AXA entrya Facila User manual

Installation Guide 2017Facila

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
2
Index
Preface 3
Legend 3
Notions 3
Cabling requirements VILLA system 5
Topology: Cascade network 5
Topology: Star network 6
Example schematics 7
Basic schematic 7
Basic schematic with lock module 7
Multiple door stations with a distributor 7
Multiple monitors with a distributor 7
Multiple monitors with a distributor in combination with a telephone-interface 7
Multiple monitors with distributor in combination with a lock module 8
Multiple monitors with multiple distributors 8
Camera module 9
Multiple door stations and a lock module with a distributor 9
Cabling requirements APPARTMENT system 10
Topology: Star network 10
Topology: Cascade netwrk 11
Example schematics 12
Basic schematic 12
Basic schematic with lock module 12
Multiple door stations with distributor 12
Multiple monitors with distributor 12
Multiple monitors with a telephone interface and a distributor 12
Multiple monitors with a lock module and a distributor 13
Multiple monitors with multiple distributors 13
Camera module 14
Multiple door stations with lock module and distributors 14
Using a supplementary power supply 15
Overview installation codes FP070 / FP035 16
Frequently Asked Questions 16

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
3
Preface
The FACILA-system is designed with a focus on usability. A two-wiresystem that is not sensible to
polarity, guarantees a quick and easy installation.
The multi-use of our monitors ensures an answer for every installation. Call forwarding, videosur-
veillance, mobile forwarding, standard and panic-lock activations and controlling gate operators,
FACILA has quick solutions for every case.
This guide is a supplement to the manuals of the monitors, doorstations and accessories
and does not replace the actual manuals!
Team Entrya!
Legend
Doorstation Monitor Accessory
PSU
Notions
BUS system
A ‘BUS’ is a signalline which has multiple devices connnected parallel. The purpose is to diminish
the number of connections between devices. In a FACILA-BUS the data-, audio-, power- and vide-
osignals have been integrated on two wires. When a connected device on a BUS wants to commu-
nicate with another device on the same BUS, it can only do so when the signalline is not occupied.
The device will put the address of the device it searches on the BUS so that it is clear which device
is requested. Giving each device a correct address is therefore very important.
Model Master/Slave
In a Master/Slave setup one device controls all other. The Master receives the call from the
doorstations and redistributes the signals to possible Slave-monitors with the same address. An
installation has at least one Master-monitor.
Schematic overview of a Master/Slave setup
Master
Address 0
Address 1
Master
Slave 1
Slave 1
Slave 2
Slave 2
00.00
01.00
00.10
01.10
00.20
01.20
The Master/Slave setup is default because it groupes several monitors to one address.
This makes it possible to have up to 4 monitors for each installation (1x Master and 3x Slaves).

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
4
Terminating resistor
A terminating resistor will close the BUS-signalline. This closure ensure that reections of signals
are minimized. When a BUS-line is not closed, interferences in video, audio and data-communicati-
on may occur which will disturb the functioning of the system.
This ‘impedance switch’ is switched on at the monitor and distributor which are last
on the BUS-line.
Double twisted cable
Connect half-colored wires and full-colored wired to twist twisted wires.
Use the brown and orange pair on CAT5-cable!
Limiting risks when connection a lock
Use the lock connections of a FACILA doorstation and lockmodule only for entrances which do not impose a
securitythreat when an unauthorized entry occurs.
Important!
Never connect the shielding a cable!
Important!
Entrya BVBA does not guarantee any burglary resistance.
OK WRONG
Brown
Brown/White
Orange
Orange/White
BUS - BUS -BUS + BUS +

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
5
Cabling requirements VILLA system
The maximum length of cabling is limited. The use of other cables then subscribed could inuence
the maximum length of cabling and cause interferences.
Up to 2 monitors in the installation A B
UTP Cat5 40m 80m
2 wires without shielding (2x 0.75mm²) ** 30m 50m
Twisted pair without shielding (2x 0.75mm²) 60m 100m
Twisted pair without shielding (2x 1mm²) 80m 120m
Upward of 2 monitors in the installation A B
Twisted pair without shielding (2x 0.75mm²) 60m 40m
Twisted pair without shielding (2x 1mm²) 80m 60m
A: Maximum cable length between PSU and door station
B: Maximum cable lenght between PSU and the last monitor
A B
Topology: Cascade network
In a serial network all devices are connected on one BUS-line. This makes a serial network usable
for new building projects. This network ensures less cabling then a star network but ‘local’ pro-
blems will inuence the entire network.
PSU
Important!
Switch terminating resistance ON on accessories and monitors with this symbol.
**
Non-twisted cable is sensible to disturbances! Interferences could occur in video and audio
when cabling is placed to close to other electromagnetic elds (ex. microwave, television,
computer,..).
Twisted cable is the only advised cable!

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
6
Topology: Star network
Less than 20 monitors in the installation A B C
Twisted pair without shielding (2x 0.75mm²) 60m 60m 30m
Twisted pair without shielding (2x 1mm²) 80m 80m 40m
A: Maximum cable length between PSU and door station
B: Maximum cable length between PSU and the last distributor
C: Maximum cable
length between
distributor and the
last monitor.
B
C
In a star network all devices communicate through distributors. The advantage of such a star topo-
logy is that ‘local’ problems are contained and do not inuence the entire network. Star networks
are very adequate for renovating projects where an existing intercom has to be exchanged. A star
network requires more cabling than a serial network.
PSU Distributor Distributor
A
Important!
Switch terminating resistance ON on accessories and monitors with this symbol.

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
7
Important!
The telephone interface has address 15, no other device may have this address!
Example schematics
Basic schematic
Basic schematic with lock module
Multiple door stations with a distributor
Multiple monitors with a distributor
Multiple monitors with a distributor in combination with a telephone-interface
PSU
PSU
PSU
Distributor
DistributorTelephone
interface
Distributor
PSU
PSU
Lock module

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
8
Multiple monitors with distributor in combination with a lock module
Multiple monitors with multiple distributors
PSU
PSU
DistributorLock module

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
9
Camera module
PSU
Multiple door stations and a lock module with a distributor
PSUDistributor
Lock module

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
10
Cabling requirements APPARTMENT system
Topology: Star network
The maximum length of cabling is limited. The use of other cables then subscribed could inuence
the maximum length of cabling and cause interferences.
Up to 20 monitors in the installation A B C
Twisted pair without shielding (2x 0.75mm²) 60m 60m 30m
Twisted pair without shielding (2x 1mm²) 80m 80m 40m
Upward from 20 monitors in the installation A B C
Twisted pair without shielding (2x 1mm²) 70m 30m 20m
Twisted pair without shielding (2x 1.5mm²) 70m 50m 30m
A: Maximum length between PSU and door station
B: Maximum length between PSU and the last distributor
C: Maximum length
between distributor
and the last monitor
A
B
C
In a star network all devices communicate through distributors. The advantage of such a star topo-
logy is that ‘local’ problems are contained and do not inuence the entire network. Star networks
are very adequate for renovating projects where an existing intercom has to be exchanged. A star
network requires more cabling than a serial network.
PSU Distributor Distributor
Important!
Switch terminating resistance ON on accessories and monitors with this symbol.

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
11
Topology: Cascade netwrk
In een serienetwerk zijn alle posten met elkaar verbonden op één Bus-lijn. Een serienetwerk is dan
ook geschikt voor nieuwbouwprojecten. Een serienetwerk vereist minder kabels dan een
sternetwerk maar bij problemen wordt het volledige netwerk verstoord.
A: Maximum length between PSU and door station
B: Maximum length between PSU and the last monitor
Less than 16 monitors in the installation A B
Twisted pair without shielding (2x 0.75mm²) 60m 40m
Twisted pair without shielding (2x 1mm²) 80m 60m
A
B
Voeding

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
12
Important!
The telephone interface has address 15, no other device may have this address!
Example schematics
Basic schematic
Basic schematic with lock module
Multiple door stations with distributor
Multiple monitors with distributor
Multiple monitors with a telephone interface and a distributor
PSU
PSU
PSU
Distributor
DistributorTelephone
interface
Distributor
PSU
PSU
Lock module

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
13
Multiple monitors with a lock module and a distributor
Multiple monitors with multiple distributors
PSU
PSU
DistributorLock module
Important!
Switch terminating resistance ON on accessories and monitors with this symbol.

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
14
Camera module
PSU
Multiple door stations with lock module and distributors
PSUDistributor
Lock module

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
15
Using a supplementary power supply
When on one signal line more than 8 monitors are installed, a supplementary PSU is advised.
This extra PSU is installed at the end of the BUS-line to guarantee that the required tension
does not go below 23V DC.
Before installing a supplementary PSU it is important that one measures the tension on
the BUS when a monitor is communicating with a door station. Dene polarity of the
wires and respect the polarity when installing;
connect the positive from the supplementary PSU with the positive from the BUS-line.
Remove jumper CN2 on the
supplementary PSU

All texts and images in this guide are protected by copyright and intellectual property of ENTRYA BVBA.
v1710v31
16
Overview installation codes FP070 / FP035
Description Code FP070 FP035
Restore factory settings 2412
Erase Memory 2499
Update Firmware 2810
User Interface Update 2811
Update Tunes 2812
Format SD-card 2813
Send adjusted namelist to other monitors 2910
Congure monitor as Master 8000
Congure monitor as Slave 1-3 8001-8003
Congure Guard monitor (8004) or deactivated (8005) 8004-8005
Video active on slaves when calling (8006) or deactivated (8007) 8006-8007
Date format: MM//DD/YYYY (8008) of DD/MM/YYYY (8009) 8008-8009
Lock output as Normally Open (8010) or Normally Closed (8011) 8010-8011
Time format: 12-Hr (8012) or 24-Hr (8013) 8012-8013
Unlocking menu active (8014) or deactivated (8015) 8014-8015
Monitor not available when BUS is active (8016) or available (8017) 8016-8017
Videoformat: Automatic (8018), PAL (8019) or NTSC (8020) 8018-8020
Unlocking time between 1-9 s 8021-8029
Indicating light will light up in red, green, blue, yellow or purple when calling 8040-8044
Indicating light will blink red, green, blue, yellow, purple or white when
calling
8045-8050
Indicating light will blink red, green, blue, yellow, purple or white in standby 8051-8056
Indicating light is deactived 8057
Automatic recording is active (8300) or deactivated (8301) 8300-8301
Manual recording possible (8302) or deactivated (8303) 8302-8303
Unlocking time between 1-99 seconds 8401-8499
Warning during unlocking (9006: OFF, 9007: ON) 9006-9007
Tune Type (9008: Auto, 9009: Default, 9010: Reserved) 9008-9010
Start namelist from 0 (9011) or 1 (9012) 9011-9012
Touchscreen tap sounds active (9013) or deactivated (9014) 9013-9014
Intercomcall possible (9015) or deactivated (9016) 9015-9016
Congure sensibility of the touch screen 9017-9019
Hearing Aid function (T-coil) (Not available) 9020-9021
Zoomfactor when using sheye-objective 9030-9039