ZKTeco CMP-200 Series User manual

Thank you for choosing our product. Please read the instructions
carefully before operation. Follow these instructions to ensure that the
product is functioning properly. The images shown in this manual are for
illustrative purposes only.
For further details, please visit our Company’s website
www.zkteco.com.
User Manual
CMP-200
Date: March 2020
Doc Version: 1.1
English

Table of Contents
1 Product Introduction............................................................................................- 1 -
2 Appearance and Dimensions............................................................................... - 1 -
3 Product Installation.............................................................................................. - 2 -
3.1 Installation Precautions..............................................................................- 2 -
3.2 Cable Embedding......................................................................................- 3 -
3.3 Boom Installation.......................................................................................- 4 -
4 Parameters............................................................................................................- 5 -
5 Functions..............................................................................................................- 6 -
6 Movement Transmission Structure.......................................................................- 7 -
7 Control Board Wiring Installation..........................................................................- 8 -
8 Commisioning Instructions................................................................................ - 12 -
9 Troubleshooting................................................................................................. - 15 -
10 Packing List.......................................................................................................- 16 -

- 1 -
1 Product Introduction
CMP-200 series automatic barrier gate is a new barrier gate product combined with
the practical application of automatic barrier gate products in the industry. Its
appearance and structure design follows the needs of the market and industry, and
the traffic light indication has the humanized experience. As an economical
automatic barrier gate product, users can match the telescopic straight boom
according to the actual needs to meet different application scenarios.
2 Appearance and Dimensions

- 2 -
3 Product Installation
3.1 Installation Precautions
1) Install the parking barrier on a level ground. If the ground is not solid and level,
a cement base is needed before installation.
2) The boom can be cut, but cannot be increased. After cutting the boom length,
L: The cabinet on the left
R: The cabinet on the right

- 3 -
the spring balance needs to be set again to achieve new balance. Two plastic
nuts lie in the bottom of the spring is designed for adjusting new balance.
3) Do not change the wire connection inside when power on.
4) The GND should be connected to the cabinet for secure protection.
3.2 Cable Embedding
1) Prepare φ25 protective sleeve and cable in advance.
2) Route cables to be connected through protective sleeves.
3) Use a tool to open a cable tray on the ground.
Control
room
Screw pad
Ground
Cabinet
Expansion bolt
4-M12
Ground
Base concrete
A standard power wire RVV3*1.0
A signal line RVV4*0.5
The power wire is wrapped
and protected using the wire
sleeve when laid out under
the ground (the strong
current should be separated
from the weak current)

- 4 -
3.3 Boom Installation
Boom Installation Procedure
1) Pull the vice boom out from the main boom, then fastened by 2 screws, as
shown in Figure 1.
2) Installing the boom to the chassis, as shown in Figure 2.
Figure 1 Connect the main boom with vice together by 2 screws
Figure 2 Installing the Boom to the Chassis

- 5 -
4 Parameters
Power adaptability
Input voltage AC 220V/110V±20%, 50/60Hz
Rated power
100W
Max power
120W
Remote control
distance
Open field≤30m
Remote control
frequency
430MHZ, Learning code
Chassis material
Cold gadolinium steel plate
Boom material
Aluminum
Working
temperature
-25℃~+75℃
Working humidity
<90%RH (no condensation)
Protection grade
IP54
Shell size (W*D*H)
1010*350*280 (mm)
Package size
(W*D*H)
1100*375*430 (mm)
Chassis net weight
45KG

- 6 -
Chassis gross weight
47KG
Boom type
(The mainboard is
the same)
Telescopic straight boom, boom length≤4.5m, red and
white color, the rise/fall speed is 3s
Telescopic straight boom, boom length: 4.5m~6m, red and
white color, the rise/fall speed is 6s
5 Functions
1. The opening and closing angle is 90°±2°.
2. Up, down and stop interfaces with standard switch input.
3. Anti-smash function: support loop detector, infrared detector and radar
functions.
4. Controller timeout protection: when the boom operation is abnormal and
exceeds the rise and fall time, the boom will stop operation automatically.
5. The barrier gate can be controlled by wireless remote control and wired
control button to meet the needs of different field applications.
6. It supports traffic lights with AC voltage, and DC voltage of 5V or 12V.
7. Mainboard built-in fuse, overvoltage protection.
8. Support the connection of LPR, UHF reader controller and other devices to
recognize and control the automatic door opening.

- 7 -
6 Movement Transmission Structure

- 8 -
7 Control Board Wiring Installation
1. Remove the wiring cover of the barrier gate main controller.
2. Refer to the wiring diagram of the barrier gate controller and connect the lines
one by one firmly. (Note: Power must be disconnected before installation or
maintenance.)
3. After checking and confirming reliable wiring, install the wiring cover back.
4. Install the desktop remote control. Place the desktop remote control on the
desk in the guard room or attach it to the wall and plug in power.
5. The wiring diagram of the controller is as follows:

- 9 -

- 10 -
Connection with LPR camera:
Connection with UHF controller (Note: The Reader1 and 2 of inbio260
controller are corresponding to LOCK1, Reader3 and 4 are corresponding to
LOCK2):

- 11 -
Connection with loop detector:
Connection with infrared detector:

- 12 -
8 Commisioning Instructions
1. Check all the connections and make sure the connections are correct before
connecting the power.
2. Please use the remote control or press the switch button on the mainboard to
test whether the machine is running normally. Warning: Be sure to install the
corresponding length of boom before power-on test. To avoid accidents,
no one is allowed to stand under the boom during debugging.
3. In the process of boom falling, short connect the infrared detector and public
interface, the falling boom is transferred to rising immediately, which will stop
automatically after the rising limit.
4. In the process of boom falling, short connect the loop detector and public
interface, the falling boom is transferred to rising immediately, which will fall
automatically after the rising limit and stop automatically after the falling limit.
In the process of boom rising, short connect the loop detector and public
interface, the boom will fall automatically after the rising limit and stop
automatically after the falling limit. In the open state, short connect the loop
detector and public interface, the boom will automatically fall to the limit and
stop.

- 13 -
5. Barrier gate Hall limit switch adjustment:
6. Left and right movement interchange method:
7. Barrier gate spring and boom length type matching:

- 14 -
8. Study/delete remote control code
Study code: In the stop state, press the“Study”button on the main controller until
the REMOTE indicator is on then release it, press any button on the remote control,
the REMOTE indicator is off, and the code studying is completed.
Delete code: In the stop state, press the “Study”button on the main controller until
the REMOTE indicator is on, continue to press and hold the“Study”button until the
REMOTE indicator is off, and the code deletion is completed. (Note: All codes are
deleted.)
Note: One barrier can only study to 20 remote controls. The matching remote
control has been learned, there is no need to learn again.

- 15 -
9 Troubleshooting
No.
Troubles
Fault cause
Solution
1
The POWER indicator is not on,
the button is not responding.
1. The power supply is
not connected.
2. The fuse blew.
1. Connect the
power.
2. Replace the
fuse.
2
The POWER indicator is on, no
response by remote control.
1. Remote control
code is wrong.
2. Poor receiving
module.
3. Same frequency
interference exists.
1. Recode.
2. Replace
receiving module.
3. Change other
frequency.
3
The POWER indicator is on,
boom UP and DOWN indicator
is normal, the motor is not
running.
1. The motor wire is
open or connected
incorrectly.
2. Motor is stuck.
1. Connect the
motor wire.
2. Manual release
motor.
4
Unable to rise or fall boom to
limit.
1. The limit line is
misconnected.
2. Limit switch broken.
1. Reconnect the
rising and falling
limit line.

- 16 -
2. Replace limit
switch.
5
Remote control handle is not
responding.
1. The battery of the
handle is low.
2. Handle broken.
1. Replace battery.
2. Replace the
handle.
10 Packing List
1) The barrier gate*1
2) The boom*1
3) The remote control*2
4) The barrier fixed screw*4
5) The boom fixed plate*1
6) The boom fixed screw*2
7) The key*2
8) The user manual*1

- 17 -
ZKTeco Industrial Park, No. 26, 188 Industrial Road,
Tangxia Town, Dongguan, China.
Phone: +86 769 - 82109991
Fax : +86 755 - 89602394
www.zkteco.com
Copyright©2019 ZKTECO CO., LTD. All rights reserved.