Submenu CH settings heat pump
To access to the submenu CH settings heat pump go to setting d in the service settings menu (installer
program) and press the hot water button. On the status display the first setting d / h is alternately displayed.
By pressing the set button the next setting is displayed. Change the setting by pressing the hot water button.
Pressing the reset button twice will exit the menu and save the settings.
Status
display
CV water
display
Description Remarks
d / h 01
03
05
Overrun time CH pump heat pump 1 minute
Overrun time CH pump heat pump 3 minutes
Overrun time CH pump heat pump 5 minutes
d / H 10
20
30
40
50
60
WDC pump switching interval period 10 minutes
WDC pump switching interval period 20 minutes
WDC pump switching interval period 30 minutes
WDC pump switching interval period 40 minutes
WDC pump switching interval period 50 minutes
WDC pump switching interval period 60 minutes
d / o 12
…
20
…
24
WDC base point at outside temperature 12 ºC
WDC base point at outside temperature …. ºC
WDC base point at outside temperature 20 ºC WDC base
point at outside temperature …. ºC
WDC base point at outside temperature 24 ºC
Adjustable in
increments
of 1 ºC
d / O 15
…
30
…
25
…
50
WDC flow temperature 15 ºC at base point d / o
WDC flow temperature .... ºC at base point d / o
WDC low temperature 30 ºC at base point d / o
WDC flow temperature .... ºC at base point d / o
WDC flow temperature 25 ºC at base point d / o
WDC flow temperature .... ºC at base point d / o
WDC flow temperature 50 ºC at base point d / o
Adjustable in
increments
of 1 ºC
d / P -5
…
2
…
10
WDC base point night reduction at base point - 5 ºC
WDC base point night reduction at base point - … ºC
WDC base point night reduction at base point 2 ºC
WDC base point night reduction at base point - … ºC
WDC base point night reduction at base point 10 ºC
Adjustable in
increments
of 1 ºC
d / q 12
15
18
21
24
WDC recalculation time RT 12 minutes
WDC recalculation time RT 15 minutes
WDC recalculation time RT 18 minutes
WDC recalculation time RT 21 minutes
WDC recalculation time RT 14 minutes
d / S 4
6
8
10
WDC switching difference 4 ºC
WDC switching difference 6 ºC
WDC switching di erence 8 ºC
WDC switching difference 10 ºC
d / t 1
2
4
6
Waiting time for switching on the gas boiler 30 minutes
Waiting time for switching on the gas boiler 60 minutes
Waiting time or switching on the gas boiler 120 minutes
Waiting time for switching on the gas boiler 180 minutes
d / u -15
…
-10
…
0
WDC climate point at outside temperature – 15 ºC
WDC climate point at outside temperature – … ºC
WDC climate point at outside temperature – 10 ºC
WDC climate point at outside temperature – … ºC
WDC climate point at outside temperature 0 ºC
Adjustable in
increments
of 1 ºC
d / U 25
…
40
…
80
WDC flow temperature 25 ºC at climate point d / u
WDC flow temperature … ºC at climate point d / u
WDC low temperature 40 ºC at climate point d / u
WDC flow temperature … ºC at climate point d / u
WDC flow temperature 80 ºC at climate point d / u
Adjustable in
increments
of 1 ºC
Adjustable in
increments
of 5 ºC