Axelent Storeroom X-It Electric F User manual

AXELENT AB • BOX 1
KÄVSJÖVÄGEN 17 • SE-335 73
HILLERSTORP • SWEDEN
TEL +46 (0)370-37 37 30
INFO@AXELENT.SE
WWW.AXELENT.COM
Storeroom
X-It Electric F/FK
C-0016389-01, C-0016390-01 | 2210 X-It Electric X-Guard Assembly Guide
XIT-L/R09-103, XIT-L/R09-104

Axelent X-Guard | 2/7www.axelent.com
F: XIT-L/R09-103
FK: XIT-L/R09-104
XIT-001-103
XIT-001-104
XIT-009-001
B00-022XIT-L/R09-000
X 1
X 1
X 1
X 1
X 1
X 1
X 1
X1
X 4
X 1
X 1
X 2
CL0093
CL0047
CL0046
XIT-L/R09-000
10-9745 10-9750
CL0086
CL0035-EL CL0062
CL0045-EL CL0061
CL0016
MK6S-M3.14
CL0019
LM6M-M3
MF6S-M8.35
B-504
G2017
MRTGF-M5.8
G2017-4
X 1
X 1
X 1
X 1
X 1
X 2
T01-46P
X1
X 1
X 1
X 1
X 1
X 1
X 1
X 5
X 1
X 3
G2270 G2271 G2272-1 G2273 G3047G2274 G2275
G2276-4
G2276-4
B00-065
X 4
CL0082 CL0081
X 5
F:
FK:
PH2
2.5 /5 mm
T25
B00-064
OPTIONAL
MRTGF-M5.8
X 5
MK6S-M3.14
X 5
G2276-4
X 1

3
Axelent X-Guard | 3/7www.axelent.com
1
CL0016
XIT-L/R09-000
CL0019
CL0019
CL0047
CL0046
2
T25
X-100 mm
X
G2276-3
F:
FK:
10-9540
10-9550

Axelent X-Guard | 4/7www.axelent.com
G2273
G2272-1
10-9745
G3047
G2270
PH2 T255 mm
10-9750
4
Cable:
G2276-3
G2274
G2274
G2017-4
G2017-4
10-9745
10-9745
CL0045-EL
CL0035-EL
G2276-3
G2276-3
G2275
G2275
5
CL0093
LM6M-M3
CL0086
MRTGF-M5.8
MK6S-M3.14
T25 2,5 mm
F:
FK:
G2271

FK:
Axelent X-Guard | 5/7www.axelent.com
6
F:
5 mm
CL0062
CL0061
G2017
G2017

Axelent X-Guard | 6/7www.axelent.com
Electrical Characteristics
Supply voltage 12-24VDC +/-10% (Regulated)
Quiescent supply current 30-50 mA
Reverse supply voltage protection Yes
Inputs
Type Optoisolated
Isolation voltage 1500V
Active voltage 12-24V DC
Active current 5 mA
Max curent 20 mA
Timing
Unlocking/locking response time 0.1 sec
Outputs (semiconductor)
Type P-channel FET driver
Output voltage Vin (input voltage)
Max load per output 250 mA
Min load per output 10 mA
Short circuit proof Yes
Technical Specifications
Enviromental data
Storage temperature -25- +70 °C according to IEC 60068-2-14
Operating temperature -10- + 70 °C according to IEC 60068-2-14
Housing IP rating IP21 according to EN 60529:1991 + A1:2000 + A2:2013. IEC 60529:1989
+ A1:1999 + A2:2013
Performance
Number of unlocking/locking operations Tested to 100 000
Durability According to SS EN 12209
EMC
EN 55022:2010 EN 61000-6-2:2005/C1:2005,
EN 61000-6-3:2007 EN 301 489-1 V1.9.2 (2011-09),
EN 55024:2010 EN 301 489-17 V2.2.1 (2012-09)
EN 61000-6-2:2005
Mechanical data
Holding force locking mechanism 3 kN
Connector type M12 8-pin male connector
Cable LiYY 8 x 0.25 mm2
Housing material Zinc
Mounting plates material DC01
Blocking mechanism material Zamak5
Weight 2230 g
Indications
Lock state LED Comment
Electrically unlocked, REN/REX signal active steady Green
Electrically unlocked, door open, Flashing Green Indicates that the unlock-signal is not
REN/REX signal not active active while the door has not been closed.
Locked with door closed steady Red
Locked with door open Flashing Red Indicates that the lock has lost the door
closed position.
Manually unlocked (Key) steady Yellow
Manually unlocked, door open Flashing Yellow *
Manually indeterminate position (steady Yellow) Indicates that lock is neither in locked nor
unlocked position.
Electric lock failure Flashing Red / steady Red Indicates failure to lock or unlock
(3 sec intervals) electrically.
Terminology
REX Request to exit (input)
REN Request to enter (input)
Latched The electrical latch is latched (the mechanical lock can still be unlocked).
Unlatched The electrical latch is unlatched (lock is unlocked)
Locked The lock is mechanically and electrically locked/latched.
Unlocked The lock is mechanically unlocked or electrically unlatched.
Active A voltage is present on the input or output.
Inactive No voltage is present on the input or output.
• UNLOCKING. When voltage is applied to REN/REX input, the lock will unlatch electrically. The LED will indicate
unlocked state with a steady green light.The lock will remain in unlatched state until REN/REX input voltage is
removed. If the door is not closed when the REN/REX input is released, the lock will remain unlatched until the door is
closed (indicated by a flashing red light).
The lock can also be mechanically unlocked using a key or by using the rear green escape knob.
NOTE! When unlocking mechanically, the LED will indicate steady yellow. By this operation the
electronically function is deactivated, until one manually lock by the key, or reset by the knob.
Plastic caps are available as spare part by art. no. B00-064.
It’s recommended that the master key is handled by the responsible person for the lock system,
solely.
• LOCK STATUS LOCKED. The LSL output is active when the lock is completely locked, both mechanically and
electrically. This output is independent of the door position.
• LOCK STATUS UNLOCKED. The LSU output is active when the lock is mechanically unlocked or electrically unlatched.
This output is independent of the door position.
• DOOR STATUS. The DS output is active when the door is closed.
Function description

Axelent X-Guard | 7/7www.axelent.com
Pin functions
Pin Signal Signal level Color Function
1 LSU 0V=Not unlocked. Vin=Unlocked White Lock status unlocked
2 LSL 0V=Not locked. Vin=Locked Brown Lock status locked
3 DS 0V=Door open. Vin=Door closed Green Door status
4 IN-X2 - Yellow Not used
5 IN-X1 - Gray Not used
6 REN/REX 0V=Locked. Vin=Unlocking request Pink Request to enter/exit
7 0V - Blue Supply 0VDC
8 Vin - Red Supply 12-24VDC
Installation may only be carried
out by duly qualified personnel
Please note the wiring of the
lock, due to no standardisation
of 8-pole sockets core colors.
12-24VDC
0VDC
8
7
Vin
0V
Supply
6
REN/
REX
Supply
Inputs
5
IN-X1
4
IN-X2
Outputs
Red Pink Gray Yellow
Blue
3
DS
Green
2
LSL
Brown
1
LSU
White
Lock controller/
Connected load
(Driving a relay or other inductive load
requires a protection diode)
Lock controller
12-24VDC
0VDC
Warranty and liability
All claims to warranty and liability will be rendered invalid if
• The product was used contrary to the purpose for which
it is intended
• Damage can be attributed to not having followed the
guidelines in the manual
• Installer personnel are not suitably qualified
• Any type of modification has been made (e.g. exchanging
components on the PCB boards, soldering work etc.).
• Do not disassamble the product
• Lubrication of internal parts must not occur
Visit www.axelent.com for more information
This manual suits for next models
3
Table of contents
Other Axelent Lock manuals
Popular Lock manuals by other brands

SMONET
SMONET SMUS-GS001 manual

Sygonix
Sygonix 2380478 operating instructions

Yale
Yale eBOSS E5400LN Series installation instructions

BEST ACCESS SYSTEMS
BEST ACCESS SYSTEMS 75KC installation instructions

Stock Loks
Stock Loks C8803 instruction sheet

Simply Elegant
Simply Elegant TM Patio Lockset Series instructions