
4.3. Type of Cable
The types of cables are to be determined according to the
following conditions.
Twis ted p air wires ( suc h as th ose us ed fo r elec tro nic
push-button telephone) are to be used for wiring between
the Exchange and the stations in principle.
The numb er of cab les pair s laid should be de termin ed
con sid eri ng t he po ssi bil it y of fu tur e ex pan sio n of th e
system.
Out do or w ir es s ho ul d be u se d wh er e wi ri ng p as se s
through inaccessible areas such as ceilings or under floors
where t he main tenan ce is not p erfo rmed. I ndoor w ires
may also be used, however, in case where there is no risk
of deterioration due to exposure to heat, etc.
Note
Specifications related to each junction are as follows.
Mini-clamp connector (N-8000EX/8010EX line terminal)
Conductor diameter: ø0.4 – 0.65 mm (AWG22 – 26),
solid wire
Outside diameter: ø1.05 mm or below
Clip terminal (E-7000TB)
Conductor diameter: ø0.4 – 0.8 mm (AWG20 – 26),
solid wire
Outside diameter: ø1.5 mm or below
Terminal station (LINE, H, C terminals)
Conductor diameter: ø0.4 – 1.3 mm (AWG16 – 26),
solid wire, stranded wire
4.5. Terminal Station Connection
Step 1. Stri p a cabl e jack et of ap prox 7 m m to exp ose
inner cable.
For cables, refer to Type of Cable.
Note
Do not solder plate on exposed inner cables when
using a stranded wire.
Step 2. Loosen the terminal screws and insert the cables.
Step 3. Tighten the terminal screws securely.
Notes
Tug lightly on the cable to be sure that it does not
pu ll f re e. I f th e ca bl e p ul ls f re e, l oo s en t he
terminal screw again and reconnect from Step 2.
To a v oi d s tr i pp i n g th e s cr e ws , u se t h e
screwdriver appropri ate to the screws tighten ed
into the terminal plug.
4.4. Relations Between Core Diameter of Cable
and Maximum Cable Length
Referrin g to the foll owing char t as guideli nes, desi gn the
distance between the Exchange and stations so that l oop
resistance becomes 170 or less.
4.6. Mini-clamp Connector Connection
Conn ect the min i-cl amp c onn ecto r sup plie d wit h the N-
8000EX/8010EX to a cable using a commercially available
tool (pliers).
Step 1. Cut off two-cable ends in equal length, and insert
them securely to a cover section (transparent side)
of the mini-clamp connector.
Note
Inse rt the c able w itho ut
stripping the cable jacket.
Step 2. With a pair of pliers , lightly
pinch the mini- clamp cover
and, after ensuring that the
cable i s secu rely i nsert ed,
firmly squeeze on the cover.
Note
Sq u ee z e on t h e mi n i- c l am p c ov e r un t il i t i s
correctly locked.
Step 3. In s er t t he w i re d c on n ec t or ( p lu g ) i nt o t he
exchan ge's co nnect or (soc ket) un til it loc ks into
place.
Cover
(transparent side)
Cable
N-8000EX/8010EX Rear panel
Conductor Loop Maximum cable length
diameter resistance between the Exchange and station.
(mm) ( / km)
(Assuming that the loop resistance is 170 .)
ø0.4 295 570 m
ø0.5 187 900 m
ø0.65 113 1.5 km
ø0.9 58 2.9 km
7 mm
Tighten
Terminal screw
Cable
133-02-002-9700