Power Output 60 Watts RMS
Maximum Load 80 Ohms @ 70 Volts
Power Bandwidth 60Hz - 17kHz (- 3dB)
Frequency Response 60Hz - 23kHz (- 3dB)
Total Harmonic Distortion 0.5% @ 1 KHz rated power
Signal To Noise Ratio -74dB with all controls at their centre position
Tone Controls Bass @ 100Hz: Boost +12dB Cut -12dB; Treble @ 10kHz: Boost +9dB Cut -9dB
Inputs Four mic/aux universal inputs with XLR female mic sockets and dual RCA aux sockets;
600 ohm transformer balanced telephone paging input
Input Sensitivity Mic: 1mV @ 200 Ohms; Aux: 150mV @ 47K Ohms
Outputs Speaker: 70 Volts, 8 Ohms; Tape: 350mV @ 10K Ohms; Line: Balanced 700mV
Phantom Power 18 Volts DC on all Mic inputs (rear panel on/off switch)
Speaker Zone Selection Speaker zone selector, switches line output to 6 separate zones.
An ”all call“ switch overrides alI zones.
Controls 4 Input channel gain controls, 1 Bass control, 1 Treble control,
1 Master gain control, 6 Speaker zone selector, 1 Speaker ”all call“ selector,
Pre-announce defeat switch, Phantom Power on/off switch (on rear panel)
Indicators Power ”on“ LED
Power Source 120VAC 60Hz 3 pin IEC connector; 24VDC
Power Consumption 125 Watts
Protection Soft limiter for overload and overdrive protection, plus AC and DC fuses
Dimensions/Weight 3.5" H x 19" W x 13" D (Chassis Dimensions only). 22lb
Rack Mounting Standard
Tone Generators Built-in four tone generator module.
Includes Bell, Pre-Announce, Alert and Evac tones
Muting Built-in VOX muting. Channels 1 and 2 will mute channels 3 and 4.
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The mixer amplifier shall have four universal input channels, each comprising of a balanced microphone input
with XLR female sockets and an auxiliary input using dual RCA sockets. The 70 volt line speaker outputs
should be able to be switched via a six position selector with ”all call.” A balanced XLR output to drive addi-
tional power amplifiers shall also be provided.
The amplifier master section shall include one master gain control, two EQ controls, one with 12dB of cut and
boost at 100Hz and the other with 9dB of cut and boost at 10kHz. Speaker outputs shall be transformer iso-
lated at 70 volt and 8 ohms. The amplifier must be capable of delivering 60 watts RMS into an 80 ohm induc-
tive load, with less than 0.5% distortion measured at 1kHz and with system hum and noise less than -74dB.
The amplifier shall be an Australian Monitor Installation Series model AMIS60.
UL APPROVED
PO Box 3126, Lynnwood, WA 98046 • Voice: 425-673-5175 • Fax: 425-673-7825
• Website: www.australianmonitor.com • Email: sales@australianmonitor.com
AUSTRALIAN MONITOR AUDIO INC.