Axis 25735 Instruction sheet

Before attempting to connect or operate this product,
please read these instructions completely.
Product
Instructions
25733 & 25735
81-IN6210
03/28/07
COMMUNICATIONS

- 2 -
!
!
SAFETY PRECAUTIONSIMPORTANT SAFEGUARDS
1. Read Instructions - All the safety and operating instructions
should be read before the unit is operated.
2. Retain Instructions - The safety and operating instructions
should be retained for future reference.
3. Heed Warnings - All warnings on the unit and in the operating
instructions should be adhered to.
4. Follow Instructions - All operating and user instructions should
be followed.
5. Electrical Connections - Only a qualied electrician should make
electrical connections.
6. Attachments - Do not use attachments not recommended by
the product manufacturer as they may cause hazards.
7. Cable Runs - All cable runs must be within permissible
distance.
8. Mounting - This unit must be properly and securely mounted to
a supporting structure capable of sustaining the weight of the
unit. Accordingly:
a. The installation should be made by a qualied installer.
b. The installation should be in compliance with local codes.
c. Care should be exercised to select suitable hardware to
install the unit, taking into account both the composition of
the mounting surface and the weight of the unit. Be sure to
periodically examine the unit and the supporting structure to
make sure that the integrity of the installation is intact. Failure
to comply with the foregoing could result in the unit separating
from the support structure and falling, with resultant damages
or injury to anyone or anything struck by the falling unit.
WARRANTY INFORMATION
Videolarm, Incorporated warrants that products sold hereunder
shall be t for the ordinary purpose for which said products
are intended and shall be free from defects in material and
workmanship for a period of two years from date of sale to
buyer. Videolarm makes no other warranty of any kind with
respect to this product, whether expressed or implied, including,
without limitation, the implied warranty of tness for a particular
purpose.
In the event of a breach of the above warranty, Videolarm shall,
at its option, repair or replace said product. This is Videolarm's
sole obligation under this warranty. In no event shall Videolarm
be liable for any incidental or consequential damages, as dened
in section 2-715 of the Uniform Commercial Code by a breach
of this warranty.
Videolarm shall repair or replace defective products upon shipment
of products prepaid to Videolarm, Inc., 2525 Park Central Blvd.,
Decatur, GA 30035.
Repairs made necessary by reason of accident, misuse or normal
wear shall be charged at Videolarm's standard rate. This warranty
gives you specic legal rights, and you may also have other rights
which vary from state to state.
UNPACKING
Unpack carefully. Electronic components can be damaged if
improperly handled or dropped. If an item appears to have been
damaged in shipment, replace it properly in its carton and notify
the shipper.
Be sure to save:
1. The shipping carton and packaging material. They are the safest
material in which to make future shipments of the equipment.
2. These Installation and Operating Instructions.
SERVICE
If the unit ever needs repair service, the customer should contact
Videolarm (1-800-554-1124) for authorization to return and shipping
instructions.
TECHNICAL SUPPORT
If technical support is needed, Videolarm has set-up a 24 hour
technical support line for their customers.
1-800-554-1124
CAUTION: TO REDUCE THE RISK OF
ELECTRICAL SHOCK, DO NOT EXPOSE
COMPONENTS TO WATER OR MOISTURE.
The lightning ash with an arrowhead symbol,
within an equilateral triangle, is intended to alert the
user to the presence of non-insulated "dangerous
voltage" within the product's enclosure that may
be of sufcient magnitude to constitute a risk of
electric shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.
24 HOUR TECHNICAL SUPPORT
CAUTION
RISK OF
ELECTRIC SHOCK!

- 3 -
!
ELECTRICAL SPECIFICATIONS (OUTDOOR ONLY):
NOTE: This unit is designed for operation in an
upright position. Installing the unit upside
down may cause damage to the internal
equipment, and will void the warranty.
GENERAL INSTRUCTIONS:
Tools Required: .100" Flat Head Screwdriver
Phillips Head Screwdriver
Power 24VAC, Class 2 Only
26 watts at 24 VAC (accessories)
Heater: 25 watts
Blower: 1 watt
Teon Tape
ASSEMBLING THE PRODUCT:
1. Remove the contents of the box onto a table. The larger
subassembly box is the housing assembly. The smaller
subassembly box is the dome assembly. (Picture 1)
2. Open the housing assembly box. Note there is a small roll
of Teon Tape that will be needed during installation, put it
aside. (Picture 2)
Picture 1
3, Open the dome assembly box. Note there is a protection
lm on the dome. DO NOT REMOVE the lm until the
product is fully assembled and installed. This lm protects
the dome from scratches during installation. (Picture 3)
4. There is a safety lanyard that is attached to the inside of
the dome assembly. Take the open end of the lanyard
and loop it around the lanyard tab that is located inside
the housing top. (Picture 4)
5. The safety lanyard is now attached to the housing.
Picture 4
Picture 3
Picture 2

- 4 -
2. In the kit there are (8) aluminum spacers - (4) 1" and (4) ½".
Thread (2) spacers - (1) 1" and (1) ½" - on top of each of the (4)
2" spacers that are already located on the base bracket inside
the housing.
3. Then start (3) 8-32x3/8” phillips head screws onto the 3½ inch
spacers inside the housing. Be sure to place the screws so that
they line up with the (3) open slots on the quick release bracket.
4. The camera assembly in the housing, sliding the (3) open
screw slots over the screws in the housing. Slide the bracket
forward, and the tighten the captive screw on the bracket
½" + 1"
spacers
Captive Screw
(3) screws
in housing
Installing Axis 213 Camera
1. Install the camera onto the quick release bracket using (2)
10-32 x 3/8” screws and star washers provided in the packet.
Attach cameras using these inserts
½"
2"
1"

- 5 -
Connect the power plug and the ethernet cable to the back of the
camera.
CAMERA POWER
+12 VDC -12 VDC
For Model 21893 only
If alarm connections are needed use the chart below for reference.
Power Connection - Reference Only
CONTROL
RJ45 Ethernet Connector
ALARMS
1 Alarm 1 Blue
2 Alarm 2 Violet
3 Alarm 3 Gray
4 Common White
Installing Axis 213 Camera (cont.)

- 6 -
Installing Axis 214 Camera
2685 Mounting Plate:
Attach camera using these (3) holes
1. Install the AXIS 214 camera to the 2685 mounting
plate using the (3) 3mm x 12mm bolt and lock washers
provided.
2. The AXIS 214 camera requires 2” of spacing for optimal
position within the housing. Use the 8 (1”) spacers
provided in the packet.
3. Place (3) 8 x 32 x s Phillips head screws on the top
of the spacer as shown above. Be sure to place the
screws so that they line up with the open slots on the
mounting plate.
4. Slide the mounting plate with camera into position on
top of spacers. Secure 3 screws and captive fastener.
2"

- 7 -
Installing Axis 231D/232D Camera
1. Install the camera onto the quick release bracket. Loosen one of
the screws on the bottom of the camera, see diagram below.
2. Place quick release bracket onto the bottom of the camera,
making sure that the (3) locking buttons
line up with the keyhole slots
in the Q/R bracket.
Also make sure
the screw that
you loosened
up in the
previous
step lines
up with
the slot
located
next
to the
captive
insert.
3. Turn the camera counter
clockwise.
4. When the locking buttons hit the end of the keyhole slots.
Tighten the locking screw. Then put the camera assembly aside.
6. Now attach (4) ½” spacers (located in the packet that came with
the housing) to the base bracket.
5. Remove the (4) ½” spacers that are attached to the base bracket
inside the housing.
Locking screw
½" spacers
Base Bracket
½" spacers
Base Bracket
Loosen screw
Locking buttons
Locking screw
Captive insert
Keyhole slots
½"

- 8 -
Installing Axis 231D/232D Camera
(cont.)
7. Then start (3) 8-32x3/8” plillips head screws onto the 3 inch
spacers inside the housing. Be sure to place the screws so that
they line up with the (3) open slots on the quick release bracket,
the screws on the bottom of the camera, see diagram below.
8. Since the 231D/232D camera operates on 24vac, the power
board that is located inside the housing is not needed. The
remove the power board, start by loosening the screws on the
terminal block and disconnect the orange and red wires.
9. With a Phillips head screwdriver remove the (4) machine screws
holding the power board to the base bracket.
10. Locate the connector
block, which is
included with the
camera. Then
located the connector
block bracket, which
is included with the
housing. Attach the
block to the bracket
as shown in the
following diagram.
Use the M3 screws
and washers that are
located in the housing
packet.
11. Attach the connector
block assembly to
the housing using (1)
6-32x3/8” screw and
star washer located in
the housing packet.
(3) 8-32 x 3/8"screws
Machine screws (4)
Base Bracket

- 9 -
12. Make wiring connections to connector block assembly per
camera instructions.
Installing Axis 231D/232D Camera
(cont.)
13. To manage the input cable running from the connector block to
the camera use the (2) cable tie mounts and cable ties that are
located in the housing packet.
For Model 25733 only
CONTROL
RJ45 Ethernet Connector
ALARMS
1 Alarm 1 Blue
2 Alarm 2 Violet
3 Alarm 3 Gray
4 Common White
POWER
1 Camera Power (24VAC) Red
2 Camera Power (24VAC) Orange
Cable Tie Mounts
Cable Ties

- 10 -
14. Now grab the camera assembly and connector the RJ45 cable
and the input cable to the camera.
15. Now attached the camera assembly to the housing by sliding the
(3) open screw slots over the screws in the housing. Slide the
bracket forward, and the tighten the captive screw on the bracket.
Open screw slots
(REFERENCE ONLY)
Installing Axis 231D/232D Camera
(cont.)
Captive screw

- 11 -
Installing Axis 233 Camera
1. Note the position of the mounting holes on the camera
bracket (see diagram below).
5. Turn the camera counter clockwise.
6. When the locking
buttons hit the end
of the keyhole
slots, tighten
the locking
screw.
2. Now attach (4) ½” spacers
(located in the packet
that came with
the housing)
to the base
bracket.
3. Mount the
camera
bracket to
the Axis 233
camera
Q/R plate
(Quick
Release
plate) as
shown.
Keyhole Slots
4. Place the Quick Release plate onto the bottom of the
camera,
Make sure that the
locking screws
on the AXIS 233
camera line up
with the keyhole
slots on the Q/R
plate.
Slide the
camera into
the keyhole
slots by
targeting
the locking
screw(s).
Quick Release
(Q/R) plate
Keyhole Slots Locking Screw
Keyhole Slots
Mounting holes
Mounting holes
½"

- 12 -
The unit is setup with (2) individual power inputs.
1. Accessory Power (yellow and green wire)
2. Camera Power (red and orange)
If you wish to provide a single power transformer it is recommended that:
1. Be certain that you know the total power consumption of the
housing Heaters (25 watts) + Blowers (2 watts) + camera/pan-tilt
(not supplied)
2. Check the supplied wiring chart to be sure that you have the
proper gauge wire for the distance that you intend to run your
power wires.
3. Bring power to the 3 and 4 position of the power connector (yellow
and green wire)
4. Two jumpers are provided in the housing packet. Jumper from
the 1st position to the 3rd position and from the 2nd position to the
4th position of the terminal block. Be careful not to short between
the yellow and green wires.
Add 2 jumpers
for single
power input
One Power Supply for both Camera and Accessory Power
52 watts (VA), 24 VAC, Class 2 Only
NOTE: In this combination, run power to the camera connector, then
run jumper wires (not provided) to the accessory side of the
connector.
22
90
20 18
130
16
225
14
350
12
525
10
830
Maximum distance from transformer to housing
Total vA consumed
Wire Gauge
24 VAC Wiring Distances
The following are the recommended maximum distances for 24VAC with a
10% voltage drop. (10% is generally the maximum allowable voltage drop
for AC-powered devices.)
6530
56 90 143 228 362 576
3550
POWER WIRING
Two plug-in wall transformers are included with the housing. Use
one to provide power for the heater and blower in the housing,
and the other for the camera. Determine where the transform-
ers will be located, then run two sets of power wires into the wall
mount bracket (Four total power wires). Use the chart below to
determine the correct gauge of wire needed based on the length
of the run and the 30vA power line.
CONNECTING THE TRANSFORMERS
Determine which transformer will be attached to the camera. Attach
the red and orange wires to the terminal points on the transformer
For the transformer which will be used for the heater and blower, at-
tach the yellow and green wires to the terminal points.
NOTE: You may attach wires to either terminal, however MAKE
SURE THAT THE TRANSFORMERS ARE ATTACHED TO THE
PROPER CONNECTION ON THE HOUSING.
Green
Yellow
Orange
Red
Camera
Power
Accessory
Power
Camera
Power
Accessory
Power
213 = 24 watts @ 13Vdc
214 = 14 watts @ 12Vdc
231D/232D = 25 watts @ 24Vdc
Chart A Wiring Color Code
Power and Control Inputs (Outside of housing)
For Model 25735
See camera instructions for wiring connections
CONTROL
RJ45 Ethernet Connector
Separate Power Supplies for Camera and Accessory Power
Camera: 25 watts (VA), 24 VAC, Class 2 Only
Accessory: 27 wattts (VA), 24 VAC, Class 2 Only
POWER
1 Camera Power (24 VAC) Red
2 Camera Power (24 VAC) Orange
3 Accessory Power (24 VAC) Yellow
4 Accessory Power (24 VAC) Green
ALARMS
1 Alarm 1 Blue
2 Alarm 2 Violet
3 Alarm 3 Gray
4 Common White

- 13 -
Set screws
Figure 4
INSTALLING THE HOUSING ASSEMBLY:
1. This unit includes a 1½" NPT housing for a standard 1½"
NPT pipe. The housing can be used with other brackets
designed with 1½" male pipe threads, such as the 25736
wall mount brackets.
2. Attach the housing coupling (Figure 3).
NOTE: Pipe threads should be clean and rust free.
Use the Teon™tape included with
the housing on the threads.
Figure 3
Add thread
sealing tape
NOTE: This unit is designed for operation in an
upright position. Installing the product upside
down may cause damage to the internal
equipment, and will void the warranty.
Be sure the bracket is properly and securely
mounted to a supporting structure capable of rigidly
holding the weight of the entire unit.
!
3. Mount the housing assembly to the mounting bracket
and housing coupling. A safety cable is included with
the housing to temporarily hold it while making wiring
connections. Loop the safety cable over one of the set
screws on the housing coupling and make the appropriate
connections using the (2) screw-down connectors supplied.
2. Undo the safety cable and twist the housing onto the
housing coupling. Secure all (3) setscrews provided on the
housing coupling (Figure 4).
REMOVING AND ATTACHING THE DOME ASSEMBLY:
1. Attach the dome assembly to the housing top by lining up
the arrow on the dome assembly with the left arrow on the
housing top. Insert the dome assembly into the housing and
then rotate the dome assembly clockwise until the dome
assembly’s arrow lines up with the arrow that has the word
locked above it. Then tighten the (3) screws on the front of
the dome assembly.
2. Remove the protective lm from the dome.
3. Clean the outside of the dome.

- 14 -
2
1
3
5
46
7
9
8
Exploded View for Replacement Parts
14
15

- 15 -
Part Number Description
1RPFD7501 LOWER TRIM RING (Long)
225740 TINTED REPLACEMENT CAPSULE
25741 CLEAR REPLACEMENT CAPSULE
3 RPFD703 DOME CLAMPING BRACKET
4 RPFD072 24 VAC HEATER
5 RPFD080 BLOWER
6 RPFD060 CAMERA BRACKET
7 RPRH707 CONNECTION PCB
8 RPFD040 HOUSING HARDWARE
9 RPFD709 HOUSING TOP
14 SD0160 PENDANT COUPLING KIT
15 SD0170 QUICK RELEASE PIPE COUPLING
N/S RPNET02 24 TO 12VDC POWER BOARD
Replacement Parts List
This manual suits for next models
1
Table of contents
Other Axis Security Camera manuals

Axis
Axis AXIS 2420 W/Lens User manual

Axis
Axis Q86 Series User manual

Axis
Axis M30 Series User manual

Axis
Axis M50 Series User manual

Axis
Axis Q6124-E User manual

Axis
Axis 01991-001 User manual

Axis
Axis Q35 Series User manual

Axis
Axis AXIS 223M User manual

Axis
Axis AXIS M20 Series User manual

Axis
Axis P5522 User manual