baracuda titan 2 Eco 3 Manual

E
Installation & Operating Instructions
500-6470 TI2ECO3_BOOKLET_VER.A

2BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
Thank you for choosing a Baracuda product.
This product has been manufactured using modern production methods
and extensive quality assurance procedures, because our goal is to ensure
that you, the customer, are satisfied with our products.
Fluidra is continually striving to further develop and improve its range of
products; we therefore reserve the right to make alterations to the form,
technical specifications and equipment level of our standard equipment.
The information in this manual is therefore subject to change.
DECLARATION OF CONFORMITY
This product range conforms to the relevant Compulsory Specifications.
An electronic
version of this manual
may be found on
www.baracuda.co.za

3
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
IMPORTANT SAFETY INSTRUCTIONS
3
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
IMPORTANT SAFETY INSTRUCTIONS
Warning: Please make sure you observe the following safety
instructions. Failure to observe the safety instructions may result in
fatal injury.
Please read this instruction manual before using the product for the
first time and keep in a safe place for future reference.
• In order to provide a hassle-free experience, we recommend the use of a
qualied technician to complete the installations of our products, and to
ensure that the installation complies with all relevant regulations.
• Please note - the electrical connection should be completed by a certied
electrician (any non-compliance will result in the warranty being voided).
• Installations must conform to SANS 10142 and all relevant local by-laws.
• The pump must be supplied through a residual current device (RCD) with
a rated residual operating current not exceeding 30mA
in accordance with IEC 60335-2-41.
• Do not modify the terminal lid and/or box of the pump.
• The motor is initially supplied with an electrical cable which may be used
for testing purposes only (please follow the guidelines in SANS 10142 for
installation).
• The pump must be installed in a weatherproof, well ventilated enclosure.
• Allow sufcient space around the pump for ventilation and do not obstruct the
motor fan.
• It is imperative that you do not store pool chemicals in this enclosure.
• The pump motor’s Ingress Protection (IP) rating is indicated on the information
plate situated on the pump. Please note - the pump is not submersible.
• Never run the pump dry, i.e. without water in the pre-lter.
• This product is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are under supervision or instruction concerning use of
the product by a person responsible for their safety.
• Children should be supervised, at all times to ensure they do not play with or
near the product.
• Only a qualied person/s, should perform repairs and/or maintenance
work on the pump and motor, including any cabling work to the motor.

4BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
WARNINGS
4BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
• Failure to respect the warnings may cause serious damage to the pool
equipment or cause serious injury, even death.
• The appliance is intended to be used only for swimming pools and spas;
it must not be used for any purpose other than that for which it has been
designed.
• It is important that the appliance is operated by people who are competent
and qualied (both physically and mentally), after having read the instructions
for use. All persons not meeting these criteria must not approach the
appliance in order to avoid exposure to dangerous elements.
• Keep the appliance out of the reach of children.
• The appliance must be installed according to the manufacturer's instructions
and in compliance with local standards. The installer is responsible for
installing the appliance and for compliance with national installation
regulations. Under no circumstances may the manufacturer be held liable in
the event of failure to comply with applicable local installation standards, see
also INSTALLATION.
• Incorrect installation and/or use may cause serious damage to property or
serious injuries (possibly causing death).
• If the appliance suffers a malfunction, do not try to repair the appliance
yourself. Instead contact a qualied technician for service.
• Refer to the warranty conditions for details of the permitted water balance
values for operating the appliance.
• Defeating, eliminating or shunting any of the safety that may be a part of the
device automatically voids the warranty, as does the use of unauthorized,
third party replacement parts.
• Do not spray insecticide or any other chemical (inammable or
non-inammable) in the direction of the appliance, as this may damage the
body and cause a re.
WARNINGS

5
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
5
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
• The power supply to the appliance must be protected by a dedicated 30
mA residual current device, complying with the standards and regulations
in force in the country in which it is installed.
• Before carrying out any operations, check that:
• The voltage indicated on the appliance information plate corresponds
to the mains voltage,
• The power grid is adapted to the power requirements of the appliance,
and is properly grounded.
• In the event of abnormal operation or the release of odours from the
appliance, turn it off immediately, unplug it from its power supply and
contact a professional.
• Before any access to the appliance for any required service or mainte-
nance, ensure that it is switched off and disconnected from the power
supply.
• Do not disconnect and reconnect the appliance to the power supply when
in operation.
• Do not attempt to carry out any service or maintenance with wet hands or
while the appliance is wet.
• For any component or sub-assembly containing a battery: do not
recharge or dismantle the battery, or throw it into a re. Do not expose it
to high temperatures or direct sunlight.
• In stormy weather, switch off power supply to the appliance to prevent it
from suffering lightning damage.
• Do not immerse the appliance in water or mud.
• This appliance is compatible with all types of water treatment used in
swimming pools. Refer to the Baracuda® warranty conditions for details
of the permitted water balance values.
• Never run the pump dry or without water as this will void the warranty.

6BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
INSTALLATION
6BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
INSTALLATION
• Position the pump on a rm, at, level surface that is not exposed to ooding.
• A minimum of 50mm PVC pipe to be used on the suction and return lines.
• If solvent weld is used in the installation, allow 24 hours to dry, before running
the pump for the rst time.
• A certified electrician must do the electrical connection
in accordance with SANS 10142:
• The voltage of the mains supply to the pool distribution board must corre-
spond to the indicated voltage of the product.
• Follow all other guidelines in SANS 10142 for installation.
• Ensure that there is no strain on the electrical cable.
CONNECTING THE MOTOR’S POWER SUPPLY
Close the electrical connection box, making sure that the
seal isJOplace and tighten theDPWFSscrews.
230 Vac - 50 Hz power supply= connection
to the (earth) and N-L terminals.
• Before starting the motor for the rst time or after the pump has been drained,
open the lid of the pump leaf basket and add water to ll the basket.
• Replace the lid and tighten by hand, ensuring that the lid O-ring / gasket is
tted correctly on the pump body.
• Do not over tighten the pump lid retainer(s).
• Weekly pool maintenance is required. It is important that the weir/skimmer
baskets and/or any leaves or debris are removed from the pump basket
before backwashing.
• The backwash and rinse procedure must be done, as a minimum, every week
to maintain water clarity and ensure adequate ltration of your pool.

7
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
7
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
HYDRAULIC CONNECTIONS
Respect the direction of hydraulic connection. (See page image.)
• Choose the dimension of the pipes according to the size of the pool and
respecting the hydraulic rules which apply in the country of installation.
• For hydraulic connections, use either of the provided unions and the
respective 50/63mm reducer to the respective pipe diameter.
Fit a check valve if the filter is installed above the water level.
• Fit suction and discharge isolation valves if the pump is installed below
the water level.
• To help prevent difficulty in priming, install the suction pipe without high
points, which can trap air.
• Check that the hydraulic coOOections are correctly tightened and
that there are no leaks.
• The pipes must be supported to prevent any risk of breakage due
to the weight of the water.
APump
BFilter
CHeating system
DWater treatment system
Use as few elbow joints as possible. If there needs to be more than 10 elbow joints on
the hydraulic circuit, increase the pipe diameter.

8BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
OPERATION, MAINTENANCE & CARE
8BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
OPERATION, MAINTENANCE AND CARE
o
Switch the pump off before doing any
maintenance, cleaning or other work.
o
Only perform maintenance/care work that
is mentioned in the instruction manual.
• All other work must be performed by a qualied person.
• In the interest of safety and reliability, only use genuine
Baracuda spare parts, in the event that pirate spare parts
are used, the warranty will become null and void.
• Never run the pump dry, i.e. without water in pump wet end,
as this will damage the pump.
• It is important to clean the pump leaf basket regularly.
• Clean plastic parts with a damp cloth. Cleaning agents can cause
damage to the plastic parts.
• Do not spray down the electrical components with water.
• Suction pipe
length = 4 x (2)
• Suction pipe too short
• Risk of cavitation
• Air retention
• Risk of incorrect
pre- lter lling
ELECTRICAL INSTALLATION
A separate time clock or saltwater chlorinator with a timer is recommended to
control the On/Off functions.
8BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
OPERATION, MAINTENANCE AND CARE
o
Switch the pump off before doing any
maintenance, cleaning or other work.
o
Only perform maintenance/care work that
is mentioned in the instruction manual.
• All other work must be performed by a qualied person.
• In the interest of safety and reliability, only use genuine
Baracuda spare parts, in the event that pirate spare parts
are used, the warranty will become null and void.
• Never run the pump dry, i.e. without water in pump wet end,
as this will damage the pump.
• It is important to clean the pump leaf basket regularly.
• Clean plastic parts with a damp cloth. Cleaning agents can cause
damage to the plastic parts.
• Do not spray down the electrical components with water.
• Suction pipe
length = 4 x (2)
• Suction pipe too short
• Risk of cavitation
• Air retention
• Risk of incorrect
pre- lter lling
ELECTRICAL INSTALLATION
A separate time clock or saltwater chlorinator with a timer is recommended to
control the On/Off functions.

9
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
9
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
• The pump is equipped with a thermal overload protection.
If overload occurs during operation, the built in overload
protection automatically deactivates the pump. The pump will
switch on automatically after a cooling period of approximately
20 (twenty) minutes. Ensure the cause of the overload is identied
and addressed . If the pump remains on a continuous locked
situation causing thermal overload, the motor may eventually
damage and burn out.
• Note that certain parts are subject to normal wear and tear, even
when used properly and must be replaced in due time, depending
on type and duration of use.
These include but are not limited to:
• Impeller
• Shaft Seal
• Motor Bearings
• Pump lid and O-ring
• Pump basket
• Diffuser
• All work listed in this manual must be performed regularly.
If this maintenance work cannot be performed by the end-user,
an authorised person must be commissioned to perform this work.
If these operations are neglected, faults may arise which are the
responsibility of the user.
These include:
• Damage to the motor, due to untimely or inadequate
maintenance or cleaning of the cooling fan cover
• Corrosive or other damage caused by incorrect storage
of chemicals in pump enclosure
• Damage due to the use of spare parts which are not
original Baracuda parts
• Damage due to maintenance and repair work not
carried out by qualied technicians
• To avoid personal injury do not have the pool pump running whilst
there are people in the pool/spa.

10 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
SERVICE & REPAIR PARTS
10 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
SERVICE & REPAIR PARTS
Refer all service to your local agent or dealer as their knowledge of your
equipment makes them the best qualied source of information. Order all repair
parts through your dealer.
Give the following information when ordering repair parts:
1. Unit nameplate data or serial number on label.
2. Description of part.

11
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
USE
11
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
USE
1. Operating principle
• The ltration pump forms the core of the pool and is essential as it is used to
circulate water through the pool’s different components, in particular the lter.
Its motor drives the turbine in rotation, which drives the water.
The large strainer of the pre-lter collects major debris to prevent the lter
from becoming clogged too quickly or from becoming damaged.
2. User interface presentation
BUTTON DESIGNATION
ECO
KEY “ECO” speed activation
LED Flashing: in priming mode (approx. 2 minutes on start-up)
MED
KEY “MED” speed activation
LED Flashing: in priming mode (approx. 2 minutes on start-up}
HIGH
KEY “HIGH” speed activation
LED Flashing: in priming mode (approx. 2 minutes on start-up}
STOP KEY Shutdown of the speed during operation
POWER LED Flashing: pump stopped, powered up
ERROR LED The number of ashes indicates the error in progress “ECO” speed activation
3. Operation
• To prevent against any risk of explosion that may cause material
damage, serious injury or even death, make sure that the hydraulic
circuit is free of any debris or blockage and is not subject to
excessive pressure.
• Never run the pump “dry” as this may damage it.
• The pre- lter strainer cover must be closed by hand {do not use
any tools).

12 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
12 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
• Check that the hydraulic connections are correctly tightened.
• Check that the pump is stable and level.
• The hydraulic circuit must be bled and not contain any foreign bodies.
• The pump pre- lter strainer cover must be correctly closed (by hand}
and its gasket clean and in place.
• Check that the valves are open.
• Start up the pump by activating a speed. The pump always starts in
“priming” mode (2850 rpm for approx. 2 minutes}.
• The pump is self-priming. However, you are strongly recommended to ll
the pre- lter strainer with water before starting it up for the rst time to
facilitate the procedure.
• The pump has a priming capacity up to 3 metres above the
swimming pool water level and at sea level elevation (if the hydraulic
circuit is perfectly sealed).
• Bleed any air present in the ltration circuit using the bleed normally
present on the lter (refer to the swimming pool lter’s manual}.
• Check that there are no leaks on the hydraulic circuit.
4. ADDITIONAL USER FUNCTIONS
SPEED KEYS TO START THE SPEED PRESET SPEED
ECO SPEED ECO 1400 rpm
MED SPEED MED 2150 rpm
HIGH SPEED HIGH 2850 rpm
PRIMING SPEED AUTOMATIC AT START-UP 2850 rpm for 2 minutes
• When the pump is running, it displays the operating speed and an LED
lights up above the key which corresponds to the speed.
4.1 Using speeds
If the mains supply is disconnected (manually or via the
ltration lock) the pump will restart at the last active speed.
4.2 Pump shutdown
• press the STOP button

13
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
MAINTENANCE
13
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
4.3 Pump reset
You may reset the pump to return it to “factory”
conguration:
• make sure that the pump is powered up but stopped (“OFF” is
displayed on the screen).
• press ECO + MED + HIGH for 5 seconds until the 3
corresponding LEDs ash once.
• release the keys: the pump is now reset.
MAINTENANCE
SERVICING
• It is recommended that the appliance undergo general servicing
at least on a yearly basis to ensure proper operation, maintain
performance levels and potentially prevent certain failures. These
operations are carried out at the user’s expense and certain
operations must be performed by a technician.
User maintenance
• Make sure that the pump and electrical compartment contain
no foreign material/objects.
• Clean the outside of the appliance, do not use
solvent-based products.
• Clean the pre- lter strainer, the cover and the gasket regularly.
• Check that the pre- lter strainer is correctly in place,
or it may prevent the cover from closing fully.
Maintenance to be carried out by a qualified technician
• Check the earth connection.
• Check that the electrical cables are correctly tightened and
connected and that the switch box is clean.
• Check that the user interface is correctly connected.
13
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
4.3 Pump reset
You may reset the pump to return it to “factory”
conguration:
• make sure that the pump is powered up but stopped (“OFF” is
displayed on the screen).
• press ECO + MED + HIGH for 5 seconds until the 3
corresponding LEDs ash once.
• release the keys: the pump is now reset.
MAINTENANCE
SERVICING
• It is recommended that the appliance undergo general servicing
at least on a yearly basis to ensure proper operation, maintain
performance levels and potentially prevent certain failures. These
operations are carried out at the user’s expense and certain
operations must be performed by a technician.
User maintenance
• Make sure that the pump and electrical compartment contain
no foreign material/objects.
• Clean the outside of the appliance, do not use
solvent-based products.
• Clean the pre- lter strainer, the cover and the gasket regularly.
• Check that the pre- lter strainer is correctly in place,
or it may prevent the cover from closing fully.
Maintenance to be carried out by a qualified technician
• Check the earth connection.
• Check that the electrical cables are correctly tightened and
connected and that the switch box is clean.
• Check that the user interface is correctly connected.

14 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
TROUBLESHOOTING
14 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
TROUBLESHOOTING
• If a problem occurs, before you contact your retailer, please carry
out these few simple checks using the following tables.
• If the problem continues, contact your retailer.
• Actions to be performed by a qualied technician only
Appliance behaviour
The pump does not
start / the motor does
not turn.
• Filtration outside of a scheduled operating range (“Auto” mode). Check the
ltration clock settings.
• Faulty user interface fuse, replace .
• Electric power cut. Check the circuit breaker(s).
• Check the connection between the power cable and the motor terminals.
• Check that the user interface cable is not damaged.
• The “error” light ashes, see § “5.2 I Error codes”
• Check that the motor shaft rotates freely. Check that there is no debris in the
pre- lter strainer.
• If debris remains, remove the pump to access the turbine.
The pump doesn’t
prime / air can be seen
in the pre- filter strainer.
• Check the position of all valves in the hydraulic circuit.
• Air is stuck in the circuit, drain the hydraulic circuit (drain screw on the lter).
• The pool’s water level is too low, air is being sucked into the circuit, ll the pool.
• The gasket of the pre- lter strainer lid is defective, check the condition of the
gasket and the correct air-tightness of the lid.
Low flow rate/ low filter
pressure
• Pre- lter basked full of debris: clean.
• Air leak in the circuit. Check all tightening torques.
• The turbine and the pump diffuser are blocked or worn, replace.
• The diffuser seal is worn, replace.
Low flow rate/ high
filter pressure
• The lter is clogged. Wash the lter (or the cartridge depending on the case).
• Check the position of all valves in the hydraulic circuit.
Pump making a lot
of noise
• Air leak or cavitation in the suction piping. Check the position of the valves and
adjust where necessary.
• Pump incorrectly positioned on the ground. Check that it is resting in a at
position on a hard, horizontal ground. Use anti-vibration studs where
necessary.
• A foreign body is present in the pre-lter strainer.
• A foreign body is present in the pump body (in this case, the pump must be
removed).
Leak between the pump
body and the motor • The mechanical lining is damaged or defective, replace
The pump heats up and
switches off
• The motor is overheating due to too little ventilation. Check that there is enough
clear space around the motor.
• There is an electrical fault. Check the power connections and check the
mains voltage, which must not vary.
There is no damage to
the user interface
• The cable(s) is(are) damaged or poorly connected in the user interface housing;
check the condition of these cables.

15
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
15
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
Error codes
Software Error Code Matrix
The interface control panel has a digital display and red error
display LED to indicate operation issues. Normal operation is indicated by a
single ftash of this LED upon startup.
Any subsequent blink sequence of this LED indicates that a fault has been
registered by the motor control, with the explanation of these faults given in
the below table. This table also includes the cause for this fault as well as
some potential actions to potentially resolve the issue.
BLINKS/
DISPLAY FAULT SOFTWARE CAUSE ACTION
1/ Er01
Micro
controller
failure
Micro controller is
continually rebooting.
No action can be taken to resolve issue. Return motor
for warranty.
2/ Er02 Under
voltage
The line voltage has
dropped below 180 volts
AC running.
• The controller will reboot after voltage comes above
209 volts AC for at least 6 seconds.
• Reduce distance between motor/pump and breaker.
• Turn off any other non-critical equipment on the same
breaker circuit.
3/ Er03 Temperature
Internal electronics de-
tected an over tempera-
ture condition (+100C
on sensor)
• Verify the proper impeller has been applied
(net 1.0Hp max)
• Turn the power off at the timer / breaker and allow
motor to remain off for at least 15 minutes before
reapplying power.
4/ Er04 Over
current trip
Over current protection
has tripped.
• Verify the proper impeller has been applied
(net 1.0Hp max)
• Inspect all equipment / piping in the system
connected to the pump.
5/ Er05 Over
voltage
The line voltage has risen
above 269 volts AC.
• The power must be turn off for at least 15second
and then reconnect the power. The motor should
run normally.
6/ Er06 Output shaft
seized
Motor failed to start.
Motor was stopped.
• Manually rotate the shaft via the shaft access in the
fan cover
• Inspect all equipment in-line with the pump for
obstructions or locked pump parts.
7/ Er07 Self check
One or more of the self-
tests failed either at start
up or while running.
• Turn the power off at the timer / breaker and allow
motor to remain off for at least 15 minutes before
reapplying power.
• Return motor for warranty if error persists.
8/ Er08 Motor fault
One or more of the
phases has 1 become
disconnected.
• Turn the power off at the timer / breaker and wait
one minute before opening the topside connection
enclosure. Verify phase leads from both the motor
and control connecting into the terminal block (red,
yellow, white leads on left-most connections of
blocks as viewed from the conduit entrance) are
properly connected and screws on the terminal block
are tightened sufciently.
Note: After remove power from motor, please wait 30 seconds before re starting.

16 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
PUMP PARTS
16 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
PUMP
NO COMPONENT
PART NO. DESCRIPTION QTY
1 500-6413 TITAN 2 PUMP LID LOCK RING 1
2a 110-5170 TITAN 2 PUMP UNION COMPLETE 50MM 2
2b 110-5171 TITAN 2 PUMP UNION COMPLETE 63MM 2
3 110-5123 TITAN 2 PUMP UNION O'RING 2
4500-6412 TITAN 2 PUMP LID 1
5 500-6414 TITAN 2 PUMP LID O'RING 1
6 500-6031 TITAN 2 PUMP BASKET 1
7 500-6326 TITAN 2 PUMP DIFFUSER O'RING 1
8 500-6053 TITAN 2 DIFFUSER SCREW M4X25 3
9 500-6322 TITAN 2 PUMP DIFFUSER 1
10 500-6335 TITAN 2 PUMP IMPELLER WITH INSERT 0,75KW 1
11 500-6165 TITAN 2 PUMP SHAFT SEAL 3/4" 1
12 500-6062 TITAN 2 PUMP FLANGE O'RING 1
13 500-6321 TITAN 2 PUMP SEAL PLATE 1
14 500-6325 TITAN 2 FLANGE BOLT SS M6X40 8
15 500-2068 TITAN 2 BARESHAFT MOTOR 1HP 240V 1
16 500-6327 TITAN 2 FLANGE BOLT SS M8X30 4
17 500-6409 TITAN 2 PUMP BODY 1
18 500-6398 TITAN 2 PUMP FOOT PIECE 1
19 500-6213 TITAN 2 WEDGE 1HP 1
$PEFTNBZDIBOHF

17
BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
Fluidra would like to communicate with you in order to provide you, our valued customer, with
up to the minute water-related news - together with our latest products.Please indicate below if
you would like us to keep in touch.
May Fluidra communicate with you?
Preferred method of communication?
Thank you for completing your warranty registration.
To serve you better, Fluidra will send you information on products, current swimming pool
legislations and special oers.
Please tick the appropriate box
Please tick the appropriate box
YES NO
Email SMS Telephone
Please fill out all your details to ensure your warranty is registered.
Name & Surname:
Physical Address:
Landline:
Email:
Product:
Date Installed: Signature:
Store purchased at:
Serial No:
Model:
Date of purchase:
Mobile:

18 BARACUDA | TITAN 2 ECO 3 | Installation & Operating Instructions
Dealer / Store Stamp
Customer Care Telephone: 086 088 7665
customercare@fluidra.co.za
www.baracuda.co.za
This manual suits for next models
1
Table of contents
Popular Swimming Pool Pump manuals by other brands

Gullberg Jansson
Gullberg Jansson GJPACW1V-15 Installation and maintenance guide

Hayward
Hayward TriStar VS Series Technical guide

Doughboy
Doughboy 0-1063-020 owner's guide

Wilo
Wilo Wilo-FilTec FBS Installation and operating instructions

Smartpond
Smartpond PCUV9 manual

Davey
Davey Silensor SLS100 Installation and operating instructions