BEINAT SC100 User manual

CONFORMITY
EN 61010-1
DM01/02/1986
Belonging to
Solar Panels control "Solar Control" SC100 / 3
V. 4
The thermostat is an electronic instrument based on BEINAT’s many years of experience in temperature
control.
This device allows maintaining precise control of the temperature of the solar panels connected to the boiler’s
sanitary hot water.
It detects the boiler water temperature through the 3 provided sensors and compares it with the solar panels
fluid.
When the panels temperature is higher than the boiler’s water, the control unit starts the pump allowing thermal
exchange between panels and boiler.
Its second main function is to use a supplementary source of heat when the temperature is lower than the set
integration temperature.
In order to ensure a perfect thermal exchange, the device is fitted with a “delta T” temperature differential that
varies from 1 to 9°C, and can be regulated using the knob on the thermostat front panel.
Thanks to the 3-module Omega-type format, you can build several systems exploiting the modularity of the
DIN rail in the previously set electrical panels.
Important: Assembly / maintenance of the appliance must be carried out by qualified personnel
and in accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with
particular environmental and / or installation standards.
Important note
Before connecting the equipment, it is recommended that you read the instruction manual
carefully and keep it for future reference. It is also recommended to perform the electrical
connections correctly as per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side
INSTALL IN SAFE
AREA, NO ATEX
Installation
and user guide
Channel: Beinat gas solutions
Electric connections also available on

Page 2
CHECK the integrity of the thermostat after having removed it from the box.
Check that the data written on the box correspond to the product.
Any use of the detector for purposes other than the intended one is considered
improper, and as a result of which BEINAT S.r.l. therefore disclaims any responsibility
for possible damages caused to people, animals or objects.
Never clean with chemical products. If necessary after remove the voltage, wash with
a moist cloth.
Entrust always the installation and maintenance to technicians qualified and / or authorized
which can ensure the original spare parts in case of failure.
No. 1 SOLAR CONTROL SC100 control unit
No. 3 Temperature probes in thermoplastic weatherproof case,
immersion version with IP55 protection degree
Accessories on demand
Immersion version temperature probes with chromium plated weatherproof case art.
ST400
Power supply ............................................................................................................ 230V~ ±10% 50Hz
Power demand ........................................................................................................................... 1 VA
Relay Contact Range .......................................................................... 10A 250V resistive 5A 30V resistive
Free of voltage contacts
Type of sensors ..................................................................................................................... NTC 47K
Functioning temperature sensors ...................................................................................... -20°C to 120°C
Accuracy .................................................................................................................................... ± 1°C
Resolution ................................................................................................................................... 1 °C
Delta differential temperature ............................................... ................... Adjustable from 0 ° C to 9 ° C
Integration temperature .............................................. ......................... Adjustable from 30 ° C to 80 ° C
Integration Switch ......................................................................................................... Automatic, Manual
Force pump switch on the panel ................................................................................................. Built in
Functioning temperature sensors ........................................................................................-20°C .. 120°C
Max. distance between probes and unit ......................................................................................... 150 m
Cable diameter for connecting probes ......................................................................................... 1 mm2
Functioning temperature ...................................................................................................... 0°C to 50°C
Storage temperature ....................................................................................................... -10°C to +60°C
Humidity limits ....................................................................................................... 90% RH non-condensing
Electromagnetic Compatibility “CE” ................................................................................. Reference norms
Degree of protection ............................................................................................................... IP20 air
Omega-type size DIN EN 50092 3 modules ................................................................................... 53*90*58
Mounting ............................................................................................................................. Panel mounted
90 mm
45 mm
37 mm
52 mm
90 mm
44 mm
Integrazione
Pompa
Useful information
Check package contents
Technical features
Immersion version temperature probes with chromium plated weatherproof case art.
ST400

3
1
2
80
50
30
Integrazione
60
40
SC100/3
70
5
Pompa 4
5
Page 3
1) “Power connected” LED, thermostat working.
2) Automatic/Manual Switch for sanitary hot water
integration.
AUTOMATIC. By setting the switch up, you select the automatic
functioning.
a) Automatic. functioning works according to the tempera-
ture set using the graduated knob from 30°C to 80°C. Please
see point No. 4
b) Manual. By setting the switch down, you select the manual
functioning.
When selecting the manual functioning, the integration is
always ON.
3) Forced pump insertion switch, between boiler and
panel.
By setting the switch down, you select to forcedly insert the
circulation pump between panel and boiler.
4) Temperature selection knob. It is used to set the
desired sanitary hot water temperature before activation of
the integration.
5) DELTA T knob on the panel. It is used to program the
temperature difference between BOILER and PANEL. It was
set to 5°C in the factory.
Electrical connection of the
terminal block at the bottom
The immersion probes can be inverted one
with the other both for position and polarity
Max. distance 150 m, with minimum diameter
of 1 mm2
Electrical connections
C
NC
NO
1 2 3 4 5 6
C
NC
NO
Pump
Connection Integration
Connection
Power Supply
230 VAC
Electrical connection of the
terminal block at the top
The relays schematized are free
voltage with a capacity of 10 A
resistive.
1 2 3 4 5 6
S1 S2 S3
Panel
probe
Boiler H2O
integration
sensor
Boiler H2O
accumulation
sensor
If the device does not turn on: Check that all the 230V cables are
firmly connected the terminal block’s poles 1 and 2. Check if the
mains power supply is present.
The control unit works well but cannot drive the appliances:
Check that all the wiring is correct.Please remind that all relays are
free of voltage.Check that the resistive values are right. Please see
table on the side.
If other problems arise, a specialised and/or authorised technician
and/or the Distributor of BEINAT S.r.l. should be contacted directly.
Before calling a technician, check...
WARNING
Before connecting to the mains power, ensure the voltage is correct.
Carefully follow the instructions and the connections according to Regulations in force, keeping in
mind that the signal cables should be laid separate from the power cables.
An automatic cut-off switch (appropriately identified as devicesectioning of the detector) should
be incorporated in the electrical system, adequatelylocated and easily accessible.
SC100/3 Components and Commands
Temp. Resistive Temp. Resistive
values values
0°C 155.820 10°C 94.523
30°C 37.704 40°C 24.695
50°C 16.533 60°C 11.296
70°C 7.865 80°C 5.573
95°C 3.427 100°C 2.936
SENSORS
Conversion from temperature
to ohmic value of the probes

BE-Rev 4 09 18
Business - info@beinat.com
Help Desk - laboratorio@beinat.com
BEINAT S.r.l.
Via Fatebenefratelli 122/C 10077, S. Maurizio C/se (TO) - ITALY
Tel. 011.921.04.84 - Fax 011.921.14.77
http:// www.beinat.com
IP30 Made in Italy
Lo styling è della b & b design
Stamp and signature of the dealer
Date of purchase:
Serial number:
Beinat S.r.l. following the purpose of improving its products, reserves the right to change the technical, aesthetic and functional characteristics
at any time and without giving any notice.
Solar thermostat SC100/3
INSURANCE. This device is insured by the SOCIETÀ REALE MUTUA for the PRODUCT'S GENERAL LIABILITY
up to a maximum of 1,500,000.00 EURO against damages caused by the device in case of failures in functioning.
WARRANTY. The warranty term is 3 years from manufacturing date, in agreement with the following
conditions. The components acknowledged as faulty will be replaced free of charge, excluding the replacement
of plastic or aluminium cases, bags, packing, batteries and technical reports.
The device must arrive free of shipment charges to BEINAT S.r.l.
Defects caused by unauthorized personnel tampering, incorrect installation and negligence resulting from
phenomena outside normal functioning shall be excluded from the warranty.
BEINAT S.r.l. is not liable for possible damage, direct or indirect, to people, animals, or things; from product
faults and from its enforced suspension of use.
DISPOSAL OF OLD ELECTRICAL & ELECTRONIC EQUIPMENT.
This symbol on the product or its packaging to indicates that this product shall not be treated as household waste. Instead, it shall be handed over to
the applicable collection point for the recycling of electrical and electronic equipment, such as for example:
- sales points, in case you buy a new and similar product
- local collection points (waste collection center, local recycling center, etc...).
By ensuring this product is disposed of correctly, you willhelp prevent potential negative consequence for the environment and human health, which could
otherwise be caused by inappropriate waste handing of this product. The recycling of materials willhelp to conserve natural resources. For more detailed
information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased
the product.
Attention: in some countries of the European Union, the product is not included in the field of application of the National Law that applies the European
Directive 2002/96/EC and therefore these countries have no obligation to carry out a separate collection at the “end of life” of the product.
Table of contents
Other BEINAT Thermostat manuals
Popular Thermostat manuals by other brands

White Rodgers
White Rodgers 1F97-71 installation instructions

VDH
VDH ALFA D1-DP user manual

eControls
eControls Comfort365 C365C32 Installer manual

Element4
Element4 E-Save user manual

Robertshaw
Robertshaw RS2110C Series Installation and user manual

S+S Regeltechnik
S+S Regeltechnik HYGRASREG RH-2 Operating Instructions, Mounting & Installation