Connection
Connector Function
1-2 Power supply 10-40VDC or 8-35VAC
3-4 Relay output
5-6 Not used
7-8 Timer input
Closing of connector 7 and 8 disables
CODE 3
.
9-10 Exit button
Depending on type of lock connected to the A04, the supply voltage may need to be increased.
Check voltage at lock if the lock is stoll locked after entering a valid code.
Programming
1. Enter programming mode
Programming mode
lAt power up, the unit enters programming mode automatically when the frame is
closed.
lAfter a valid access, either by code or exit button, the programming mode can be
entered by unlocking, opening and closing of the frame within 45 seconds.
lWith programming code from rev. 4.
In programming mode
CODE 1
,
CODE 2
,
CODE 3
and
OPEN TIME
flashes under the
corresponding function buttons.
2. Enter A090 for normally closed (NC) relay function.
Enter A091 for normally open (NO) relay function.
3. Press the corresponding function button of the code to be changed, added or removed.
4. To erase the code, continue at step 6.
3 (5) ManualA04