Bellcome Touch Line Series User manual

1 Fam. Video 2 Fam. Video
3 Fam. Video 5 Fam. Video
EN
4 Wires
VIDEO OUTDOOR PANELS
(1 – 5 Families)
for TL door phone systems
User manual

VPA.1FR02 VPA.2FR02 VPA.1SR02 VPA.2SR02
= 12 … 14 Vd.c.
+U
Acces – card RFID
FLUSH mounting SURFACE mounting
294 x 144 x 53 mm
1,52 kg
260 x 110 x 33 mm
1,3 kg
VPA.5FR02VPA.3FR02 VPA.5SR02VPA.3SR02
1Safety instructions
2Description of the video outdoor panels
EN
EN
Any intervention on the installation must be performed by AUTHORIZED PERSONNEL!
DO NOT power the product at 110 – 230 Va.c.!
DO NOT hit the glass screen with hard objects!
If the glass screen is broken, DO NOT touch the product.
Protect the products against lime and dust during renovation activities.
EN
1
0ContentsEN
1Safety instructions
2Description of the video outdoor panels
4Installation of the Video Outdoor Panel
5Use of the video outdoor panels
3Recommended cables. Installation.
6Maintenance of the video outdoor panels
7Warranty

EN
2
3Recommended cables. Installation.
EN
2
Option 1) 4 wires x 0.5 mm (type H03VV-F4G 0.5) for maximum 75 m or another type of equivalent cable
2
4 wires x 0.75 mm (type H05VV-F4G 0.75) for maximum 100 m or another type of equivalent cable
*Important:
+U C/D GND Vin/VoutMaintain the same colors for the same connections. Example: = Red, = Blue, = Black, = Green.
For electrical security reasons, connect the terminal to an earth grounding.
Option 2) UTP cat5e (AWG24) or UTP cat6e (AWG23) or TCYY - 4x2x0.5-24 AWG (max. 100m)
for maximum 250 m. The wires will be arranged as per the below table:
+U
C/D
6mm
20-25mm
GND
Vin
+U
C/D
6mm 20-25mm
GND
Vout
Generally, any type of 4-wire cable with a 0.5 mm section is accepted. Telephone cables type TCYY - 2x2x0.5-24 AWG
(max. 30m); TCYY - 3x2x0.5-24 AWG (max. 50m); can also be used.
4Installation of the advanced Video Outdoor Panel (VPA)EN
STEP 1
+U
C/D
GND
20-25mm
6mm
Vin
+U
C/D
GND
20-25mm
6mm
Vout
Wall installation height
o
70
175 cm
130 cm
115 cm
160 cm-170cm
o
20
o
50
Case: aluminum + 4 mm chemically toughened glass
70º ± 25º orientable video camera
CMOS, 1/3", 573(H) x 597(V), 800 TVL video 1 Vpp / 75 W; PAL
IR LEDs, 850 nm, IR-CUT for night vision - 10m
TOUCH keys for call and family name, backlighted during night
Wall mounting height: 160 cm-170 cm
Weatherproof, waterproof and with an operating temperature range between -30ºC …+ 60ºC.
Electronic anti-condensation system for the video camera screen.
Anti-theft sensor that is activated during unauthorized unmounting from the wall.
Blinking red LED, signaling the presence of potential video monitoring from the panel.
In-built RFID reader. Access by secured RFID tag/card.
Allows the connection of a DVR, for extended monitoring and video recording from the panel.

Mounting on the wall - Surface
STEP 2
≈20cm
1.5
cm
STEP 4
Video camera angle adjustment. (The video camera will be oriented towards the entrance door/gate!)
JP 1 - Signaling of video monitoring: RED LED ON.
Unmount the module and add name labels
STEP 3.1
STEP 3.2
Mount back the family name module
STEP 2
Mounting on the wall - Flush
5cm ≈20cm
JP 2 - Setting of image recording on: DVR: DVR ON.
o
70 o
+25
o
+25
o
25
o
25
o
30
o
70
OFF ON
GNV
Vout
GND
C/D
+U
OFFON
DVR
RED LED
OFFON
DVR
OFF ON
RED LED
o
120
o
30
EN
3

GNV will not be connected!
Torx
Flush
Torx
Electrical connections diagram for the advanced Video Outdoor Panel (VPA)
Electrical connections in the panel
Torx
Mounting the outdoor panel on the wall
Surface
Important: For both types of mounting, the Torx screws for fastening the outdoor panels on the
wall will be very well tightened, to prevent the anti-theft alarm sensor from setting off.
4.1 EN
STEP 1STEP 1.1
+U
C/D
GND
Vout
Vout
+U
C/D
GND
GNV
GNV
EN
4

+U
C/D
GND
Vout
+U
C/D
GND
Vout
Electrical connections diagram for 1 and 2-family residences
4.2 EN
Note: Any type of TL terminal can be mounted indoors.
For Fam. 1, the terminal has address 1, which is set by the producer.
The additional terminals mounted in parallel will have the address of the main terminal
For Fam. 2, the terminal will be programmed with address 2. See Ch. 6
of the user manual for TL audio-video terminals.
Note: For residences with 1 family and one entrance (entrance 1),
the outdoor panel has address 1, which is set by the producer.
For multiple entrances: Entrance 2, Entrance 3, Entrance 4, panels
2, 3 and 4 will be programmed according to the procedure in Ch. 4.6.
EN
5Vout2
GNV
GND
+U
VPA (address 1)
Fam 1
Fam. 1
(address 1)
GONG2
GONG1
DBL1
DBL2
Doorbell
+U
C/D
GND
Vin
GONG
SCU
+U
PROG
BAT 110/230V
OUT1
AUX
,
Vcam
Vout2
GNV
GND
+U
SCU
+U
PROG
BAT 110/230V
OUT1
AUX
,
Vcam
Fam. 2 (address 2)
GONG2
GONG1
DBL1
DBL2
Doorbell
+U
C/D
GND
Vin
GONG
Fam. 1 (address 1)
GONG2
GONG1
DBL1
DBL2
Doorbell
+U
C/D
GND
Vin
GONG
OUT2
VPA (address 1)
+U
C/D
GND
Vout
Fam 2
Fam 1
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
+U
C/D
GND
Vout
LOCK
SUPPLY
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
+U
C/D
GND
Vout
LOCK
SUPPLY
+
-
max. 42Ah/12V
BAT
+
-
max. 42Ah/12V
BAT

Note: For residences with 3 families and one entrance (entrance 1),
the outdoor panel has address 1, which is set by the producer.
For multiple entrances: Entrance 2, Entrance 3, Entrance 4, panels 2, 3
and 4 will be programmed according to the procedure in Ch. 4.6.
Note: Any type of TL terminal can be mounted indoors.
For Fam. 1, the terminal has address 1, which is set by the producer.
The additional terminals mounted in parallel will have the address of the
main terminal
For Fam. 2 and Fam. 3, the terminal will be programmed with address 2,
respectively address 3. See Ch. 6 of the user manual for TL audio-video
terminals.
Electrical connections diagram for 3-family residences
EN
6
4.3 EN
+U
C/D
GND
Vin
GONG 2
GONG 1
DBL 1
DBL 2
Doorbell
GONG 2
GONG 1
DBL 1
DBL 2
Doorbell
+U
C/D
GND
Vin
Fam. 3
(address 3)
Fam. 2
(address 2)
GONG
GONG
Vout2
GNV
GND
+U
SCU
+U
PROG
BAT 110/230V
OUT1
Vcam
OUT2 OUT3
VPA (address 1)
GONG 2
GONG 1
DBL 1
DBL 2
Doorbell
+U
C/D
GND
Vin
Fam. 1
(address 1)
GONG
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
Fam 2
Fam 1
Fam 3
AUX
,BAT
+
-
max. 42Ah/12V
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
LOCK
SUPPLY
+U
C/D
GND
Vout

Electrical connections diagram for 5-family residences
EN
7
Note: Any type of TL terminal can be mounted indoors..
For Fam. 1, the terminal has address 1, which is set
by the producer.
The additional terminals mounted in parallel will have the
address of the main terminal
For Fam. 2, 3, 4 and 5, the terminal will be programmed with
address 2, respectively addresses 3, 4 and 5. See Ch. 6
of the user manual for TL audio-video terminals.
Note: For residences with 5 families and one entrance (entrance 1),
the outdoor panel has address 1, which is set by the producer.
For multiple entrances: Entrance 2, Entrance 3, Entrance 4,
panels 2, 3 and 4 will be programmed according to the
procedure in Ch. 4.6.
4.4 EN
OUT 4
OUT 2
OUT 3
OUT 1
OUT
IN
VCB
GONG
GONG
GONG
+U
C/D
GND
Vout
Doorbell
GONG 2
GONG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
Doorbell
Fam. 4 (address 4)
GONG 2
GONG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
Doorbell
GONG 2
GONG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
+U
C/D
GND
Vin
Doorbell
GONG 2
GONG 1
DBL 1
DBL 2
GONG
Fam. 5 (address 5)
Fam. 3 (address 3)
Fam. 1 (address 1)
GONG
Doorbell
GONG 2
GONG 1
DBL 1
DBL 2
+U
C/D
GND
Vin
Fam. 2 (address 2)
+U
C/D
GND
Vin
Vout2
GNV
GND
+U
VPA (address 1)
SCU
+U
PROG
BAT 110/230V
OUT1
+U
C/D
GND
Vout
Vcam
Fam 3
Fam 2
Fam 4
Fam 5
Fam 1
AUX
,BAT
+
-
max. 42Ah/12V
LCK
max. 24Va.c./24Vd.c.
EXIT
S1: 2x6Aa.c. 110Va.c./50Hz
230Va.c./50Hz
N
L
+U
C/D
GND
Vin
LOCK
SUPPLY
+U
C/D
GND
Vout

Electrical connections diagram for multiple parallel panels
(more entrances in a building)
EN
8
4.5 EN
To one or
more families
C/D
GND
Vout
+U
C/D
GND
Vout
+U
VPA1 (address 1)
110Va.c.
230Va.c.
+U
C/D
GND
Vin
VPA2 (address 2)
+U
C/D
GND
Vin
+U
C/D
GND
Vin
+U
C/D
GND
Vin
110Va.c.
230Va.c.
110Va.c.
230Va.c.
110Va.c.
230Va.c.
OUT 1
C/D
GND
Vout
+U
C/D
GND
Vin
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
SCU1 SCU2 SCU3 SCU4
VSB
OUT 1 OUT 1 OUT 1
12 3 4
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
C/D
GND
Vout
+U
VPA3 (address 3) VPA4 (address 4)
Important: One VPA outdoor panel and one SCU central unit will be mounted at each entrance.
The VPA1 panel keeps address 1, which is set from the factory.
The VPA2 panel with address 2 Long press the PROG. button at SCU 2 Long touch the Fam.1 key at the VPA2 panel.
long beep Short touch the Fam.1 key, twice Two short beeps confirmation.
The VPA3 panel with address 3 Long press the PROG. button at SCU 3 Long touch the Fam.1 key at the VPA3 panel.
long beep Short touch the Fam.1 key, three times Three short beeps confirmation.
The VPA4 panel with address 4 Long press the PROG. button at SCU 4 Long touch the Fam.1 key at the VPA4 panel.
long beep Short touch the Fam.1 key, four times Four short beeps confirmation.
Note: After the beep confirmation of the new address in the panel, go to the SCU of the panel and short press the
PROG. button. The programming of the address is finished.
The programming of the addresses for the panels connected in parallel is done as follows:
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5

Use of the Video Outdoor Panels
1. STAND-BY: The call keys with the name of the residents are permanently backlighted during night. The Red LED
blinks permanently.
2. CALL: Touch the key corresponding to the name of the family you are looking for. The call is acoustically signaled
with a ding-dong. Each touch of the key reinitiates the call.
4. END OF TALK: - After 1 min. from the call, if the resident does not answer.
- At 10 sec. after the door/gate is opened.
- Immediately, if the resident decides to end the talk without opening the door/gate.
3. TALK: If the resident answers, talk is initiated. The maximum duration of the talk is 2 min.
5. ACCESS: The door/gate will be open during the time set at the SCU (maximum 10 sec.). Access granting is
acoustically signaled through a confirmation beep sequence.
6. RFID CARD ACCESS: If you program the RFID cards in the outdoor panel, each resident of the building has
access using the secured RFID card from BELLCOME. Approach the card to the RFID area marked on the
outdoor panel. The access is signaled acoustically, through a confirmation beep sequence, and visually – the
symbol blinks white.
EN
9
At the moment of the delivery from the factory, the TL video outdoor panels do not have access cards memorized.
In order to have access in the building after installation, it is mandatory to program the RFID cards in the
outdoor panel.
During programming the installation has to be connected to the grid (110V/230Va.c.) and fully operational.
1. Go to the place where the SCU central unit of the installation is mounted. Long press (3 sec.) the PROG button on
the SCU. The Red LED turns on.
2. Take the RFID cards to the outdoor panels. To program them, approach every card for one second to the
RFID area of the outdoor panel. For each programmed card, the panel issues two short beeps. Repeat this step
for programming all the RFID cards.
3. Go to the place where the SCU central unit of the installation is mounted. Short press the PROG button on the SCU.
The Red LED turns off. The installation returns to normal functioning, successfully ending the programming mode.
Orientable video camera
RFID reader.
RFID tag/card access
Microphone
Fastening Torx screw
IR LEDs
(night lighting)
Touch keys for call,
with the name of the residents
Speaker
Fastening Torx screw
1 Fam. 5 Fam.
2 Fam., 3 Fam.
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 1
294 mm
274 mm
115 mm
145 mm
5EN
Deleting the RFID Cards from the panel
5.2 EN
This procedure applies when you wish to give up access with RFID cards. During the deletion of the RFID cards,
the installation has to be connected to the grid (110V/230Va.c.) and fully operational.
1. Go to the place where the SCU central unit of the installation is mounted. Long press (3 sec.) the PROG button on
the SCU. The Red LED turns on. The installation enters programming mode:
Note: The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the
name labels are added.
Manual programming of the RFID Cards in the panel/
Adding a new RFID Card in the panel.
5.1 EN

The Touch Line outdoor panels must be kept away from corrosive substances, lime and blows. In case of renovation activities,
the entire surface of the panels will be protected with plastic foil.
For cleaning the glass surfaces, use a clean cloth and a special solution for glass washing.
DO NOT undo the electrical connections of the video door phone installation components.
DO NOT short-circuit the electrical connections of the video door phone installation components.
a. Warranty is granted according to the current legislation in the buyer's country of residence, based on the purchase
documents.
b. Warranty is granted for the hidden defects of the components used in production and in case of the system not functioning
according to the present user manual.
WARRANTY IS NOT GRANTED FOR:
c. Inappropriate installation and use.
d. Deterioration, intentional blows.
e. Unauthorized interventions to any of the components of the installation
f. Theft, fire, natural disasters
g. Lack of protection of the installation components in case of renovation activities.
6Maintenance of the video outdoor panels
7Warranty
EN
EN EN
10
2. To delete the RFID access cards from the memory of the panel:
- Long touch the Fam. 1 key until the acoustic confirmation of the panel with a long beep.
- Short touch the Fam. 1 key 7 times. The panel issues two short confirmation beeps.
- Immediately after, long touch (2-3 sec.) the Fam. 1 key. All the codes of the RFID access cards are deleted
permanently. The action is acoustically confirmed by a long beep.
3. Go to the place where the SCU central unit of the installation is mounted. Short press the PROG button on the SCU.
The Red LED turns off. The installation returns to normal functioning mode.
4. Optional: From the outdoor panel, check if the old RFID cards grant access. When each RFID card that has
been deleted from the memory is approached to the panel, a low frequency beep will be issued.

06.2019 USM.VPA.5XR02.BLY04
ELECTRA s.r.l
Bd. Chimiei nr.8,Iași - 700291 - RO
www.electra.ro
ELECTRA
Bischoffgasse 5/3-4, 1120 Wien - AT
+43 1 810 20 99
www.bellcome.com
Building Communications GmbH
BELLCOME is a trademark of ELECTRA Group - No. 013502646 EUIPO - Alicante, Spain
BELLCOME is a trademark of ELECTRA Group - No. 1732510 MPI - Ciudad de Mexico, Mexico
ELECTRA is a trademark of ELECTRA Group - No. 008958332 EUIPO - Alicante, Spain
BELLCOME/ELECTRA products are registered as Industrial Models at EUIPO - Alicante, Spain
The products are
CE certified.
Certificate no. E307311
ISO 9001:2015
ISO 14001:2015
Certificates no. 73 100 4856, 73 104 4856
by TÜV HESSEN
The products are manufactured under
Quality and Environment Management System
R
The products contain UL-compliant
printed circuit boards.
Certificate by
R709 ICPE
Designed and produced by ELECTRA Made in EU
This manual suits for next models
8
Table of contents
Other Bellcome Intercom System manuals

Bellcome
Bellcome Touch Line VPA.1FR03.BLB04 User manual

Bellcome
Bellcome VPA.1FR02 User manual

Bellcome
Bellcome 2 smart User manual

Bellcome
Bellcome KIT Audio 3 families User manual

Bellcome
Bellcome Touch Line VPA.1FR03.BLB04 User manual

Bellcome
Bellcome advanced 2 families User manual

Bellcome
Bellcome Touch Line Smart+ Series User manual
Popular Intercom System manuals by other brands

Security Brands
Security Brands RIDGE 2.0 quick start guide

SSS Siedle
SSS Siedle IQ HTS Operating instructions for end users

2N
2N Helios IP installation manual

DeltaFrontier
DeltaFrontier OS-M385C2-V-R23WF-TEMPF Product Booklet

3M
3M D-2475 operating instructions

Aiphone
Aiphone MK-DS Installation and operation manual