Axis Power over Ethernet Midspan 8 port User manual

ENGLISH DEUTSCH ITALIANO ESPAÑOL
INSTALLATION GUIDE
FRAN
Ç
AIS
AXIS PoE MIDSPAN 8-Port
AXIS PoE Midspan 16-Port

About this Document
This manual includes instructions for using and
managing the AXIS PoE MIDSPAN 8-Port/ AXIS PoE
Midspan 16-Port on your network. Later versions of this
document will be posted to the Axis Website.
Intellectual Property Rights
Axis AB has intellectual property rights relating to
technology embodied in the product described in this
document. In particular, and without limitation, these
intellectual property rights may include one or more of
the patents listed at http://www.axis.com/patent.htm
and one or more additional patents or pending patent
applications in the US and other countries.
Electromagnetic Compatibility (EMC)
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to
radio or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
Re-orient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment to an outlet on a different
circuit to the receiver.
Consult your dealer or an experienced radio/TV
technician for help.
Shielded (STP) network cables must be used with this
unit to ensure compliance with EMC standards.
USA - This equipment has been tested and found to
comply with the limits for a Class B computing device
pursuant to Subpart B of Part 15 of FCC rules, which are
designed to provide reasonable protection against such
interference when operated in a commercial
environment. Operation of this equipment in a
residential area is likely to cause interference, in which
case the user at his/her own expense will be required to
take measures required to correct the interference.
Canada - This Class B digital apparatus complies with
Canadian ICES-003.
Europe - This digital equipment fulfills the
requirements for radiated emission according to limit B
of EN55022/1998, and the requirements for immunity
according to EN55024/1998 residential, commercial,
and light industry.
Japan - This is a class B product based on the standard
of the Voluntary Control Council for Interference from
Information Technology Equipment (VCCI). If this is used
near a radio or television receiver in a domestic
environment, it may cause radio interference. Install and
use the equipment according to the instruction manual.
Australia - This electronic device meets the
requirements of the Radio communications
(Electromagnetic Compatibility) Standard AS/NZS
CISPR22:2002.
Equipment Modifications
This equipment must be installed and used in strict
accordance with the instructions given in the user
documentation. This equipment contains no
user-serviceable components. Unauthorized equipment
changes or modifications will invalidate all applicable
regulatory certifications and approvals.
Every care has been taken in the preparation of this
manual. Please inform your local Axis office of any
inaccuracy or omission. Axis Communications AB cannot
be held responsible for any technical or typographical
errors and reserves the right to make changes to the
product and manuals without prior notice. Axis
Communications AB makes no warranty of any kind
with regard to the material contained within this
document, including, but not limited to, the implied
warranties of merchantability and fitness for a
particular purpose. Axis Communications AB shall not be
liable nor responsible for incidental or consequential
damages in connection with the furnishing,
performance or use of this material.
Support
Should you require any technical assistance, please
contact your Axis reseller. If your questions cannot be
answered immediately, the reseller will forward your
queries through the appropriate channels to ensure a
rapid response. If you are connected to the Internet, you
can:
• Download user documentation and firmware updates
• Find answers to resolved problems in the FAQ database
• Search by product, category, or phrases
• Report problems to Axis support by logging in to your
private support area
• Visit Axis Support at www.axis.com/techsup/
RoHS
This product complies with both the European
RoHS directive, 2002/95/EC, and the Chinese
RoHS regulations, ACPEIP.
WEEE Directive
The European Union has enacted a Directive
2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE Directive). This directive is
applicable in the European Union member
states.
The WEEE marking on this product or its documentation
indicates that the product must not be disposed of
together with household waste. To prevent possible
harm to human health and/or the environment, the
product must be disposed of in an approved and
environmentally safe recycling process. For further
information on how to dispose of this product correctly,
contact the product supplier, or the local authority
responsible for waste disposal in your area.
Business users should contact the product supplier for
information on how to dispose of this product correctly.
This product should not be mixed with other commercial
waste.
AXIS PoE MIDSPAN 8-Port/AXIS PoE Midspan 16-Port is
identical to the Phihong
PoE370U-480-8/PoE370U-480-16.

AXIS PoE Midspans 8P/16P Page 3
ENGLISH
Before you begin
Package Contents
• PoE Midspan
• Mains cable
• Two 19-inch rack mounting brackets
• Four M4 x 8mm Philips flat head screws
• AXIS warranty statement
• Four rubber feet
• Manual
Precautions
Please read the following carefully before installing and connecting the system to a power source.
• Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS 3260)
should install, replace, or service the equipment. Install the system in accordance with Country,
National, or the U.S. National Electric Code if you are in the United States.
• The building where this product is used requires a fuse or circuit breaker no larger than 15 A for
120 VAC (U.S.A.) or 10 A, 230 VAC (international). The building facility must protect the AXIS
PoE Midspans 8P/16P from over current or short-circuits.
• Read the Midspan Hardware Setup procedure before connecting the AXIS PoE Midspans 8P/16P
to a power source (including power cord requirements).
• Do not operate the product in an area that exceeds the maximum recommended ambient tem-
perature of 104 ºF/ 40 ºC to avoid overheating the AXIS PoE Midspans 8P/16P. Allow at least 3
to 4 inches/ 7.6 to 10.2 cm clearance around all ventilation openings.
• Do not stack the chassis on any other equipment to support its weight. Shelf mounted equip-
ment requires a stable and durable surface. Do not push or pull on the Midspan while installing.
• The AXIS PoE Midspans 8P/16P consist of two rows of "Data” and "Data & Power" ports. The
ports use RJ-45 data sockets. Connect only RJ-45 data cables to these sockets. Do not connect
telephone cables into these ports.
• Do not work on the AXIS PoE Midspans 8P/16P system or connect or disconnect cables, when
there is lightning.
• The AC or DC plug/socket combination must be accessible at all times, as it is the main discon-
nect device to the product.
• Before servicing the product, always disconnect the product from its AC source.
• Abide by appropriate national laws and regulations when it comes to discarding this product.

Page 4 AXIS PoE Midspans 8P/16P
Power Cord Requirements
Power cords must meet the requirements for the country they are used in.
• The Midspan must have access to a power outlet. Disconnect the power cord from the outlet, to
eliminate power from the device.
• The flexible cord that connects to the Midspan must have a configuration to connect with an
EN60320/IEC320 inlet connector.
• According to the EN60950/IEC 950 specifications, this device functions under SELV (Safety
Extra Low Voltage) conditions. The conditions are true if the equipment and the connected
device functions under SELV conditions.
• The AXIS PoE Midspans 8P/16P meet the UL/cUL per
EN60950 safety standard. This is displayed in the back side
of the product.
USA and Canada • The cord must have a minimum of 10A rated current competence.
• The cord must be CSA or UL approved.
• The minimum requirement for the flexible cord is:
• 18 AWG (10A)
• Three-conductor (line, neutral, ground)
• Type SV (Stranded Vacuum Rubber Jacketed) or SJ (Stranded Junior Rubber
Jacketed) or SVT (Stranded Vacuum Rubber Jacketed Themoplastic) or SJT
(Stranded Junior Themoplastic)
• The plug must be earth-grounded with a NEMA 5-15P (15A, 125 V) or
NEMA 6-15P (15A, 250 V) configuration.
Europe and South America Switzerland: The supply plug must comply with SEV/ASE 1011.
Denmark: The supply plug must comply with section 107-2-D1, standard DK2-1a
or DK2-5a.
United Kingdom: The Midspan is covered by General Approval (section 16.16.060),
NS/G/12345/J100003, for indirect connection to a public telecommunication
system
France and Peru: IT equipment cannot power this device. In the case of an IT
powered device, the unit needs to be powered by 230 V through an isolation
transformer with a ratio of 1:1 and the secondary connection (Neutral) is properly
grounded.

AXIS PoE Midspans 8P/16P Page 5
ENGLISH
Hardware Setup
Product overview
Front side of AXIS PoE 16 port & 8 port Midspan
AC Power connector at the back
Data Input Ports
The AXIS PoE Midspans 8P/16P have 10Base-T/100Base-TX data input ports, that have straight-
wired configuration. These ports carry Ethernet data (Tx/Rx) over the standard 2-wire pairs (pins 1/
2 and 3/6).
Data and Power Output Ports
The AXIS PoE Midspans 8P/16P Data and Power ports have straight-wire configuration. They are
designed to carry Ethernet data and DC power over the standard 2-wire pairs (pins 1/2 and 3/6; PoE
mode A).
Data
Data and Power
Data
Data and Power
Power connector

Page 6 AXIS PoE Midspans 8P/16P
Installation
Connecting Power Cables
The AC power cable is connected to the AC power connector located in the rear side of the AXIS PoE
Midspans 8P/16P and the power outlet.
Connecting Ethernet Cables
The ports in the product’s front panel are configured as ‘route through’ ports for all the eight/
sixteen RJ-45 connectors. Use Category 5 cabling in making connections.
1. Connect cables from the ethernet switch to the data ports - on the bottom row of the
AXIS PoE Midspans 8P/16P.
2. Connect the cables from the IEEE 802.3af powered devices to the corresponding Data
and Power ports on the top row of the AXIS PoE Midspans 8P/16P.
Powering Up
AXIS PoE Midspans 8P/16P are powered by the power cord. In order to apply or remove power to or
from the Midspan, connect or disconnect the AC power cable to or from the AC power connector on
the rear side of the unit.
With AC power the unit starts-up and the internal fans are active. The device runs through a quick
power-on test, which takes less than 10 seconds. During this period, all ports are initially disabled
and the port indicators light up. The sequence of the port LEDs are shown in the section below -
LED Indicator. Ports now operate under normal conditions.

AXIS PoE Midspans 8P/16P Page 7
ENGLISH
LED Indicators
Rack-Mounting Installation
Position the Midspan on the rack. Arrange the mounting bracket to the corresponding screw holes
in the Midspan. Keep the screw area visible to insert screws, and then tighten them.
Indicators
Conditions
Off Green Orange
static blinking static blinking
Power LED Midspan not
powered
Midspan
powered
n/a n/a n/a
Data & Power Port disabled Port
connected
Port
connected;
data port
disconnected
Port has an
error
Port is
disconnected,
but enabled

Page 8 AXIS PoE Midspans 8P/16P
Technical Specifications
Parameters Specifications
Data rate 10/100/1000 Mbps
Mounting Prepared for 19”, 1U rack installation
Installation and
management
Plug-and-play installation. Midspans automatically detect all Power Over
Ethernet enabled devices and supply inline power. Local LED management
display.
Port auto-sensing Standard IEEE 802.3af auto-sensing.
Display and indicators All port interfaces are located on the front panel for easy access and real-
time network monitoring. System: AC power, Channel indicator - power and
fault
Dimensions (HxWxD)
and weight
44.5 x 228 x 438 mm (1.75” x 8.98” x 17.26”) 4.08 kg (9 lbs)
Operating conditions 0 - 40 °C (32 - 104 °F): Humidity max 90% RH (non-condensing)
Connectors Shielded RJ–45, EIA 568A and 568B
Network cables Shielded category 5 (or higher) Ethernet; max. length up to 100 m (328 ft)
Wiring Mode A; data and power provided over pairs 1/2 (+) and 3/6 (-)
Input power • AC input voltage range: 90 - 264 V AC
• AC Input frequency: 47 - 63 Hz
• AC input current: 4.5 A (RMS) max. for 90 V AC, 2.25 A (RMS)
max. for 240 V AC
Output power 48 V DC (max 15.4 W/port)
Compliance IEEE 802.3 standard (when no inline power is supplied) and
IEEE 802.3af, DTE Power via Media Dependent Interface (MDI)
Approvals • TUV EN 60950
• FCC Class B, EN55022 Class B, EN61000-4-2. EN61000-4-3,
• EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11,
• EN61000-3-2 Class A
• Safety: cUL/UL, TUV, CE

AXIS PoE Midspans 8P/16P Page 9
ENGLISH
Troubleshooting
If problems occur with the Midspan, please refer to the table below. The troubleshooting solutions
provided can only solve minor problems. If your problem is not listed, please contact our local office
for further technical assistance.
Problem Possible Solutions
Midspan does not power up 1. Ensure that AC power cord is connected.
2. Ensure that AC power cord is in good condition.
3. If neither of the above is the problem, disconnect the
AC power cord and reconnect. Observe Port LEDs to verify
proper power up.
AC LED unlit Verify if the Midspan is properly connected to an AC
power source.
Data and Power Port LED do not light 'green' Ensure Ports are connected to a Network.
Verify the following:
1. Power is applied to the Midspan
2. Network Ethernet cable is connected to the Data port
3. Powered device Ethernet cable is connected to the Data
& Power port
4. The right kind of Ethernet cable is used; do not use
crossover-type Ethernet cable
5. Cable pairs are connected to corresponding ports.


Page 11
FRAN
Ç
AIS
Contenu de l'emballage
• Midspan PoE
•Câblesecteur
• Deux supports de montage en baie de 19 pouces
• Quatre vis à tête plate Philips M4 x 8 mm
• Déclaration de garantie AXIS
• 4 pieds en caoutchouc
• Manuel
Informations de sécurité
Veuillez lire attentivement les informations qui suivent avant d'installer et de connecter le système
à une source d'alimentation.
Remarque:
Seul le personnel de maintenance qualifié et formé (conformément aux normes IEC
60950 et AS/NZS 3260) est autorisé à installer, remplacer ou dépanner le matériel.
Installez le système conformément aux procédures en vigueur dans votre pays, ou au
U.S. National Electric Code si vous êtes aux États-Unis.
• Le bâtiment dans lequel ce produit doit être utilisé doit être muni d'un fusible ou d'un disjonc-
teur n'excédant pas 15 A pour 120 Vca (États-Unis) ou 10 A pour 230 Vca (international).
L'installation du bâtiment doit protéger le midspan AXIS PoE 8P/16P des surtensions et des
courts-circuits.
• Consultez la procédure d'installation du matériel avant de connecter le midspan AXIS PoE 8P/
16P à une source d'alimentation (notamment les conditions relatives au câble d'alimentation).
• N'utilisez pas le produit dans un local dépassant la température ambiante maximale recom-
mandée de 40 °C/104 °F, afin d'éviter la surchauffe du midspan AXIS PoE 8P/16P. Prévoyez un
dégagement d'au moins 7,6 à 10,2 cm (3 à 4 pouces) au niveau de tous les évents.
• N'empilez pas le châssis sur d'autres appareils afin d'en soutenir le poids. L'équipement monté
sur étagère nécessite une surface stable et résistante. Ne poussez pas ou ne tirez pas sur le mid-
span pendant que vous l'installez.
• Le midspan AXIS PoE 8P/16P comporte deux rangées de ports « Données » et « Données & Ali-
mentation ». Ces ports utilisent des connecteurs de données RJ-45. Ne connectez pas de câbles
téléphoniques à ces ports. Connectez-y uniquement des câbles de données RJ-45.
• Ne travaillez pas sur le système midspan AXIS PoE 8P/16P et ne connectez ou ne déconnectez
aucun câble en cas d'orage.
• La combinaison fiche/prise CA ou CC doit être accessible à tout moment, car elle constitue le
principal dispositif de déconnexion du produit.
• Avant toute intervention sur le produit, débranchez-le toujours de sa source de CA.
• Adhérez à la réglementation nationale appropriée pour la mise au rebut du produit.

Page 12
Conditions requises pour les câbles d'alimentation
Les câbles d'alimentation doivent être conformes aux conditions requises par le pays dans lequel ils
sont utilisés.
• Le midspan doit avoir accès à une prise de courant. Débranchez le câble d'alimentation de la
prise pour couper l'alimentation de l'appareil.
• Le câble flexible qui se connecte au midspan doit présenter une configuration appropriée à un
branchement sur un connecteur d'entrée EN60320/IEC320.
• Selon les spécifications de la norme EN60950/IEC 950, cet appareil fonctionne dans des condi-
tions SELV (Safety Extra Low Voltage). Ces conditions sont remplies si l'équipement et l'appareil
connecté fonctionnent dans des conditions SELV.
• Le midspan AXIS PoE 8P/16P est conforme UL/cUL selon la
norme de sécurité EN60950. Ces informations apparaissent à
l'arrière du produit.
États-Unis et
Canada
• Le câble doit supporter au minimum une intensité nominale de 10 A.
• Le câble doit être agréé CSA ou UL.
• Les conditions minimales suivantes sont requises pour le câble flexible :
• 18 AWG (10 A)
• Trois conducteurs (phase, neutre, terre)
• Type SV (Stranded Vacuum Rubber Jacketed), SJ (Stranded Junior Rubber Jack-
eted), SVT (Stranded Vacuum Rubber Jacketed Themoplastic) ou SJT (Stranded
Junior Themoplastic)
• "La prise doit être mise à la terre avec une configuration NEMA 5-15P (15 A,
125 V) ou NEMA 6-15P (15 A, 250 V).
Europe et Amérique
du Sud
Suisse : la prise d'alimentation doit être conforme à la norme SEV/ASE 1011.
Danemark : la prise d'alimentation doit être conforme à la section 107-2-D1 de la
norme DK2-1a ou DK2-5a.
Royaume-Uni : La réglementation relative au midspan est traitée dans le General
Approval (section 16.16.060) NS/G/12345/J100003 sur les connexions indirectes à un
système de télécommunications publiques.
France et Pérou : Aucun matériel informatique ne peut alimenter cet appareil. Dans le
cas d'un appareil alimenté par un système informatique, l'unité doit être alimentée à
230 V par l'intermédiaire d'un transformateur de séparation présentant un rapport de
1:1 et la connexion secondaire (Neutre) doit bénéficier d'une mise à la terre correcte.

Installation du matériel Page 13
FRAN
Ç
AIS
Installation du matériel
Aspect
Ports d'entrée de données
Le midspan AXIS PoE 8P/16P comporte des ports d'entrée de données 10Base-T/100Base-TX à
raccordement direct. Ces ports acheminent des données Ethernet (transmission/réception) sur les
paires 2 fils standard (broches 1/2 et 3/6).
Ports de sortie données et alimentation
Les ports de données et d'alimentation du midspan AXIS PoE 8P/16P présentent une configuration à
raccordement direct. Ils sont conçus pour acheminer des données Ethernet et du courant continu
sur les paires 2 fils standard (broches 1/2 et 3/6 ; PoE mode A).
Face avant du midspan
AXIS PoE 16P
Données
Données et alimentation
Données
Données et alimentation
Connecteur d'alimentation CA à l'arrière

Page 14 Installation
Installation
Connexion des câbles d'alimentation
Le câble d'alimentation CA se branche sur le connecteur d'alimentation CA situé sur la face arrière
du midspan AXIS PoE 8P/16P et sur la prise de courant.
Connexion des câbles Ethernet
Les ports présents sur le panneau avant du produit sont configurés en tant que ports
d'acheminement pour l'ensemble des huit/seize connecteurs RJ-45. Utilisez des câbles de catégorie
5 pour établir les connexions.
1. Connectez les câbles entre le commutateur Ethernet et les ports de données, dans la
rangée inférieure du midspan AXIS PoE 8P/16P.
2. Connectez les câbles entre les appareils IEEE 802.3af et les ports de données et
d'alimentation correspondants, dans la rangée supérieure du midspan AXIS PoE 8P/16P.
Mise sous tension
Le midspan AXIS PoE 8P/16P est alimenté par le câble secteur. Pour mettre le midspan sous tension
ou hors tension, branchez le câble d'alimentation CA sur le connecteur CA situé à l'arrière de l'unité
ou débranchez-le.
Dès qu'elle est alimentée en CA, l'unité démarre et les ventilateurs internes s'activent. L'appareil
procède à un bref test à la mise sous tension, qui dure moins de dix secondes. Pendant cette
période, les ports sont désactivés et leurs témoins lumineux s'allument. La séquence des témoins
DEL des ports est fournie dans la section ci-dessous - Témoin DEL. Les ports fonctionnent ensuite
dans des conditions normales.

Installation Page 15
FRAN
Ç
AIS
Témoin DEL
Installation en baie
Placez le midspan sur la baie. Alignez le support de montage sur les trous de vis correspondants du
midspan. Laissez les zones de vissage visibles pour insérer les vis, puis serrez-les.
Témoins
Conditions
Désactivé Vert Orange
statique clignotant statique clignotant
Témoin DEL
d'alimentation
Midspan
hors
tension
Midspan
sous tension
Ne s'applique
pas
Ne
s'applique
pas
Ne s'applique pas
Données et
alimentation
Port
désactivé
Port
connecté
Port connecté
; port de
données
déconnecté
Erreur sur
le port
Port déconnecté, mais
activé

Page 16 Caractéristiques techniques
Caractéristiques techniques
Paramètres Spécifications
Spécifications mécaniques
Dimensions Longueur 438 mm (17,25 pouces)
Largeur 228 mm (8,98 pouces)
Hauteur 44,5 mm (1,75 pouce)
Poids 4,08 kg (9 livres)
Spécifications d'environnement
Température Sous tension : de 0 à 40 °C (de 32 à 104 °F)
Hors tension : de -25 à +65 °C (de -77 à 149 °F)
Humidité relative Sous tension : de 5 à 90 %
Hors tension : de 5 à 90 %
Dissipation maximale de chaleur du
midspan AXIS PoE 8P/16P
Mode CA =125 W
Spécifications électriques
Tension nominale alternative d'entrée De 100 à 240 Vca
Gamme des tensions alternatives
d'entrée
De 90 à 264 Vca
Courant alternatif d'entrée Intensité max. 5,5 A (rms)
Fréquence alternative d'entrée De 47 à 63 Hz
Courant d'appel max. 30 A pour 115 Vca à intensité max.
60 A pour 230 Vca à intensité max.
Tension alternative de sortie 480: 50 Vcc
56 Vcc : 56 Vcc
Intensité maximale 480: 0,32 A
56 Vcc : 0,275 A
Puissance de sortie, par port 15,4 W (ne doit pas excéder la puissance de sortie
maximale)
Alimentation de sortie totale Nbre de ports : 8 - 125 W max, 16 - 250 W max
Tension nominale de sortie De 44 à 57 Vcc
Homologations •cUL/UL
•TUV
•CE

Dépannage Page 17
FRAN
Ç
AIS
Dépannage
Si des problèmes surviennent au niveau du midspan, consultez le tableau ci-dessous. Les solutions
de dépannage fournies ne peuvent s'appliquer qu'aux problèmes mineurs. Si le problème que vous
rencontrez ne figure pas dans la liste, contactez notre représentant local pour bénéficier d'une
assistance technique.
Problème Solutions possibles
Le midspan ne s'allume pas. 1. Assurez-vous que le câble d'alimentation CA est
branché.
2. Assurez-vous que le câble d'alimentation CA est
en bon état.
3. Si le problème ne correspond à aucun des deux
cas précédents, débranchez le câble d'alimentation
CA et rebranchez-le. Observez les témoins DEL des
ports pour vérifier leur mise sous tension.
Témoin DEL de CA éteint Assurez-vous que le midspan est bien branché sur
une source d'alimentation CA.
Le témoin DEL du port Données et alimentation
n'est pas allumé en vert
Assurez-vous que les ports sont connectés à un
réseau.
Vérifiez les points suivants :
1. Le midspan est sous tension.
2. Le câble réseau Ethernet est connecté au port de
données.
3. Le câble Ethernet de l'appareil sous tension est
connecté au port Données et alimentation.
4. Le type correct de câble Ethernet est utilisé ;
n'employez pas de câbles Ethernet de type
inverseur.
5. Les paires de câbles sont connectées aux ports
correspondants.


Seite 19
DEUTSCH
Lieferumfang
• PoE Midspan
• Stromversorgungskabel
• Zwei Befestigungsklammern für 19-Zoll-Racks
• Vier M4 x 8 mm Kreuzschlitz-Flachkopfschrauben
• AXIS-Garantieerklärung
• 4 Gummifüße, Handbuch
Sicherheitsinformation
Lesen Sie die folgenden Anweisungen vor Installation des Systems und Anschluss desselben an eine
Stromquelle sorgfältig durch.
Hinweis:
Nur qualifiziertes und geschultes Personal darf die Installation, den Austausch oder die
Wartung der Ausrüstung durchführen (in Übereinstimmung mit IEC 60950 und AS/NZS
3260). In den USA: Installieren Sie das System gemäß den Vorschriften des Country,
National oder des U.S. National Electric Code.
• Das Gebäude, in dem dieses Gerät verwendet werden soll, muss mit einer Sicherung nicht höher
als 15 A bei 120 VAC (U.S.A.) oder 10 A bei 230 VAC (international) geschützt sein. Die
Gebäudeanlage muss den AXIS PoE Midspans 8P/16P vor Überspannung oder Kurzschlüssen
schützen.
• Lesen Sie die Informationen zum Hardware-Setup des Midspan (einschließlich der Anforderun-
gen an das Stromkabel), bevor Sie den AXIS PoE Midspans 8P/16P an eine Stromquelle
anschließen.
• Installieren Sie das Gerät nicht an einem Ort, an dem die Umgebungstemperatur die maximal
empfohlene Betriebstemperatur von 40 ºC (104 ºF) überschreitet, um eine Überhitzung des AXIS
PoE Midspans 8P/16P zu vermeiden. Um die Lüftungsschlitze muss mindestens ein Abstand von
7,6-10,2 cm (3-4 Zoll) eingehalten werden.
• Stapeln Sie das Gehäuse nicht auf anderer Ausrüstung, um dessen Gewicht zu stützen. Bei Aus-
rüstung, die in Regalen installiert wird, muss auf eine ebene und stabile Grundfläche geachtet
werden. Den Midspan nicht beim Installationsvorgang drücken oder ziehen.
• Der AXIS PoE Midspans 8P/16P verfügt über zwei Anschlussreihen für reine Daten- sowie für
Daten- und Stromanschlüsse. Die Anschlüsse sind RJ-45-Datenanschlüsse. Verbinden Sie keine
Telefonkabel mit diesen Anschlüssen. Verwenden Sie für diese Anschlüsse ausschließlich RJ-45-
Datenkabel.
• Führen Sie bei Blitzschlag keine Arbeiten am AXIS PoE Midspans 8P/16P-System durch oder
nehmen Sie keine Modifikationen der Kabelverbindungen am System vor.

Seite 20
• Der AC/DC-Anschluss muss jederzeit zugänglich sein, da dies die Hauptanschlussstelle des
Geräts ist.
• Vor Wartungsarbeiten am Produkt muss dieses stets von der Wechselstromquelle getrennt wer-
den.
• Befolgen Sie nationale Gesetze und Richtlinien, wenn Sie das Gerät entsorgen müssen.
This manual suits for next models
2
Table of contents
Languages:
Other Axis Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

Puretec
Puretec Radfire RI-HF34 user guide

Healthmark
Healthmark MAG-225 Instructions for use

3D Histech
3D Histech Pannoramic DESK user guide

3D Histech
3D Histech Pannoramic SCAN 150 user guide

Cooper Surgical
Cooper Surgical RI Witness 6-70-854 quick start guide

Isotech
Isotech LIBRA 785 User maintenance manual/handbook

Bio-Tek
Bio-Tek 405 TS Getting started guide

Planet
Planet IPOE-162 user manual

Novatech Instruments
Novatech Instruments 2960AR instruction manual

PerkinElmer
PerkinElmer OPTIMA 8000 Customer Hardware and Service Guide

J.P. SELECTA
J.P. SELECTA PRECISDIG 6001195 manual

Amsco
Amsco Evolution Series Operator's manual