Oasis Aquatics V Series User manual

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 1
INSTALLATION AND OPERATION MANUAL
V SERIES Variable 3 Speed Pool & Spa Pump
V SERIES
V310 | V390| V480
Head Office
62 Parkhurst Drive
Knoxfield VIC 3180
T: 03 9887 2131
New South Wales
Unit 1, 20-22 Foundry Road
Seven Hills NSW 2147
T: 02 9838 0000
Queensland
Unit 4, 8 Reichert Drive
Molendinar QLD 4214
T: 07 5679 6821
info@oasisaquatics.com.au
oasisaquatics.com.au

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 2
PLEASE READ
THESE
INSTRUCTIONS
BEFORE
OPERATING.
Please pass these instructions on to the
owner of this equipment.
V310 (1.25HP) V390 (1.75HP) V480 (2.25 HP)
DANGER - HAZARDOUS SUCTION!
•Do not block water entry into filtration system with any part of your body as the suction can trap hair
or body parts, causing severe injury or death. Do not block suction. Turn off pump immediately if
someone becomes trapped.

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 3
CAREFUL REMINDER
•This appliance is not intended for use by persons (including children) or person/s with reduced
physical, sensory or mental incapability’s, or lack of experience and knowledge, unless they have
supervision or instruction concerning use of the appliance by a person responsible for their safety.
•Please check your pump basket, skimmer and entire pool system regularly to maximize the life of
your pool equipment & personal safety. Turn pump off first before checking baskets.
•Make sure that all pressure gauges installed are in working condition and the operating pressure is
within limits as specified on the product.
•Make sure that each suction inlet, and main drain has a cover that is securely attached and in safe
working condition to meet with all current legislation.
•Make sure that all skimmer covers (deck lids) are securely attached and in safe working condition.
These should be replaced every 3 to 4 years.
•Remove any obstructions or debris from the main drain cover.
•Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at
regularly.
•Remove obstructions and combustibles from around the pump motor.
•Make sure all wiring connections are clean and that all wiring and electrical equipment is in good
condition. Damaged wiring must be repaired or replaced by a qualified electrician as soon as
damage is discovered.
•Do not add chemicals directly to the pool skimmer. Adding undiluted chemicals may damage pump,
heater, etc and void warranty.
•Check water balance and sanitizer levels at your local pool shop.
WARNING!
CHILDREN SHOULD BE SUPERVISED AT ALL TIMES TO ENSURE THAT DO NOT PLAY WITH
THE PUMP OR ANY POOL ASSOCIATED ELECTRICAL DEVICE
•Pump suction is hazardous and can cause entrapment, drowning or disembowel bathers.
•Do not block or cover any pool/spa suction.
•Do not use or operate swimming pools, spas or spa baths if a suction cover is broken, missing or
loose.
•Suction covers and inlets must be installed as per Australian Standards guideline and provided for
every pump to avoid suction entrapment.
CAUTION!
•In the interest of safety, we advise that all brands and types of pool pumps must be installed in
accordance with AS3000 wiring rules or equivalent
•If the pump and filter are located below pool water level, it is necessary to fit isolating valves in the
pipe between the pump and the skimmer box and in the return pipe from the filter to the pool.
•The fittings on this product are constructed of ABS. Some PVC jointing compounds are incompatible
with ABS. Check compound suitability before use.
•OASIS recommends that all installations are fitted with earth leakage or residual current protection
devices.
•Ensure that an electrical isolation switch is located with easy access so that the pump can be
switched off in an emergency.

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 4
The V Series pool pump uses a patented variable 3 speed
permanent magnet brushless DC motor. If installed (by a
professional) and used correctly it will significantly
reduce operating costs, noise and greenhouse emissions.
INSTALLATION & OPERATING INSTRUCTIONS
OASIS’S V SERIES PUMPS
Congratulations on your purchase of a quality product from the OASIS range of Pool and Spa
Equipment. You will be pleased with the many years of reliable and efficient performance your
OASIS pool and spa pump will deliver.
OASIS pool and spa pumps have been designed to circulate swimming pool and spa water in
conditions set out in the Australian Standard for swimming pool water quality (AS 3633)
OASIS designs its own electric motors specifically for its pumps. The matched motor and “pump
wetend” are designed to provide quiet operation and energy efficiency.
OASIS’S totally enclosed fan-cooled motor incorporates “thermal cut-out” overload protection
designed to protect the motor from overheating.
Every OASIS pool and spa pump is thoroughly water tested against flow, pressure, voltage, current
and mechanical performance parameters. OASIS’S advanced pump technology provides reliable and
efficient performance that lasts.
OASIS pool and spa pump are designed with high flow and the head pressures are ideally suited for
the modern pool or spa with extensive equipment.
OASIS pool and spa pumps are designed to operate with most chlorinators, heaters and other pool
equipment producing correct water flow and energy efficiency.
FEATURES & BENEFITS
•Energy Efficient fully variable 3 Speed Motor
•Computer-designed impeller and diffuser quickly correct loss of water flow, allowing a free
flow of water with whisper quiet and efficient performance.
•Easy to remove; see through strainer lid for easy removal of leaves and debris.
•Extra large strainer basket allows long intervals between cleaning.
•Continuous duty rated motor with an enclosed fan cooled motor.
•Built-in thermal overload protects the motor against damage from overheating.
•Every unit is pressure and performance tested in factory ensuring quality and reliability.
•High performance Silicon Carbide mechanical seal, fitted for long life in salt & fresh water.
•Constructed of strong corrosion and U.V. resistant materials for long life.
•A.B.S. quick connect couplings makes installation simple.

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 5
DIMENSIONS
INSTALLATION INSTRUCTIONS
Location
The pump should be located as close to the water as practicable and mounted on a firm base in
a well drained position, high enough to prevent any flooding. It is the installer’s/owners
responsibility to locate the pump so that it can be accessed for service and maintenance. The
rear fan shroud should be installed at a minimum distance of 100 mm away from any walls or
obstructions. This is to allow adequate air flow from the fan to cool the motor. Overheating due
to a lack of cooling voids warranty.
WEATHER PROTECTION
It is recommended that the pump be protected from the weather.
Enclosures should be ventilated to allow a free flow of air for the fan cooled motor.
POWER CONNECTION
OASIS pool and spa pumps are suitable for connection to a nominal 240-volt 50Hz power supply.
The motor is equipped with a flex and 3-pin plug. If a power outlet is not available within 2 meters of
the pump, a 3-pin power point in a safe, dry place may need to be provided by an electrician.
Note:
•Pumps must be either
oSupplied by an isolating transformer, or
oSupplied through a residual current device (RCD) with a rated residual operating current
not exceeding 30mA.
•Extension cords are unsafe around pools and must be avoided.
•If the supply cord of this product is damaged the dealer or manufacturer must replace it,
with genuine OASIS pool and spa pump spares.
•Water temperature is not to exceed 45 degrees
V310 @ 670
V390 @ 700

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 6
PIPE CONNECTION
A barrel union is provided for connecting to the piping from the pool.
The pumps are designed to accept the following PVC Pipes:
•Inlet PVC Position 40mm pipe ID or 50mm fitting ID PVC pressure pipe fittings
•Outlet PVC Position 40mm pipe ID or 50mm fitting ID PVC pressure pipe fittings
The use of pipe with a smaller ID than those specified above is not recommended and may cause
damage to the pump voiding warranty.
A straight length of pipe measuring no less than 300mm should be installed in front of the inlet of
the pump allowing quieter and smoother operation.
Suction piping should be free from all air leaks and any humps and hollows, which may cause
suction difficulties.
The outlet piping from the pump should be connected to the inlet connection on the swimming pool
filter (at the filter valve).
For pump installations above water level, it generally requires a check valve in the suction line.
Do not use type ‘P’ (green) plumber’s glue on the barrel unions as this may cause damage to the
material used.
Always install pump for maintenance and service accessibility.
USAGE WARNING
•The V SERIES is manufactured with technological advances including PCB’s and microchips. It
is necessary to turn power off completely for 10 seconds prior to turning pump back on again
•Some brands of older style chlorinators may release a small amount of power to the even
whilst it seems turned off. It this occurs the PUMP may not reset correctly until power is
completely disconnected.
•In some cases, chlorinator manufacturers may be able to modify internal components so as to
work in with the V310. If not a suitable chlorinator may be required.
•Oasis’s CX chlorinator completely disconnects power to the pump when the pump is in off
mode.

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 7
OPERATION
STARTING THE PUMP
To operate efficiently and to prevent damage to the pump there must be a free flow of water to
and from the pump. Before starting ensure that:
•All pipe work is correctly sealed.
•Barrel unions on the inlet and outlet are hand tightened and the pipework is installed
square to the pump.
•The pool/spa water level is at the correct height.
•That all appropriate valves are open and there is nothing preventing the flow of water
through the system.
1. First prime the pump by removing the strainer basket lid and filling the strainer basket area
with water. Replace the lid, ensuring that it seals on the large o-ring.
2. Connect to the power supply and switch on.
3. Allow the pump to run, so that any air trapped in the pipe work and pump may be expelled.
4. If prime is not established within approximately two minutes, as evidenced by a strong flow of
water from the outlet, switch off the pump for 10 secs and repeat the procedure. Continued
evidence of air under the hair and lint pot lid indicates an air leak in the suction piping work,
which should be rectified to avoid pump damage.
5. If water flow through the pump is continuously tedious to obtain at start-up after cleaning the
lint basket, then an examination of the system to establish a reason and correct the cause.
(ie. Check valve, air leaks, faulty seal/s, crack lid.
V SERIES VARIABLE SPEED CONTROL
V Series

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 8
FACTORY SETTING SPEEDS / STAR RATINGS
V310 @ 7 Star
Low @ 1600 Medium @ 2400 High @ 2850
V390 @ 7 Star
Low @ 1450 Medium @ 2400 High @ 2850
V480 @ 8 Star
Low @ 1320 Medium @ 2400 High @ 2850
ADJUSTABLE SPEED MODE

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 9
V310 VARIABLE 3 SPEED OPERATION
The V SERIES PUMP has 3 speed settings.
1. Eco (Energy Saving)
•This should be used for everyday water filtration
•The pump should be operated for approximately 8 hours per day depending on the
surrounding climate, bather loads, pool volume and length of pipework.
•In some cases when your pool has areas where water is not turning over, increase the
speed setting
•This setting is not recommend to be used with a suction cleaner but may work.
2. Med
•This should be used for gentle spa jet action and the majority of suction cleaners when
connected to a skimmer box
3. High
•This should be used for backwashing, manual vacuuming of the pool, operating gentle or
soft spa jets and/or water features.
PLEASE NOTE
•The V SERIES PUMP will always run at “high” speed for 5 minutes upon start up or a filter
cycle. This assists with priming of the pump and pipe work.
•After the initial 5 minutes the PUMP will revert back to the previous selected speed it was
set at before it was turned off.
•Priming function can be disable, however, this is not recommended

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 10
V390 and V480 VARIABLE 3 SPEED OPERATION
The V SERIES V390 has 3 speed settings
1. Eco (Energy Saving)
•This should be used for everyday water filtration
•The pump should be operated for approximately 8 hours per day depending on the
surrounding climate, bather loads, pool volume and length of pipework.
•In some cases when your pool has areas where water is not turning over, increase the
speed setting
•This setting is may be used with a suction cleaner, however, speed may need to be
increased.
2. Med
•This should be used for gentle spa jet action and for suction cleaners when connected to
a skimmer box
3. High
•This should be used for backwashing, manual vacuuming of the pool, spa jets, infloor
cleaning and/or water features.
PLEASE NOTE
•The V SERIES V390 will always run at “high” speed for 5 minutes upon start up or a filter
cycle. This assists with priming of the pump and pipe work.
•After the initial 5 minutes the V390 PRO will revert back to the previous selected speed it
was set at before it was turned off.
•Priming function can be disable, however, this is not recommended
OASIS’S RECOMMENDATION
•During day-to-day operation we recommend to run the PUMP on “eco” for 8 hours. This
will achieve the lowest noise and lowest operating costs.
•In some cases (larger pools, warmer climates and increase bather loads you may have to
increase the speed setting or operating duration. This will still provide you with significant
savings.
LIMITS
Water temperature Max 45oC Ambient Temperature Max 55oC DBa @ 1 meter 62

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 11
WATER QUALITY
Maintaining balanced water chemistry is important to the life of your pool pump.
This pump is designed to be used with Pool & Spa water, balanced in accordance with Langlier
Saturation Index, with a pH level of between 7.2 and 7.8 and is regularly treated with a chlorine
sanitizing agent with the level not exceeding recommended chlorine levels.
Please consult your local pool shop regularly to have your water tested.
EMPTYING THE HAIR AND LINT POT
The hair and lint pot strainer basket should be inspected frequently through the transparent lid and
emptied when a build up of rubbish is evident.
Follow the directions below.
1. Switch off pump.
2. Unscrew the hair and lint pot strainer basket lid anti-clockwise and remove.
3. Remove the hair and lint pot strainer basket by lifting upwards from its housing.
4. Empty the trapped refuse from the basket. Hose out with water if necessary.
5. Check the hair and lint pot strainer basket for cracks, replace the strainer basket in the
pump if OK.
6. Replace the lid and ensure that it seals on the large rubber o-ring. Firm hand tightness only
is required.
The o-ring & thread can be lubricated with silicone grease.
HOW TO CONNECT TO SUCTION CLEANERS
•It is important that the PUMP is fully primed when connected to a suction cleaner.
•Switch pump to “high” setting for 2 minutes if pump is currently switched on, or allow for
initial 5 minute prime.
•Connect cleaner hose to skimmer plate only after air has been purged from top of hair and
lint pot
•Select speed (usually “med”) at which the cleaner will travel to all areas of the pool
•Disconnect cleaner and remove from pool once it is cleaned. Change setting back (usually
“eco”) to your daily filtration requirements.

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 12
TROUBLE SHOOTING
If the pump does not operate, one of the following conditions may apply:
A. The power is not connected. For 240 volt only.
B. Check the power point by plugging in a portable appliance to ensure power is available.
C. Check fuses and the main power supply switch
D. Automatic overload is tripped. The pump has an in-built thermal overload, which will re-set
automatically after the motor has cooled following an overheating period. Determine the
cause of the overload tripping and rectify.
E. Pump needs to be disconnect for 10 secs and reconnected
F. Blockage is preventing the pump from rotating.
G. If plugged into chlorinator, disconnect and reconnect directly to power after 10 secs. If it
then works, please check your chlorinator manual.
H. Motor is burnt out - burning smell is evident. Replacement is required.
I. If you are unable to resolve any installation or operation difficulties with your OASIS pool
and spa pump, contact the supplier from whom the pump was purchased or you’re nearest
Authorized OASIS pool and spa pump Pool Equipment Service Centre. If any further
assistance is required, contact the OASIS Customer Service Centre at the address indicated
in this manual.
If the pump runs but there is no water flow or water flow is reduced, the following
condition may apply:
1. The filter requires backwashing or it is blocked.
2. Disconnect the suction cleaner
3. Check the skimmer box for blockage.
4. The pump is not primed, increase speed. If this doesn’t work within 1 minute turn off. (See
‘Starting the pump’)
5. There are air leaks in the suction piping. Check all piping and eliminate leaks, also check for
a loose strainer basket lid. Air bubbles in the water flowing back to the pool would indicate
a leak in the suction to the pump allowing air to infiltrate the pipe work.
6. The pump is not able to get water from the pool. Check that the valves to the pump are
fully open and that the pool water level is up to the skimmer box.
7. A leaking pump seal may also prevent operating. Evidence of this would be water on the
ground under the pump.
8. Blockage in the piping or pump. Remove the hair and lint pot strainer basket and check for
any blockage to the pump impeller entry.
9. You may require a check valve installed.
Removal of the Pump from Pipe work
1. To remove the pump, follow these instructions:
2. Switch off the power and remove the plug from the power source.
3. Close the water valves on the pool return and the pump inlet pipe work.
4. Remove the discharge & suction barrel unions taking care not to lose the o-rings.
5. Move the pipe work with the barrel unions attached until the pump can be moved clear.

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 13
FAULT CODES
Blinks
Fault
Cause
1
Micro Controller Failure
Micro Controller is continually rebooting
2
Mains Under Voltage
The mains voltage has dropped below 180 volts AC running.
NOTE: If this fault is active the controller will reboot after
voltage comes above 209 volts AC for at least 6
3
Temperature
Over Temperature (100 degrees Celsius)
Under Temperature (-20 degrees Celsius)
Under abnormally high ambient operating conditions the
controller reduces the motor speed gradually in 10 rpm
increments to maintain the devices temperatures within limits.
If the speed drops to below 2410 rpm the controller shuts the
motor down and display the fault code
4
Over Current Trip
Over current protection has tripped
The speed of the motor will be adjusted down automatically
when the overload condition occurs to protect the devices. The
controller will only display this fault code when it has been
damaged.
5
Mains Over Voltage
The Mains voltage has risen above 269 volts AC
6
Output Shaft Seized
Motor failed to start
Motor was stopped
7
Self-Check
One or more of the self-tests failed at start up or while running
8
Motor Fault
One or more of the phases has become disconnected
10
Other Fault
Any fault not covered by other codes
Presently no faults should trigger this
none
EEPROM Load Failure
Checksum failed while loading EEPROM to memory
PLEASE NOTE
•If the pump is hard wired, a qualified electrician should remove the wiring.
•Barrel unions need to be hand tightened. No sealant, glues or silicones are required.
•When making any enquiries about your OASIS pool and spa pump be certain to quote the
model number from the nameplate located on motor.
•Never run pump dry. Running the pump with no water may damage the mechanical seals,
causing leakage and flooding. Dry running damage and associated damage is not covered
under warranty.
•Failure to undertake regular maintenance may cause damage not covered by warranty.
•The pump is not intended for use by young children or infirm persons without supervision.
Ensure that young children are supervised at all times to ensure that they do not play with
the pump.

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 14
COMMERCIAL INSTALLATIONS
On Commercial Installations, such as health clubs, swim schools, motels/hotels and hydrotherapy,
parts and in field labour warranty (within capital city metropolitan areas or 20km radius of
authorised service agents) is 6 months from the date of purchase.
Oasis assumes no liability for consequential damages of any kind.
PLEASE NOTE
This literature is not a complete guide to product usage. Further information is available from your
OASIS dealer, OASIS Customer Service Centre and from the relevant product Installation and
Operating Instructions.
•This data sheet must be read in conjunction with the relevant product Installation and
Operating Instructions and all applicable statutory requirements. Product specifications
may change without notice.
•Warranties vary in different States and/or Territories.
COMMENTS / NOTES

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 15
LIMITED WARRANTY
Your Oasis V SERIES V310 / V390 PRO pool and spa pump is covered by a limited three-year
warranty.
Please refer below for details as follows:
•3 year limited warranty against defects in workmanship and materials excluding obvious
neglect, misuse, improper installation or improper maintenance from date of purchase.
•3 years on pump body and seal plate
•2 years on motor
Replacement of routine maintenance items are not covered under warranty. These items may
include O’ rings, gaskets and mechanical seal.
This warranty is subject to the conditions and limitations herein after stated. You must notify Oasis
of the failure of any component of your pool and spa pump and motor within 7 days of the
recognised fault. Oasis will at its option, repair or replace any defective parts. Component failure
must be due solely to a defect in materials or workmanship. This warranty does not apply if failure
is due to any abuse, misuse, improper installation or accident or to any of the following:
•Improper chemical balance in the water,
•Incorrect power supply and/or connection
•Water damage from external sources,
•Cement, pebbles, render or other pool surface finish blocking the impeller,
•Use on non swimming pool or spa pool application, (salt water aquaculture).
•Running the pool and spa pump dry,
•Inadequate ventilation,
•Installed on uneven ground or in a sump area that collects significant water
•Addition of salt, chlorine and/or any other pool chemicals through skimmer or pump
basket
To stand behind our commitment to provide warranty coverage, Oasis has established a network of
authorized warranty agents throughout Australia. To obtain warranty service, contact our Service
Department. If your request for warranty service is diagnosed to be non-warrantable, you will still
be charged for a service call.
12 month in field labour warranty is applicable in some Capital City Metropolitan areas or within a
20 km radius of an Authorised Oasis Service Agent. A travel fee may be charged on all other areas.
Oasis shall have no liability for incidental or consequential damages. No person is authorized to
make any representation or warranty on behalf of Oasis other than what is stated here.
CUSTOMER RECORD (To be retained by the customer)
DEALER / INSTALLER NAME
SERIAL NUMBER
DATE INSTALLED

V SERIES V310 | V390 | V480 VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
info@oasisaquatics.com.au
oasisaquatics.com.au 16
A part of the
group
Victoria
62 Parkhurst Drive
Knoxfield VIC 3180
Australia
T: 03 9887 2131
New South Wales
Unit 1, 20-22 Foundry Road
Seven Hills NSW 2147
Australia
T: 02 9838 0000
Queensland
Unit 4, 8 Reichert Drive
Molendinar QLD 4214
Australia
T: 07 5679 6821
This manual suits for next models
3
Table of contents
Other Oasis Aquatics Swimming Pool Pump manuals