Axis F44 User manual

INSTALLATIONGUIDE
AXISF44MainUnit
ENGLISH
FRANÇAIS
DEUTSCH
ITALIANO
ESPANÕL
ò
ò
¨
¨
¾
¾
InstallationGuide

LegalConsiderations
Videoandaudiosurveillancecanberegulatedby
lawsthatvaryfromcountrytocountry.Checkthe
lawsinyourlocalregionbeforeusingthisproduct
forsurveillancepurposes.
Thisproductincludesone(1)H.24decoderlicense
andone(1)AACdecoderlicense.Topurchasefurther
licenses,contactyourreseller.
Liability
Everycarehasbeentakeninthepreparationofthis
document.PleaseinformyourlocalAxisofceof
anyinaccuraciesoromissions.AxisCommunications
ABcannotbeheldresponsibleforanytechnicalor
typographicalerrorsandreservestherighttomake
changestotheproductandmanualswithoutprior
notice.AxisCommunicationsABmakesnowarranty
ofanykindwithregardtothematerialcontained
withinthisdocument,including,butnotlimitedto,
theimpliedwarrantiesofmerchantabilityandtness
foraparticularpurpose.AxisCommunicationsAB
shallnotbeliablenorresponsibleforincidental
orconsequentialdamagesinconnectionwiththe
furnishing,performanceoruseofthismaterial.This
productisonlytobeusedforitsintendedpurpose.
IntellectualropertyRights
AxisABhasintellectualpropertyrightsrelatingto
technologyembodiedintheproductdescribedinthis
document.Inparticular,andwithoutlimitation,these
intellectualpropertyrightsmayincludeoneormore
ofthepatentslistedatwww.axis.com/patent.htmand
oneormoreadditionalpatentsorpendingpatent
applicationsintheUSandothercountries.
Thisproductcontainslicensedthird-partysoftware.
Seethemenuitem“About”intheproduct’suser
interfaceformoreinformation.
Thisproductcontainssourcecodecopyright
AppleComputer,Inc.,undertheterms
ofApplePublicSourceLicense2.0(see
www.opensource.apple.com/apsl).Thesourcecodeis
availablefromhttps://developer.apple.com/bonjour/
EquipmentModications
Thisequipmentmustbeinstalledandusedin
strictaccordancewiththeinstructionsgivenin
theuserdocumentation.Thisequipmentcontains
nouser-serviceablecomponents.Unauthorized
equipmentchangesormodicationswillinvalidate
allapplicableregulatorycerticationsandapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPEC
andVAPIXareregisteredtrademarksortrademark
applicationsofAxisABinvariousjurisdictions.All
othercompanynamesandproductsaretrademarksor
registeredtrademarksoftheirrespectivecompanies.
Apple,Boa,Apache,Bonjour,Ethernet,Internet
Explorer,Linux,Microsoft,Mozilla,Real,SMPTE,
QuickTime,UNIX,Windows,WindowsVistaand
WWWareregisteredtrademarksoftherespective
holders.JavaandallJava-basedtrademarksand
logosaretrademarksorregisteredtrademarksof
Oracleand/oritsafliates.UPnPTMisacertication
markoftheUPnPTMImplementersCorporation.
SD,SDHCandSDXCaretrademarksorregistered
trademarksofSD-3C,LLCintheUnitedStates,
othercountriesorboth.Also,miniSD,microSD,
miniSDHC,microSDHC,microSDXCarealltrademarks
orregisteredtrademarksofSD-3C,LLCintheUnited
States,othercountriesorboth.
RegulatoryInformation
Europe
Thisproductcomplieswiththeapplicable
CEmarkingdirectivesandharmonizedstandards:
•ElectromagneticCompatibility(EMC)
Directive2004/108/EC.SeeElectromagnetic
Compatibility(EMC)onpage2.
•LowVoltage(LVD)Directive200/95/EC.See
afetyonpage3.
•RestrictionsofHazardousSubstances(RoHS)
Directive2011/5/EU.SeeDisposaland
Recyclingonpage3.
Acopyoftheoriginaldeclarationofconformity
maybeobtainedfromAxisCommunicationsAB.See
ContactInformationonpage3.
ElectromagneticCompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulll
applicablestandardsfor:
•Radiofrequencyemissionwheninstalled
accordingtotheinstructionsandusedinits
intendedenvironment.
•Immunitytoelectricalandelectromagnetic
phenomenawheninstalledaccordingto
theinstructionsandusedinitsintended
environment.
USA
Thisequipmenthasbeentestedusingashielded
networkcable(STP)andfoundtocomplywiththe
limitsforaClassAdigitaldevice,pursuanttopart15
oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterference
whentheequipmentisoperatedinacommercial
environment.Thisequipmentgenerates,uses,and
canradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstruction
manual,maycauseharmfulinterferencetoradio
communications.Operationofthisequipmentina
residentialareaislikelytocauseharmfulinterference
inwhichcasetheuserwillberequiredtocorrectthe
interferenceathisownexpense.
Theproductshallbeconnectedusingashielded
networkcable(STP)thatisproperlygrounded.
Canada
Thisdigitalapparatuscomplieswith
CANICES-3(ClassA).Theproductshallbe
connectedusingashieldednetworkcable(STP)that
isproperlygrounded.
Cetappareilnumériqueestconformeàlanorme

NMBICES-3(classeA).Leproduitdoitêtreconnecté
àl'aided'uncâbleréseaublindé(STP)quiest
correctementmisàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRF
emissionaccordingtotheClassAlimitofEN55022.
Theproductshallbeconnectedusingashielded
networkcable(STP)thatisproperlygrounded.Notice!
ThisisaClassAproduct.Inadomesticenvironment
thisproductmaycauseRFinterference,inwhichcase
theusermayberequiredtotakeadequatemeasures.
Thisproductfulllstherequirementsforemission
andimmunityaccordingtoEN50121-4and
IEC223-4railwayapplications.
Thisproductfulllstherequirementsforimmunity
accordingtoEN1000--1residential,commercial
andlight-industrialenvironments.
Thisproductfulllstherequirementsforimmunity
accordingtoEN1000--2industrialenvironments.
Thisproductfulllstherequirementsforimmunity
accordingtoEN55024ofceandcommercial
environments
Australia/NewZealand
Thisdigitalequipmentfulllstherequirements
forRFemissionaccordingtotheClassAlimitof
AS/NZSCISPR22.Theproductshallbeconnected
usingashieldednetworkcable(STP)thatisproperly
grounded.Notice!ThisisaClassAproduct.Ina
domesticenvironmentthisproductmaycauseRF
interference,inwhichcasetheusermayberequired
totakeadequatemeasures.
Japan
この装置は、クラスA情報技術装置です。こ
の装置を家庭環境で使用すると電波妨害を引
き起こすことがあります。この場合には使用
者が適切な対策を講ずるよう要求されるこ
とがあります。本製品は、シールドネット
ワークケーブル(STP)を使用して接続してくだ
さい。また適切に接地してください。
Korea
이기기는업무용(A급)전자파적합기기로서
판매자또는사용자는이점을주의하시기
바라며,가정외의지역에서사용하는것을목
적으로합니다.적절히접지된STP(shielded
twistedpair)케이블을사용하여제품을연
결하십시오.
Safety
ThisproductcomplieswithIEC/EN/UL0950-1,
SafetyofInformationTechnologyEquipment.Ifits
connectingcablesareroutedoutdoors,theproduct
shallbegroundedeitherthroughashieldednetwork
cable(STP)orotherappropriatemethod.
Thepowersupplyusedwiththisproductshallfulll
therequirementsforSafetyExtraLowVoltage
(SELV)andLimitedPowerSource(LPS)accordingto
IEC/EN/UL0950-1.
DisposalandRecycling
Whenthisproducthasreachedtheendofits
usefullife,disposeofitaccordingtolocallaws
andregulations.Forinformationaboutyour
nearestdesignatedcollectionpoint,contactyour
localauthorityresponsibleforwastedisposal.In
accordancewithlocallegislation,penaltiesmaybe
applicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshall
notbedisposedoftogetherwithhouseholdor
commercialwaste.Directive2012/19/EUonwaste
electricalandelectronicequipment(WEEE)is
applicableintheEuropeanUnionmemberstates.
Topreventpotentialharmtohumanhealthandthe
environment,theproductmustbedisposedofinan
approvedandenvironmentallysaferecyclingprocess.
Forinformationaboutyournearestdesignated
collectionpoint,contactyourlocalauthority
responsibleforwastedisposal.Businessesshould
contacttheproductsupplierforinformationabout
howtodisposeofthisproductcorrectly.
Thisproductcomplieswiththerequirementsof
Directive2011/5/EUontherestrictionoftheuse
ofcertainhazardoussubstancesinelectricaland
electronicequipment(RoHS).
China
Thisproductcomplieswiththerequirements
ofthelegislativeactAdministrationontheControlof
PollutionCausedbyElectronicInformationProducts
(ACPEIP).
ContactInformation
AxisCommunicationsAB
Emdalavägen14
2239Lund
Sweden
Tel:+442721800
Fax:+4413130
www.axis.com
Support
Shouldyourequireanytechnicalassistance,please
contactyourAxisreseller.Ifyourquestionscannot
beansweredimmediately,yourresellerwillforward
yourqueriesthroughtheappropriatechannelsto
ensurearapidresponse.Ifyouareconnectedtothe
Internet,youcan:
•downloaduserdocumentationandsoftware
updates
•ndanswerstoresolvedproblemsintheFAQ
database.Searchbyproduct,category,or
phrase
•reportproblemstoAxissupportstaffbylogging
intoyourprivatesupportarea

•chatwithAxissupportstaff(selectedcountries
only)
•visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/for
usefultrainings,webinars,tutorialsandguides.

AXISF44MainUnit
SafetyInformation
ReadthroughthisInstallationGuidecarefullybeforeinstallingtheproduct.
KeeptheInstallationGuideforfuturereference.
HazardLevels
DANGERIndicatesahazardoussituationwhich,ifnot
avoided,willresultindeathorseriousinjury.
WARNINGIndicatesahazardoussituationwhich,ifnot
avoided,couldresultindeathorseriousinjury.
CAUTIONIndicatesahazardoussituationwhich,ifnot
avoided,couldresultinminorormoderateinjury.
NO NO
NOTICE TICE
TICEIndicatesasituationwhich,ifnotavoided,could
resultindamagetoproperty.
OtherMessageLevels
ImportantIndicatessignicantinformationwhichis
essentialfortheproducttofunctioncorrectly.
NoteIndicatesusefulinformationwhichhelpsin
gettingthemostoutoftheproduct.
5
ENGLISH

AXISF44MainUnit
SafetyInstructions
NO NO
NOTICE TICE
TICE
•TheAxisproductshallbeusedincompliancewithlocallaws
andregulations.
•TousetheAxisproductoutdoors,orinsimilarenvironments,it
shallbeinstalledinanapprovedoutdoorhousing.
•StoretheAxisproductinadryandventilatedenvironment.
•AvoidexposingtheAxisproducttoshocksorheavypressure.
•Donotinstalltheproductonunstablebrackets,surfacesor
walls.
•UseonlyapplicabletoolswheninstallingtheAxisproduct.
Excessiveforcecouldcausedamagetotheproduct.
•Donotusechemicals,causticagents,oraerosolcleaners.
•Useacleanclothdampenedwithpurewaterforcleaning.
•Useonlyaccessoriesthatcomplywithtechnicalspecicationof
theproduct.ThesecanbeprovidedbyAxisorathirdparty.
•UseonlysparepartsprovidedbyorrecommendedbyAxis.
•Donotattempttorepairtheproductbyyourself.ContactAxis
supportoryourAxisresellerforservicematters.
Transportation
NO NO
NOTICE TICE
TICE
•WhentransportingtheAxisproduct,usetheoriginalpackaging
orequivalenttopreventdamagetotheproduct.
Battery
TheAxisproductusesa3.0VBR/CR2032lithiumbatteryasthepower
supplyforitsinternalreal-timeclock(RTC).Undernormalconditionsthis
batterywilllastforaminimumofveyears.
6

AXISF44MainUnit
LowbatterypoweraffectstheoperationoftheRTC,causingittoresetat
everypower-up.Whenthebatteryneedsreplacing,alogmessagewill
appearintheproduct’sserverreport.Formoreinformationaboutthe
serverreport,seetheproduct´ssetuppagesorcontactAxissupport.
Thebatteryshouldnotbereplacedunlessrequired,butifthebattery
doesneedreplacing,contactAxissupportatwww.axis.com/techsupfor
assistance.
WARNING
•Riskofexplosionifthebatteryisincorrectlyreplaced.
•Replaceonlywithanidenticalbatteryorabatterywhichis
recommendedbyAxis.
•Disposeofusedbatteriesaccordingtolocalregulationsorthe
batterymanufacturer'sinstructions.
7
ENGLISH

8

AXISF44MainUnit
InstallationGuide
ThisInstallationGuideprovidesinstructionsforinstallingAXISF44Main
Unitonyournetwork.Forotheraspectsofusingtheproduct,seetheUser
Manualavailableatwww.axis.com
InstallationSteps
1.Makesurethepackagecontents,toolsandothermaterials
necessaryfortheinstallationareinorder.Seepage9.
2.Studythehardwareoverview.Seepage10.
3.Studythespecications.Seepage15.
4.Installthehardware.Seepage19.
5.Accesstheproduct.Seepage20.
ackageContents
•AXISF44MainUnit
•2–pinpowerconnectorblock
•–pinI/Oconnectorblock
•5–pinRS232connectorblock
•InstallationandManagementSoftwareCD
•Printedmaterials
-InstallationGuide(thisdocument)
-Extraserialnumberlabel(2x)
-AVHSAuthenticationkey
RecommendedTools
•TorxscrewdriverT20toremovetheplasticcoverbottom
OptionalAccessories
•AXISF8001SurfaceMountwithStrainRelief
9
ENGLISH

AXISF44MainUnit
•AXISF8002DINRailClip
Forinformationaboutavailableaccessories,seewww.axis.com
HardwareOverview
1
2
34
56
789
10 11
1.Controlbutton
2.Dcardslots
3.LEDs(Power,tatus,Network)
4.RJ12connector(4nos.)
5.Audioin
6.Audioout
7.I/Oconnector
8.Powerconnector
9.Networkconnector(PoE)
10.R232connector
11.Plasticbottomplate
ShortenSensorUnitCable
Thesensorunitisdeliveredwithacable.Toshortenthecablefollow
thesesteps:
10

AXISF44MainUnit
1.Cutthecabletothedesiredlength.Measurefromthesensor
unit.
2.Striptheplasticoutercoatingfromtheendofthecable.
3.Peelbacktheshield.
4.Flattenthecoloredwiresintheorderdescribedbelow.
1Brown
2White/brown
3Notused
4Notused
5White/blue
Blue
5.InsertthewiresallthewayintoashieldedPCRJ12
connector.
NO NO
NOTICE TICE
TICE
Makesurethatthewiresstayinthecorrectorderandthatthe
cableshieldmakesgoodcontactwiththeconnectorshield.
.Useacrimpingtooltofastentheconnectortothecable.
11
ENGLISH

AXISF44MainUnit
14 mm 14 mm
LEDIndicators
EDColorIndication
GreenSteadyforconnectiontoa100Mbit/snetwork.
Flashesfornetworkactivity.
Am-
berSteadyforconnectiontoa10Mbit/snetwork.Flashes
fornetworkactivity.
Net-
work
UnlitNonetworkconnection.
GreenSteadygreenfornormaloperation.
Am-
berSteadyduringstartupandwhenrestoringsettings.
Sta-
tus
RedSlowashforfailedupgrade.
12

AXISF44MainUnit
GreenNormaloperation. Po-
werAm-
berFlashesgreen/amberduringrmwareupgrade.
Note
•TheStatusLEDcanbeconguredtobeunlitduringnormal
operation.Tocongure,gotoSetup>SystemOptions>Ports
&Devices>ED.Seetheonlinehelpformoreinformation.
•TheStatusLEDcanbeconguredtoashwhileaneventis
active.
•TheStatusLEDcanbeconguredtoashforidentifyingthe
unit.GotoSetup>SystemOptions>Maintenance.
•TheNetworkLEDcanbedisabledsothatitdoesnotashwhen
thereisnetworktrafc.Tocongure,gotoSetup>System
Options>Ports&Devices>ED.Seetheonlinehelpformore
information.
ConnectorsandButtons
Forspecicationsandoperatingconditions,seepage15.
NetworkConnector
RJ45EthernetconnectorwithPoweroverEthernet(PoE).
NO NO
NOTICE TICE
TICE
Theproductshallbeconnectedusingashieldednetworkcable
(STP).Allcablesconnectingtheproducttothenetworkshall
beintendedfortheirspecicuse.Makesurethatthenetwork
devicesareinstalledinaccordancewiththemanufacturer’s
instructions.Forinformationaboutregulatoryrequirements,see
ElectromagneticCompatibility(EMC)onpage2.
13
ENGLISH

AXISF44MainUnit
I/OConnector
Usewithexternaldevicesincombinationwith,forexample,tampering
alarms,motiondetection,eventtriggering,timelapserecordingandalarm
notications.Inadditiontothe0VDCreferencepointandpower(DC
output),theI/Oconnectorprovidestheinterfaceto:
•Digitaloutput–Forconnectingexternaldevicessuchasrelays
andLEDs.ConnecteddevicescanbeactivatedbytheVAPIX®
ApplicationProgrammingInterface,outputbuttonsonthe
LiveViewpageorbyanActionRule.Theoutputwillshowas
active(shownunderSystemOptions>Ports&Devices)if
thealarmdeviceisactivated.
•Digitalinput–Analarminputforconnectingdevicesthat
cantogglebetweenanopenandclosedcircuit,forexample:
PIRs,door/windowcontacts,glassbreakdetectors,etc.When
asignalisreceivedthestatechangesandtheinputbecomes
active(shownunderSystemOptions>Ports&Devices).
owerConnector
2-pinterminalblockforpowerinput.UseaSafetyExtraLowVoltage
(SELV)compliantlimitedpowersource(LPS)witheitheraratedoutput
powerlimitedto≤100Woraratedoutputcurrentlimitedto≤5A.
AudioConnector
TheAxisproducthasthefollowingaudioconnectors:
•Audioin–3.5mminputforamonomicrophone,oraline-in
monosignal(leftchannelisusedfromastereosignal).
•Audioout–3.5mmoutputforaudio(linelevel)thatcanbe
connectedtoapublicaddress(PA)systemoranactivespeaker
withabuilt-inamplier.Astereoconnectormustbeused
foraudioout.
14

AXISF44MainUnit
RS232Connector
5-pinterminalblockfortheRS232serialinterfaceusedtocontrolauxiliary
equipment.InordertousetheRS232port,athirdpartyapplicationfor
AXISCameraApplicationPlatformisrequired.
RJ12Connector
TheRJ12connectorisusedforconnectingthesensorunittothemain
unit.Forinformationonhowtoshortenthesensorunitcableseehorten
ensorUnitCableonpage10.
SDCardSlot
AnSDcard(notincluded)canbeusedforlocalrecordingwithremovable
storage.Formoreinformation,seepecicationsonpage15.
NO NO
NOTICE TICE
TICE
Topreventcorruptionofrecordings,theSDcardshouldbe
unmountedbeforeremoval.Tounmount,gotoSetup>System
Options>Storage>SDCardandclickUnmount.
Note
ForSDcardrecommendationsseewww.axis.com
ControlButton
Thecontrolbuttonisusedfor:
•Resettingtheproducttofactorydefaultsettings.Seepage21.
•ConnectingtoanAXISVideoHostingSystemserviceorAXIS
InternetDynamicDNSService.Formoreinformationabout
theseservices,seetheUserManual.
Specications
TheAxisproductisintendedforindooruse.
15
ENGLISH

AXISF44MainUnit
ProductClassica-
tionTemperatureHumidity
AXISF44IEC/EN05
29-30°Cto0°C
(-22°Fto
140°F)
10-85%RH
(non-condensing)
Connectors
I/OConnector
–pinterminalblockfor:
•Auxiliarypower
(DCoutput)
•DigitalInput
•DigitalOutput
•0VDC(-)
12 3 4 5 6
Func-
tionP-
i-
n
NotesSpecications
0VDC(-)10VDC
DC
output2Canbeusedtopowerauxiliary
equipment.
Note:Thispincanonlybeused
aspowerout.
12VDC
Maxload=50mA
16

AXISF44MainUnit
Digitalinput–Connecttopin
1toactivate,orleaveoating
(unconnected)todeactivate.
0tomax30VDC Cong-
urable
(Inputor
Output)
3
–
Digitaloutput–Connected
topin1whenactivated,
oating(unconnected)when
deactivated.Ifusedwithan
inductiveload,e.g.arelay,
adiodemustbeconnected
inparallelwiththeload,for
protectionagainstvoltage
transients.
0tomax30VDC,
opendrain,
100mA
1
2
E.g. push button
3
4
12 V
max 50 mA
D
S
G
17
ENGLISH

AXISF44MainUnit
owerConnector
2-pinterminalblock
forpowerinput.
UseaSafetyExtra
LowVoltage(SELV)
compliantlimited
powersource(LPS)
witheitherarated
outputpower
limitedto≤100Wor
aratedoutput
currentlimitedto
≤5A.
DCpower
input
AudioConnector
3.5mmaudio
connectors
(stereo)
123
1Tip2Ring3
Sleeve
Audio
InputMicrophone/LineinGround
Audio
OutputLineout(mono)Ground
18

AXISF44MainUnit
RS232Connector
5-pinterminalblockfortheRS232serialinterfaceusedtocontrolauxiliary
equipment.Theportcanbeusedinthefollowingmodes:
•2TX/2RXRS-232interface(TXD,RTS,GND,CTS,RXD)
FunctionPinNotes
RS232TDalt1
RS232RTSalt2
RS-232DriverOutput
RS232GND3Ground
RS232CTSalt4
RS232RDalt5
RS-232ReceiverInput
SDCardSlot
TheAxisproductsupportsSDcardswithupto4GBofstorage.Forbest
recordingperformance,useultra-highspeedSDcards(SDHCUHS-Ior
SDXCUHS-I).
InstalltheHardware
TheAxisF41/F44MainUnitcanbeplacedonatabledesktopormounted
onaDINrail.Tofacilitateroutingthecablesfromthetoporsideremove
the4screws(TorxT20)andsuitablyrealignthebottomplateunderthe
unit(seeHardwareOverviewonpage10).Seewww.axis.comforoptional
accessories.
19
ENGLISH

AXISF44MainUnit
1.Ifrequired,presstoreleasethedummySDcardandinsertan
SDmemorycardintheSDmemorycardslot.
2.Attachthenetworkcabletoconnecttheunittothenetwork.
3.ConnectthesensorunittothemainunitwiththeRJ12cable.
4.Ifrequired,connectanAC/DCpowersupplytothepower
connector.
5.Ifrequired,attachtheI/Ocableusingthe–pinI/Oconnector
blocktoconnectexternalinput/outputdevices.
.Ifrequired,attachtheaudiocablestoconnectanactive
speaker/externalmicrophone.
7.Ifrequired,attachtheRS232cabletoconnecttoauxiliary
equipment.
Accesstheroduct
UsethetoolsprovidedontheInstallationandManagementSoftware
CDtoassignanIPaddress,setthepasswordandaccessthevideo
stream.Thisinformationisalsoavailablefromthesupportpageson
www.axis.com/techsup/
20
Other manuals for F44
3
Table of contents
Languages:
Other Axis Switch manuals

Axis
Axis 5801-694 User manual

Axis
Axis F41 User manual

Axis
Axis T8504-R User manual

Axis
Axis T8504-E User manual

Axis
Axis T8120 Midspan 1-port User manual

Axis
Axis Dome Intrusion Switch C User manual

Axis
Axis T8125 User manual

Axis
Axis 2N Access Unit Instruction sheet

Axis
Axis T8121 User manual

Axis
Axis T8524 PoE+ User manual