9
70103-00001D - 03/08 - Subject to change. © Belimo Aircontrols (USA), Inc.
F7…HSU Series Butterfly Valves
Resilient Seat 304 Stainless Disc with SY Series Electric Actuation
Maximum dimensions, measured in inches
MAX # Close-Off
Valve Size GPM A B,C D(Max) BHC Holes Lug Bolt Actuator Pressure (psi)
F750HSU 2” 118 4.50 6.15 15.50 4.75 4 ⁵⁄₈ - 11 UNCX1.25 SY1… 50
F765HSU 2½” 184 5.00 6.76 16.00 5.50 4 ⁵⁄₈ - 11 UNCX1.37 SY1… 50
F780HSU 3” 264 5.50 7.28 21.00 6.00 4 ⁵⁄₈ - 11 UNCX1.37 SY2… 50
F7100HSU 4” 470 6.50 8.55 21.75 7.50 8 ⁵⁄₈ -11 UNCX1.50 SY2… 50
F7125HSU 5” 734 7.50 9.64 22.25 8.50 8 ³⁄₄ -10 UNCX1.75 SY2… 50
F7150HSU 6” 1058 8.00 10.19 22.75 9.50 8 ³⁄₄ -10 UNCX2.00 SY2… 50
F7200HSU 8” 1880 9.00 11.37 24.25 11.75 8 ³⁄₄ -10 UNCX2.13 SY3… 50
F7250HSU 10” 2938 11.00 13.58 30.00 14.25 12 ⁷⁄₈ - 9 UNCX2.25 SY4… 50
F7300HSU 12” 4230 12.00 15.01 32.00 17.00 12 ⁷⁄₈ - 9 UNCX2.25 SY4… 50
Dimension “A” is compressed, add .125” for relaxed state. Maximum actuator ambient temperature is 150°F.
Model SY1… does not have hand wheel - override is via 8mm wrench on bottom side of actuator.
Application Notes:
1.Valves are rated at 200 psig differential pressure in the closed position, (150 psi 14” and larger).
2.Valves are furnished with lugs tapped for use with ANSI Class 125/150 flanges.
Installation flanges and hardware are not included.
3.3-way assemblies are furnished assembled and tested, ready for installation. All 3-way assemblies require the customer to specify
the 3-way configuration prior to order entry to guarantee correct placement of valves and actuators on the assembly.
4.Dimension “D” allows for actuator removal without the need to remove the valve from the pipe.
5.Belimo SY Series actuators are NEMA 4, 4x rated.
6.Bolts supplied are for shipping purposes only. Upon installation, replace with an appropriate SAE grade 5 or better hardware.
F7…HS Series Butterfly Valves
Full rated, Resilient Seat 304 Stainless Disc with Belimo SY Series Electric Actuation
Maximum dimensions, measured in inches
MAX # Close-Off
Valve Size GPM A B,C D(Max) BHC Holes Lug Bolt Actuator Pressure (psi)
F750HS 2” 118 4.50 6.15 20.25 4.75 4 ⁵⁄₈ -11 UNCX1.25 SY2… 200
F765HS 2½” 184 5.00 6.76 20.75 5.50 4 ⁵⁄₈ -11 UNCX1.37 SY2… 200
F780HS 3” 264 5.50 7.28 21.00 6.00 4 ⁵⁄₈ -11 UNCX1.37 SY2… 200
F7100HS 4” 470 6.50 8.55 21.75 7.50 8 ⁵⁄₈ -11 UNCX1.50 SY2… 200
F7125HS 5” 734 7.50 9.66 22.25 8.50 8 ³⁄₄ -10 UNCX1.75 SY3… 200
F7150HS 6” 1058 8.00 10.19 22.75 9.50 8 ³⁄₄ -10 UNCX2.00 SY3… 200
F7200HS 8” 1880 9.00 11.37 29.00 11.75 8 ³⁄₄ -10 UNCX2.13 SY4… 200
F7250HS 10” 2938 11.00 13.58 30.00 14.25 12 ⁷⁄₈ - 9 UNCX2.25 SY4… 200
F7300HS 12” 4230 12.00 15.01 32.00 17.00 12 ⁷⁄₈ - 9 UNCX2.25 SY5… 200
F7350HS 14” 5758 14.00 17.02 33.00 18.75 12 1 - 8 UNCX2.25 SY6… 150
F7400HS 16” 7520 15.00 18.39 38.50 21.25 16 1 - 8 UNCX3.38 SY7… 150
F7450HS 18” 9518 16.50 20.63 39.50 22.75 16 1¹⁄₈ - 7 UNCX4 SY9… 150
F7500HS 20” 11750 18.00 23.00 41.50 25.00 20 1¹⁄₈ - 7 UNCX5 SY9… 150
F7600HS 24” 16921 22.00 27.9 53.25 29.50 20 1¹⁄₄ - 7 UNCX5 SY12… 150
Dimension “A” is compressed, add .125” for relaxed state. SY6 and larger available in 110/220 VAC versions only.
Maximum actuator ambient temperature is 150°F.
Application Notes:
1.Valves are rated at 200 psig differential pressure in the closed position, (150 psi 14” and larger).
2.Valves are furnished with lugs tapped for use with ANSI Class 125/150 flanges.
Installation flanges and hardware are not included.
3.3-way assemblies are furnished assembled and tested, ready for installation. All 3-way assemblies require the customer to specify
the 3-way configuration prior to order entry to guarantee correct placement of valves and actuators on the assembly.
4.Dimension “D” allows for actuator removal without the need to remove the valve from the pipe.
5.Belimo SY Series actuators are NEMA 4, 4x rated.
6.Bolts supplied are for shipping purposes only. Upon installation, replace with an appropriate SAE grade 5 or better hardware.