1
88
3888
Ø 54
60
CleanSwitch
2 3
1TOP TOP
2Assembly
1Safety instructions
3Configuration
Translation of the original instructions
General
Front cover
Screw
Mounting frame
Poetry
Print module
Sensor housing
Housing cover
Contactless switch
English
367228F
4 Mode setting
1 – 3 Color settings
The device may only be installed and commissioned by trained specialist personnel.
Interventions and repairs on the device may only be carried out by the manufacturer.
The device may only be operated with protective extra-low voltage with safe galvanic isolation.
Always consider the safety functions of your application as a whole and never just refer to a single part of the system.
The risk assessment and the correct installation of the sensor and the system are the responsibility of the installer.
In general, avoid contact with electronic components.
ON
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
ON
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
ON
1 2 3
ON
4
Toggle-
Modus
ON
1 2 3
OFF
4
Pulse-
Modus
DIP-Switches
1-3 Optical feedback
4 ON Toggle-Modus
4 OFF Pulse-Modus
Factory settings
Insert the seal as marked.
Mounting option
2 Screw
Mounting option
4 Screw Dismantling
To press
until the click!
Hang the cover in at the top.
Detection range 0.1 - 0.5 m Color brightness
Blue/green
Red/Green
Green/red
Green/green
Red/Red
Blue/blue
-/Green
-/Blue
ON
ON
ON
Made in China / Designed in Switzerland
2
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com
min.
8.5
1
2
3
4
5
Technology Microwave - doppler radar
Frequency 24.125 GHz
Detection range 0.1 – 0.5 m
Detection mode Pulse mode: The sensor detects while the hand is moving
Toggle mode: first movement on / second movement off
Acquisition speed Min: 5 Hz oder ± 3 cm/s
Max: 200 Hz oder ± 1,2 m/s
Supply voltage 12-24 VAC ± 10 % (50-60 Hz)
12-24 VDC + 20 %/– 10 %
Max. Input < 1 W (with visual feedback)
Exit
Relay with changeover contact (potential-free)
Max. Switching voltage / switching current (DC): 1 A up to 30 V, 0.5 A up to 60 V
Max. Switching voltage / switching current (AC): 1 A up to 50 V
Max. Switching capacity: 30 W (DC) / 50 VA (AC)
Exit hold time «Relay hold time»: 0.3 s
«LED hold time»: 2 s
Storage / operating temperature – 20 bis + 60 ˚C
Protection class Ip65 (fixed with 4 screws, smooth surface)
Dimension (mm) 88 x 88 x 38 mm (L x B x T)
Weight 55 g
Materials ASA/PC
5Technical specifications
Note: According to the VAH list, CleanSwitch is resistant to surface disinfectants in hospitals.
9Contact
8FCC Approval
See Appendix
Devices with this symbol must be treated separately when they are disposed of. This must be in accordance with the
Laws of the respective countries for environmentally friendly disposal, processing and recycling of electrical and electronic
Devices.
6EU declaration of conformity
7WEEE
This device complies with Part 15 of the FCC rules and RSS-210 of Industry Canada.
Warning: Changes or modifications to this device could void your FCC authorization,
operate this device.
4Electrical connections
Stripping length at least 8.5 mm (solid wire or flexible wire)
White
Red
Green
Gray
Blue
Care –
Care +
Relay COM
Relay NC
Relay NO
2
AWG 24 – 16 / 0.2 – 1.5 mm
• Insert > solid wire
• Flexible wire > Press the button and plug it in

Popular Door Opening System manuals by other brands

Normstahl IDO7 installation manual

Normstahl

Normstahl IDO7 installation manual

Assa Abloy G-CO-C Mounting instructions

Assa Abloy

Assa Abloy G-CO-C Mounting instructions

argenta INVISIDOOR SDX-125 manual

argenta

argenta INVISIDOOR SDX-125 manual

Eco ETS 64-R Operator's manual

Eco

Eco ETS 64-R Operator's manual

Hettich Top Line 110 Assembly

Hettich

Hettich Top Line 110 Assembly

Eco TS-50 Assembly instruction

Eco

Eco TS-50 Assembly instruction

Dormakaba PORTEO Mounting instructions

Dormakaba

Dormakaba PORTEO Mounting instructions

Keyautomation LEVANTE Instructions and warnings for installation and use

Keyautomation

Keyautomation LEVANTE Instructions and warnings for installation and use

Dorma BEYOND Mounting instruction

Dorma

Dorma BEYOND Mounting instruction

FritsJurgens Top pivot Reversed Mounting manual

FritsJurgens

FritsJurgens Top pivot Reversed Mounting manual

GEZE ECturn Inside Installation and service instructions

GEZE

GEZE ECturn Inside Installation and service instructions

Kaba SLA operating instructions

Kaba

Kaba SLA operating instructions

Assa Abloy Besam SW300 Installation and service manual

Assa Abloy

Assa Abloy Besam SW300 Installation and service manual

Assa Abloy Norton 7970DPS-B Series installation instructions

Assa Abloy

Assa Abloy Norton 7970DPS-B Series installation instructions

Dorma ES 410 Mounting instruction and Operation manual

Dorma

Dorma ES 410 Mounting instruction and Operation manual

Colcom Biloba Unica 100E10 Instruction of Assembly

Colcom

Colcom Biloba Unica 100E10 Instruction of Assembly

Dorma RTS Series quick start guide

Dorma

Dorma RTS Series quick start guide

Face KBS1E Assemble manual

Face

Face KBS1E Assemble manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.