Autoquip AQ 3076-AFC3-000 Operation manual

3076-AFCM-000
INSTRUCTIONS – PARTS LIST
Autoquip, Inc.
AQ Air Flow Control
(3076-AFC3-000)
(3076-AFC4-000)
AUTOQUIP, INC.
N57 W13430 REICHERT AVENUE, MENOMONEE FALLS, WI 53051
©COPYRIGHT 2004, AUTOQUIP, INC.
INSTRUCTIONS!
This manual contains important warnings
and information.
READ AND KEEP FOR REFERENCE.
U.S. PAT: 6,874,404; 6,516,707; 6,223,645

2
Table of Contents
Warnings……………………………...2,3 Accessories…..…....……………………....9
Operation……..………………………...4 Dimensions..…….…………………….....10
Installation………………………….…..5 Technical Data...…………………………11
Parts…….……….………………….6,7,8 Warranty…….………...…………………12
Symbols
Warning Symbol Caution Symbol
This symbol alerts you to the possibility of This symbol alerts you to the possibility of
serious injury or death if you do not follow damage to or destruction of equipment if you
the instructions. Do not follow the instructions.
WARNING
CAUTION
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
• This equipment is for professional use only.
• Read all instruction manuals, tags, and labels before operating the equipment.
• Use the equipment only for its intended purpose. If you are not sure, call your Autoquip
distributor.
• Do not alter or modify this equipment. Use only genuine Autoquip parts.
• Check equipment daily. Repair or replace worn or damaged parts immediately.
• Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the
Technical Data section of all equipment manuals. Read the fluid and solvent
manufacturer’s warnings.
• Always wear protective eyewear, gloves, clothing, and respirator as recommended by the
fluid and solvent manufacturer.
• Comply with all applicable local, state, and national fire, electrical, and safety regulations.

3
United States Government safety standards have been adopted under the Occupational
Safety and Health Act. You should consult these standards – particularly the General
Standards, Part 1910, and the Construction Standards, Part 1926.
WARNING
MOVING PARTS HAZARD
Moving parts can pinch or amputate your fingers or other body parts and can cause splashing in the
eyes or on the skin.
• Keep clear of all moving parts.

4
Operation
The AQ Air Flow Control maintains a constant air flow rate by continually
varying pressure based on the pressure drop through an orifice.
To set the air flow control, turn both adjustment knobs 1-2 turns, and turn on
air to the downstream device. Once air flow has begun, adjust the flow
control to the desired rate. Turn off air to the downstream device and set the
soft start control to the desired base pressure.

5
Installation

6
Parts

7
Parts (3076-AFC3-000)
Item PART NO. DESCRIPTION QTY
1 3076-30-36A Piping Adapter 1
2 3076-30-02A Clamp 2
3 3076-30-03A ¼NPT x 5/32 PL fitting 1
4 3076-30-04A T-Fitting 1
5 3076-30-05A 10-32 NPT x 5/32 PL fitting 5
6 3076-40-06A Boost Valve 1
7 3076-30-07A #10-32 Nipple 1
8 3076-30-08A #10-32 Elbow 1
9 3076-30-37A Body 2
10 3076-30-21A Switch/Orifice Body 1
11 3110-B0-008A* -008 Buna-N O-ring 1
12 3076-30-23A Flow Switch Body 1
13 3076-55-__A Orifice (See Page 9) 1
14 3076-40-25A Shoulder Bolt 1
15 3076-30-27A Mounting Clamp 2
16 3076-30-28A Clamp O-Ring 4
17 3076-30-29A* Flow Switch Diaphragm 1
18 3076-30-31A Flow Switch Screw 4
19 3076-30-32A Plug Screw 1
20 3076-30-33A* Plug O-ring 1
21 3076-30-34A* Orifice O-ring 1
22 3076-30-01A Supply control valve (OPTIONAL) 1
* Denotes items included in rebuild kit 3076-AFCR-000

8
Parts (3076-AFC4-000)
Item PART NO. DESCRIPTION QTY
1 3076-40-36A Piping Adapter 1
2 3076-40-02A Clamp 2
3 3076-30-03A ¼NPT x 5/32 PL fitting 1
4 3076-40-04A T-Fitting 1
5 3076-30-05A 10-32 NPT x 5/32 PL fitting 5
6 3076-40-06A Boost Valve 1
7 3076-30-07A #10-32 Nipple 1
8 3076-30-08A #10-32 Elbow 1
9 3076-40-37A Body 2
10 3076-40-21A Switch/Orifice Body 1
11 3110-B0-008A* -008 Buna-N O-ring 1
12 3076-30-23A Flow Switch Body 1
13 3076-55-__A Orifice (See Page 9) 1
14 3076-40-25A Shoulder Bolt 1
15 3076-40-27A Mounting Clamp 2
16 3076-40-28A Clamp O-Ring 4
17 3076-30-29A* Flow Switch Diaphragm 1
18 3076-30-31A Flow Switch Screw 4
19 3076-40-32A Plug Screw 1
20 3076-30-33A* Plug O-ring 1
21 3076-30-34A* Orifice O-ring 1
22 3076-40-01A Supply control valve (OPTIONAL) 1
* Denotes items included in rebuild kit 3076-AFCR-000

9
Accessories
Part # Description
3076-55-02A (Standard 30) Size 1 Orifice ( 1 mm x ½mm )
3076-55-03A (Standard 40) Size 2 Orifice ( 1 mm x 1 mm )
3076-AFCR-000 30 & 40 Series Rebuild kit

10
Dimensions
3076-AFC3-000
3076-AFC4-000

11
Technical Data
Inlet size: 3076-AFC3-000: 3/8” NPT
3076-AFC4-000: 1/2”NPT
Outlet size: 3076-AFC3-000: 3/8” NPT
3076-AFC4-000: 1/2”NPT

12
Autoquip Standard Warranty
Autoquip Inc. warrants all equipment manufactured by Autoquip Inc. and bearings its name to be free from defects in material and
workmanship on the date of sale by an authorized Autoquip Inc. distributor to the original purchaser for use. With the exception of
any special, extended, or limited warranty published by Autoquip Inc., Autoquip Inc. will, for a period of twelve months from the date
of sale, repair or replace any part of the equipment determined by Autoquip Inc. to be defective. This warranty only when the
equipment is installed, operated, and maintained in accordance with Autoquip Inc.’s written recommendations.
This warranty does not cover, and Autoquip Inc. shall not be liable for general wear and tear, or any malfunction, damage, or wear and
tear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident,
tampering, or substitution of non-Autoquip Inc. component parts. Nor shall Autoquip Inc. be liable for malfunction, damage or wear
caused by the incompatibility of Autoquip Inc. equipment with structures, accessories, equipment or materials not supplied by
Autoquip Inc., or the improper design, manufacture, installation, operation or maintenance of structure, accessories, equipment or
materials not supplied by Autoquip Inc.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Autoquip Inc.
distributor for verification of the claimed defect. If the claimed defect is verified, Autoquip Inc. will repair or replace free of charge
any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment
does not disclose any defect in material or workmanship, repairs will be maid at a reasonable charge, which charges may include the
costs o parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A
PARTICULR PURPOSE.
Autoquip Inc.’s sole obligation and buyer’s sole remedy for any breach of warranty shall be set forth above. The buyer agrees that no
other remedy (including, but not limited to incidental or consequential damages for lost profits, lost sales, injury to person or property,
or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2)
years of the date of sale.
Autoquip Inc. makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in
connection with accessories, equipment, material or components sold but not manufactured by Autoquip Inc. These items sold, but
not manufactured by Autoquip Inc. (such as electric motors, switches, hose, etc.) are subject to the warranty, if any, from their
manufacturer. Autoquip Inc. will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Autoquip Inc. be liable for indirect, incidental, special or consequential damage resulting from Autoquip Inc.
supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether die to
breach of contract, breach of warranty, the negligence of Autoquip Inc., or otherwise.
FOR AUTOQUIP, INC. CANADA CUSTOMERS
The parties acknowledge that they required that the present document, as well as all documents, notices and legal proceedings entered
into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent
avoir convenu que la rèdaction du prèsente document sera en Anglais, ainsi que tous documents, avis et procèdures judiciaries
exècutès, donnés ou intentés á la suite de ou en repport, directement ou indirectement, avec les procedures concernées.
Autoquip Phone Numbers
TO PLACE AN ORDER, contact your Autoquip distributor, or call this number to identify the distributor closest to you :
(262) 781-6133
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Autoquip reserves the right to make changes at any time without notice.
Sales Offices : MENOMONEE FALLS, WI (262) 781-6133
AUTOQUIP, INC. N57 W13430 REICHERT AVENUE MENOMONEE FALLS, WI 53216
http://www.aqautomation.com
PRINTED IN USA March 2004
This manual suits for next models
1
Table of contents
Popular Control System manuals by other brands

Almot
Almot 08880892 Installation and use manual

Norac
Norac UC5 Topcon X30 installation manual

Cardin Elettronica
Cardin Elettronica EL Series instruction manual

Phoenix Contact
Phoenix Contact TP 6000 HMI user manual

Steril-Aire
Steril-Aire UVC Controller II Installation and operation manual

Raven
Raven RS1 Calibration and Operation Manual