Auerswald TFS-Dialog 200 User manual

Page 1 of 16
Door intercom system TFS-Dialog 200
A short manual for
operation, installation, mounting and programming
Contents
Security Advice ..................................................................................................................................... 2
Scope of Supply.................................................................................................................................... 2
Overview ............................................................................................................................................... 3
Open the housing.................................................................................................................................. 3
Closing the housing............................................................................................................................... 6
Labelling the name plates..................................................................................................................... 8
Programming......................................................................................................................................... 9
Analog switch modules ....................................................................................................................... 12
Connection diagrams.......................................................................................................................... 14

Page 2 of 16
device itself may also be dangerous to life.
device.
Care instructions
ATTENTION
The surface can be damaged by detergents.
Please do not use aggressive or solvent
based detergents.
NOTE
The device is weatherproof and does not
need additional care. When dirty please
clean the device using a damp cloth.
Scope of supply
Base unit TFS-Dialog 200 (201 – 204
depending on model)
Complete manual (German)
This short manual (English)
Labelling stripes
Mounting material for wall mounting
Special key for opening the housing

Page 3 of 16
Housing
Bell buttons
Name plate glass
Special key
Illumination plate (for the background
illumination)
Lock spring
Loudspeaker aperture
Installation and mounting
TFS-Dialog 200 overview
1 Push the special key (4) into the small opening
in the loudspeaker aperture.
2 Press the key in the direction (A) against the
force of the spring to the stop and hold it.
3 Push the name plate (3) with slight force into
direction (B) until it comes out of the profile
4 Pull the key out of the hole.
Open the housing
WARNING!
Danger of electric shock.
- Please disconnect the connection to the
analog port of the PBX and to the ringing
transformer BEFORE opening the housing.
CAUTION!
Possible damage due to wrong handling.
- Please follow the steps mentioned below.

Page 4 of 16
5 Take out the name plate in direction (D).
6 Pull out the name plate to the bottom in
direction (E).
For the next mounting and installation steps the
illumination plate for the background
illumination has to be taken out.
Now the glass of the name plate is removed
and can be labelled as described later.
7 Release the illumination plate with the
special key by pressing on the spring in
direction (F).
Please observe: it is connected with a
cable!
8 Take out the illumination plate
9 Pull out the connector in direction (G).
CAUTION!
Possible damage of the illumination
panel with the loudspeaker blind.
- It is mandatory to remove the
illumination plate out of the housing.
Installation and mounting

Page 5 of 16
The housing (11) can be fixed to the
wall with two screws using the holes
(9).
For the storage of reserve cabling a
flush mount socket can be used
optionally (like indicated in the
drawing above).
WARNING!
Fluids intruding into the housing may lead to
a perilous electric shock or to the damage or
destruction of this device.
- Please observe when choosing the
mounting location that this device is not
exposed to direct rainfall.
- Do not mount this unit on free-standing
objects which are not protected against
rainfall.
Before mounting the housing of TFS-Dialog 200
is to be opened (see also “Open the housing”).
Mounting on the wall
10 Pull the loudspeaker blind
in direction (H).
Cable connectors: 8
Holes for mounting: 9
Hole for cabling: 10
Installation and mounting
A decription of the cable connectors you can find at the end of the manual.

Page 6 of 16
The optional weather protection (13)
can be fixed on the wall with two
screws (14). The TFS-Dialog 200 can
be fixed to the weather protection with
two screws.
If a module frame for older Auerswald
door phones is present it can be
covered with the weather protection. It
can be fixed directly onto the frame.
1 Press down the loudspeaker gently a little bit in
direction (L) and hold it.
2 Push the loudspeaker aperture up to the upper end
in direction (M).
3 Connect the plug of the lighting plate with the base
board in direction (N).
By choosing the according connector the operation
mode of the power supply matching the implemented
connection will be set.
For power supply using the analog port please
use the right connector (marked with a/b)
For power supply using a ringing transformer
please use the left connector (marked ~).
CAUTION!
Possible damage of the loudspeaker when
moving up the loudspeaker blind incorrect
-
Please
act as mentioned below
.
Closing the housing
Installation and mounting
For the storage of reserve cabling a flush
mount socket can be used optionally (like
indicated in the drawing above).
WARNING!
Fluids intruding into the housing may lead to
a perilous electric shock or to the damage or
destruction of this device.
- Please observe when choosing the
mounting location that this device is not
exposed to direct rainfall.
- Do not mount this unit on free-standing
objects which are not protected against
rainfall.
Before mounting the housing of TFS-Dialog 200
is to be opened (see also “Open the housing”).
Mounting with a weather protection
The weather protection (13) available as
an accessory will be fixed to the wall with
two screws using the screw holes (14). For
the marking of the drilling holes you can
use the weather protection. The mounting
material is included.
The mounting of the TFS-Dialog 200 will
be made using the fixation holes (9) of the
weather protection and screws.
NOTE
With a connected lighting plate the TFS-
Dialog is permanently occupying the analog
port to get the necessary power. In that case
it is not possible to call the door phone.

Page 7 of 16
4 Press down the lighting plate with slight
pressure in direction (O) and hold it.
5 Place the name plate in the slide rail on
the two sides while holding the lighting
plate.
6 Slide the name plate in direction (P)
under the loudspeaker aperture until it
stops and hold it in direction (R).
Please observe: do not push the lighting
plate out of its hold when pushing up the
name plate!
7 Release the lighting plate – it is fixed
now.
8 Push the special key into its hole and
press down the spring in direction (Q).
9 Put the lighting plate with its upper end
first into the housing.
10 Press down the lower end in a way that
it is safely fixed between the two ends of
the spring.
Please observe the correct position of the
cut-outs at the low end of the plate!
Installation and mounting
Important
Please observe that all cables are
stored below the illumination plate.
Hint
Should the illumination plate slide out of
the holding springs during further
mounting please fix it again in a correct
way because otherwise an optimal
illumination cannot be guaranteed..
Wrong!
Correct!

Page 8 of 16
11 Now you can push the name
plate further up in direction (R).
12 Pull out the special key in
direction (S).
13 Press the name plate down in
direction (T) against the springs
until it stops.
14 Slide the name in direction (U)
into the profile until it locks in
place audible.
Now the door phone is usable.
Installation and mounting
Labelling and inserting of the name plates
1 Open the housing using the spezial key and
take out the name plate glass (3).
2 Label the name plates (17) directly with a pen
or use the print templates you can find on
www.auerswald.de under „Service ... Download
... Handbücher ... Zubehör“
3 Insert the finished plates into the slots (16) at
the back of the name plate glass in the
direction (K).
4 Insert the name plate glass
(3)
as described
above.
HINT
If the edges of the slots are too tight to the
glass you can open the slots by pressing
slightly towards the middle with both thumbs.
To take out the labels you could use tweezers.

Page 9 of 16
Start the programming
Press any bell button (you will
hear a tone) and hold it for
approx. 5 seconds until a
second signal tone can be
heard.
Within 3 minutes:
Pick up the handset of
one of the internal
telephones
Dial the internal number
of the TFS-Dialog 200 –
the connection is
established.
Execute the programming
First programming or after a programming break of more than 3 minutes
Dial
star. Short
tone.
Input PIN
and close
with star
Wait for the end of the
tones (five short
tones)
Dial the
programming
code of the
desired function.
Wait for the end
of the
acknowledgement
tone
Programming
Wait for the end of the
acknowledgement tone Dial the programming code of
the desired function. Wait for the end of the
acknowledgement tone
Hint
You can make more than one
programming one after the other
without putting the handset
back. Exceptions are described.
Correct input will lead the
acknowledgement tone (six
tones). Wrong input will give an
occupied signal for 1-2 seconds.
Start again with star (*).
For protection please set a PIN.
At subsequent programming the PIN
must not be entered again.
The programming mode ends 3
minutes after the last programming or
when a bell button is pressed.
Dial
star.
Additional programming

Page 10 of 16
Allocation of numbers to the bell buttons 1 -4 (default: 31 – 34)
Dial number 1 -4
of the bell button Set the target
number
Hang up – for more
programming take off
the handset and dial
the internal number of
the TFS-Dialog 200
Only necessary once –
see above on the first
page
Allocation of switching frequencies to the bell buttons 1 -4 (default: 1 – 4)
Dial number 1 -4
of the bell button Dial number 1 -4
for the switching
frequency
Only necessary once – see above on the
first page
Allocation of additional door bells to the bell buttons 1 -4 (default: 1, 2, 0, 0)
Setting of the switching time for lighting (default: 0,5 sec.)
Only necessary once – see above on the
first page
Dial number 1 -4
of the bell button Dial number 1 or 2 of
the additional bell
(0 = none)
Only necessary once – see above on the
first page
Set time between (1 x 0,5 =) 0,5 sec. and
(9 x 0,5=) 4,5 sec.
Switching on the light during a door call (default number: 8)
Only necessary once – see above on the
fi
rst page
Any series of digits possible (1-6 digits)
Will be activated from the phone by dialling # + above set digits

Page 11 of 16
Setting the time for the door opener (default: 2 sec.)
Opening the door during the call (default number: 9)
Only necessary once – see above on the
first page
Set time between (1 x 0,5 =) 0,5 sec. and
(9 x 0,5=) 4,5 sec.
Only necessary once – see above on the
first page Any series of digits possible (1-6 digits)
Will be activated from the phone by dialling # + digits
Setting of the input sensitivity (default:1)
Setting the volume of the loudspeaker (default: 6)
Seeting the environment sound level (default number: silent)
Only necessary once – see above on the
first page Set the input sensitivity between low (1)
and high (9)
Only necessary once – see above on the
first page Set silent (0) or loud (1)
Only necessary once – see above on the first
page Set the volume between low (0) and high (9).

Page 12 of 16
Reset to factory settings
Change of the PIN (default: 0000)
Only necessary once – see
above on the first page Hang up – before new configuration the
programming has to be started new.
Only necessary once – see
above on the first page Type in new PIN (1-6 digits) two times and end it with
# each time
A short intro to:
a/b Switching Modules
It has six switching frequencies: No. 1 - 4 are related to bell buttons on the TFS-Dialog 200 with free
allocation. The other two can be used for door opening (No. 6) and light (No. 5) controlled by the
telephone which is doing the door call by dialling of certain numbers.
Please observe: the a/b switching modules are not made for 230 V!! For this you would have to use a
matching relay in between. The switching lasts for 1 to 4,5 seconds - if you need a longer time (e.g.
stairscase lighting) you will need a time relay. For some installations with high internal resistance (e.g.
staircase lighting) the included resistor has to connected parallel (see picture page 24 - top right
corner).
You can set the switching frequencies like this:
* PIN * 3 (number of button 1 - 4) (number of frequency 1 - 4)
Example: *0000*312 (button 1 (the top button) activates switching frequency 2)
How to start the programming see above.
Door opening is: * PIN * 56 (time 1 = 0,5 sec. - 9 = 4,5 sec.)
example: *0000*564 (for 2 sec. of door opener)
... and you will have to switch the module itself to "5" with the DIP switch.

Page 13 of 16
Expansion of the installation with a/b switching modules
Basic parts a/b switching module
1 Connection for the device that
should be switched
2 Connection to the two-wire line
parallel to the TFS-Dialog 200 and
the internal analog port.
3 DIL switch
The TFS-Dialog 200 can be expanded with
the optional a/b switching modules to get
more switching functions (e.g. switching of
additional door bells, a second door
opener or a stairway lighting) not having to
install additional lines to the TFS-Dialog
200.
An a/b switching module switches on the
connected device only when a signal in a
certain frequency has been sent via the
line. In total up to six different switching
frequencies are available which can be
controlled by using the integrated DIL
switch.
Switching frequency 1
Switching frequency 2
Switching frequency 3
Switching frequency 4
Switching frequency 5
Switching frequency 6
Four
switching frequencies (frequency 1 to
4) are meant for the door bells 1 to 4 and
can be allocated to these buttons freely.
Two additional switching frequencies can
be used for door opening (frequency 6) or
for lighting control (frequency 5).
The control of both functions (door opener
and light) is done with the telephone which
has the door call at that time and is
executed by dialling a certain sequence of
digits.
Only the lighting control can be executed
additionally by one or all bell buttons.
NOTE!
The a/b switching modules are
not made for the direct
connection of 230 V mains!
- For the switching of 230 V devices an
additional relay circuit has to be used.
IMPORTANT!
The a/b switching can hold the
switching mode only for 1 to 4,5
seconds!

Page 14 of 16
IMPORTANT!
The a/b switching modules need
for a smooth operation a very
low standby current. When
connecting an electronic door
bell or a staircase light controller
with a high internal resistance
that modules may not work
correctly.
Alternatively to the door bell buttons you
can use the switching frequencies 1 to 4
during a door call (e.g. for the switching of
a second staircase light controller).The
control is done with the telephone which
has the door call at that time and is
executed by dialling a certain sequence of
digits.
- If longer times are necessary please
use a time relay like a staircase light
controller.
- For this case every a/b switching
module comes with an additional
resistor which can be connected to the
electronic door bell or a staircase light
controller to guarantee a minimal
standby current for the feeding of the
module..
HINT!
How to connect this:
1. Connect the a/b switching modules with
the clamps named aand bto the line
between the TFS-Dialog 200 and the
internal analog port.
2. Connect the device which should be
switched and the power supply to the
other two clamps.
Switching
frequency
1
Switching
frequency
2
a/b switching module
a/b switching module
PBX e.g. Auerswald
Power supply
Additional resistor (330 Ω,
capacity min. 1 W)
Electronic
door bellDoor bell 1
Control of additional door bells with a/b switching modules

Page 15 of 16
PBX e.g. Auerswald
Power supply
Switching
frequency
5
Switching
frequency
6
a/b switching module
a/b switching module
Additional resistor (330 Ω,
capacity min. 1 W)
Door opener Staircase light
controller
Control of door openers and staircase lighting with a/b switching modules
Control of additional bells, door opener and staircase lighting
Staircase light
controller Door opener Bell 1
Bell 2
PBX e.g. Auerswald
Power supply

Page 16 of 16
NOTES
1 To the analog port of the PBX
2 Supply voltage out of the ringing
transformer
3 Bell output 1
4 Bell output 2
5 Connection for the door opener
6 Connection for stairway lighting
7 Common connection for the Supply
voltage out of the ringing transformer
1
7
2
Example: basic connection
Connection to analog PBX port: 1a and 1b
Connection of the ringing transformer: 7 and 2
1a 1b
2 7
This manual suits for next models
5
Table of contents
Other Auerswald Intercom System manuals
Popular Intercom System manuals by other brands

Panasonic
Panasonic VL-VM701 Installation and operating instructions

Robin
Robin SIP Technical instruction, Replacement SD-card

Spacetronik
Spacetronik DIO SPD-DS81 Series user manual

Channel Safety Systems
Channel Safety Systems ENTRitech user manual

Bpt
Bpt LINEAKIT Instructions for use and installation

Videx
Videx Smart Series manual