
SERVICE AND MAINTENANCE:
should be performed at least once a year. Service and maintenance
should be carried out with the power disconnected. First you need to make a visual inspection. After
opening the luminaire, check the condition of the protective coating of metal parts, the condition of
internal connection cables and their fixing, the condition of insulation elements, fittings, glands and
gaskets. Markings and statutory plates must be cleaned. Any irregularities encountered must be rectified
immediately.
VERIFICATION OF TECHNICAL CONDITIONS
: at least once every two years. Disconnect the power
supply from the luminaire. In addition to the tests carried out during inspections and maintenance,
electrical tests should also be carried out: measurement of the current consumed by the luminaire,
measurement of the insulation condition, measurement of the effectiveness of the protective connection.
Particular attention should be paid to the condition of the insulating parts. There should be no traces of
cracks and burns on them.
CLEANING:
Do not allow dust and dust to accumulate on the luminaire. Cleaning of luminaires should
be carried out using compressed air and a soft cloth or soft brush. If necessary, use water and/or neutral
detergent, but do not use chemicals that may damage any part of the housing.

8 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
10. SPARE PARTS
All spare parts must be ordered from the luminaire manufacturer.
11. REPAIRING
Any repairs can only be made by the manufacturer or an authorized service workshop.
12. LIGHT SOURCE EXCHANGE
The light source used in this luminaire should only be replaced by the manufacturer or his
service representative or a similarly qualified person.
13. TRANSPORT AND STORAGE CONDITIONS
Luminaires should be transported by covered means of transport, protected against strong shocks.
Luminaires may only be stored in covered rooms at a temperature of +5ºC to +35ºC and humidity of
less than 75%. The premises should be free of corrosive vapors and gases.
14. DOSPOSAL OF WASTE EQUIPMENT
User must obey relevant rules and regulations about disposal of wasted equipment valid in
their country.
15. WARRANTY
• It is forbidden to use a damaged or defective luminaire. In order to detect any irregularities,
checks must be carried out on the installation.
• It is required to disconnect power supply from the light fitting before any maintenance work.
• It is forbidden to make any changes to the light fitting construction. Any unauthorized
interference may result in reduced functionality or damage to the device and may in some
cases endanger life or health. At the same time it relives the manufacturer of all warranty
liability.
• All specific information can be found in document „General terms and conditions warranty
ATM Lighting sp. z o.o.” available at the website www.atmlighting.pl/en/

9 ATM Lighting sp. z o.o., ul. Maszynowa 30A, 80-298 Gdańsk, POLAND, tel: +48 58 347 51 07, fax: +48 58
347 51 08
ADDRESS:
ATM Lighting sp. z o.o. !
ul. Maszynowa 30A !80-298 Gdańsk, POLAND
tel: +48 58 347 51 07!fax: +48 58 347 51 08
Table of contents
Other ATM Lighting Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Lightolier
Lightolier LSB-15 Specification sheet

Equinox Systems
Equinox Systems FUSION SPOT MAX MKII user manual

V-TAC
V-TAC VT-1143 Installation instruction

Image Projection
Image Projection iPro 150E Instruction and user's manual

Lumotech
Lumotech ECOline L05044 manual

olympia electronics
olympia electronics GR-939/15L/MAR manual