2Mounting Instruction BAT-ANT-Protector m-f
Release
03
01/13
General instructions
If exposed to extreme environmental conditions, especially icy conditions
or a polluted atmosphere, the connectors should be covered with a self-
vulcanizing tape or a cold shrink tube.
Disclaimer
All pertinent country, state, regional, and local safety regulations must be
observed when installing and using this product. For reasons of safety
and to help ensure compliance with documented system data, only the
manufacturer should perform repairs to components. This equipment
must only be installed and serviced by qualified personnel.
Device description
The BAT-ANT-Protector m-f is recommended for protecting the interior
electronics of BAT devices with outdoor antennas.
Despite outer over voltage protection measures, partial discharges can
still cause over voltages that can damage BAT devices. The BAT-ANT-
Protector m-f should be mounted as close as possible to the BAT device.
BAT-ANT-Protector m-f connectors
The BAT-ANT-Protector m-f provides two connectors, one for connecting
to the access point and one for connecting to the antenna (see fig. 1).
Figure 1: BAT-ANT-Protector m-f connectors
1 - N connector for connection to the antenna (unprotected area)
2 - N socket for connection to the access point (protected end marked in
red)
Connecting to the access point
To connect the BAT-ANT-Protector m-f to the access point proceed as
follows:
Connect one end of the adapter cable supplied with the antenna to the
N connector of the BAT-ANT-Protector m-f.
Connect the other end of the adapter cable to the antenna output of
the access point.