Axis D8004 User manual

AXISD8004UnmanagedPoESwitch
InstallationGuide

Readthisrst
ReadthroughthisInstallationGuidecarefullybefore
installingtheproduct.KeeptheInstallationGuidefor
futurereference.
Legalconsiderations
Videoandaudiosurveillancecanberegulatedbylaws
thatvaryfromcountrytocountry.Checkthelaws
inyourlocalregionbeforeusingthisproductfor
surveillancepurposes.
Liability
Everycarehasbeentakeninthepreparationofthis
document.Pleaseinformyourlocalxisofceof
anyinaccuraciesoromissions.xisCommunications
Bcannotbeheldresponsibleforanytechnicalor
typographicalerrorsandreservestherighttomake
changestotheproductandmanualswithoutprior
notice.xisCommunicationsBmakesnowarranty
ofanykindwithregardtothematerialcontained
withinthisdocument,including,butnotlimitedto,
theimpliedwarrantiesofmerchantabilityandtness
foraparticularpurpose.xisCommunicationsB
shallnotbeliablenorresponsibleforincidental
orconsequentialdamagesinconnectionwiththe
furnishing,performanceoruseofthismaterial.This
productisonlytobeusedforitsintendedpurpose.
Intellectalpropertyrights
xisBhasintellectualpropertyrightsrelatingto
technologyembodiedintheproductdescribedinthis
document.Inparticular,andwithoutlimitation,these
intellectualpropertyrightsmayincludeoneormoreof
thepatentslistedataxis.com/patentandoneormore
additionalpatentsorpendingpatentapplicationsin
theUSandothercountries.
Eqipmentmodications
Thisequipmentmustbeinstalledandusedin
strictaccordancewiththeinstructionsgivenin
theuserdocumentation.Thisequipmentcontains
nouser-serviceablecomponents.Unauthorized
equipmentchangesormodicationswillinvalidateall
applicableregulatorycerticationsandapprovals.
Trademarkacknowledgements
XISCOMMUNICTIONS,XISandVPIXare
registeredtrademarksortrademarkapplicationsof
xisBinvariousjurisdictions.llothercompany
namesandproductsaretrademarksorregistered
trademarksoftheirrespectivecompanies.
Reglatoryinformation
Europe
ThisproductcomplieswiththeapplicableCEmarking
directivesandharmonizedstandards:
•ElectromagneticCompatibility(EMC)Directive
2014/30/EU.SeeElectromagneticcompatibility
(EMC)onpage2.
•LowVoltageDirective(LVD)2014/35/EU.See
Safetyonpage3.
•RestrictionofHazardousSubstances(RoHS)
Directive2011/65/EUand2015/863,including
anyamendments,updatesorreplacements.See
Disposalandrecyclingonpage3.
copyoftheoriginaldeclarationofconformity
maybeobtainedfromxisCommunicationsB.See
Contactinformationonpage3.
Electromagneticcompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulll
applicablestandardsfor:
•Radiofrequencyemissionwheninstalled
accordingtotheinstructionsandusedinits
intendedenvironment.
•Immunitytoelectricalandelectromagnetic
phenomenawheninstalledaccordingtothe
instructionsandusedinitsintendedenvironment.
USA
Thisdevicecomplieswithpart15oftheFCCRules.
Operationissubjecttothefollowingtwoconditions:
1.Thisdevicemaynotcauseharmfulinterference,
and
2.thisdevicemustacceptanyinterferencereceived,
includinginterferencethatmaycauseundesired
operation.
Thisequipmenthasbeentestedusingashielded
networkcable(STP)andfoundtocomplywiththe
limitsforaClassBdigitaldevice,pursuanttopart15
oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterferencein
aresidentialinstallation.Thisequipmentgenerates,
usesandcanradiateradiofrequencyenergyand,
ifnotinstalledandusedinaccordancewiththe
instructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.
Ifthisequipmentdoescauseharmfulinterferenceto
radioortelevisionreception,whichcanbedetermined
byturningtheequipmentoffandon,theuseris
encouragedtotrytocorrecttheinterferencebyone
ormoreofthefollowingmeasures:
•Reorientorrelocatethereceivingantenna.
•Increasetheseparationbetweentheequipment
andreceiver.
•Connecttheequipmentintoanoutletona
circuitdifferentfromthattowhichthereceiver
isconnected.
•Consultthedealeroranexperiencedradio/TV
technicianforhelp.
Theproductshallbeconnectedusingashielded
networkcable(STP)thatisproperlygrounded.
Contactinformation
xisCommunicationsInc.
300polloDrive
Chelmsford,M01824
UnitedStatesofmerica
Tel:+19786142000
Canada
Thisdigitalapparatuscomplieswith
CNICES-3(ClassB).Theproductshallbe
connectedusingashieldednetworkcable(STP)that
isproperlygrounded.Cetappareilnumériqueest
conformeàlanormeCNNMB-3(classeB).Leproduit
doitêtreconnectéàl'aided'uncâbleréseaublindé
(STP)quiestcorrectementmisàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRF
emissionaccordingtotheClassBlimitofEN55022.
Theproductshallbeconnectedusingashielded
networkcable(STP)thatisproperlygrounded.

Australia/NewZealand
Thisdigitalequipmentfulllstherequirements
forRFemissionaccordingtotheClassBlimitof
S/NZSCISPR32.Theproductshallbeconnected
usingashieldednetworkcable(STP)thatisproperly
grounded.
Safety
Disposalandrecycling
Whenthisproducthasreachedtheendofits
usefullife,disposeofitaccordingtolocallawsand
regulations.Forinformationaboutyournearest
designatedcollectionpoint,contactyourlocal
authorityresponsibleforwastedisposal.Inaccordance
withlocallegislation,penaltiesmaybeapplicablefor
incorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbe
disposedoftogetherwithhouseholdorcommercial
waste.Directive2012/19/EUonwasteelectrical
andelectronicequipment(WEEE)isapplicablein
theEuropeanUnionmemberstates.Toprevent
potentialharmtohumanhealthandtheenvironment,
theproductmustbedisposedofinanapproved
andenvironmentallysaferecyclingprocess.For
informationaboutyournearestdesignatedcollection
point,contactyourlocalauthorityresponsiblefor
wastedisposal.Businessesshouldcontacttheproduct
supplierforinformationabouthowtodisposeofthis
productcorrectly.
Thisproductcomplieswiththerequirementsof
Directive2011/65/EUand2015/863ontherestriction
oftheuseofcertainhazardoussubstancesinelectrical
andelectronicequipment(RoHS).
Contactinformation
xisCommunicationsB
Emdalavägen14
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
axis.com
Warrantyinformation
Forinformationaboutxis’productwarrantyand
theretorelatedinformation,gotoaxis.com/warranty.
Spport
Shouldyourequireanytechnicalassistance,please
contactyourxisreseller.Ifyourquestionscannotbe
answeredimmediately,yourresellerwillforwardyour
queriesthroughtheappropriatechannelstoensurea
rapidresponse.IfyouareconnectedtotheInternet,
youcan:
•ndanswerstoresolvedproblemsintheFQ
database,searchbyproduct,category,orphrase
•reportproblemstoxissupportstaffbylogging
intoyourprivatesupportarea
•chatwithxissupportstaff
•visitxisSupportataxis.com/support
Learnmore!
Visitxislearningcenteraxis.com/academyforuseful
trainings,webinars,tutorialsandguides.


AXISD8004UnmanagedPoESwitch
Safetyinformation
Hazardlevels
DANGER
Indicatesahazardoussituationwhich,ifnotavoided,willresultindeathorseriousinjury.
WARNING
Indicatesahazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderate
injury.
O O
OTICE TICE
TICE
Indicatesasituationwhich,ifnotavoided,couldresultindamagetoproperty.
Othermessagelevels
Important
Indicatessignicantinformationwhichisessentialfortheproducttofunctioncorrectly.
Note
Indicatesusefulinformationwhichhelpsingettingthemostoutoftheproduct.
5

AXISD8004UnmanagedPoESwitch
Safetyinstructions
O O
OTICE TICE
TICE
•Thexisproductshallbeusedincompliancewithlocallawsandregulations.
•Useonlyapplicabletoolswheninstallingthexisproduct.Usingexcessiveforcewith
powertoolscouldcausedamagetotheproduct.
•Donotusechemicals,causticagents,oraerosolcleaners.
•Useacleanclothdampenedwithpurewaterforcleaning.
•Useonlyaccessoriesthatcomplywiththetechnicalspecicationofyourproduct.These
canbeprovidedbyxisorathirdparty.xisrecommendsusingxispowersource
equipmentcompatiblewithyourproduct.
•Useonlysparepartsprovidedbyorrecommendedbyxis.
•Donotattempttorepairtheproductyourself.Contactxissupportoryourxisreseller
forservicematters.
Transportation
O O
OTICE TICE
TICE
•Whentransportingthexisproduct,usetheoriginalpackagingorequivalenttoprevent
damagetotheproduct.
6

AXISD8004UnmanagedPoESwitch
Installthehardware
re-Installation
•Makesuretoplacetheswitchnearapowersource.
•Makesuretokeepenoughventilationbetweentheswitchandthesurroundingobjects.
•Thisproductisintendedforindooruseonly.
•Whenchoosingalocation,keepinmindtheenvironmentalrestrictions.See
Specicationsonpage10
•ForlocationsofLEDsandconnectors,seeHardwareoverviewonpage9
Note
Nosoftwarecongurationisnecessary.
InstallationSteps
1.ttachtherubberfeettothebottomoftheswitch.
2.Fastenthebrackets,ifneeded.
3.ConnectastandardnetworkcabletotheportlabeledNETontheswitch.
4.ConnecttheotherendofthecabletoanetworkoutletalternativelyviaaPCorrouter.
5.Connectanetworkcablefromthepowereddevices(networkcamera)totheswitch,
port1-4.
6.Connectthenetworkcablefromtheswitchtothepowereddevice(networkcamera).
7.Connectthepowercabletotheswitch.
8.ConnectthepowercabletoastandardCoutlet.
Note
Useonlythesuppliedpoweradaptertopowertheswitch.
owerNotice
Theswitchisapower-requireddevice,meaningitwillnotworkuntilitispowered.Considerusing
anUPS(UninterruptedPowerSupply)inordertoavoidnetworkdatalossornetworkdowntime.
7

AXISD8004UnmanagedPoESwitch
Installingasurgesuppressiondevicemayalsohelptoprotecttheswitchfrombeingdamagedby
unregulatedsurgeorcurrenttotheswitchorthepowercord.
8

AXISD8004UnmanagedPoESwitch
Referencematerial
Packagecontents
•XISD8004UnmanagedPoESwitch
•Powerdapter
•PowerCord
•Rubberfeet(4x)
•Bracket(2x)
•PrintedMaterials
-InstallationGuide(thisdocument)
Hardwareoverview
1LEDs(frontpanel)
2Port1-4(PoE)
3PortET(non-PoE)
4PowerConnector
LEDindicators
LEDColorIndication
PWRGreen(lit)Poweron
9

AXISD8004UnmanagedPoESwitch
LEDColorIndication
PortNET(network)Green(lit)10/100Mbpsestablished
PortNET(network)Green(blink)Sendingorreceivingdata
Port1-4(PoE)Orange(lit)PoEon
Port1-4(network)Green(lit)10/100Mbpsestablished
Port1-4(network)Green(blink)Sendingorreceivingdata
ProdctFeatres
•4PoEports
•utodetectionofPoEpowereddevices.
•Desktoppalmsize.
•LEDindicators
•Metalenclosure
Specications
•HardwareSpecications
-NetworkConnector:5–portRJ4510/100Base-TX
-PoEPorts:Port1-4.SupportsIEEE802.3af/802.3atType1Class3,
IEEE802atType2Class4
-MCddresstable:1KMCaddresstablewithutolearningfunctionality
-SwitchedFabric:1Gbps
-SwitchThroughput:0.74Mbps@64Bytes
-MaximumPacketSize:1536Bytes
-Hardwarebased10/100MbpsutoNegotiationandautoMDI/MDI-X
-FlowControl:BackpressureforHalf-Duplex.IEEE802.3xPauseFramefor
Full-Duplex
-PowerConsumption:Max62W
-Powerplugpolarity:Center-pinpositive
-Dimensions:90x8021mm(3.54x3.15x0.83in)
-Weight:172g(0.38lb)
•oweroverEthernet
-PoEStandards:IEEE802.3af/802.3atType1Class3,IEEE802atType2Class4
-PoEPowerSupplyType:Midspan
-PowerPinssignment:4/5(+)and7/8(-)
10

AXISD8004UnmanagedPoESwitch
-PoEPowerBudget:60W(4x15W,2x30Wor1x30W+2x15W)
-Remotepowerfeeding:Upto100m
•Environment
-Theproductisintendedforindooruseonly
-OperatingConditionsTemperature:0°Cto50°C(32°Fto122°F)
-OperatingConditionsHumidity:5to95%RH(non-condensing)
11

12

AXISD8004UnmanagedPoESwitch
Informationssurlascurit
Niveaxderisqes
DANGER
Indiqueunesituationdangereusequi,siellen'estpasévitée,entraîneraledécèsoudes
blessuresgraves.
AVERTISSEMENT
Indiqueunesituationdangereusequi,siellen'estpasévitée,pourraitentraînerledécès
oudesblessuresgraves.
ATTENTION
Indiqueunesituationdangereusequi,siellen'estpasévitée,pourraitentraînerdes
blessureslégèresoumodérées.
A A
AVIS VIS
VIS
Indiqueunesituationqui,siellen'estpasévitée,pourraitendommagerl'appareil.
Atresniveaxdemessage
Important
Indiquelesinformationsimportantes,nécessairespourassurerlebonfonctionnementde
l’appareil.
Note
Indiquelesinformationsutilesquipermettrontd’obtenirlefonctionnementoptimalde
l’appareil.
13

AXISD8004UnmanagedPoESwitch
Consignesdescurit
A A
AVIS VIS
VIS
•Leproduitxisdoitêtreutiliséconformémentauxloisetrèglementslocaux.
•Utiliseruniquementdesoutilsrecommandéspourl'installationdel'appareilxis.
L'applicationd'uneforceexcessivesurl'appareilavecdesoutilspuissantspourrait
l'endommager.
•Nepasutiliserdeproduitschimiques,desubstancescaustiquesoudenettoyants
pressurisés.
•Utiliserunchiffonpropreimbibéd'eaupurepourlenettoyage.
•Utiliseruniquementdesaccessoiresconformesauxcaractéristiquestechniquesdevotre
produit.Ilspeuventêtrefournisparxisouuntiers.xisrecommanded'utiliserun
équipementd'alimentationxiscompatibleavecvotreproduit.
•Utiliseruniquementlespiècesderechangefourniesourecommandéesparxis.
•Nepasessayerderéparervous-mêmeceproduit.Contacterl'assistancetechniqued'xis
ouvotrerevendeurxispourdesproblèmesliésàl'entretien.
Transport
A A
AVIS VIS
VIS
•Lorsdutransportduproduitxis,utilisezl'emballaged'origineouunéquivalentpour
éviterd'endommagerleproduit.
14

AXISD8004UnmanagedPoESwitch
Installationdumatriel
réinstallation
•Placezlecommutateuràproximitéd'unesourced'alimentation.
•Uneventilationsufsantedoitêtreprévueentrelecommutateuretlesobjets
environnants.
•Cetappareilestdestinéàuneutilisationenintérieuruniquement.
•umomentdechoisirunemplacement,n'oubliezpaslescontraintesenvironnementales.
Cf.Caractéristiquestechniquespage18
•Pourconnaîtrel'emplacementdesvoyantsetdesconnecteurs,consultezAperçu
dumatérielpage17
Note
ucunecongurationlogiciellen'estnécessaire.
rocédured’installation
1.Fixezlespiedsencaoutchoucsurlapartieinférieureducommutateur.
2.Fixezlessupports,lecaséchéant.
3.BranchezuncâbleréseaustandardauportidentiéNETsurlecommutateur.
4.Branchezl'autreextrémitéducâbleàunepriseréseauviaunordinateurouunrouteur.
5.Connectezuncâbleréseauvenantdesappareilsalimentés(caméraréseau)au
commutateur,port1-4.
6.Connectezlecâbleréseauvenantducommutateuràl'appareilalimenté(caméraréseau).
7.Connectezlecâblesecteuraucommutateur.
8.Connectezlecâbled'alimentationàuneprisesecteurstandard.
Note
Utilisezuniquementl'adaptateurd'alimentationfournipouralimenterlecommutateur.
Remarqueàproposdel'alimentation
15

AXISD8004UnmanagedPoESwitch
Cecommutateurestunappareilàénergierequise,cequisigniequ'ilnefonctionneques'ilest
alimenté.Pensezàutiliserunsystèmed’alimentationsanscoupure(UPS)pouréviterlespertesde
donnéesréseauoul'arrêtduréseau.
L'installationd'undispositifdeprotectioncontrelessurtensionspeutégalementprotégerle
commutateuroulecordond'alimentationcontreunesurtensionouuncourantnonrégulés.
16

AXISD8004UnmanagedPoESwitch
Élmentsderfrence
Contendel’emballage
•XISD8004UnmanagedPoESwitch
•daptateurd’alimentation
•Cordond'alimentation
•Piedencaoutchouc(4x)
•Support(2x)
•Documentsimprimés
-Guided’installation(cedocument)
Aperçdmatériel
1Voyants(panneauavant)
2Port1à4(PoE)
3PortET(non-PoE)
4Connecteurd’alimentation
Voyants
VoyantCouleurIndication
PWRVert(allumé)Soustension
17

AXISD8004UnmanagedPoESwitch
VoyantCouleurIndication
PortNET(réseau)Vert(allumé)10/100Mbit/sétabli.
PortNET(réseau)Vert(clignotant)Envoiouréceptiondedonnées
Port1à4(PoE)Orange(allumé)limentationparEthernet
(PoE)activée
Port1-4(réseau)Vert(allumé)10/100Mbit/sétabli.
Port1-4(réseau)Vert(clignotant)Envoiouréceptiondedonnées
Caractéristiqesdprodit
•4portsPoE
•Détectionautomatiqued'appareilsalimentésparPoE.
•Faibleencombrement.
•Voyants
•Boîtiermétallique
Caractéristiqestechniqes
•Caractéristiquesmatérielles
-Connecteurréseau:RJ455ports10/100Base-TX
-PortsPoE:Port1-4.CompatibleIEEE802.3af/802.3atType1Classe3,
IEEE802atType2Classe4
-TableauadressesMC:tableauadresses1KMCavecfonctionnalité
d'auto-apprentissage
-Matricedecommutation:1Gbit/s
-Débitducommutateur:0,74Mbit/s@64octets
-Taillemaxi.despaquets:1536octets
-Négociationautomatique10/100Mbit/sbaséesurlematérielet
MDI/MDI-Xauto
-Commandedeux:contre-pressionpoursemi-duplex.tramedepause
IEEE802.3xpourduplexintégral
-Consommationélectrique:Max.62W
-Polaritéducordond’alimentation:Brochecentralepositive
-Dimensions:90x80x21mm(3,54x3,15x0,83po)
-Poids:172g(0,38lb)
•AlimentationparEthernet
18

AXISD8004UnmanagedPoESwitch
-NormesPoE:IEEE802.3af/802.3atType1Classe3,IEEE802atType2Classe4
-Typed’alimentationélectriquePoE:Injecteur
-ffectationdesbrochesd'alimentation:4/5(+)et7/8(-)
-Budgetdel'alimentationPoE:60W(4x15W,2x30Wou1x30W+
2x15W)
-Téléalimentation:Jusqu'à100m
•Environnement
-L'appareilestdestinéàuneutilisationenintérieuruniquement.
-Températureenconditionsd'utilisation:de0°Cà50°C(32°Fà122°F)
-Humiditéenconditionsd'utilisation:Humiditérelativede5à95%(sans
condensation)
19

20
Table of contents
Languages:
Other Axis Switch manuals

Axis
Axis F44 User manual

Axis
Axis T86 Series User manual

Axis
Axis T8604 User manual

Axis
Axis 2N Access Unit Instruction sheet

Axis
Axis T8504-E User manual

Axis
Axis Dome Intrusion Switch C User manual

Axis
Axis T8121 User manual

Axis
Axis T8516 User manual

Axis
Axis 30 W Midspan AC/DC User manual

Axis
Axis 5801-694 User manual