manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Benetech
  6. •
  7. Thermometer
  8. •
  9. Benetech GM900 User manual

Benetech GM900 User manual

MODEL: GM900
Infrared thermometer
Instruction manual
A. Introduction
This infrared thermometer is used for measuring
the temperature of the object's surface, which is
applicable for various hot, hazardous or hard to
reach objects without contact safely and quickly.
This unit consist of Optics, Temperature ensor
ignal amplifier, Processing circuit and LCD Display.
The Optics collected the infrared energy emitted by
object and focus onto the ensor. Then the sensor
translates the energy into an electricity signal. This
signal will be turned out to be digital shown on the
LCD after the signal amplifier and processing circuit.
B. Warning Cautions
1. Warning:
To avoid the potential situation may cause harm or
damage to people, please pay attention to the
following items:
1) Before you use this unit, check on the plastic
housing carefully. If there is any damage, do not
use it
2) Do not point laser directly at eye or indirectly off
reflective surfaces.
3) Do not use this unit in the environment of
explosive gas, steam or dusty.
2. Caution:
To avoid the damage of the unit or the target, please
protect from the following situations:
1) EMF (electro-magnetic fields) from arc welders, or
induction heaters.
2) Thermal shock caused by high temperature changes
allow 30 minutes for unit to stabilize before use.
3) Do not leave the unit on or near objects of high
temperature
2) Field of view: Make sure the target is larger than
the unit's spot size. The smaller the target the
closer measure distance. When accuracy is
critical, make sure the ta get is at least twice as
large as the spot size.
(Page 1) (Page 2) (Page 3)
C. Distance to Spot size
1) When take measurement, pay attention to the
D stance to pot ize. As the Distance (D)
from the target surface increases, the spot size
( ) of the area measured by the unit becomes
larger. The Distance to pot size of the unit is
12:1
***This unit is equipped with a laser, which is used for
aiming.
D. Emissivity
Emissivity, Most organic materials and painted or
oxidized surfaces have an emissivity of 0.95 (pre-set
in the unit). Inaccurate readings will result from
measuring shiny or polished metal surfaces. To
compensate, cover the target surface with masking
tape or flat black paint. Measure the tape or painted
surface when the tape or painted reach the same
temperature as the material underneath.
Material Emissivity Material Emissivity
Aluminum 0.3 Iron 0.70
Asbestos 0.95 Lead 0.5
Asphalt 0.95 Limestone 0.98
Basalt 0.70 Oil 0.94
Brass 0.5 Paint 0.93
Brick 0.90 Paper 0.95
Carbon 0.85 Plastic 0.95
Ceramic 0.95 Rubber 0.95
Concrete 0.95 and 0.90
Copper 0.95 kin 0.98
Dirt 0.94 now 0.90
Frozen food 0.90 teel 0.80
Hot food 0.93 Textiles 0.94
Glass(Plate) 0.85 Water 0.93
Ice 0.98 Wood 0..94
www.Tools.in.th
www.Tools.in.th
E. Operation
Operating the unit:
1) Open the battery door and insert a battery properly.
2) Pull the trigger to turn on the unit.
3) Aim at the target surface and pull the trigger, then
temperature will be shown on the L D. This unit is
equipped with a laser which is only used for aiming.
Locating a Hot Spot:
To find a hot spot, aim the thermometer outside of
interest, then scan across with an up and down motion
until you locate the hot spot. (Figure 3)
F. LCD display & Buttons
1. LCD display:
a) Measurement reading
b) Measurement unit
c) Laser on icon
d) Backlight on icon
e) Battery power icon
f) Scanning icon
g) Data hold icon
h) Mode emissivity indicator
i) Data storage / read icon
j) Low temperature icon
k) High temperature icon
1) Trigger: When turn on L D display VERXX software
version for 1 sec. And turn to display reading with
scan icon. Release the trigger, Display HOLD icon.
Built in auto power off in 30 sec.
2) Laser/Back light button: When back light turn on any
operation will remain back light for 10 sec. L D
indicate on/off status.
3) - 6) Key function: Press 3key. L D subdisplay blinks
MAX-MIN-DIF-AVG-HAL-LAL-STO-EMS segment
(Only main display means normal measuring mode)
press 4key to enter
G. Maintenance
1. Lens Cleaning: Blow off loose particles using
clean compressed air. Gently brush remaining
debris away with a moist cotton swab. The
swab may be moistened with water.
2. Case cleaning: lean the case with a damp
sponge/ cloth and mild soap.
Note:
1) 1) Do not use solvent to clean plastic lens.
2) 2) Do not submerge the unit in water.
. Specification
Temperature range -50 ~ 900 C (-58 ~ 1652 F)
Accuracy
0~900C (32 ~1652F)
±1.5C (± 2.7F ) or ±1.5%
-50~0C (-58~32F) ±3C ( ±5F )
Whichever is greater
Resolution 0.1C or 0.1F
Repeatability 1% of reading or 1C
Response time 500 mSec, 95% response
Spectral response 8-14 um
Emissivity 0.10~1.00 Adjustable (0.95Preset)
Distance to Spot size 12:1
Operating Temperature 0~ 40C (32 ~ 104F)
Operating umidity 10~95%R non-condensing up to
30C (86F)
Storage Temperature -20 ~ 60C (-4 ~ 140F)
Power 9V *1 Battery
Typical battery life
(Alkaline)
Non-laser mode: 22 hrs;
Laser Models:12 hrs
Weight 222g
Dimension 175x100x50mm
MADE IN CHINA
(Page 4) (Page 5) (Page 6)
Figure 2
2. Buttons: Figure 3
a) MAX: Measuring maximum temperature
b) MIN: Measuring minimum temperature
c) DIF: Basic on the reading before press 4key
compute the difference of current reading
d) AVG: measuring average temperature
e) HAL: high temperature alarm, When selected HAL
press 5 keys to set high temperature alarm trigger
and confirmed by press 4 key. When reading over
trigger, L D display HI icon with BiBi audio sounds
f) LAL: low temperature alarm, When select LAL.
Press 5 keys to set low temperature trigger and
confirmed by pressing 4 keys. When reading over
trigger. L D display LOW icon with BiBi audio
sounds.
g) STO: data storage. When selected STO, lock &
DATA indicator will shown. when press 4 key. After
temperature read out press 6 key to store then
memory unit will shown. There 12 groups memory
unit available. To recall the stored data in normal
measuring mode by press 6 keys for 3 second.
h) EMS: Emissivity. Press 5 key for emissivity setting,
press 4 keys to save setup and back to normal
status
7) elsius/Fahrenheit switch: Please open battery and
push the slide switch for conversion
www.Tools.in.th
www.Tools.in.th

Other Benetech Thermometer manuals

Benetech GM550 User manual

Benetech

Benetech GM550 User manual

Benetech GM700 User manual

Benetech

Benetech GM700 User manual

Benetech GM700 User manual

Benetech

Benetech GM700 User manual

Benetech GM320 User manual

Benetech

Benetech GM320 User manual

Benetech GM550 User manual

Benetech

Benetech GM550 User manual

Popular Thermometer manuals by other brands

Chino IR-SA Series instructions

Chino

Chino IR-SA Series instructions

Hama TH-100 operating instructions

Hama

Hama TH-100 operating instructions

Extech Instruments 42540A user manual

Extech Instruments

Extech Instruments 42540A user manual

B&H ThermoTek 1020 user manual

B&H

B&H ThermoTek 1020 user manual

Vicks V938 user guide

Vicks

Vicks V938 user guide

Weber iGrill Mini user guide

Weber

Weber iGrill Mini user guide

Welcare WDT404 user manual

Welcare

Welcare WDT404 user manual

Welcare WDT101 user manual

Welcare

Welcare WDT101 user manual

National Geographic 257NE user manual

National Geographic

National Geographic 257NE user manual

iHerz iFlex user manual

iHerz

iHerz iFlex user manual

BABEI HB542 manual

BABEI

BABEI HB542 manual

BGS technic 6005 instruction manual

BGS technic

BGS technic 6005 instruction manual

Honeywell TM004 user manual

Honeywell

Honeywell TM004 user manual

TFA 30.1013 user manual

TFA

TFA 30.1013 user manual

ZAKARIAN K62415 manual

ZAKARIAN

ZAKARIAN K62415 manual

Microlife MT 1951 instructions

Microlife

Microlife MT 1951 instructions

ADC Adtempt 419 Instructions for use

ADC

ADC Adtempt 419 Instructions for use

Oricom NFS100 user manual

Oricom

Oricom NFS100 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.