MYNUTE X R
1 WARNINGS AND SAFETY
b Theboilersmanufacturedinour factories arecheckedeveninthesmallestdetails in
ordertoprotectusersandinstallersagainstpossibleinjury.Afterworkingonthepro-
duct, qualified personnel must check the electrical wiring, in particular the stripped
partofleads,whichmust notprotrudefromtheterminalboardand avoiding possible
contact with live parts of the leads themselves.
b Thisinstaller and user manualconstitutes an integral partof the product: makesure
they are always kept with the appliance, even if it is transferred to another owner or
user, or moved to another heating system. In the event of loss or damage, please
contact your local TechnicalAssistance Centre for a new copy.
b Theboilermustonlybeinstalledandservicedbyqualifiedpersonnel,inaccordance
with current regulations.
b The installer must instruct the user about the operation of the appliance and about
essential safety regulations.
b This boiler must only be used for the application it was designed for. The manu-
facturer accepts no liability within or without the contract for any damage caused
to people, animals and property due to installation, adjustment and maintenance
errors or to improper use.
b Thisapplianceshould notbeoperatedby childrenyoungerthan8 years,peoplewith
reduced physical, sensory or mental capacities, or inexperienced people who are
not familiar with the product, unless they are given close supervision or instructions
on how to use it safely and are made aware by a responsible person of the dangers
itsusemightentail.Childrenmustnotplay withtheappliance.It istheuser'srespon-
sibility to clean and maintain the appliance. Children should never clean or maintain
it unless they are given supervision.
b After removing the packaging, make sure the content is in good condition and com-
plete. Otherwise, contact the dealer from whom you purchased the appliance.
b The safety valve outlet must be connected to a suitable collection and venting sy-
stem. The manufacturer declines all liability for any damage caused due to any
intervention carried out in the safety valve.
b The seal of the condensate drainage connection line must be secure, and the line
must be fully protected against the risk of freezing (e.g. by insulating it).
b Check that the rainwater drainage channel of the flue gas exhaust coupling and the
relative connecting pipe are free of obstructions.
b Dispose of all the packaging materials in the suitable containers at the correspon-
ding collection centres.
b Dispose of waste by being careful not to harm human health and without employing
procedures or methods which may damage the environment.
b During installation, inform the user that:
- in the event of water leaks, the water supply must be shut off and the Technical
Assistance Centre contacted immediately
- periodically check that the operating pressure of the hydraulic system is compri-
sed between 1 and 1.5 bar.
b If the boiler is not used for a long period of time, it is recommended to perform the
following operations:
- turn the main switch of the appliance and the main switch of the system to "off"
- close the fuel and water taps of the heating and domestic hot water system
- empty the heating and domestic hot water circuits if there is the risk of freezing.
b Boiler maintenance must be carried out at least once a year; this should be booked
in advance with the Technical Assistance Centre to ensure the necessary safety
standards.
b For the assembly, programming and commissioning of the boiler when used in
hybrid systems with a heat pump, water tank and solar heating circuit refer to the
system manual.
At the end of its life, the product should be not be disposed of as solid urban waste, but
rather it should be handed over to a differentiated waste collection centre.
For safety reasons, please remember that:
a Itisforbiddentoactivateelectricdevices or appliancessuchasswitches,household
appliances and so on if you notice a smell of fuel or unburnt fuel. In this case:
- ventilate the room by opening the doors and windows:
- close the fuel shut-off device;
- ask the Technical Assistance Service or professionally qualied personnel to
intervene promptly.
a It is forbidden to touch the appliance while barefoot or if parts of your body are wet.
a Any technical or cleaning operation is forbidden before disconnecting the appliance
from the main power supply by turning the system's main switch to "OFF" and the
main switch of the boiler to "OFF".
a Do not modify the safety or adjustment devices without the manufacturer’s authori-
sation and precise instructions.
a Itisprohibitedtopull,detachor twist the electricalcablescomingfromtheappliance
even if it is disconnected from the mains power supply.
a Avoid blocking or reducing the size of the air vent openings in the installation room,
donotleaveinflammablecontainersandsubstancesintheroomwheretheapplian-
ce is installed.
a Do not leave flammable containers and substances in the room where the device
is installed.
a It is forbidden to disperse the packaging material in the environment and leave it
withinchildren'sreachasit may beapotentialsourceofdanger.Itmustbedisposed
in accordance with the present law.
a It is forbidden to obstruct the condensate drain outlet. The condensate drain pipe
should be facing the discharge pipe, preventing the formation of further drain pipes.
a Never carry out any work on the gas valve.
a Only for the user: Do not access the inside of the boiler. Any work on the boiler
should be carried out by the Technical Assistance Centre or by professionally qua-
lified personnel.
INSTALLATION MANUAL
2 DESCRIPTION
The MYNUTE X R boilers have a newACC combustion control system (active combustion
control). This new control system, developed by Beretta, in all circumstances provides
functionality, efficiency and low emissions. The ACC system uses an ionisation sensor
immersed in the burner flame, whose information allows the control board to operate the
gas valve that regulates the fuel. This sophisticated control system provides for the auto
adjustment of the combustion, thereby eliminating the need for an initial calibration. The
ACC system can adapt the boiler to operate with different gas compositions, different pipe
lengths and various altitudes (within the design limits). The ACC system can also perform
an auto-diagnostic operation that locks out the burner before the permitted upper emission
limit is exceeded.
MYNUTE X R is a type C condensing wall-hung boiler that is able to operate as follows:
A CASE: HYDRAULIC CONFIGURATION=0
Only heating with no external water tank connected.
The boiler does not provide domestic hot water.
B CASE: HYDRAULIC CONFIGURATION=4
Only heating with an external water tank managed by a thermostat:in this condition, the
boiler delivers hot water to the water tank for the preparation of DHW whenever a demand
is made by the relative thermostat.
C CASE: HYDRAULIC CONFIGURATION=3
Only heating with an external water tank (accessory kit available by request) managed by
a temperature probe for the production of DHW. If the water tank is not supplied by our
company, make surethattherelative NTC probe has the followingcharacteristics:10kOhm
at 25°C, B 3435 ±1%.
Dependingonthefumedischargeaccessoryused,itis classified in categories B23P;B53P;
C(10)*; C13,C13x; C33,C33x; C43,C43x; C53,C53x; C83, C83x; C93, C93x.
* Currently not available on model 40kW.
In configuration B23P (when installed indoors), the appliance cannot be installed in bedro-
oms, bathrooms, showers or where there are open fireplaces without a proper air flow. The
room where the boiler is installed must have proper ventilation. Detailed requirements for
the installation of the flue, the gas piping and for ventilating the room, can be found in UNI
7129-7131.
In configuration C, the appliance can be installed in any type of room and there are no
limitations due to ventilation conditions or room volume.
3 INSTALLATION
3.1 Cleaning the system and characteristics of the water
In the case of a new installation or replacement of the boiler, it is necessary to clean the
heating system. To ensure the device works well, top up the additives and/or chemical tre-
atments (e.g. anti-freeze liquids, filming agents, etc.) and check the parameters in the table
are within the values indicated.
PARAMETERS UM HEATING CIRCUIT WATER FILLING WATER
pH value 7–8 -
Hardness °F - < 15
Appearance - clear
Fe mg/kg 0.5 -
Cu mg/kg 0.1 -
3.2 Handling
After unpacking, handling of the boiler is done manually using the support frame
3.3 Installation room
The MYNUTE X R boiler can be installed in various types of room, as long as the discharge
of the combustion product and the combustion air suction are outside the room itself.
Inthiscase the room does not need anyventilationopeningsincethe MYNUTE X R boilers
have a combustion circuit that is "airtight" with respect to the installation environment.
EN ENGLISH