OM70-L1000.HV0700.VI1/4 29.5.2018
Optoelektronische Sensoren
Photoelectric sensors
Détecteurs opto-électroniques
Distanz-Sensoren
Distance sensors
Détecteurs de mesure de distances
Canada
Baumer Inc.
CA-Burlington, ON L7M 4B9
Phone +1 (1)905 335-8444
China
Baumer (China) Co., Ltd.
CN-201612 Shanghai
Phone +86 (0)21 6768 7095
Denmark
Baumer A/S
DK-8210 Aarhus V
Phone +45 (0)8931 7611
France
Baumer SAS
FR-74250 Fillinges
Phone +33 (0)450 392 466
Germany
Baumer GmbH
DE-61169 Friedberg
Phone +49 (0)6031 60 07 0
India
Baumer India Private Limited
IN-411038 Pune
Phone +91 20 2528 6833/34
Italy
Baumer Italia S.r.l.
IT-20090 Assago, MI
Phone +39 (0)2 45 70 60 65
Singapore
Baumer (Singapore) Pte. Ltd.
SG-339412 Singapore
Phone +65 6396 4131
Sweden
Baumer A/S
SE-56133 Huskvarna
Phone +46 (0)36 13 94 30
Switzerland
Baumer Electric AG
CH-8501 Frauenfeld
Phone +41 (0)52 728 1313
United Kingdom
Baumer Ltd.
GB-Watchfield, Swindon, SN6 8T
Z
Phone +44 (0)1793 783 839
USA
Baumer Ltd.
US-Southington, CT 06489
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
Baumer Electric AG · CH-8501 Frauenfeld
Phone
+41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Technische Daten Technical data Données techniques
Messdistanz Sd 100 ... 1000 mm measuring distance Sd 100 ... 1000 mm Distance de mesure Sd 100 ... 1000 mm
Fokusbereich 550 ... 850 mm focal range 550 ... 850 mm focal range 550 ... 850 mm
Strahlform Linie beam type line Forme du faisceau ligne
Messfrequenz 2500 Hz 2) measuring frequency 2500 Hz 2) Fréquence de mesure 2500 Hz 2)
Betriebsspannungsbe-
reich +Vs1)
15 ... 28 VDC voltage supply range
+Vs1)
15 ... 28 VDC Plage de tension +Vs1) 15 ... 28 VDC
Stromaufnahme max.
(ohne Last)
75 mA current consumption max.
(no load)
75 mA Consommation max. (sans charge) 75 mA
verpolungsfest ja, Vs zu GND reverse polarity protection yes, Vs to GND Protégé contre inversion polarité oui, Vs vers GND
kurzschlussfest ja short circuit protection yes Protégé contre courts-circuits oui
Fremdlichtsicherheit < 100 kLux ambient light immunity < 100 kLux Insensibilité à la lumière ambiante < 100 kLux
Arbeitstemperatur -10 ... +50 °C operating temperature -10 ... +50 °C Température de fonctionnement -10 ... +50 °C
Schutzart IP 67 protection class IP 67 Classe de protection IP 67
* Senderachse
* emitter axis
* axe émetteur
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Abmessungen Dimensions Dimensions Elektrischer Anschluss Connection diagram Schéma de raccordement
Technische Änderungen vorbehalten Sous réserve de modications techniquesTechnical specications subject to change
11200095
5
74
85
26
M12 x 1
7
64
9
9
50
4,5 2
55
LED
4,3
19
14
Z Z
Z Z
alarm
0V
analog
out
Rx/Tx+
Rx/Tx-
(8)
(7)
+Vs
RD
(2)
(4)
(5)
(6)
BN
YE
GY
PK
BU
sync in
(1)
WH
(3)
GN
push-
pull
RS 485
BN
= Braun/brown/brun
GN
= Grün/green/vert
YE
= Gelb/yellow/jaune
GY
= Grau/grey/gris
WH
= Weiss/white/blanc
PK
= Rosa/pink/rose
RD
= Rot/red/rouge
7
6
12
5
4
3
8
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
1) Class 2, UL 1310, see FAQ
OM70-11200095
OM70-L1000.HV0700.VI2/4 29.5.2018
Erklärungen zu Seite 1
Explanations for page 1
Déclarations à la page 1
1) Netzteil nach UL 1310, Class 2 oder externe Absicherung durch eine UL anerkannte oder gelistete Sicherung
mit max. 30VAC/3A oder 24VDC/4A.
Es wird ein 8-poliges, geschirmtes Anschlusskabel (Kabeldose) benötigt.
1) Voltage supply according UL 1310, Class2 or device shall be protected by an external R/C or listed fuse, rated
max. 30VAC/3A or 24VDC/4A.
Required is an 8-pin shielded cable (cable box).
1) L’alimentation utilisée, couvre la classe 2 selon la norme UL 1310 ou appareil protégé en externe par un circuit
R/C ou fusible UL à 30VAC/3A ou 24VDC/4A maximum.
Il s'agit d'un câble 8 broches blindé (décodeur) est nécessaire.
Montagehinweise
Mounting instructions
Indications de montage
Laserstrahl nie auf ein Auge richten.
Es empfiehlt sich, den Strahl nicht ins Leere
laufen zu lassen, sondern mit einem matten
Blech oder Gegenstand zu stoppen.
Do not point the laser beam towards
someone's eye. It is recommended to
stop the beam by a mat object or mat
metal sheet.
Ne dirigez jamais le faisceau vers un oeil.
Il est conseillé de ne pas laisser le faisceau
se propager librement mais de l'arrêter au
moyen d'un objet de surface mate.
VORSICHT CAUTION ATTENTION
Allg. Sicherheitsbestimmungen
General safety instructions
Instructions générales de sécurité
2) Messung auf 90% Reflektivität (Weiss) ohne Filterung / Mittelung
2) Measurement on 90% remission (white) without filtering / no averaging
2) Mesure sur 90% de rémission (blanc) sans filtrage / pas de moyenne
•Aus Lasersicherheitsgründen muss die Spannungsversorgung dieses Sensors abgeschaltet werden, wenn die ganze Anlage oder Maschine
abgeschaltet wird.
•Laser regulations require the power of the sensor to be switched off when turning off the whole system this sensor is part of.
•Pour des raisons de sécurité, l'alimentation de ce détecteur laser doit être coupée en cas d'arrêt total du système incorporan t ce détecteur.
10 - 15°
Gradins
Stufen
Steps
Runde, glänzende Oberflächen
Round glossy surfaces
Surfaces rondes brillantes
Glänzende Oberflächen
Glossy surfaces
Surfaces brillantes
Surfaces differemment réfléchissantes
Unterschiedlich reflektierende Oberflächen
Different reflection of surfaces
Einwirkung Fremdlicht
Effect of ambient light
Influence lumiére ambiante
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 640...670nm
IEC 60825-1, Ed. 3, 2014
CLASS 2 LASER PRODUCT
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007
OM70-L1000.HV0700.VI3/4 29.5.2018
Funktionsbaum
Function tree
Arbre de fonctions
LIVE MONITOR
PRECISON Standard
High
Very High
Highest
ANALOG OUTSCALE OUTDIST NEAR
DIST FAR
SET MAX VALUES
ANALOG OUTCurrent / Voltage
CHARACTERISTIC Pos. slope / Neg. slope
DIGITAL OUTDIGITAL OUTPoint / Window
SWITCH POINTValue in mm
WINDOW P1 Value in mm
WINDOW P2 Value in mm
OUTPUT LEVEL Active high / Active low
HYSTERESISValue in mm
SYSTEM TRIGGER MODE Continuous/Single shot
RS485 BAUD38400
57600
115200
230400
460800
921600
1500000
RS485 ADDR number
SENSOR INFO SENSOR TYPE
SERIAL NUM
LANGUAGE English
Deutsch
Inglese
Français
RESET Factory Set
SETTINGSAPPLY Setting 1
Setting 2
Setting 3
STORESetting 1
Setting 2
Setting 3
SHOW ACTIVE Values
SHOW SETTING 1Values
SHOW SETTING 2Values
SHOW SETTING 3Values
OM70-L1000.HV0700.VI4/4 29.5.2018
Distanz Funktion
Distance function
Fonction de la distance
WINDOW P2WINDOW P1
DIST NEAR
4mA / 0V
4mA / 0V
(factory)
20mA / 10V
(factory)
Blind range Measuring range MR
--+
+
HYSTERESIS HYSTERESIS
DIST FAR
20mA / 10V
WINDOW
(digital out)
ANALOG OUT
(scaled analog measuring range)

Other Baumer Security Sensor manuals

Baumer URCK 09G8914 User manual

Baumer

Baumer URCK 09G8914 User manual

Baumer URDK 10P8914/S35A User manual

Baumer

Baumer URDK 10P8914/S35A User manual

Baumer UNAM 50U6121 User manual

Baumer

Baumer UNAM 50U6121 User manual

Baumer UNAM 50U6121 User manual

Baumer

Baumer UNAM 50U6121 User manual

Baumer FPCK 07P6901/KS35A User manual

Baumer

Baumer FPCK 07P6901/KS35A User manual

Baumer UNDK 20I6903/S35A User manual

Baumer

Baumer UNDK 20I6903/S35A User manual

Baumer UNDK 20I6914/S35A User manual

Baumer

Baumer UNDK 20I6914/S35A User manual

Baumer FVDK 10N66Y0 User manual

Baumer

Baumer FVDK 10N66Y0 User manual

Baumer UNDK 30U6103 User manual

Baumer

Baumer UNDK 30U6103 User manual

Baumer URDK 10P8914/KS35A User manual

Baumer

Baumer URDK 10P8914/KS35A User manual

Baumer URCK 09G8914/KS35A User manual

Baumer

Baumer URCK 09G8914/KS35A User manual

Baumer FVDK 10P66YS Instruction manual

Baumer

Baumer FVDK 10P66YS Instruction manual

Baumer UNAM 30U6103 User manual

Baumer

Baumer UNAM 30U6103 User manual

Baumer OC60D.CC-11224547 User manual

Baumer

Baumer OC60D.CC-11224547 User manual

Baumer FVDK 10N66Z0/S35A User manual

Baumer

Baumer FVDK 10N66Z0/S35A User manual

Baumer UNDK 30U6112/S14 User manual

Baumer

Baumer UNDK 30U6112/S14 User manual

Baumer UNAM 18I6903/S14 User manual

Baumer

Baumer UNAM 18I6903/S14 User manual

Baumer UNDK 30U6112 User manual

Baumer

Baumer UNDK 30U6112 User manual

Baumer URAM 50P6121 User manual

Baumer

Baumer URAM 50P6121 User manual

Baumer UNDK 30U6112/S14 User manual

Baumer

Baumer UNDK 30U6112/S14 User manual

Baumer FZAM 18P6460 User manual

Baumer

Baumer FZAM 18P6460 User manual

Baumer UNDK 09G8914 User manual

Baumer

Baumer UNDK 09G8914 User manual

Baumer UNDK 30U6104 User manual

Baumer

Baumer UNDK 30U6104 User manual

Baumer FVDK 10P66Y0 User manual

Baumer

Baumer FVDK 10P66Y0 User manual

Popular Security Sensor manuals by other brands

LEGRAND WattStopper LMUC-100-2 quick start guide

LEGRAND

LEGRAND WattStopper LMUC-100-2 quick start guide

olympia electronics BS-116 Operation instructions

olympia electronics

olympia electronics BS-116 Operation instructions

netvox R313WA user manual

netvox

netvox R313WA user manual

Energy Absorption Systems Safe-Stop 180 Installation & operation

Energy Absorption Systems

Energy Absorption Systems Safe-Stop 180 Installation & operation

yellow jacket AccuProbe 69320 Operation and maintenance manual

yellow jacket

yellow jacket AccuProbe 69320 Operation and maintenance manual

Geca ST441 user manual

Geca

Geca ST441 user manual

ESYLUX PD-C360i/24 KNX UP operating instructions

ESYLUX

ESYLUX PD-C360i/24 KNX UP operating instructions

RKI Instruments 82-5223 Operator's manual

RKI Instruments

RKI Instruments 82-5223 Operator's manual

Elkron DC500 quick start guide

Elkron

Elkron DC500 quick start guide

Thinkcar PLD-212 user manual

Thinkcar

Thinkcar PLD-212 user manual

Honeywell Home PROSiXMINI Installation and setup guide

Honeywell Home

Honeywell Home PROSiXMINI Installation and setup guide

Rae EntryRAE manual

Rae

Rae EntryRAE manual

Hanhart PROFIL1 Instructions for use

Hanhart

Hanhart PROFIL1 Instructions for use

GE ARITECH 1500 Series Installation and maintenance guide

GE

GE ARITECH 1500 Series Installation and maintenance guide

BW Technologies GasAlert Extreme Quick reference guide

BW Technologies

BW Technologies GasAlert Extreme Quick reference guide

Bosch ZX835 installation instructions

Bosch

Bosch ZX835 installation instructions

sparkfun SEN-12642 HOOK-UP GUIDE

sparkfun

sparkfun SEN-12642 HOOK-UP GUIDE

Dilon Navigator 2.0 User and service manual

Dilon

Dilon Navigator 2.0 User and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.