DeletingmeasuredvaluesAveragevaluesUsermemory Individualmeasuredvalues
you can start measuring.
Hluchov 1353
250 01 Brandýs nad Labem - Stará Boleslav, Czech Republic
User memory 2
Complaints / service
User memory 1
BORGY CZ, a.s.
According to WHO guidelines you have ...
Diastolic pressure ... mmHg
Heart rate ... heart rate behind
• When the memory button M is pressed again, the last values of the individual measurements with the date
and time of the measurement always appear.
• Carefully clean the blood pressure monitor only with a slightly damp cloth.
Battery life for about
250 measurements, depending on blood pressure, or inflation pressure
Housing and protective covers The housing of the adapter protects against contact with parts that are, resp. They could be, under current (fingers, needles,
test hooks). The user must not touch the patient and the output plug of the AC adapter at the same time.
The device is ready for operation,
• After pressing the memory button M again, the average value of the last 7 days of the evening
measurement will appear (evening: 18.00 - 21.00, PM display).
2. you moved or talked during the measurement (E2),
d 145 mm x š 96 mm x v 60 mm
100–240 V, 50–60 Hz
Specifications are subject to change without notice due to updating.
Systolic pressure ... mmHg
5. Inflation pressure exceeding 300 mmHg (E5);
Model no.
The device has double protective insulation and is equipped with a primary thermal fuse that disconnects the device from the
mains in the event of a fault.
• Select the desired user memory
Cuff pressure 0 - 300 mmHg, systolic 50 - 250 mmHg, diastolic 30 - 200 mmHg, Pulse 30 - 180 beats / minute
service address.
8. Error messages / troubleshooting
systolic ± 3 mmHg, diastolic ± 3 mmHg, pulse ± 5% of displayed value
11. Adapter
minute
All values in memory have been cleared.
• Do not use any cleaning agents or solvents.
Accessories
Instructions for use, 4 x 1.5 V AA batteries, storage case
3. the cuff is too tight or too loose (E3),
Approx. 264 g (without batteries)
If there is more than 60 measurement data in the memory, the oldest data is currently deleted.
10. Technical parameters
• This device complies with the European standard EN60601-1-2 and is subject to special precautions regarding electromagnetic compatibility. Please note that portable
and mobile high-frequency communication devices may affect this device. You can request more detailed information at the customer service address provided or read at the end of
the operating instructions.
Average value:
Diastolic pressure ... mmHg
6. the batteries are low (E6).
Measurement
method
Measurement range
Display accuracy
Measurement uncertainty
Memory Dimensions
Weight Cuff size
Permissible operating
conditions +10 ° C to +40 ° C, ÿ 85% relative humidity (non-condensing)
Before using the adapter, make sure that the batteries have been removed from the battery compartment.
Voice output when the function is on
• Press the memory button M. First, the average value of all stored measurement values of this AVG
user memory is displayed.
In the event of a fault, the error message E_ appears on the display. Error messages may appear if
max. permissible standard deviation according to the clinical trial: systolic pressure 8 mmHg / diastolic 8 mmHg
Model
Input
Output
Manufacturer Protection
According to WHO guidelines you have ...
5 seconds.
• Never wash the appliance under water, as it could get inside and damage it.
Internal
power supply classification, IPX0, without AP or APG, continuous operation, application part type BF
6 V DC, 600 mA, only in combination with Beurer blood pressure monitors.
• Switch on the device with the on / off switch.
• To clear the values from the corresponding memory, switch on the device first.
BM 49
• The device complies with the EU Medical Products Directive 93/42 / EC, the Medical Products Act and the standards EN1060-1 (Non-invasive blood pressure monitors, part 1:
General requirements), EN1060-3 (Non-invasive blood pressure monitors, part 3: Additional requirements for electromechanical blood pressure measuring systems) and IEC80601-2-30
(Medical electrical equipment, Part 2-30: Special safety provisions including main performance attributes of automatic non-invasive blood pressure monitors).
Systolic pressure ... mmHg
Heart rate ... beats per minute
In these cases, repeat the measurement. Be careful not to move or talk. If necessary, reinsert or replace the batteries.
Permissible storage conditions -20 ° C to +50 ° C, ÿ 85% relative humidity, external pressure 800 –1050 hPa
DC connection polarity
9. Cleaning and storing the device
Power supply 4 x 1.5 V AA batteries (alkaline type LR6)
Protective insulation / protection class 2
voice guide
• After pressing the memory button M again, the average value of the last 7 days of the morning
measurement appears (morning: 5.00 - 9.00, AM display).
1. no pulse can be detected (E1),
2 x 60 memory locations
No. FW 7575M / EU / 6/06
The results are saved together with the date and time after each successful measurement.
• The unit immediately enters standby mode (clock mode).
• Do not place any heavy objects on the device after storing it. Remove the batteries. The cuff hose must not be broken.
A place in memory ...
4. errors occur during the measurement (E4),
22 to 36 cm
Friwo equipment construction GmbH
by pressing the function buttons - / +.
Select the desired user memory. Press the function keys - and + simultaneously on
oscillometric, non-invasive blood pressure measurement on the arm
• The accuracy of this blood pressure monitor has been carefully checked and developed with a long, usable lifespan. When using the device in healthcare, carry out technical
measurements by appropriate means. You can find out the exact details for checking accuracy
CONTACT TO THE SERVICE CENTER: