BEA LZR FLATSCAN VS305 User manual

LZR®- FLATSCAN VS305
EN
User’s Guide
PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOUR PRINTING
COMPACT LASER SCANNER

1
I. INTRODUCTION IN GENERAL
FLATSCAN VS305 is a detective laser scanner with single curtain.
Thanks to the compact and slim design it can be installed in the narrow gap easily and effectively seperate vechicle, and then
the output data can be used for vehicle anti-trailing, vehicle counting and other related applications.
The laser scanner is CLASS 1 certified device according to IEC 60825-1, which has no damage or impact on human eyes &
bodies. The visible laser spots are CLASS 2, which can be shut down during normal work.
With 400 spots scanning within the curtain, the scanner covers the detection area with high resolution, provides more accu-
rate application results . It could be used for a variety of applications with laser scanner technology. Convenient to install on
site with the transceiver design.
- Please read through the user‘s guide carefully.
- Please install, configure and use the devices in the given conditions illustrated in the user's guide.
- Please do not disassemble the device without authority of the manufacturer, otherwise the
manufacturer will not take any responsibility for the defect of devices.
- Please conduct self-evaluate for the functional feasibility when you intend to use outside of vehicle
seperation.
II. DESCRIPTION
3
2
1
4
56
1. Front Cover (protective cover)
2. Housing
3. Laser window
4. LED-signal
5. USB connector (internal use)
6. Visible laser beams
7. Internal calibration interface*
8. Screw hole(with screw kit)
9. Bracket (optional)
8
7
9
*DON'T OPEN!

2
9. Bracket (optional)
CAUTION!
Use of controls, adjustments or performance of procedures other than those specified herein may result
in hazardous radiation exposure.
Test the good functioning of the installation before leaving the premises.
III. LED-SIGNALS
IV. SYMBOLS
Caution!
Laser radiation Remote control
sequence Possible
remote control
adjustments
Factory values Attention Note
detection error LED
LED flashespower on no power or
LED is off
LED flashes quickly LED flashes slowly
V. SAFETY TIPS
The device contains IR and visible laser spots.
IR laser: Wavelength 905nm; Max. output pulse power 25W
(Class 1 according to IEC 60825-1)
Visible laser: Wavelength 635nm; Max. output CW power 0.95mW
(Class 2 according to IEC 60825-1)
The visible laser spots can be deactive during normal functioning.
The installer can activate the visible spots if needed.
CLASS 1 LASER PRODUCT
CLASS 2 LASER RADIATION
DURING INSTALLATION.
DO NOT STARE INTO BEAM
IEC 60825-1
CLASS 1 LASER PRODUCT
CLASS 2 LASER RADIATION
DURING INSTALLATION.
DO NOT STARE INTOBEAM
IEC60825-1
Do not look into the laser
emitter or the visible red
laser beams.
Only trained and qualified
personnel may install and
setup the scanner.
The warranty is invalid if
unauthorized repairs are
made or attempted by
unauthorized personnel.

3
VI. INSTALLATION AND MAINTENANCE
0°C
°C
°C
-10°C
Avoid the prensence of
smoke and fog in the
detection field.
Avoid condensation.
Avoid exposure to
sudden and extreme
temperature changes.
Avoid direct exposure
to high pressure
cleaning.
Do not use dry or dirty
towels or aggressive
products to clean
the laser window.
Clean the laser window
with compressed air.
When needed, wipe the
laser window only with
a soft, clean and damp
microfibre cloth.
Keep the scanner
permanently powered
in environments where
the temperature can
descend below -10oC.
Avoid extreme
vibrations.
Do not cover the laser
window.
Avoid moving objects
and light sources in
the detection field.
VII. INSTALLATIONS
1MOUNTING
Please do a thorough inspection and evaluation to the installation field to make sure the
way of installing the scanner is suitable to the application.
- Please strip away the front cover and make sure the laser window is not covered by
anything before power on and configuration.
- Always take appropriate action to secure the safety of installer.
- Grounding: Connect to the earth.
Bracket installation
- Choose appropriate or universal bracket according to the filed condition.
- Fix the scanner on the bracket in a proper position, where can make sure the laser window at its right angle.
- Fix the bracket with the scanner on a firm wall or pole where the laser curtain could shoot on the right place.
- Avoid moving objects in or near the detection field, or that may activate the scanner.
* The bracket is an optional accessary.

4
2 WIRING
- Only the authorized installer could implement the installation and configuration.
- If the environment temperature is lower than -10°C, please make sure the scanner keep power on.
- Avoid to use the scanner in environment with heavy rain/fog/vibration.
- Please install the sensor vertically for vehicle separation.
If the monitor is not connected, the cable must be wired to the power cable.
BLUE
RED+
BLACK
BROWN
GREEN
GROUNDING
CABLE
-
MONITOR TEST
YELLOW
WHITE
OUTPUT 1(OPTO)
PINK
GREY
VIOLET
OUTPUT 2(RELAY)
+
-
12-24V DC POWER SUPPLY
COM
NC
COM
NO
NC
*
*
Prepare the bracket for installation Fix the laser scanner on the bracket
at right position
Install the bracket with laser scanner
at a solid and appropriate place
* Output status when scanner is operational. ( Factory default connection )

5
VIII. HOW TO USE THE REMOTE CONTROL
30 minutes after last use, the scanner locks the access to the remote control session.
Cut and restore power supply. The remote control session is accessible again during 30 minutes.
Before use the remote control, please check the following points:
1. The effective control distance is 4 meters, please always use remote control within 4 meters of the scanner.
2. The scanner curtain should not be perpendicular to the high reflective surface, a 3-degree angle in between is
necessary to guarantee communication between the scanner and the remote control.
3. To avoid unexpected operation, the authorized operator or installer could set a password to get into the parameter setting
process.
After unlocking, the red
LED flashes and the scanner
can be adjusted by remote
control.
If the red LED flashes quickly after unlocking, you
need to enter an access code from 1 to 4 digits. To end an adjustment session,
always lock the scanner.
ADJUSTING ONE OR MORE PARAMETERS
x
CHECKING A VALUE
4 2
1 = field width: 4.2 m
X = THE NUMBER OF FLASHES INDICATES THE VALUE OF THE PARAMETER
x
RESTORING TO FACTORY VALUES
The access code is recommended for scanners installed close to each other.
teach-in
SAVING AN ACCESS CODE
DELETING AN ACCESS CODE
* Please complete this setting within 1 minute after power on.
* Setting will take effect 1 minute later.

6
IX. PARAMETER SETTINGS
(1)
(2)
(3)
(4)
(5)
(6)
(12) Detection field 1 (W)
(13) Detection field 2 (W)
(15) Check Values
(16) Lock
(17 Output configuration
(19) Multifunction key * 2
(7)
(8)
(9)
(10)
(11)
* 1
(14) Uncovered zone
(18) Antimasking & Background
(20) Immunity filter
(21) Detection mode
(22) LED activation
* 1. Mounting side: right
* 2. Match with other keys to change among different
functions
VISIBLE
SPOTS turn on /off the visble spots
- Confirm the wiring of the scanner.
- Power on.
- Switch on the visible spots, then align the curtain position precisely (refer to remote control instruction).
- Adjust the tilt angle to make sure the curtain covers the detection area approximately if necessary.
- The shape of laser spot is oval, the further the laser spot shoots, the bigger the spot diffuses, refer to
below diagram to calculate the size, avoid unwanted detections.
ALIGNMENT
Visible spot
Laser beam 43mm
21.5mm
Distance (m) b (mm) a (mm)
1 12.5 1.5
2 25 3
3 37.5 4.5
4 50 6
562.5 7.5
a=width
b= height
Do not look into the visible beams directly!
The visible spot has around ±1.5cm deviation at 3m distance, please makes sure the correct curtain position.The visible
spot is used for rough calibration only. It’s not sufficient to get the precise position only by visible spots.
0-9 Number keys
Detection field
Redirection
Plus
Unlock
Minus
Output activation delay
Min. object size
Detection area activation
Mounting side
Output termination delay
FOG FILTER

FACTORY VALUES
* For more information about installation, please refer to Application Note (AN).
7
MOUNTING
SIDE
right
left
The scanner can be configured at left side and right side.
Please note that the sensor will automatically find the mounting side during the teach-in process*.
After finishing teach-in process, use remote control to change the parameter if needed. This
parameter must be defined before setting the configuraiton, as the detection area will link to this
parameter.
W
H
W
H
left right
Parameter Setting ( Optional )
Please always make sure that the mounting side you adjusted is same as the actual one on site.
* Learn more about the Teach-in, please see page 12
TEACH-IN
TEACH-IN
setting the field 1&2 through Teach-in*
3s 3s max 30s
DETECTION
FILED
Detection area: detection will only happen when objects locate in the detection area. The
dimension of detection area could be adjusted by adjusting the parameter.
Please note that the detection range can be guaranteed with 5% reflectivity @4m diagonal
when fog filter value is set to 0, if the fog filter value is not 0, then the guaranteed detection
distance will be shortened with 5% reflectivity.
*
400 cm
0 - 550 cm
W
FIELD 1
400
0 - 550 cm
W
FIELD 2*
cm
Parameter Setting ( Optional )
7

FACTORY VALUES 8
UNCOVERED
ZONE 10 20 25 30 35 40 45 50
5cm15
Uncovered zone: increase in case of snow, dead leaves, etc. Measured in specific condi-
tions and determined by application and installation.
IMMUNITY
FILTER >
low
no
filtering >high
Immunity Filter: when there’s interference from environment such as rain, snow which
could create some false detection, occasional false detection could be decreased by
increasing immunity level.
10 15 20 25 30 35 40
off cm
5 8
MIN. OBJECT
SIZE
Minimum object size: continuous detection will only happen when object size is bigger
than the given minimum object size.
OUTPUT
ACTIVATION
DEL AY
20 200 300 400 500 600 7000ms
10050
Output activation delay: the detection will generate output only when
detection lasts longer than the given number.
374 299 274 250400 cm
324349
FOG FILTER
Fog filter: different values means different max. detection distances with 5%
reflectivity.
DETECTION
AREA
ACTIVATION
field 1 field 2off
Detection area activation: detection field 1 or detection field 2 can be actived or
deactived.
field 1 and
field 2

FACTORY VALUES
9
DETECTION
FIELD
REDIRECTION
R1
R2
field 2
field 1 error
alarm
field 1 or
field 2
field 1
field 2
error
alarm
field 1 or
field 2
DETECTION
MODE
LED
ACTIVATION LED OFF LED ON
OUTPUT
CONFIGURATION R1 NC
NC
NO
NO
NO
NC
NO = normally open
NC = normally closed
NO
NC
NO NC
NO POWER
NO DETECTION
DETECTION
*R2
* R2 R2 default connection: Pink/ Grey
ANTIMASKING &
BACKGROUND
Antimasking: when laser window is covered, the scanner will go into error mode. Back-
ground: when background is changed, the scanner will go into error mode.
antimasking ON
OFF
ON
ON
OFF
OFF OFF
ON
background
50 200 300 400 500 ms
10020 80
OUTPUT
TERMINATION
DEL AY
Output termination delay:After the detection signal disappears, the output will
remain the set duration, then switch off.
HD MODE HS MODE
HD:
HS:
High resolution mode
High speed mode
Please lauch a new teach-in with every adjustment.

FACTORY VALUES
10
TEACH-IN
Teach-in: the scanner could automatically learn the environment profile as its detection field
with self-learning function; this feature provides great convenience when there are irregular
objects exist within the detection field which should be considered as background.
setting the field 1 through Teach-in.
setting the background through Teach-in.
setting the field 2 through Teach-in.
3s 3s max. 30s
3s 3s max. 30s
3s 3s max. 30s
RESET TO
FACTORY
SETTINGS
reset all the parameters to factory settings.
reset all the parameters outside of the detection field to factory settings.
IMPORTANT: Test the good functioning of the installation before leaving the premises.
3s 3s 30s
setting the field 1&2 through Teach-in.
3s 3s max. 30s
The ORANGE LED is on
permanently.
The scanner encounters a
memory problem.
Send the scanner back for a technical check-up.
The ORANGE LED flashes
1 x /2 x /3 x every
3 seconds.
The scanner signals an
internal fault.
If the internal error still exists
after 3 resettings, the LED will
flash 9 times and the scanner
will be locked.
1Cut and restore power supply.
2If orange LED flashes again, send the scanner back
to manufacturer.
The ORANGE LED flashes
4 x every 3 seconds.
Error for antimasking or
boundary.
1Check if there’s pollution on front window.
2Check if there’s problem of background.
The ORANGE LED flashes
5 x every 3 seconds.
Error happened during the
teach-in process.
Relaunch a teach-in process.
2
1
3
4
5
X. TROUBLESHOOTING
The FLATSCAN VS305 is designed to be able to give trouble shooting through LED.
10

XI. TECHNICAL SPECIFICATIONS
Technology LASER scanner, time-of-flight measurement
Max. detection range Max. 5.5m*5.5m (4m@5% reflectivity)
Opening angle 90°
Angular resolution 0.23° (400 spots within 90°)
Emission characteristics Wavelength 905nm; Max. output pulse power 25W (CLASS 1)
Wavelength 635nm; Max. output CW power 0.95mW (CLASS 2) Visible spot
Supply voltage 12-24V DC ± 15%
Power consumption ≤ 2.3W, peak current: 1A
Output 1 opto (galvanic isolation - polarity free)
Max. switching voltage: 42V AC/DC
Max. switching current: 100mA
1 Relay (free of potential contact)
Max. contact voltage: 42V AC/DC
Max. contact current: 1A (resistive)
Max. switching power: 30W DC/60VA AC
LED-signals 1 tri-colored LED: detection / output status
Colour Black
Tilt angles ±3° (with bracket)
Protection degree IP66 (EN 60529)
Temperature range -30°C to +60°C if powered
Humidity 0-95% non-condensing
Vibrations < 2G
Norm conformity IEC 60825-1; EN 60950-1; EN 61000-6-2;
EN 61000-6-3; EN 60529; EN 50121-3-2
Specifications are subject to change without prior notice. All values are measured in specific conditions.
BEA / A-B Area, 3rd Floor, No.1 Building /No.5 Xinghai Road, Beijing Economic Technological Development Area, Beijing / CHINA
©BEA | Instructions | 69.1333.V1 | 2020.09
BEA hereby declares that the LZR®-FLATSCAN VS305 is in compliance with European directives 2014/30/EU and
2011/65/EU.
FOR EC COUNTRIES: THIS PRODUCT SHOULD BE DISPOSED OF SEPARATELY FROM UNSORTED MUNICIPAL WASTE.
SAFETY INSTRUCTIONS
The integrator or installer that use the sensor is responsible for carrying out a risk assessment and installing the scanner and
the system in compliance with applicable national and international regulations and standards.
Only trained and qualified personnel may install and setup the scanner.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | EU.BEASENSORS.COM
THIS USER'S GUIDE IS AN INFORMATIVE DOCUMENT AND CAN NOT BE SEEN AS A COMMITMENT OF RESULT.