75.5984.03 LZR-H100 20191125 Page 5 of 16
0°
45°
90°
0° 0°
0° 0°
6"
The sensor and detection field position are very important
for the safe operation of the barrier.
In order to position the sensor correctly, use the 3 visible
red laser beams.
The visible laser beams are also used to determine the
location of the reference of the sensor.
It is important to understand the basic setup features before installing the sensor.
The sensor must learn a reference when the safety field is
the only protection against contact between the vehicle
and the boom.
The reference can be adjusted on any type of object
already present on site (wall, tree, barrier boom support)
or on a post.
Always make sure the object on which the reference is
adjusted:
• is positioned in the continuity of the 0° laser beam
• is positioned min. at the end of the barrier or farther
away than the end of the barrier
• has a surface of at least 6 inches
• is firmly fixed to floor and not subject to vibrations
Use reflective sticker (supplied) when the distance
between sensor and reference is higher than 16.5 feet.
FOR BEST RESULTS:
• use the reflective sticker
• place the sticker horizontally on the
structure (as shown)
• center the laser’s red spot on the reflector
If the safety field is the only protection against contact
with the barrier, the safety field of the sensor must be
situated directly below the barrier.
This is only possible when the sensor is positioned
correctly and the reference has been learned.
If the reference is situated at the end of the barrier,
the detection field width is the same as the reference
distance.
If the reference is farther away, adjust the detection field
width to the width of the barrier.
In order to maximize safety for mixed traffic (vehicles
and trucks), an additional vertical detection zone is
recommended (LZR-I30).
REFERENCE
VISIBLE RED LASER BEAMS
SAFETY FIELD
BASIC SETUP FEATURES