manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bellcome
  6. •
  7. Intercom System
  8. •
  9. Bellcome Touch Line VPA.1FR03.BLB04 User manual

Bellcome Touch Line VPA.1FR03.BLB04 User manual

advanced 1 Fam. advanced 2 Fam.
EN
USER MANUAL
Video outdoor panels
1 – 5 Families
door system4 WIRE
advanced 3 Fam. advanced 5 Fam.
1Safety instructions
2Description of the Touch Line video panels
DO NOT power the product at 110 – 230 Va.c.!
DO NOT hit the glass screen with hard objects!
If the glass screen is broken, DO NOT touch the product.
Protect the products against lime and dust during renovation activities.
= 12 … 14 Vd.c.
U
Acces – RFID card
FLUSH mounting SURFACE mounting
294 x 144 x 53 mm
1,52 kg
260 x 110 x 33 mm
1,3 kg
0Contents
1Safety instructions
2Description of the Touch Line video panels
4Connection diagrams for 1 – 5 Families
5Connection of additional panels
3Recommended cables.
Installation of the Touch Line video panels.
6Connection of additional video cameras
7Programming and deleting the RFID cards
8Maintenance
9Declaration of conformity. Warranty.
Aluminium case + chemically toughened glass
EN
12.1 Technical data
VPA.1FR03.BLB(W)04 VPA.2FR03.BLB(W)04 VPA.1SR03.BLB(W)04 VPA.2SR03.BLB(W)04
VPA.5FR03.BLB(W)04VPA.3FR03.BLB(W)04 VPA.5SR03.BLB(W)04VPA.3SR03.BLB(W)04
*B = Black; W = White
EN
2
3Recommended cables. Installation of the Touch Line video panels
3.1 Recommended cables
2
4 wires x 0.5 mm (type H03VV-F4G 0.5) for maximum 60 ml or another type of equivalent cable;
2
4 wires x 0.75 mm (type H05VV-F4G 0.75) for maximum 150 ml or another type of equivalent cable;
Generally, any type of 4-wire cable with a 0.5 mm section is accepted. Telephone cables type TCYY -
2x2x0.5-24 AWG (max. 30 ml); TCYY -3x2x0.5-24 AWG (max. 50 ml); TCYY - 4x2x0.5-24 AWG (max. 50 ml)
can also be used.
Note: If the cable has more than 4 wires, the additional wires will be connected the same as in the case of
a UTP cable. The +14 and GND connections are equally supplemented with the additional wires.
4 WIRE Installation (standard)
+14
C/D
6mm
20-25mm
GND
Vin
+14
C/D
6mm 20-25mm
GND
Vout
SCU
Panel
2.2 Use
Orientable video camera
RFID reader
Microphone
Fastening Torx screw
LEDs (day and night white lighting)
Touch key with the name
of the family
Speaker
Fastening Torx screw
1 Fam. 5 Fam.
2 Fam., 3 Fam.
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 1
Presence sensors
LEDs signaling status during use
1. STAND-BY. The keys with the names of the residents are off. The red LED blinks and signals the possibility of
video monitoring.
Note: The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the name
labels are added.
2. CALL + TALK + ACCESS. The keyboard turns on when a person approaches the panel less than 1m away. Touch
the key corresponding to the name of the family you are looking for. The panel signals the call acoustically, with a beep
sequence and visually – video camera LEDs and LED on.
The call lasts max. 1 min. Each touch of the key reinitiates the call.
If the resident answers, the talk mode is activated – LED on. The conversation is hands-free, with a duration of
max. 2 min. If the resident grants the access, it is commanded the opening of the door/ gate and the panel signals
acoustically, with a confirmation beep sequence and visually – LED on.
The door/ gate remains open max. 8 sec.
3. RFID card ACCESS. Approach the RFID card to the area marked with the symbol. It is commanded the opening of
the door/ gate and the panel signals acoustically, with a confirmation beep sequence and visually – LED on.
The door/ gate remains open max. 8 sec.
≈20cm
UTP Cable Installation
For distances between 150 ml and 250 ml it is mandatory to use the twisted pair cable type
UTP/ FTP cat5e (AWG24) or UTP/ FTP cat6 (AWG23).
SCU
+14
C/D
GND
20-25mm
6mm
Vin
+14
C/D
GND
20-25mm
6mm
Vout
Panel
EN
3
Mounting on the wall - Flush
Mounting on the wall - Surface
50mm
120mm
280mm
4mm 50mm
33mm
Unmount the module and add name labels Mount back the family name module.
o
90 o
90 o
-20
o
90
130 cm-160cm
175 cm
130 cm
115 cm
o
90
130 cm-160cm
175 cm
130 cm
115 cm
o
-20
o
90
130 cm-160cm
175 cm
130 cm
115 cm
o
+10
1
o
90
o
+20
Orientation of the video camera
o
45 o
45 o
25
o
65 o
65
o
25
1
23
4 5
EN
4
Torx
Flush
Torx
Electrical connections in the panel
Torx
Mounting the outdoor panel on the wall
Surface
Important: For both types of mounting, the Torx screws for fastening the outdoor panels on the
wall will be very well tightened, to prevent the anti-theft alarm sensor from setting off.
Step 5Step 6
+14
C/D
GND
Vout
Vout
+14
C/D
GND
EN
5
Connection diagrams for 1 – 5 Families
4
EN
6
1 Family
2 Families
Note: Any type of TL terminal can be mounted indoors.
For Fam. 1, the terminal has address 1, which is set by the producer.
The additional terminals mounted in parallel will have the address of the main terminal.
For Fam. 2, the terminal will be programmed with address 2.
See the manual of the TL audio-video terminals.
+14
C/D
GND
Vout
+14
C/D
GND
Vin1
+14
C/D
GND
Vout1
OUTDOOR
EXT1
EXT2
LCK1
LCK2
-
+
110/230Va.c.
50/60Hz
GROUNDED OUTLET
Fam. 1(Address 1)
+14
C/D
GND
Vin
LOCK
SUPPLY
EXIT
LOCK
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
Outdoor Panel
INDOOR
AUX1
Vcam
AUX2max.12Ah/12V
+
-
BAT
Outdoor Panel
+14
C/D
GND
Vout
+14
C/D
GND
Vin1
+14
C/D
GND
Vout1
OUTDOOR
EXT1
EXT2
LCK1
LCK2
-
+
110/230Va.c.
50/60Hz
GROUNDED OUTLET
LOCK
SUPPLY
EXIT
LOCK
INDOOR
AUX1
Vcam
AUX2max.12Ah/12V
+
-
BAT
3
+14
C/D
GND
Vin1
EXIT
EXIT
-
~
+
~
LCK1
LCK2
+14
GND
Vin2
AUX1
AUX2
+BAT
-BAT
+14
C/D
GND
Vout1
+14
C/D
GND
Vout2
+14
C/D
GND
Vout3
SCU.VDR03.BLG14
GND
Vin2
+12
OTHER VIDEO
AUX 1
AUX 1
AUX 2
AUX 2
+BAT
-BAT
+14
C/D
GND
Vout1
C/D
GND
Vout2
+14
C/D
GND
Vout3
OUT2OUT3
AUX1 AUX2 BAT OUT1
+14
GNV
GNV
~
~
3
+14
C/D
GND
Vin1
EXIT
EXIT
-
~
+
~
LCK1
LCK2
SCU.VDR03.BLG34
+14
GND
Vin2
+12
OTHER VIDEO
AUX 1
AUX 1
AUX 2
AUX 2
+BAT
-BAT
+14
C/D
GND
Vout1
+14
C/D
GND
Vout2
+14
C/D
GND
Vout3
OUT2OUT3
AUX1 AUX2 BAT OUT1
VIDEO DOOR PANEL
+14
C/D
GND
Vout
Fam. 2(Address 2)
+14
C/D
GND
Vin
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
Fam. 1(Address 1)
+14
C/D
GND
Vin
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
~
~
3
+14
C/D
GND
Vin1
EXIT
EXIT
-
~
+
~
LCK1
LCK2
SCU.VDR03.BLG34
+14
GND
Vin2
+12
OTHER VIDEO
AUX 1
AUX 1
AUX 2
AUX 2
+BAT
-BAT
+14
C/D
GND
Vout1
+14
C/D
GND
Vout2
+14
C/D
GND
Vout3
OUT2OUT3
AUX1 AUX2 BAT OUT1
VIDEO DOOR PANEL
3 Families
Note: Any type of TL terminal can be mounted indoors.
For Fam. 1, the terminal has address 1, which is set by the producer.
The additional terminals mounted in parallel will have the address of the main terminal.
For Fam. 2 and Fam. 3, the terminal will be programmed with address 2, respectively address 3. See the manual of the TL audio-video terminals.
+14
C/D
GND
Vout
+14
C/D
GND
Vin1
+14
C/D
GND
Vout1
OUTDOOR INDOOR
EXT1
EXT2
+14
C/D
GND
Vout
+14
C/D
GND
Vout
LCK1
LCK2
-
+
110/230Va.c.
50/60Hz
GROUNDED
OUTLET Fam. 3(Address 3)
+14
C/D
GND
Vin
Fam. 2(Address 2)
+14
C/D
GND
Vin
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
Fam. 1(Address 1)
+14
C/D
GND
Vin
LOCK
SUPPLY
EXIT
LOCK
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
Outdoor Panel
AUX1
Vcam
AUX2max.12Ah/12V
+
-
BAT
EN
7
3
+14
C/D
GND
Vin1
EXIT
EXIT
-
~
+
~
LCK1
LCK2
+14
GND
Vin2
AUX1
AUX2
+BAT
-BAT
+14
C/D
GND
Vout1
+14
C/D
GND
Vout2
+14
C/D
GND
Vout3
SCU.VDR03.BLG14
GND
Vin2
+12
OTHER VIDEO
AUX 1
AUX 1
AUX 2
AUX 2
+BAT
-BAT
+14
C/D
GND
Vout1
C/D
GND
Vout2
+14
C/D
GND
Vout3
OUT2OUT3
AUX1 AUX2 BAT OUT1
+14
GNV
GNV
5 Families
Note: Any type of TL terminal can be mounted indoors..
For Fam. 1, the terminal has address 1, which is set by the producer.
The additional terminals mounted in parallel will have the address of the main terminal.
For Fam. 2, 3, 4 and 5, the terminal will be programmed with address 2, respectively addresses 3, 4 and 5.
See the manual of the TL audio-video terminals.
EN
8
Fam. 5(Address 5)
+14
C/D
GND
Vin
Fam. 3(Address 3)
+14
C/D
GND
Vin
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
Fam. 2(Address 2)
+14
C/D
GND
Vin
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
Fam. 1(Address 1)
+14
C/D
GND
Vin
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
Fam. 4(Address 4)
+14
C/D
GND
Vin
GNG+
GNG-
DBL1
DBL2
Doorbell GONG
OUT 4
OUT 2
OUT 3
OUT 1
OUT
IN
VCB
+14
C/D
GND
Vout
+14
C/D
GND
Vin
+14
C/D
GND
Vout
+14
C/D
GND
Vin1
+14
C/D
GND
Vout1
OUTDOOR INDOOR
EXT1
EXT2
LCK1
LCK2
-
+
110/230Va.c.
50/60Hz
GROUNDED
OUTLET
LOCK
SUPPLY
EXIT
LOCK
Outdoor Panel
AUX1
Vcam
AUX2max.12Ah/12V
+
-
BAT
Connection of additional panels
5
To one or
more families
C/D
GND
Vout
+14
C/D
GND
Vout
+14
VPA1 (address 1)
110Va.c.
230Va.c.
+14
C/D
GND
Vin
VPA2 (address 2)
+14
C/D
GND
Vin
+14
C/D
GND
Vin
+14
C/D
GND
Vin
110Va.c.
230Va.c.
110Va.c.
230Va.c.
110Va.c.
230Va.c.
C/D
GND
Vout
+14
C/D
GND
Vin
+14
C/D
GND
Vout
+14
C/D
GND
Vout
+14
VSB
12 3 4
C/D
GND
Vout
+14
C/D
GND
Vout
+14
C/D
GND
Vout
+14
C/D
GND
Vout
+14
VPA3 (address 3) VPA4 (address 4)
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
Important: One VPA video panel and one SCU central unit will be mounted at each entrance.
EN
9
The programming of the addresses for the panels connected in parallel is done as follows:
a. The VPA1 panel keeps address 1, which is set from the factory.
b. The VPA2 panel with address 2:
Step 1 Long press the PROG button at SCU2 The red LED turns on.
Step 2 Long touch the Fam.1 key at the VPA2 panel Long beep.
Step 3 Short touch the Fam.1 key, twice Two short beeps confirmation.
Step 4 Short touch the PROG button at SCU2 to exit programming mode The red LED turns off.
c. The VPA3 panel with address 3:
Step 1 Long press the PROG button at SCU3 The red LED turns on.
Step 2 Long touch the Fam.1 key at the VPA3 panel Long beep.
Step 3 Short touch the Fam.1 key, three times Three short beeps confirmation.
Step 4 Short touch the PROG button at SCU3 to exit programming mode The red LED turns off.
d. The VPA4 panel with address 4:
Step 1 Long press the PROG button at SCU4 The red LED turns on.
Step 2 Long touch the Fam.1 key at the VPA4 panel Long beep.
Step 3 Short touch the Fam.1 key, four times Four short beeps confirmation.
Step 4 Short touch the PROG button at SCU4 to exit programming mode The red LED turns off.
SCU1 SCU2 SCU3 SCU4
Programming and deleting the RFID cards
7
7.1Manual programming of the RFID cards
When delivered from the factory, the Touch Line video panels do not have access cards memorized.
In order to have access in the building after installation, it is mandatory to program the RFID cards in the video panel as follows:
The entire video door phone system is installed and set under tension.
Go to the place where the SCU central unit of the installation is mounted.
Long press (2-3 sec.) the PROG button The red LED turns on.
Return to the video panel with the RFID cards.
To program them, approach every card for one second to the RFID area of the video panel.
For each programmed card, the panel issues two short beeps.
Repeat this step for programming all the RFID cards.
Go back to the place where the SCU central unit of the installation is mounted.
Short touch the PROG button to exit programming mode The red LED turns off.
0
1
2
3
Note: Use the same procedure for programming additional RFID cards.
7.2Deleting the RFID cards
The entire video door phone system is installed and set under tension.
Go to the place where the SCU central unit of the installation is mounted.
Long press (2-3 sec.) the PROG button The red LED turns on.
0
1
2
3 Go back to the place where the SCU central unit of the installation is mounted.
Short touch the PROG button to exit programming mode The red LED turns off.
Return to the video panel and:
- Long touch the Fam. 1 key Long beep.
- Short touch the Fam. 1 key seven times Two short beeps confirmation.
- Immediately after, long touch (2-3 sec.) the Fam. 1 key All the codes of the RFID access cards are deleted
permanently. The action is acoustically confirmed by a long beep.
EN
10
Connection of additional cameras
6
+14
C/D
GND
Vin
C/D
GND
Vout
+14
SCU
PROG
OUT1
+14
SCU.VDR03.BLG34
VSB
SCU
C/D
GND
Vout
+14
Outdoor Panel
Video
selection
box
The Touch Line outdoor panels must be kept away from corrosive substances, lime and blows.
For cleaning the glass screens, use a clean cloth and a solution for glass washing.
In case of renovation activities, the Touch Line video door system components must be completely protected with plastic foil.
DO NOT undo the electrical connections of the Touch Line video door system components.
DO NOT short-circuit the electrical connections of the Touch Line video door system components.
The manufacturer ELECTRA s.r.l. declares that:
The products are in compliance with the harmonised legislation of the European Union regarding the directives:
Low Voltage (LVD) 2014/35; Electromagnetic compatibility (EMC) 2014/30/EC; RoHS 2011/65/EC.
The following harmonised standards and technical specifications have been applied: SR EN 60950-1:2006 + A1:2011
+ A2:2014 + A11:2009 + A12:2014 + AC:2011 + C91:2010; SR EN 55022:2011 + AC:2011; SR EN 55024:2011 + A1:2015;
SR EN 61000-3-2 2015; SR EN 61000-3-3:2014.
The products do not threaten life, health, work safety, do not have any negative effect on the environment and have been
produced under the ISO 9001:2015/ ISO 14001:2015 Quality and Environment Management System certified by
TÜV HESSEN.
Warranty
1. A 24-month warranty is granted, according to the existing legislation, based on the purchase document.
2. Warranty is granted for non-conformity and/or hidden defects.
3. Warranty is NOT granted for:
- Missing purchase documents;
- Incorrect installation, non-compliant with this manual (e.g.: wrong supply voltage);
- Incorrect operation, non-compliant with this manual (e.g.: wrong settings);
- Broken glass and/or other damage, blows, mechanical shocks;
- Theft, fire, floods, natural disasters;
- Unprotected product during renovation activities;
- Use of the product in systems that require different performance parameters from the ones provided by the technical
specifications in this manual;
- The RFID access cards (tags), which are considered consumables.
4. For complaints during the warranty period, please contact the company from which you have purchased the product.
9Declaration of conformity. Warranty.
8Maintenance
EN
10
11.2020 USM.VPA.5XR03.BLY04
Certificate no. E307311
ISO 9001:2015
ISO 14001:2015
Certificates no. 73 100 4856, 73 104 4856
by TÜV HESSEN
The products are manufactured under
Quality and Environment Management System
The products are
CE certified.
R
The products contain UL-compliant
printed circuit boards.
Certificate by
R709 ICPE
BELLCOME is a trademark of ELECTRA Group - No. 013502646 - EUIPO - Alicante, Spain
BELLCOME/ELECTRA products are registered as Industrial Models - EUIPO - Alicante, Spain
Designed and produced by ELECTRA
SUPPORT
ELECTRA Building Communications GmbH
Bischoffgasse 5/3-4,
1120 Wien - AT
+43 1 810 20 99
[email protected]
www.bellcome.com
MADE in EU by:
ELECTRA s.r.l
Parc Industrial Miroslava
Str. Principala 33, 707307, Jud. Iași - RO
+40 232 214.370
[email protected]
www.electra.ro

Other manuals for Touch Line VPA.1FR03.BLB04

1

This manual suits for next models

15

Other Bellcome Intercom System manuals

Bellcome Touch Line VPA.1FR03.BLB04 User manual

Bellcome

Bellcome Touch Line VPA.1FR03.BLB04 User manual

Bellcome advanced 2 families User manual

Bellcome

Bellcome advanced 2 families User manual

Bellcome VPA.1FR02 User manual

Bellcome

Bellcome VPA.1FR02 User manual

Bellcome Touch Line Smart+ Series User manual

Bellcome

Bellcome Touch Line Smart+ Series User manual

Bellcome Touch Line Series User manual

Bellcome

Bellcome Touch Line Series User manual

Bellcome KIT Audio 3 families User manual

Bellcome

Bellcome KIT Audio 3 families User manual

Bellcome 2 smart User manual

Bellcome

Bellcome 2 smart User manual

Popular Intercom System manuals by other brands

Vimar Elvox 3301 Mounting instructions

Vimar

Vimar Elvox 3301 Mounting instructions

Panasonic VL-V591 Installation and operation guide

Panasonic

Panasonic VL-V591 Installation and operation guide

Bpt HEP/306 installation instructions

Bpt

Bpt HEP/306 installation instructions

Bticino Polyx Memory Display installation manual

Bticino

Bticino Polyx Memory Display installation manual

XtendLan DPM-451 user manual

XtendLan

XtendLan DPM-451 user manual

CAME BPT THANGRAM Programming manual

CAME BPT

CAME BPT THANGRAM Programming manual

Security Brands 25-C2 quick start guide

Security Brands

Security Brands 25-C2 quick start guide

urmet domus VOG7 1760/31A User booklet

urmet domus

urmet domus VOG7 1760/31A User booklet

3M Signature Series operating instructions

3M

3M Signature Series operating instructions

Cocoon HE414114 Getting started guide

Cocoon

Cocoon HE414114 Getting started guide

fortessa FTDEV1P user manual

fortessa

fortessa FTDEV1P user manual

Aiphone AN-8050DS installation manual

Aiphone

Aiphone AN-8050DS installation manual

Comelit Genius Series Technical sheet

Comelit

Comelit Genius Series Technical sheet

Dahua DHI-VTO2000-A-2-S user manual

Dahua

Dahua DHI-VTO2000-A-2-S user manual

SSS Siedle Classic SET CLAB 850-1 Product information

SSS Siedle

SSS Siedle Classic SET CLAB 850-1 Product information

Commend SIP-WS 211V DA Short Reference

Commend

Commend SIP-WS 211V DA Short Reference

Mircom TX3 Series Installation and operation manual

Mircom

Mircom TX3 Series Installation and operation manual

Aiphone NEM-20 instructions

Aiphone

Aiphone NEM-20 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.