GE RAK160W2 Original instructions

THERMOSTAT
Wireless Thermostat with two fan speeds
OWNER’S MANUAL &
INSTALLATION INSTRUCTIONS
RAK160W2
49-5000637 Rev. 0 05-22 GEA
F

249-5000637 Rev. 0
THANK YOU FOR MAKING GE APPLIANCES A
PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is
your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and
design that goes into every GE Appliances product,
and we think you will too.

49-5000637 Rev. 0 3
Table of Contents
Safety Information.................................................... 4
Before You Begin.......................................................5
Thermostat Installation............................................ 7
Installing the Wireless Control card................................7
Wireless Installation .....................................................10
Wired Installation..........................................................10
Thermostat Configuration.....................................11
Setting the clock...........................................................12
Entering the room number ...........................................13
Configuring the Equipment Settings.............................14
Custom Energy Savings Settings...................... 16
Using the Thermostat Settings Screens.......................17
01 – FAN CONTROL MODE........................................18
02 – 1ST STAGE DIFFERENTIAL - HEAT..................19
03 – 2ND STAGE DIFFERENTIAL - HEAT.................20
04 – 1ST STAGE DIFFERENTIAL - COOL.................21
07 – FORCED 2ND STAGE HEATING .......................22
17 – MINIMUM SET POINT.........................................23
18 – MAXIMUM SET POINT........................................23
19 – TEMPERATURE CONTROL MODE....................24
20 – AUTO CHANGEOVER SET POINT OFFSET
(DEAD BAND)......................................................25
23 – TEMPERATURE CALIBRATION.........................26
Thermostat Maintenance......................................27
Troubleshooting........................................................28
Technical Specifications.......................................31
Limited Warranty......................................................32

449-5000637 Rev. 0
Specifications.
WARNING FIRE AND SHOCK HAZARD
• Always turn off power at the main power supply
before installing, cleaning or removing the
thermostat. Failure to do so could result in
electrical shock hazard.
• Do not use on voltages over 30 VAC. Higher
voltages will damage the thermostat and could cause
shock or fire hazard.
NOTICE
• All wiring must conform to local and national
electrical and building codes.
• Use this thermostat only as described in this manual.
Electrical rating:• 24 VAC (18–30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
Operating temperature range: 40°F–99°F (4°C–37°C)
System Configurations:
* 1 stage cool, 2 stage heat (heat pump/resistance heat)
1 stage cool, 1 stage heat (resistance heat)
Terminations: *R, C, W, Y, GH, GL, B for 2-stage heat
R, C, W, Y, GH, GL, for 1-stage heat
Wiring (for R & C if wiring for power): Maximum wiring
length is 66ft (20 meters) for AWG18
Maximum wiring length is 60ft (18 meters) for AWG20
*Default setting
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING

49-5000637 Rev. 0 5
Before You Begin
• Determine the appropriate installation location for the
thermostat
The thermostat must not be installed near or on
metal structures or surfaces including metal air
ducting that may be in the wall.
0HWDOVWUXFWXUHVDQGVXUIDFHVVLJQL¿FDQWO\
reduce the range of the wireless signal.
A. Refer to the Zoneline Owner’s Manual to enable the
use of a wall thermostat. For AZ45/65 Series Models,
auxiliary mode 6 should be set to “6A”.
B. Zoneline output is 24VAC. Be sure the jumper on the
wireless control card is on the AC position – jumper
is connecting “R” and “C” (common) pins. This is the
default position.

649-5000637 Rev. 0
NETWORK INSTALLATION ONLY
NOTE: This section is not required unless the thermostats are
networked
Pairing the Thermostat and the Control Card:
In case of Network Installation with online management, the
thermostat and the Control Card must be paired with a Network
Programmer specific to the property before the installation.
Note: Thermostat and Control Card are factory paired.
The thermostat and control card must not be powered during the
pairing procedure - remove batteries from the thermostat and unplug
the control card from the HVAC unit during the pairing procedure.
• Plug one programmer connector into the thermostat;
• Plug the other programmer connector into the control card.
• Push the black button on the programmer.
•
The red light on the programmer should turn on and remain
steadily lit.
•
If the red light on the programmer is blinking or is not steadily
lit, unplug the programmer from the thermostat and the control
card and repeat the steps above.
• Unplug the programmer from the thermostat and the control card.
Thermostat Network
Programmer
Programmer
Connector
Control
Card

49-5000637 Rev. 0 7
Thermostat Installation
Installing the Wireless Control Card
• Power off the Zoneline
• Insert the Control Card wiring harness into the thermostat
connection port on the front of the Zoneline control box cover.
AC input
Remote
Thermostat
Connection
Red Aux Set
Button
Image 1

849-5000637 Rev. 0
Thermostat Installation
Installing the Wireless Control Card (cont.)
• Using double sided tape, attach the control card to the Zoneline
control box cover (see image 2).
The wireless control card antenna must not be touching any metal
components of the hvac unit.
The wireless control card antenna must face the thermostat on the
wall and be oriented so that any metal parts of the Zoneline do not
obstruct the wireless communication to the thermostat and, in case of
a network installation, to other wireless control cards and the server.
The wireless control card must not be placed in the Zoneline
condensation pan and must be mounted so it cannot fall into the
condensation pan.
• For wired applications, join the common and 24VAC wires with
any code-approved low voltage field supplied connection method.
CDC/
Occupancy
Note: This
connector is
not required for
RAK160W2
Remote
Thermostat
Connection
Control
Card
Image 2

49-5000637 Rev. 0 9
Thermostat Installation
Wire Color Terminal Letter Terminal Connection
Black C Common
Red R 24V
Yellow Y Compressor
White W Heat
Orange O or B Reversing Valve
Green GH Fan High
Purple GL Fan Low
NOTE: If the PTAC unit has only one (1) fan speed,
connect both fan control wires – Green and Purple –
to the fan terminal (G).
Wiring Table – 24V AC

10 49-5000637 Rev. 0
Thermostat Installation
Wireless Installation
GH OB W R Y C
AUX
GL
F
Mounting the thermostat to the wall
• Remove the thermostat cover;
• Use the supplied wall anchors and mounting screws to
secure the thermostat to the wall;
• Insert two (2) AA-cell batteries (not supplied) into the
thermostat battery compartment;
• Follow the “Thermostat Configuration” instructions
starting on page 11.
• Replace the thermostat cover and screw in the locking
screw.
Wired Installation
GH OB W R Y C
AUX
GL
R C
F
Mounting the thermostat to the wall
• Connect R & C from HVAC unit to the corresponding
wires on the harness by splicing 24VAC and common
wires from the thermostat into the 24VAC and common
wires to the zoneline.
• Remove the thermostat cover;
• Use the supplied wall anchors and mounting screws to
secure the thermostat to the wall;
• Follow the “Thermostat Configuration” instructions
starting on page 11.
• Replace the thermostat cover and screw in the locking
screw.

49-5000637 Rev. 0 11
Thermostat Configuration
Once the thermostat is powered, thermostat configuration
settings will appear on the thermostat screen.
In order to properly operate the HVAC unit:
• Set the thermostat clock
• Enter the room number
• Configure the equipment settings
The thermostat configuration screens have a 30-second
time-out. If no action is taken within thirty (30) seconds, the
thermostat will exit configuration settings.
NOTE: You can
access Thermostat
Configuration settings at
any time by pressing the
“Configuration” button.
NOTE: If the
thermostat is connected to a network, the settings
configured online will be applied.

12 49-5000637 Rev. 0
Thermostat Configuration
Setting the thermostat clock
Set the thermostat clock to current time in 24h (Military Time)
format.
• Use the “Up” and “Down” buttons to set the hours
• Press the “Fan” button to advance to the minutes setting
• Use the “Up” an “Down” buttons to set the minutes
• Press the “F/C” button to advance to the next menu
Setting the clock correctly is crucial for proper operation of
the thermostat.
NOTE: The thermostat clock will need to be reset each time
the batteries are replaced.
Hours Minutes

49-5000637 Rev. 0 13
Thermostat Configuration
Entering the room number
Enter the room number by changing the digits on the screen.
Leading zeros “0” preceding other digits will be ignored, i.e.
Room number “123” should be entered as “00123”.
• Use the “Up” and “Down” buttons to change the digit;
• Press the “Fan” button to advance to the next digit;
• Press the “F/C” button to advance to the next menu;
Entering the room number correctly is crucial for proper
operation of networked systems.

14 49-5000637 Rev. 0
Thermostat Configuration
Configuring the Equipment Settings
• Use the “Up” and “Down” buttons to change the value of
each setting. Reference chart below for options.
• Press the “Fan” button to advance to the next setting.
• Press the “Power” button to save the Thermostat
Configuration and start using the thermostat.
Value Compressor Type Electric Heat Reversing Valve Fan Speed
0 No Compressor No Electric
Heat O/B Contact is
energized to cool N/A
1 Heat Pump* Electric
Heat* O/B Contact is en-
ergized to heat* One Fan
Speed
2 Air Conditioner N/A N/A Two Fan
Speeds*
3N/A
Three Fan
Speeds
* Indicates default setting
NOTE: If the Zoneline is an AZ45 or AZ95E model, change
the compressor type to a 2.
Compressor
Type Electric
Heat Reversing
Valve
Fan
Speed

15 49-5000637 Rev. 0
Thermostat Configuration
Testing the thermostat
Following the thermostat configuration, test if the thermostat
is controlling the Zoneline unit.
• Press the “Power” button to turn the thermostat ON;
• Press the “Down” button to change the temperature set
point below the current room temperature to confirm that
the thermostat initiates air conditioning.
• Press the “Up” button to change the temperature set point
above the current room temperature to confirm that the
thermostat initiates heating.
• Change the fan speed by touching the “Fan” button to test if
the thermostat is controlling the fan speed.

49-5000637 Rev. 0 16
Custom Settings
This thermostat comes preprogrammed to use a custom
energy setting. To change any of these presets, follow the
instructions below.
Accessing the Thermostat Settings
With the thermostat turned on, press and hold the
“Configuration” button until the first thermostat settings screen
appears. The thermostat must be turned on to access the
thermostat settings.
³&RQ¿JXUDWLRQ´EXWWRQ
NOTE: If the thermostat is connected to a network, the
settings configured online will be applied.
• Use the “Up” and “Down” buttons to change the setting;
• Press the “F/C” button to advance to the next setting;
• Press the “Fan” button to return to the previous setting;
• Press the “Power” button to save and exit thermostat
settings.

17 49-5000637 Rev. 0
Custom Settings
Using the Thermostat Settings Screens
• Use the “Up” and “Down” buttons to change the setting.
• Press the “F/C” button to advance to the next setting.
• Press the “Fan” button to return to the previous setting.
• Press the “Power” button to save and exit thermostat
settings.
The above is a representation of how to read the
digits on the thermostat screen.
Setting Value
Screen Number

49-5000637 Rev. 0 18
Custom Settings
01 – FAN CONTROL MODE
Select Fan Control Mode:
00 - MANUAL - guest can select automatic or continuous
fan mode.
01* - AUTOMATIC - fan runs only when there is a
demand for heating or air conditioning.
* Indicates default setting.

19 49-5000637 Rev. 0
Custom Settings
02 – 1ST STAGE DIFFERENTIAL - HEAT
(0.2°F - 3.0°F; 1.0°F* default setting) Select the number
of degrees** the thermostat has to sense between the
automatic changeover temperature for heat and the room
temperature before a call for the 1st stage heating is
initiated.
** above the dead band offset (refer to page 25)

49-5000637 Rev. 0 20
Custom Settings
03 – 2ND STAGE DIFFERENTIAL - HEAT
(1.0°F - 2.0°F; 1.0°F* default setting) Select the difference
between 1st stage heating and 2nd stage heating
initiation.
Table of contents
Languages:
Other GE Thermostat manuals

GE
GE RAK149F2 Original instructions

GE
GE RAK148D2 Original instructions

GE
GE RAK348T1 User manual

GE
GE RAK148F2 Operating instructions

GE
GE RAK148D1 Original instructions

GE
GE RAK148D1 Original instructions

GE
GE RARWT Series Original instructions

GE
GE RAK149P2 Original instructions

GE
GE PROGRAMMABLE THERMOSTAT User manual

GE
GE RAK150VF2 User manual

GE
GE RAK348R1 User manual

GE
GE CC-SCSTAT User manual

GE
GE RAK147P1 Operating instructions

GE
GE RAK148P1 Original instructions

GE
GE RAK190V User manual

GE
GE RARWT Series Original instructions

GE
GE RARWT Series Original instructions

GE
GE RAK148P2 Original instructions

GE
GE RARWT1W Original instructions

GE
GE RAK148H2 Original instructions