Do not block the intake or heat dissipation openings and vents and
place the appliance beneath an extractor hood whose system must be
legally compliant�
It is good practice to have the periodic maintenance of the ovens
performed every year by an authorised technician and in compliance
with the specic regulations. On this occasion all controls regarding the
operation of electric components (selectors, electronics, solenoid valves,
heating elements, motors, cooling fans, etc�) and the mechanical controls
relative to functionality of the doors, hinges, closing mechanisms, and
gaskets will be performed�
1.3 Electric connection
As prescribed, the electrical system must have an efcient earth
system, as required by the regulations in force� The electrical safety of
the appliance can only be ensured when the electrical system is conform�
Before making the electrical connection, check the mains voltage and
frequency values to ensure that they conform to the requirements of the
appliance, as indicated on its data plate�
For direct connection to the mains, a device, sized according to the
load, must be placed between the appliance and the mains itself, which
ensures disconnection� Its contacts should have a minimum opening
distance that enables complete disconnection under the conditions of
category III overvoltage, according to installation rules; this device
should also be located so that it can be easily used by the operator at
any time�
Turn the master selector, to which the power supply plug will be
connected, to position 0 (zero)� Have the socket cable section checked
by qualied staff to make sure it suits the power absorbed by the device.
The power supply cable to be used must be type H05 RN F and it must
be the proper size for the appliance�
The connection terminal board is inside the case, at the top�
Pass the cable through the cable gland, connect the wires to the
corresponding terminal of the terminal board and x them.
The earth wire must be longer than the others so that, if the cable
holder breaks, the earth cable detaches after the voltage cables.