Autarco S2.1P User manual

Installation and Operation Manual
Consumption meter
IM-S2.1P-SMARTMETERI-EN-V1.0 Manual

Contact Information
Autarco Group B.V.
Schansoord 60
5469 DT Erp
The Netherlands
www.autarco.com
info@autarco.com
Other Information
This manual is an integral part of the unit. Please read the manual carefully before installation, operation or
maintenance. Keep this manual for future reference.
Product information is subject to change without notice. All trademarks are recognized as the property of
their respective owners.
© Autarco Group B.V.
All rights reserved.
2

Table of Contents
1. Introduction 4
1.1 Read this first 4
1.2 Target Audience 4
1.3 Intended Application 5
2. Preparation 5
2.1 Safety instructions 5
3. Overview 5
3.1 Front Panel Display 6
3.2 LED Status Indicator Lights 6
4. Installation 7
4.1 Mounting the Consumption meter 7
4.2 Electrical Connections 7
4.3 Wiring 8
4.4 Monitoring 9
5. Specifications 10
3

1. Introduction
1.1 Read this first
This manual contains important information for use during installation and maintenance of the
Consumption meter with Autarco’s inverters.
To reduce the risk of electrical shock, and to ensure the safe installation and operation, the following safety
symbols appear throughout this document to indicate dangerous conditions and important safety
instructions.
WARNING! Indicates safety instruction, which if not correctly followed, can result in injury
or property damages.
RISK OF ELECTRIC SHOCK! Indicates safety instructions, which if not correctly followed,
could result in electric shock.
HOT SURFACE! Indicates safety instructions, which if not correctly followed, could result
in burns.
1.2 Target Audience
This manual is intended for anyone who installs or maintains Autarco inverters in conjunction with a
Consumption meter. Before any further action, the operators must first read all safety regulations and be
aware of the potential danger to operate high-voltage devices. Operators must also have a complete
understanding of this device’s features and functions.
ATTENTION! Qualified personnel means a person with valid license from the local authority in:
●Installing electrical equipment and PV power systems (up to 1000 V).
●Applying all applicable installation codes and using Personal Protective Equipment.
●Analyzing and reducing the hazards involved in performing electrical work.
WARNING! Do not use this product unless it has been successfully installed by qualified personnel in
accordance with the instructions in chapter 4 “Installation”.
4

1.3 Intended Application
This manual applies to the following products;
●S2.1P-SMARTMETER For 1 phase inverters
Please note that all current inverter models excluding the UX Series are capable of internal power export
limitation using an external current clamp or consumption meter. The internal PELD functionality is only
applicable for systems with one inverter. Please see the relevant inverter series manual for more
information. External power export limitation with the help of the PELD is possible with all inverters.
2. Preparation
2.1 Safety instructions
DANGER! Do not touch any internal components whilst the inverter is in operation.
NOTICE! Do not directly connect AC output of the inverter to any private AC equipment. The PV
inverter is designed to feed AC power directly into the public utility power grid.
WARNING! The installation, service, recycling and disposal of the inverters must be performed by
qualified personnel in compliance with national and local standards and regulations.
Please contact your dealer to get the information of an authorized repair facility for any maintenance
or repairmen.
Any unauthorized actions including modification of product functionality of any form will affect the
validation of warranty service; Autarco may deny the obligation of warranty service accordingly.
5

3. Overview
3.1 Front Panel Display
Figure 3.1: Front display
3.2 LED Status Indicator Lights
There are four LED status indicator lights at the front panel of the consumption meter, as shown in figure
3.1.
Light
Status
Description
Run
GREEN
FLASHING
Device is on
OFF
Device id off
Com
FLASHING
Communication with inverter
OFF
No communication with inverter
R_P
ON
Importing from grid
OFF
Exporting to grid
-
ON
Importing from grid
OFF
Exporting to grid
Figure 3.2: Status indicator lights
6

4. Installation
4.1 Mounting the Consumption meter
The consumption meter needs to be installed in the meter cupboard and can be installed on a 35mm DIN
35 rail.
4.2 Electrical Connections
7

4.3 Wiring
Use port 1 and 4 to supply power to the S2.1P-SMARTMETER.
Connect the meter with the supplied RS485 cable to the meter port of the inverter. You can only use the
RJ45 port for connecting the consumption meter to the inverter.
Install the current clamp on the phase cable that goes to the grid. Note the arrow on the current clamp and
make sure it is installed in the right direction.
8

4.4 Monitoring
In order to get consumption data a WIFI-STICK-D needs to be used, and settings on the inverter need to be
changed.
Use the up and down buttons on the inverter to navigate the menu.
●Go to Advanced settings
●Select 24h Switch
●Set to ON and press ENTER
●Go to Internal EPM set -> Mode Select
●Select Consumption Monitor and press ENTER
●Go to Internal EPM set -> Meter Select
●Select 1PH Meter and press ENTER
●Select ACR10RD16TE and press ENTER
9

5. Specifications
Model name
S2.1P-SMARTMETER
Grid Topology
1P+N
Rated Voltage
220V/230V
Input Current
40mA (External CT: 120A:40mA)
Accuracy
Voltage ±0.2%
Current ±0.5%
Power (P,Q,S) ±0.5%
Active Energy ±0.5%
Reactive Energy ±1%
Operating Temperature
-10°C - 55°C
Relative Humidity
<95% (Non-condensing)
Dimension
45L*85W*64H (mm)
10