Bauer CENTERSTAR 9000 133 EL User manual

OPERATING MANUAL
for
BAUER CENTERSTAR 9000
133 EL, 168 EL, 168 E, 203 EL, 203 E, 219 EL, 219 E
Version: VI / 2015
850 9979

II Operating Manual for BAUER CENTERSTAR 9000
Introduction
Thank you for buying BAUER CENTERSTAR 9000 !
The present manual is a very important document that describes how to operate and service BAUER
CENTERSTAR 9000.
This manual describes the system as detailed as possible. If you need still more information, please contact your
dealer or turn directly to BAUER in Voitsberg.
Please note that the content of this manual neither constitutes part of nor alters in any way any previous or
existing agreement, promise or legal relationship. BAUER’s commitment is based solely on the respective
purchase contract which also contains the complete and only valid warranty agreement. Said contractual warranty
is neither extended nor limited by the content of this manual.
All information contained in the present manual is based on the latest product details available at the time of
printing.
BAUER reserves the right to change without notice without assuming any liability!
BAUER CENTERSTAR 9000 is designed for highest performance safety and reliability provided it is operated in
accordance with the present operating instructions.
Therefore you should study this manual thoroughly before starting your BAUER CENTERSTAR 9000 !
Strictly observe all instructions pertaining to system handling, operation and service!
On this condition, BAUER CENTERSTAR 9000 will operate to your satisfaction for many years!
Non-observance of this manual may cause personal injury or damage the equipment!
Please make this manual available to your staff. State the pump type and serial number of your
BAUER CENTERSTAR 9000 in all inquiries, correspondence, warranty problems, or parts orders.
We wish you a lot of success with BAUER CENTERSTAR 9000 !
This manual is to be considered an integral part of BAUER CENTERSTAR 9000. Suppliers of both new and used
systems are advised to put down in writing that they delivered the manual together with the system.

Operating Manual for BAUER CENTERSTAR 9000
III
Owner of the machine
This machine with the serial number
Belongs to
Name
Address
Residence
Telephone number
Dealer
Bauer dealer
Service – technician
Telephone number

IV Operating Manual for BAUER CENTERSTAR 9000
Handing over record
A duly test run has been done in the presence of the client or a nominated agent of the client.
The client confirms by signing that the machine has been test run before taken over. A copy of
the handing over record needs to be sent back to the company BAUER GMBH.
Comments:
For the client For the company BAUER GMBH
______________________________ ______________________________

Operating Manual for BAUER CENTERSTAR 9000
V
Product details
Date of delivery .......................................................................................
Date of initial operation .......................................................................................
Type BAUER CENTERSTAR 9000 ...................................................................
Serial number .............................................................................................................................
Central tower fixed ......................................... towable .............................
Configuration of span ........................................................................................................................
Spans fixed ........................................ towable ...........................
Booster pump yes ............................................ no .....................................
End rain gun yes ............................................ no .....................................
Equipment ..........................................................................................................
Comments ..........................................................................................................
..........................................................................................................
..........................................................................................................
..........................................................................................................
Producer of the machine: Röhren- und Pumpenwerk BAUER GmbH
Kowaldstrasse 2
A – 8570 Voitsberg
Tel.: +43 3142 200 – 0
Fax: +43 3142 200–320 / -340
www.bauer-at.com
Dealer: Name: ………………………………………………………………….
Address: ………………………………………………………………….
………………………………………………………………….
Tel. / Fax: ………………………………………………………………….

VI Operating Manual for BAUER CENTERSTAR 9000
Index
1GENERAL INSTRUCTIONS............................................................................................................................. 1
2WARNING SYMBOLS ...................................................................................................................................... 2
3GENERAL ......................................................................................................................................................... 4
4GENERAL INSTRUCTIONS FOR SAFETY AND ACCIDENT PREVENTION................................................ 4
5SAFETY PRECAUTIONS FOR CENTERSTAR 9000...................................................................................... 5
5.1GROUNDING............................................................................................................................................. 5
5.2ELECTRICAL SYSTEM............................................................................................................................. 5
5.3MECHANICAL SYSTEM............................................................................................................................ 5
6.TECHNICAL DESCRIPTION ............................................................................................................................ 6
7CONTROL UNITS............................................................................................................................................. 8
7.1CONTROL UNIT UNIVERSAL.................................................................................................................. 8
7.1.1STANDARD BUILT-IN COMPONENTS.....................................................................................................8
7.2CONTROL UNIT UNIVERSAL PRO........................................................................................................ 11
7.2.1STANDARD BUILT-IN COMPONENTS...................................................................................................12
7.3CONTROL UNIT UNIVERSAL PRO - G.................................................................................................. 14
7.3.1STANDARD BUILT-IN COMPONENTS...................................................................................................15
7.4TOWER BOX........................................................................................................................................... 17
7.4.1MICROSWITCH ADJUSTMENT ...............................................................................................................17
7.5TERMS..................................................................................................................................................... 18
7.6ALIGNMENT OF TOWERS AFTER INSTALLATION.............................................................................. 19
7.6.1ALIGNMENT OF TOWERS WITHOUT TOWER ALIGNMENT SWITCH ............................................19
7.6.2ALIGNMENT OF TOWERS WITH TOWER ALIGNMENT SWITCH ....................................................20
7.6.3TOWERBOX ADJUSTMENT.....................................................................................................................21
7.7ALIGNMENT CHECK-UP........................................................................................................................ 22
7.7.1ALIGNMENT OF THE SYSTEM – CONTROL UNIT UNIVERSAL.......................................................24
7.7.2ALIGNMENT OF THE SYSTEM – CONTROL UNIT UNIVERSAL PRO ..............................................25
7.7.3ALIGNMENT OF THE SYSTEM – CONTROL UNIT UNIVERSAL PRO - G........................................27
7.7.4INSTRUCTIONS FOR DETERMINING TRACKS....................................................................................27
8INITIAL START-UP......................................................................................................................................... 27
8.1START PROCEDURE WITH CONTROL UNIT UNIVERSAL................................................................. 29
8.2SHUT-OFF PROCEDURE WITH CONTROL UNIT UNIVERSAL........................................................... 30
8.3START PROCEDURE WITH CONTROL UNIT UNIVERSAL PRO ........................................................ 30
8.4SHUT-OFF PROCEDURE WITH CONTROL UNIT UNIVERSAL PRO.................................................. 31
8.5START PROCEDURE WITH CONTROL UNIT UNIVERSAL PRO-G .................................................... 32
8.6SHUT-OFF PROCEDURE WITH CONTROL UNIT UNIVERSAL PRO-G.............................................. 32
8.7EMERGENCY MODE.............................................................................................................................. 33
8.7.1Start procedure ..............................................................................................................................................33
8.7.2Shut-off procedure.........................................................................................................................................34
9MAINTENANCE INSTRUCTIONS.................................................................................................................. 35
9.1SERVICE INTERVALS............................................................................................................................ 35
9.2SERVICE PLAN....................................................................................................................................... 36
9.2.1Post-season maintenance...............................................................................................................................37
9.2.2Pre-season maintenance ................................................................................................................................37
9.2.3Pretensioning forces and tightening values of bolts......................................................................................38
10TROUBLESHOOTING.................................................................................................................................... 39
10.1RESTART AFTER DOGLEGGING – WITH TOWER ALIGNMENT SWITCH......................................... 40
10.1.1CONTROL UNIT UNIVERSAL..............................................................................................................40
10.1.2CONTROL UNIT UNIVERSAL PRO .....................................................................................................41
10.1.3CONTROL UNIT UNIVERSAL PRO-G.................................................................................................43
10.2RESTART AFTER DOGLEGGING – WITHOUT TOWER ALIGNMENT SWITCH................................. 43
10.2.1CONTROL UNIT UNIVERSAL..............................................................................................................43
10.2.2CONTROL UNIT UNIVERSAL PRO .....................................................................................................45
10.2.3CONTROL UNIT UNIVERSAL PRO-G.................................................................................................46
11TECHNICAL DATA......................................................................................................................................... 47
11.1DIMENSIONS OF BAUER CENTERSTAR 9000 - 168/203 EL .............................................................. 47
11.2DIMENSIONS OF BAUER CENTERSTAR 9000 - 133 EL ..................................................................... 49

Operating Manual for BAUER CENTERSTAR 9000
VII
11.3GEARBOX AND DRIVE MOTORS..........................................................................................................50
11.3.1Gearbox......................................................................................................................................................50
11.3.2Drive motor................................................................................................................................................51
12OPTIONAL FEATURES..................................................................................................................................52
12.1AUTOMATIC CIRCLE STOP...................................................................................................................52
12.2SECTOR CONTROL WITH AUTOMATIC REVERSE – AUTOMATIC SECTOR STOP ........................52
12.3END STOP - AUTOMATIC REVERSE....................................................................................................53
12.4LOW-PRESSURE SHUT-OFF.................................................................................................................53
12.5AUTOMATIC PUMP UNIT SHUT-OFF....................................................................................................54
12.6AUTOMATIC ELECTRIC SHUT-OFF VALVE CONTROL.......................................................................54
12.7ENDGUN WITH BOOSTER PUMP .........................................................................................................54
12.8SECTOR CONTROL FOR ENDGUN ......................................................................................................55
12.9RUNNING CONTROL..............................................................................................................................55
12.10TOWER ALIGNMENT SWITCH...............................................................................................................55
12.11RUNNING LIGHT.....................................................................................................................................55
13REPOSITIONING OF CENTERSTAR.............................................................................................................55
13.1TOWING THE CENTERSTAR ON THE PIVOT SIDE.............................................................................56
13.1.1Turning the tower wheels...........................................................................................................................56
13.1.2Mounting the tow cable on pivot with skids..............................................................................................57
13.1.3Mounting the tow cables on 4-wheel pivot................................................................................................58
13.2TOWING THE CENTERSTAR ON THE END TOWER...........................................................................59
13.2.1Turning the tower wheels...........................................................................................................................59
13.2.2Bracing the end tower................................................................................................................................60
13.2.3Bracing the 4-wheel pivot..........................................................................................................................60
14ELECTRICAL WIRING DIAGRAMS...............................................................................................................61
14.1PIVOT PANELS .......................................................................................................................................62
14.1.1Pivot panel UNIVERSAL - infeed.............................................................................................................62
14.1.2Pivot panel UNIVERSAL – control...........................................................................................................63
14.1.3Pivot panel UNIVERSAL– wiring diagram ..............................................................................................64
14.1.4Pivot panel Universal with autoreverse – infeed........................................................................................65
14.1.5Pivot panel Universal with autoreverse - control......................................................................................66
14.1.6Pivot panel Universal with autoreverse – wiring diagram.........................................................................67
14.1.7Pivot panel Universal PRO - infeed...........................................................................................................68
14.1.8Pivot panel Universal PRO – control.........................................................................................................69
14.1.9Pivot panel Universal PRO – wiring diagram............................................................................................71
14.1.10Pivot panel Universal PRO with autoreverse - infeed................................................................................72
14.1.11Pivot panel Universal PRO with autoreverse - control ..............................................................................73
14.1.12Pivot panel Universal PRO with autoreverse – wiring diagram.................................................................75
14.1.13Pivot panel Universal PRO-G - infeed.......................................................................................................76
14.1.14Pivot panel Universal PRO-G - control .....................................................................................................77
14.1.15Pivot panel Universal PRO-G – wiring diagram........................................................................................79
14.1.16Pivot panel Universal PRO-G – wiring diagram........................................................................................80
14.2BOOSTER PUMP FOR ENDGUN...........................................................................................................81
14.3TOWER BOX ...........................................................................................................................................82
14.3.1Tower box standard....................................................................................................................................82
14.3.2Tower box with tower alignment switch....................................................................................................83
14.3.3Tower box with running control ................................................................................................................84
14.3.4Tower box with tower alignment switch and running control ...................................................................85
14.3.5End control standard..................................................................................................................................86
14.3.6End control with tower alignment switch ..................................................................................................87
14.3.7End control standard with limit stop..........................................................................................................88
14.3.8End control with limit stop and tower alignment switch............................................................................89
14.3.9End control standard with limit stop and autoreverse................................................................................90
14.3.10End control with tower alignment switch, limit stop and autoreverse.......................................................91
14.3.11End control PRO-G with tower alignment switch .....................................................................................92
14.3.12End control PRO-G standard .....................................................................................................................93
15SERVICE PROOF ...........................................................................................................................................94
16CONFORMITY CERTIFICATE........................................................................................................................98

VIII Operating Manual for BAUER CENTERSTAR 9000

Operating Manual for BAUER CENTERSTAR 9000
1
1 GENERAL INSTRUCTIONS
CE SYMBOL
The CE symbol that has to be affixed on the machine by the manufacturer outwardly
demonstrates compliance of the machine with the directives for machines and other relevant EU
directives.
EC Declaration of conformity (see Annex)
This “Warning” symbol refers to important safety instructions in this manual.
Whenever you see this symbol be aware of possible injury hazards. Read the note
following the symbol very carefully and inform the other operators accordingly.
Non-observance of this instruction may damage or destroy the machine or individual
components.
It is very important to observe this note or instruction carefully!
Qualified operators
These are persons who on behalf of their training, experience and instruction as well as their knowledge of
relevant standards, rules, precautions to be taken for accident prevention, and prevailing operating conditions,
have been authorised by the person in charge of plant safety to perform the respective tasks required, and in
doing so are able to recognise and avoid potential hazards. Among other things, knowledge of first-aid
procedures is also required.
Product liability
According to the product liability law every farmer is an entrepreneur!
According to §9 PHG (Product Liability Law), liability for damage to corporeal things caused by defective
products is expressly excluded. This exclusion of liability also applies to parts not manufactured by BAUER
itself but purchased from external suppliers.
Duty to furnish information
Even if he passes on the machine to a new owner later-on, the customer is obliged to hand on the operating
manual to the new owner, too. The receiver of the machine must be instructed with reference to the mentioned
regulations.
Intended use
BAUER CENTERSTAR 9000 has been constructed exclusively for use in normal irrigation (intended use).
Any employment beyond this normal use is considered non-conforming. The manufacturer is not liable for
damage resulting from such non-conforming use, the sole liability for damage from non-conforming use is
with the user.
Intended use also includes compliance with manufacturer’s operating, maintenance and service instructions.
BAUER
CENTERSTAR 9000 may be used and operated only by persons who are familiar with the system
and aware of the hazards involved.
Al l relevant rules for accident prevention as well as any other generally accepted specifications and
regulations relating to safety, work medicine and traffic law must be strictly observed.
Unauthorised modifications on the machine release the manufacturer from liability for damage resulting
therefrom.
WARNING !
CAUTION !
NOTE!

2Operating Manual for BAUER CENTERSTAR 9000
2 WARNING SYMBOLS
Danger points on the pivot system are specifically marked by safety stickers. These stickers must be affixed at
the mentioned points clearly visible and serve for protection of persons working on or near the system.
1.
WARNING !
Study and observe the manual and all safety instruction carefully before you put the system
into operation.
2.
WARNING !
Before maintenance and repair work, always stop the system, disconnect all power, and read
the operating manual.
3.
WARNING !
1. This system is powered by 400 Volts!
Danger of electrical shock / injury hazard !
2. Do not attempt to check any components while the system is live!
3. Open the inner pivot panel door only when main switch is OFF.
4.
WARNING !
1. The working range of the pivot must always be at a safe distance from electrical power
lines.
2. Pull towable systems only at a safe distance from electrical power lines.
Make sure that the water jet from spray nozzles and endgun does not hit electrical lines.

Operating Manual for BAUER CENTERSTAR 9000
3
5.
WARNING !
The system can start automatically. Always keep a safe distance from the towers.
6.
WARNING !
1. Do not remove shaft guards.
2. When repair work is performed on the system, make sure that system cannot start
running automatically. Disconnect the complete system from power.
3
4,5,6
3
1
2
4
3

4Operating Manual for BAUER CENTERSTAR 9000
3 GENERAL
BAUER CENTERSTAR 9000 is an irrigation system rotating around a fixed centre (pivot tower) and thereby
irrigating a full circle or a part circle.
The boom elements (towers, spans) are driven electrically.
The joints (tower couplings) mounted between the spans allow horizontal and vertical angular deviation between
the individual boom elements so that the system can adjust perfectly to existing site conditions.
Electric alignment controls between the spans control the horizontal angular deviation and ensure that the
system runs in a straight line.
Through varying spray nozzle set-ups and system speeds it is possible to tailor the water application exactly to
all possible plant and soil requirements.
4 GENERAL INSTRUCTIONS FOR SAFETY AND ACCIDENT
PREVENTION
Check the operational safety of the machine before every star.
1. In addition to the instructions in this manual, be sure to observe all specifications generally valid for safety
and accident prevention!
2. The warning signs and notes affixed to the machine contain information essential to safe operation.
Observing them serves your own personal safety!
3. Do not start the machine unless all guards and safety devices are mounted completely and in proper working
position!
4. Acquaint yourself with all system components and controls as well as their respective functions, before you
start to work. It is too late for this when the system is already running!
5. Check the vicinity of the system before start-up (children!). Make sure that sight is unobstructed!
6. For towing, couple the device according to the instructions and fix it only at the prescribed devices!
Electrical system check-up
1. Before the first start-up, check the electrical system and ensure that the installation complies with the safety
requirements.
2. Check the electrical system visually before every start-up.
3. All work beyond normal maintenance of the system is to be performed by a qualified service person only!
4. Never repair or service any part of the before all power has been disconnected!
Maintenance
1. As a rule, maintenance and cleaning work as well as repairs of malfunctions may be done only with the drive
and the motor turned off!
2. Check proper seat of nuts and screws regularly, and tighten them, if needed!
3. Dispose of oil, grease, and filters in accordance with regulations.
4. Always disconnect system from power before starting any work on the electrical system!
5. Before electrical welding on the system itself or built-on components, disconnect the mains or generator
supply cable!
6. Spare parts must meet minimum technical requirements by the manufacturer of the device.! This is
guaranteed by original equipment parts!

Operating Manual for BAUER CENTERSTAR 9000
5
5 SAFETY PRECAUTIONS FOR CENTERSTAR 9000
In addition to the GENERAL INSTRUCTIONS FOR SAFETY AND ACCIDENT PREVENTION, the following
safety principles must be observed for operating BAUER CENTERSTAR 9000.
5.1 GROUNDING
WARNING !
THE PIVOT SYSTEM MUST BE GROUNDED COMPLETELY!
1. All metal parts of the system must be connected with each other, all tower couplings must be bridged with a
cable.
2. The entire metal structure of the Pivot must be connected and grounded at the pivot tower with an earthing
rod or earthing bar in such a manner that the grounding resistance according to the legal code is reached.
3. In addition, the yellow-green protective conductor lead along with the power supply must be connected to
the grounding terminal in the control panel and therefore grounded properly.
4. Dimensioning of grounding, grounding nail or grounding bar must be executed by a qualified electrical
contractor.
5. For towable systems, suitable grounding connection must be provided at every pivot centre. In every new
system setting the grounding must be connected firmly with the pivot tower.
5.2 ELECTRICAL SYSTEM
WARNING !
Since system is powered by 400V, always practice extreme caution when dealing with the electrical
system and the electric drive !
1. Before working on system electrical components, make sure the system is disconnected from all poles and
sources.
2. Provide a lock-out at the main switch to protect yourself against unintentional reclosing.
3. Verify safe isolation from supply.
4. Never repair or short-circuit a fuse by means of a wire or any other item.
5. Immediately replace all wires with defective insulation.
6. Short-circuiting of system safety circuit is to be done only by a qualified person and only for the purpose of
realigning a span.
5.3 MECHANICAL SYSTEM
WARNING !
1. Never service or repair any part or system component while the plant is operating.
2. Always disconnect the system from power before starting any maintenance work. Turn the main switch to “0”
and lock the switch to prevent unintentional reclosing. Do not depend on others to disconnect the power – do
it yourself!

6Operating Manual for BAUER CENTERSTAR 9000
3. Before you start, make sure that all persons have left the operating range of the system !
4. Make sure that no objects or vehicles are in or near the system tracks when system is running/starting to
operate.
5. When the system is operating the towers come on and off automatically, therefore keep a safe distance from
the towers.
6. Never step on the system while it is running.
7. Utmost care is required by the operator when spans are aligned.
8. Always turn off the system and the water supply before working on sprinklers or spray nozzles.
9. Use adequate means of access (ladder, elevating platform) for work on sprinklers or spray nozzles.
10. Proceed with the utmost caution when system is working near or under electric power lines. Make sure that
neither the pivot system nor the water jets get in contact with live wires.
11.When towing movable systems you have to make sure that the system does not get in contact with a power
line.
12.Make sure that no neighbouring plots or roads are wetted by the endgun. This could cause damage or
accidents.
13.If fertilisers or other chemicals are added to the irrigation water, avoid the mist and do not inhale it.
6. TECHNICAL DESCRIPTION
1 Slip ring collector
2 Tower coupling
3 Pivot control unit
4 Truss rod
5 Bracing angle
6 Pipe
7 Tower brace
8 Wheel base
9 Driving motor
10 Drive shaft
11 Tower box
12 End control
13 Drive tower coupling
14 Transmission device

Operating Manual for BAUER CENTERSTAR 9000
7
PIVOT COMPONENTS
PIVOT
Fixed centre of the system around which CENTERSTAR 9000 rotates.
PIVOT PANEL
System controlling and monitoring device
COLLECTOR
Electrical connection by means of slip rings between the fixed pivot and the mobile spans.
PIVOT COUPLING
Vertically movable joint between pivot and first span.
SPAN
Arc-shaped truss structure consisting of pipes, truss rods and bracing angles.
PIPE
Water-conducting part of the machine.
TRUSS ROD
Round stock – connects the bracing angles.
BRACING ANGLES
Angle section – connects pipe and truss rods.
TOWER
Provides the electromechanical drive of the system and carries the span weight.
WHEEL BASE
Tower base with driving motor and gearbox.
TOWER BRACING ANGLE
Angle section – connects span and wheel base.
DRIVE MOTOR
Electric motor with reducing gear.
DRIVE SHAFT
Cardan joint between drive motor and gearbox with flexible intermediate element.
GEARBOX
Transmits the torque of the drive motor onto the wheels.
TOWER COUPLING
Joint between the spans. Possible articulation: up to 30 %.
ALIGNMENT CONTROL
Tower control system that monitors horizontal angular deviation between the spans and switches the drive
motors.
OVERHANG
Overhanging part from last tower to system end.
ENDGUN
Wide-range sprinkler at the end of the overhang serves for extra spraying system spraying range.
BOOSTER PUMP
Electric pump on the last tower for increase of pressure to endgun.

8Operating Manual for BAUER CENTERSTAR 9000
7 CONTROL UNITS
7.1 Control unit UNIVERSAL
Design and materials according to ÖVE and VDE standard, built-in components correspond with IEC standard
as well as VDE specifications.
Water-tight sheet steel cabinet (protection IP 54) with lockable front door and
corrosion-resistant coating.
Hinged control panel, can only be opened when main switch is switched off.
High-voltage connection: 3 x 400 V/50 Hz + PEN, power source with grounded
neutral conductor.
Control voltage: 230 V single-phase
Isolating transformer for control voltage
Commercial-type industrial switching devices
Cable connections with terminal ends
Hinged control panel which can only be opened when main switch is off.
7.1.1 STANDARD BUILT-IN COMPONENTS
Q 2 Main switch
Power infeed to the machine in position "1" .
For safety reasons the hinged control panel (inner door) is locked.
Q 2 Main switch
In position "O" the main switch is fitted with a lock-out against unintentional
reclosing.
The hinged control panel can only be opened in this switch position

Operating Manual for BAUER CENTERSTAR 9000
9
P 1 Voltmeter
Indicates the voltage between the phases L1 and L2.
P 2 Hour meter
Shows the total hours the system has operated.
S 1 CENTERSTAR OFF/ON switch
When turned to "ON" position, the system can be started by pushing the
buttons S2 or S3. If turned to “OFF” the system stops.
S 2 Illuminated "FORWARD START" pushbutton
Push this button to start the system in forward direction. The button is
illuminated as long as the system is operating in forward run (clockwise).
S 3 Illuminated „REVERSE START“ pushbutton
Push this button to start the system in reverse direction. The button is
illuminated as long as the system is operating in reverse run (counter-
clockwise)

10 Operating Manual for BAUER CENTERSTAR 9000
S 4 „SAFETY CIRCUIT ON-OFF“ switch
When turned “ON“, malfunction (e.g. doglegging) will shut off the entire system.
The “OFF” position serves exclusively for system alignment.
This switch MUST always be turned to “ON” while system is operating!
This is the only way to guarantee safety when system is operating unattended.
S 5 “WET-DRY“ switch
In the “WET” position, the system is shut down by means of a pressure switch
mounted on the infeed water pipe (optional) when pressure drops below the
limit. The “DRY” position allows to run the system dry (e.g. if the
CENTERSTART has to be returned to its parking position dry without
irrigating).
NOTE!
This switch is effective in combination with the automatic stop option only !
S 6 “STOP IN SLOT ON-OFF“ switch
In “ON“ position, the system stops in the desired parking position. The parking
position can be adjusted by shifting the momentary-contact limit switch on the infeed
water pipe.
NOTE!
This switch is only effective in combination with the AUTOMATIC STOP option!
K 4 Percentage timer "SPEED"
Speed adjustment.
The percentage timer is used to define the end tower run time per minute and thus
control the rotating speed of the pivot.
Setting the rotary button at 50 % therefore means that the end tower will run for 30
seconds and stand still for 30 seconds in one minute. This setting can be corrected
any time during the run.

Operating Manual for BAUER CENTERSTAR 9000
11
7.2 CONTROL UNIT UNIVERSAL PRO
Design and materials according to ÖVE and VDE norms; internals according to IEC corms and VDE
prescriptions.
Waterproof polyester box (protection class IP 54) with lockable front door.
Swivel mounted panel can only be opened when main switch is turned off.
Operating voltage of system : 400 V
Control voltage : 230 V single phase
Isolating transformer for control voltage
Industrial control gear usual in trade
Cable connections with cable shoes
Protective device
WARNING ! Keep control unit always locked during operation in order to prevent impurity and
splash water
1. Main switch
2. Panel UNIVERSAL PRO
3. Voltmeter
4. Hourmeter
5. Switch safety circuit „ON – OFF“
6. Luminous push button „safety circuit”
7. Switch “FORWARD – OFF –
REVERSE”
8. Switch „EMERGENCY MODE OFF-
ON
9. Switch „WET – DRY“
10. EMERGENCY STOP switch (not
shown on the picture)

12 Operating Manual for BAUER CENTERSTAR 9000
7.2.1 STANDARD BUILT-IN COMPONENTS
7.2.1.1MAIN SWITCH
The main switch turns off or on the entire power supply.
In position „I“ the electrical supply is established
In this position the swivel mounted panel is locked due to safety reasons.
In position „0“ the electrical supply of the system is cut off.
In this position the main switch can be locked in order to prevent an accidental or unintended turning on
Only in this position the swivel mounted panel can be opened.
7.2.1.2. CONTROL PANEL UNIVERSAL PRO
7.2.1.2.1 DISPLAY
Display with 2x16 signs, 2 lines, background lighting. If you do not use the keypad for a predetermined time, the
background lighting switches off automatically. (timer for background lighting adjustable).
7.2.1.2.2 FUNCTION/MENU BUTTONS
START FORWARD (F) Start the Pivot forward (clockwise)
START REVERSE (R) Start the Pivot backwards (anti-clockwise)
MENU and ENTER By pressing this key you get to the operator level – double usage for entering in the
programming modus of a parameter and for deleting an entry.
STOP (ESC and machine ) stop operation and multi–usage of this button for
operating at the technician level and for saving and leaving the programming
modus.
This manual suits for next models
6
Table of contents
Other Bauer Farm Equipment manuals
Popular Farm Equipment manuals by other brands

Glenmac
Glenmac Harley Pro 6 Operator's manual

HE-VA
HE-VA Sub-Tiller 3.0 m rigid Operating Instructions, Declaration of Conformity, Spare Parts List

First Products
First Products SEEDA-vator SE60 Operator's manual & parts list

Landoll
Landoll ICON AG11 Service and parts manual

agromaster
agromaster BIG-BAG LIFTER OPERATOR'S MANUAL AND SPARE PARTS

Te Pari