manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AWS
  6. •
  7. Scale
  8. •
  9. AWS CARD-V2 User manual

AWS CARD-V2 User manual

This manual suits for next models

2

Other AWS Scale manuals

AWS KG-Series User manual

AWS

AWS KG-Series User manual

AWS AMW-810 User manual

AWS

AWS AMW-810 User manual

AWS CBS-330 User manual

AWS

AWS CBS-330 User manual

AWS TL-330 (330lb x 0.2lb) User manual

AWS

AWS TL-330 (330lb x 0.2lb) User manual

AWS 330LPW Assembly instructions

AWS

AWS 330LPW Assembly instructions

AWS SG-300 User manual

AWS

AWS SG-300 User manual

AWS CUBE-100 User manual

AWS

AWS CUBE-100 User manual

AWS BLADE V2 BL2-50 User manual

AWS

AWS BLADE V2 BL2-50 User manual

AWS MC series User manual

AWS

AWS MC series User manual

AWS OM-200 User manual

AWS

AWS OM-200 User manual

AWS ACP-200 User manual

AWS

AWS ACP-200 User manual

AWS 330HRS User manual

AWS

AWS 330HRS User manual

AWS CP2-300 User manual

AWS

AWS CP2-300 User manual

AWS xp150 User manual

AWS

AWS xp150 User manual

AWS AMW-440T User manual

AWS

AWS AMW-440T User manual

AWS AWS-70 User manual

AWS

AWS AWS-70 User manual

AWS CV-100 User manual

AWS

AWS CV-100 User manual

AWS AMS-150 User manual

AWS

AWS AMS-150 User manual

AWS ZT-150 User manual

AWS

AWS ZT-150 User manual

AWS CP5-100 User manual

AWS

AWS CP5-100 User manual

AWS AERO-100 User manual

AWS

AWS AERO-100 User manual

AWS AT-500 User manual

AWS

AWS AT-500 User manual

AWS DK-5K User manual

AWS

AWS DK-5K User manual

AWS 5K-BOWL User manual

AWS

AWS 5K-BOWL User manual

Popular Scale manuals by other brands

KERN MCC-M operating instructions

KERN

KERN MCC-M operating instructions

Little Balance SB MECA 8113 user manual

Little Balance

Little Balance SB MECA 8113 user manual

Fitbit Zip Aria Wi-Fi Smart Scale user manual

Fitbit Zip

Fitbit Zip Aria Wi-Fi Smart Scale user manual

KERN MPU 250K100 operating instructions

KERN

KERN MPU 250K100 operating instructions

Steinberg Systems SBS-PF-200 user manual

Steinberg Systems

Steinberg Systems SBS-PF-200 user manual

Total TP2000 user guide

Total

Total TP2000 user guide

A&D HL-200i operating instructions

A&D

A&D HL-200i operating instructions

OHAUS Courier 3000 user guide

OHAUS

OHAUS Courier 3000 user guide

Scarlett SC-KS57P97 instruction manual

Scarlett

Scarlett SC-KS57P97 instruction manual

BASETech LS-40S operating instructions

BASETech

BASETech LS-40S operating instructions

SR Instruments SR Scales SR565i-H Operating and service manual

SR Instruments

SR Instruments SR Scales SR565i-H Operating and service manual

Gallet PEP 301ART instruction manual

Gallet

Gallet PEP 301ART instruction manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

EDLUND BBPZ-20 quick start guide

EDLUND

EDLUND BBPZ-20 quick start guide

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

IKA RCT basic safety control operating instructions

IKA

IKA RCT basic safety control operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CARD-V2-100
CARD-V2-600
User Manual
CARD-V2
Copyright © 2010 American Weigh Scales, Inc.
All rights reserved. Rev. 2.0
CARD-V2 Scale
Thank you for purchasing the American Weigh
CARD-V2 digital pocket scale. Please read all operating
instructions carefully before use. Scales are precision
measuring devices and should always be handled with
proper care. To ensure years of reliable service, keep these
simple tips in mind:
• Do not exceed the scale’s maximum capacity.
Overloading your scale can permanently damage it!
• Avoid exposure to extreme heat or cold. Scales
perform best at normal room temperature. If
temperatures have changed dramatically, calibration
and adjustment may be necessary.
• Allow your scale to warm up for 30-60 seconds before
performing calibration and adjustment(if available).
• Store your scale in a clean, dry location. Dust, dirt,
and moisture can accumulate on the weighing
sensors and electronics causing inaccuracy or
malfunction.
• Avoid using your scale in close proximity to strong
radio wave emitting devices such as computers, cash
registers, and cordless phones.
• Alwaysweighonaatandlevelsurface,freefrom
vibrations and drafts. The corner of a room is usually
the most stable.
• Gently apply all items to be weighed. Do not drop
items onto the weighing platform.
• Avoid dropping your scale. The warranty does not
cover damage due to rough treatment or overload.
• Checkthebatteriesrstifyouarehavinganytrouble
with your scale. This simple step can remedy most
scale issues.
• Do not disassemble your scale. This product contains
no user serviceable parts.
I. Part List
1. Scale
2. Cover/Expansion Tray
3. AAA Batteries (x2)
II. Key Description
III. Battery Installation
1. Beforeusingthescaleforthersttime,check
the battery compartment and remove any plastic
insulation strips or packaging that may be in place to
prevent battery drainage during shipping/storage.
2. If you are replacing the batteries, make sure the
positive and negative contacts are properly aligned.
Mode Key
Tare Key
Weight Indicator
ON/OFF Key
g
TARE MODE ON/OFF
TM
CARD-V2 Scale
IV. Operation
1. Placethescaleonaat,levelsurfaceandpressthe
ON/OFF key to turn the scale on.
2. Once the start-up process completes and the scale
goes to zero you are ready to weigh.
3. Place the quantity to be weighed onto the weighing
platform.
4. Wait a couple seconds for the display to stabilize
before taking a weight reading.
V. Changing the Unit of Measure
1. Press the MODE key to change the scales displayed
unit of measure.
2. If the scale is turned off then back on, it will default
to the last unit used.
• CARD-V2-100 Units: g (gram) oz (ounce) ct
(carat) gn (grain)
• CARD-V2-600 Units: g (gram) oz (ounce) ozt
(troy ounce) dwt (pennyweight)
VI. Using the Tare Feature
You can use this scale’s tare feature to subtract the weight
of an empty container or vessel for net weight determination.
NOTE: The weight of the container will subtract from the
available capacity.
1. Place the empty container or vessel on the weighing
platform.
2. Press the TARE key once. The display will then
reset to zero. If the container is removed, it’s weight
will be displayed as a negative number.
3. Youmaynowllthecontainerwiththequantityto
be weighed. The display will show the net weight of
the contents.
4. To return to normal weight display (gross weight),
remove any items from the weighing platform and
press the TARE key again to re-zero the scale.
VII. Calibration
Calibration and adjustment are performed at the factory.
However, the weighing range can shift slightly during
shipping. Also, due to changes in local acceleration of gravity
around the world, adjustment is recommended when moving
the scale from one location to another. To check calibration:
1. Place the required calibration weight on the scale
and note the displayed value.
2. If the displayed value is not within acceptable
tolerance (see chart below), adjustment is required.
Model Acceptable
Tolerance (±)
Calibration
Weight
Recommended
Accuracy Class
CARD-
V2-100
0.02g 100g OIML M2
CARD-
V2-600
0.2g 500g OIML M2
VIII. Adjustment
1. Press and hold the MODE key until the display
shows “CAL”.
2. Press the MODEkeyagain.Thedisplaywillash
“CAL” followed by the calibration weight value (see
chart).
3. Place the calibration weight on the center of the
weighing platform. Make sure you are using the
correctweightforyourspecicmodel.
CARD-V2 Scale
4. Once the weight is accepted, the display will show
“PASS” then return to normal operation.
IX. Troubleshooting
• Problem: Scale will not turn on
• Solution: Check the batteries
• Problem: Displayedweightuctuatesrandomly
• Solution: Make sure your workspace is stable and
free of any air currents or vibration
• Problem: Displayed weight is inaccurate
• Solution: Perform a calibration adjustment
X. Error Codes
1. OUTZ - Zero range has shifted. Perform calibration
adjustment. If the problem persists, the load cell may
be permanently damaged due to overloading.
2. O-Ld - Maximum capacity exceeded. Remove the
extra weight to avoid damaging the load cell.
3. L - Batteries are low. Replace the batteries.
XI. Specications
CARD-V2-100 CARD-V2-600
Max. Capacity 100g 600g
Readability 0.01g 0.1g
Min. Weight 0.03g 0.2g
Power 2 x AAA
Dimensions 0.8 x 3.0 x 4.1”
Platform Dimensions 1.9 x 3.5”
XII. Capacity/Readability Charts
CARD-V2-100 CARD-V2-600
100g x 0.01g
3.528oz x 0.001oz
500ct x 0.05ct
1543gn x 0.1gn
600g x 0.1g
21.16oz x 0.01oz
19.29ozt x 0.01ozt
385.8dwt x 0.1dwt