Stopping Irrigation at a Specific Temperature Reading
Baseline Support: 866-294-5847 2 www.baselinesystems.com
When the controller finds the device, the serial number displays in the Action column.
6. Press the
or
button to highlight the serial number of the air temperature sensor in the Action
column.
7. Press the
button to move to the Temp. Sensor column.
8. Press the
or
button to highlight slot number 1 in the list.
9. Press the OK button. The serial number of the air temperature sensor that you selected in the
Action column now displays next to the number 1 in the Temp. Sensor column.
Step 3 – Setting Up the Air Temperature Sensor in the Controller
After you assign an air temperature sensor in the BaseStation 1000 system, the device is automatically
enabled. You can disable the air temperature sensor if you want to take it out of service temporarily,
and then you can enable it again when necessary.
1. Press the Search & Assign button. The Search & Assign menu displays.
2. Press the
or
button to highlight the Temperature Sensor option, and then press the OK button
to select it. The Temperature Sensor screen displays.
3. Press the
or
button to highlight the Device Setup option, and then press the OK button. The
Temp. Device Setup screen displays.
4. Press the
or
button to highlight the switch device number in the left column, and then press
the
button to move to the Enabled field.
If the device is currently enabled, a checkmark displays in the Enabled field. Press the +or –
button to remove the checkmark.
If the device is currently disabled, there is no checkmark in the Enabled field. Press the +or –
button to replace the checkmark.
Step 4 – Programming the Controller
In the BaseStation 1000, you need to set up a stop condition that will cause a running program to stop
when the air temperature sensor reading meets the condition.
1. Press the Program Setup button. The Program Setup menu displays.
2. If the program that you want to modify displays in the upper-left corner of the screen, continue to
step 3. Otherwise, press the PRG button until the program that you want to modify displays in the
upper-left corner of the screen. If the BaseStation 1000 has multiple programs, you will need to
assign the stop condition to each program in order to stop all watering at the site.
Note: To move backwards in the list of programs, press and hold the PRG button, and then press the
– button repeatedly.