ENGLISH Blood Pressure Monitor
Instructions for use.......................... 3
ESPAÑOL Tensiómetro
Manual de instrucciones ............... 30
FRANÇAIS Tensiomètre
Mode d’emploi................................ 58
BM 76

READ THIS MANUAL COMPLETELY AND CAREFULLY BEFORE USING THIS PRODUCT
Keep this manual in a safe location for future reference
LEA TODO ESTE MANUAL CON ATENCIÓN ANTES DE USAR ESTE PRODUCTO
Conserve este manual en un lugar seguro para consultarlo en el futuro
LISEZ CE MODE D’EMPLOI COMPLÈTEMENT ET ATTENTIVEMENT AVANT
D’UTILISER CE PRODUIT
Conservez ce manuel en lieu sûr pour y faire référence ultérieurement

3
1. IMPORTANT SAFETY NOTES
Signs and symbols
Whenever used, the following signs identify safety and
property damage messages and designate a level of
hazard or seriousness.
READ THIS ENTIRE MANUAL, THE SAFETY
SECTION AND ALL INSTRUCTIONS AND
WARNINGS COMPLETELY AND CAREFULLY
BEFORE USING THIS PRODUCT. FOLLOW ALL
SAFETY INSTRUCTIONS AND WARNINGS TO
AVOID HAZARDOUS SITUATIONS AND TO MAKE
CORRECT USE OF THIS PRODUCT.
This is the safety alert symbol. It
alerts you to potential personal
injury hazards. Obey all safety
messages that follow this symbol
to avoid possible injury or death.
WARNING WARNING indicates a hazardous
situation which, if not avoided,
could result in death or serious
injury.
ENGLISH
Contents
1. IMPORTANT SAFETY NOTES............................... 3
2. Indication for use................................................. 13
3. Important Information ........................................ 14
4. Package Contents............................................... 14
5. Device description .............................................. 15
6. Preparing for Measurement ............................... 16
7. Measuring Blood Pressure................................. 17
8. Evaluating Results............................................. 20
9. Displaying and Deleting Measurements ......... 21
10. Care and Maintenance...................................... 23
11. Troubleshooting Guide...................................... 23
12. Technical Specifications................................... 23
13. FCC Statement .................................................. 26
14. Warranty............................................................. 26

4
CAUTION CAUTION indicates a hazardous
situation which, if not avoided,
may result in minor or moderate
injury.
NOTICE NOTICE addresses practices
not related to personal
injury, such as product
and/or property damage.
WARNING:
•
Consult your physician or pharmacist before
starting to measure your blood pressure.
•
Read and understand all instructions and warnings
before using this device.
•
Like any oscillometric blood pressure measurement
devices, certain medical conditions can affect the
measurement accuracy, among others:
– disorder of the cardiac rhythm
– very low blood pressure
– patients in shock
– patients with very low blood perfusion
– diabetes
– vessel anomalities
– people with electrical implants, such as a cardiac
pacemaker
– women who are pregnant.
•
Due to their condition the oscillometric
measurement method can produce incorrect
readings. This represents a risk for your health,
since values may be interpreted incorrectly. Always
consult your physician to determine what will be
suitable for you.
•
This product does not and is not intended to
provide a medical diagnosis. Measurements results
are for reference only. Self-diagnosis and treatment,
e.g. regarding medication, using measured results
represent a risk for your health. Always consult
with a licensed physician for determination of
appropriate medication and dosage thereof. Follow
the instructions of your physician or licensed
healthcare provider. If you have or suspect that
you have a medical problem, promptly consult your
physician. If you have an emergency please call
911 immediately.

5
•
Only a physician or a trained health care
professional who is familiar with your medical
history is able to accurately interpret your blood
pressure measurements. Consult your physician
before starting blood pressure monitoring.
•
This product is not intended to serve as a
substitute for the advice of a physician or medical
professional. This product is not intended to
substitute for regular medical checkups. Contact
your physician for specific information about your
blood pressure.
•
Please note that technically related measuring
tolerances are possible. Please see section ’12.
Technical Specifications’ for details.
NOTE: A single measurement does not provide an
accurate indication of your true blood pressure.
You need to take and record several readings
over a period of time. Try to measure your
blood pressure at the same time each day for
consistency.
•
Any cuff related blood pressure measurement
in high repetition rates, can lead to severe
measurement side effects, e.g.
– any nerv compression with temporary arm/hand
paralysis
– the release of an arterial or venous thrombus,
which can cause a life threatening situation.
•
Please contact your physician about the specific
risks of cuff pressure in your specific case.
•
The ’irregular heartbeat’ function does not replace
a cardiac examination, but may help to detect
potential pulse irregularities at an early stage.
Always consult your physician to determine what
will be suitable for you.
•
The ’irregular heartbeat’ function is not designed
for diagnosing or treating an arrhythmic disorder.
Arrhythmia can only be ascertained by a licensed
physician.
•
The WHO chart is not intended to replace a medical
diagnosis. This chart is only a reference for different
classifications of blood pressure.
•
If you notice abnormal or suspicious variations
in blood pressure measurements, consult your
physician immediately.
•
Women who underwent a breast or axillar lymph
node removal operation should consult a physician

6
or licensed healthcare provider before starting
blood pressure measurements.
•
Prior to use, you have to ensure that the blood
pressure monitor is free of damage. If in doubt, do
not use the unit and contact customer service at
1-800-536-0366.
•
This device is intended only for personal, non-
commercial, adult use in measuring blood pressure
and pulse rate. Do not use the product for any other
purpose. This product is not intended for use in
a hospital, physician’s office, or any other health
care facility.
•
The unit must be used in accordance to the specified
ambient conditions, otherwise the accuracy of
readings might be affected. See section ’10. Care
and Maintenance’ and section ’12. Technical
Specifications’ for details.
•
Do not wrap the cuff around body parts other than
your arm. Misuse represents a risk to your health.
•
Please do not share the cuff with other persons, to
avoid cross infection.
•
Use this monitor only on humans.
•
This product is not intended for use by or on
children, toddlers and infants or on persons who
cannot express their consent, e.g. persons with
mental disorders or the like. Consult your physician
for alternative methods of measuring a child’s blood
pressure.
•
This product is not a toy. Keep it out of reach of
children, toddlers, and infants.
•
Keep the product out of the reach of pets.
•
Packaging materials are a deadly hazard for
children and can cause suffocation. Remove all
packaging materials immediately and keep them
away from children at all times.
•
This product contains small parts that may present
a choking hazard to children. Keep the unit and
all parts out of reach of children. NEVER LEAVE
CHILDREN OR THOSE WHO REQUIRE CLOSE
SUPERVISION UNATTENDED WITH THIS DEVICE.
•
The tubing presents a strangulation hazard. Keep
this product away from children and those who
require close supervision, e.g. people with mental
disorders.

7
•
Do not drape tube around neck. This presents a
strangulation hazard.
•
People with disabilities, activity limitations, or who
are physically frail, should be assisted by another
person when using this unit.
•
Proper cuff size is important for accurate
measurements. Only use the device on adults
who have the right upper arm circumference
for this instrument. See section ’12. Technical
Specifications’ for suitable upper arm
circumferences.
•
Do not use any cuffs, tubes, parts and accessories
other than those explicitly recommended by the
manufacturer for use with this product. Parts and
accessories not approved for use with the device
may cause damage to your health and to the
product.
•
Electromagnetic interference: Avoid strong
electrical or electromagnetic fields in the direct
vicinity of the device (e.g. mobile telephones,
microwave ovens) while it is in operation, as
inaccurate measurements may result. To prevent
such interference, use the unit at a sufficient
distance from such devices or turn the devices off.
•
The blood pressure monitor must not be used in
connection with a high-frequency surgical unit.
•
Do not measure your blood pressure while operating
a vehicle or in any situation which requires your full
attention.
•
During the blood pressure measurement, blood
circulation must not be stopped for an unnecessarily
long time. If the device malfunctions, remove the
cuff from the arm.
•
Avoid any mechanical restriction, compression or
bending of the cuff line.
•
Do not allow sustained pressure in the cuff or
frequent measurements. The resulting restriction
of the blood flow may cause injury.
•
Ensure that the cuff is not placed on an arm in
which the arteries or veins are undergoing medical
treatment, e.g. intravascular access or therapy, or
an arteriovenous (AV) shunt.
•
Do not use the cuff on people who have undergone
a mastectomy.

8
CAUTION:
•
The device should not be used when your arm has
been wounded/injured or when a catheter has been
inserted. Such use may result in injury.
•
Remove any kind of arm jewelry or the like before
taking a measurement. This could cause bruises.
•
Do not place the cuff over heavy clothing (e.g. a
jacket or sweater sleeve) as the blood pressure
monitor will not be able to take a proper
measurement and there is an elevated danger
of acquiring hematoma or skin marks during the
course of the measurement.
•
In case the cuff does not stop inflating, interrupt
the measurement by pressing the start/stop button
and open the cuff at once.
•
Do not disassemble the unit, it may result in
injuries.
•
When applying the cuff, make sure there are no
wrinkles in the cuff. This could cause bruises.
•
Do not exert any kind of pressure on the hose
during measurement, e.g. laying your arms or
any other object on the hose. This could cause
incorrect measurements.
•
Blood pressure measurements can lead to
temporary marks on the skin at the site of the
cuff placement. This is especially the case in
high repetition rates, in hypertonic patients and
in patients with weak pulses. In rare cases a mark
may persist for a couple of days. Please contact
your physician about these specific risks of cuff
pressure in your specific case.
•
For hygienic reasons the cuff is intended only for
the use by one person.
•
Prolonged over-inflation (cuff pressure exceeds
300 mmHg or maintained above 15 mmHg for
longer than 3 minutes) of the bladder may cause
ecchymoma of your arm.
•
Please note that when inflating, the functions of
the limb in question may be impaired.
•
Do not place the cuff over wounds as this may
cause further injury.
•
The accuracy of any blood pressure measurement
with this device can be affected by a multitude of
causes. Some can be avoided some have to be

9
accepted at the time of measurement. Speak with
your physician about possible causes affecting
your blood pressure.
•
Do not inflate the cuff unless wrapped around arm.
•
Do not touch the unit, the tube and cuff and/
or press any buttons when measurement is in
progress, except for stopping the measurement.
Doing so may cause incorrect readings.
NOTICE:
•
The blood pressure monitor is made up of precision
electronic components. Accuracy of readings and
the instrument’s service life depend on careful
handling. Protect the unit against hard knocks
(e.g. dropping the unit), moisture, water, dirt, dust,
chemicals, extreme hot or cold temperatures,
major temperature fluctuations, direct exposure
to sunlight and heat sources which are too close
(e.g. stoves, heating radiators). This may damage
the unit. The device must be stored in the specified
ambient conditions. Please see section ’10. Care
and Maintenance’ and section ’12. Technical
Specifications’ for details.
•
Do not use any aggressive solvents, cleaning
agents, detergents or any other strong chemicals
to clean the device.
•
Never immerse and or spill water or any other liquid
onto the monitor or any components, otherwise
liquid will enter it and cause damage.
•
Do not wash the unit in a washing machine, dish
washer or tumble dryer.
•
Observe the local regulations for material
disposal. Dispose of the device, components
and optional accessories according to applicable
local regulations. Unlawful disposal may cause
environmental pollution.
•
Never attempt to repair, open and/or disassemble
the unit (including cuff and optional accessory) or
adjust it yourself. This may damage the unit and
impair the functions. If you need to have the unit
repaired, please contact our customer service.
Please see warranty for service contact. Before
submitting any complaint, first check the batteries
and replace them if necessary.
•
Changes or modifications to the device will nullify
the user warranty.

10
•
Do not drop or insert any object into any opening
or hose. This may damage the unit.
•
Do not press the buttons with excessive force or
with pointed objects.
•
To conserve the batteries, the monitor switches
off automatically if no buttons are pressed for one
minute.
•
The device is only intended for the purpose
described in these instructions for use. The
manufacturer is not liable for damage resulting
from improper or careless use.
•
If you are using the unit for the first time, please
remove the protective film from the display.
•
The monitor can maintain the safety and
performance characteristics for a minimum of
10.000 measurements or 3 years.
•
Further documents which include information for
the Calibration of the device can be asked at the
service address.
•
The device can be tested in case of supposed
inaccuracy every two years. Please contact the
nearest service address.
Cleaning and storing the device and cuff
To keep your digital blood pressure monitor in the
best condition and protect the unit from damage
follow the directions listed below:
•
C
lean your device and cuff carefully only with a
slightly moistened soft cloth and dry it immediately
with a soft dry cloth. Do not press.
•
W
hen storing the device, make sure that no heavy
objects are placed on top of it.
•
D
o not fold the cuff and tubing tightly. The cuff
tube should not have any sharp kinks and keep it
away from sharp edges.
•
I
f the unit is stored near freezing, allow it to
acclimate to room temperature before use.
•
A
lways store the unit in its storage pouch after use.
•
T
his unit may not meet its performance
specifications if stored or used outside of the
temperature and humidity ranges (see section ’12.
Technical Specifications’).
•
U
se the unit consistent with the instruction
provided in this manual.

11
Advice on use
•
For consistency, always measure your blood
pressure at the same time each day.
•
Always wait at least 5 minutes between
measurements to allow the blood circulation in
your arm to return to normal. You may need to
increase the wait time depending on your individual
physiological characteristics. Because of normal
physiologic changes and the many external
factors influencing blood pressure, it is unusual
to obtain identical blood pressure measurements,
even when taken a few minutes apart. Speak with
your physician to determine what is affecting your
blood pressure and which variation may be seen
as normal in your case.
•
When performing multiple measurements on
an individual, wait five minutes between each
measurement.
•
Do not take a measurement within 30 minutes of
eating, drinking, smoking or exercising. You should
not be physically tired or exhausted while taking
measurement.
•
Repeat the measurement if you are unsure of the
results.
•
Measurements are for your information only –
they are no substitute for a medical examination.
Discuss the measurements with your doctor and
never base any medical decisions on them (e.g.
medicines and their administration).
•
Do not use the blood pressure monitor on
newborns, pregnant women or patients with pre-
eclampsia. Consult your doctor before using the
blood pressure monitor during pregnancy.
•
Cardiovascular diseases may lead to incorrect
measurements or have a detrimental effect on
measurement accuracy. The same also applies
to very low blood pressure, diabetes, circulatory
disorders and arrhythmias as well as chills or
shaking.
•
For reliable monitoring and reference of
blood pressure, keeping long-term records is
recommended.
•
To minimize measurement variations due to
physical activity, rest at least 5 minutes before
measuring your blood pressure (or 15 minutes after
strenuous activity).
•
Stress raises blood pressure.

12
•
Perform measurements in a quiet and relaxed
environment at room temperature.
Battery Handling Safety Precautions
•
Use only the size and type of batteries specified.
•
Be sure to follow the correct polarity when
installing the batteries. Reversed batteries may
cause damage to the device.
•
Do not mix different types of batteries together
(e.g. Alkaline and Carbon-zinc or rechargeable
batteries) or old batteries with fresh ones. Always
replace batteries as a simultaneous set.
•
If the batteries in the device are depleted or the
device will not be used for a long period of time,
remove the batteries to prevent damage or injury
from possible battery leakage.
•
Do not try to recharge batteries not intended to be
recharged; they can overheat and rupture (follow
battery manufacturer’s directions).
•
Do not dispose of batteries in fire, batteries may
explode or leak.
•
Clean the battery contacts and also those of the
device prior to battery installation.
•
Remove discharged batteries from the product and
dispose/recycle in compliance with all applicable
laws.
•
Keep batteries away from children and pets.
Batteries may be harmful if swallowed. Should
a child or pet swallow a battery, seek medical
assistance immediately.
Notes on electromagnetic
compatibility
•
The device is suitable for use in all environments
listed in these instructions for use, including
domestic environments.
•
The use of the device may be limited in the
presence of electromagnetic disturbances. This
could result in issues such as error messages or
the failure of the display/device.
•
Avoid using this device directly next to other
devices or stacked on top of other devices, as
this could lead to faulty operation. If, however, it is
necessary to use the device in the manner stated,
this device as well as the other devices must be
monitored to ensure they are working properly.

13
•
The use of accessories other than those specified
or provided by the manufacturer of this device can
lead to an increase in electromagnetic emissions
or a decrease in the device’s electromagnetic
immunity; this can result in faulty operation.
•
Failure to comply with the above can impair the
performance of the device.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
If the instruction manual is damaged or if you
no longer have the instruction manual in your
possession, please contact customer service at
1-800-536-0366 or at info@beurer.com.
Dear Valued Customer,
Thank you for choosing one of our products. Our name
stands for high-quality, thoroughly tested products for
application in the areas of heating, weight management,
blood pressure, body temperature, pulse, gentle therapy,
massage, and beauty.
Register your product today to receive further benefits:
• added protection for your purchase
• health and wellness tips
• new product information
• continual outstanding customer service and support.
Visit www.registerbeurer.com or contact customer
service at 1-800-536-0366.
Please read these instructions for use carefully and keep
them for later use. Make them accessible to other users
and observe the information they contain.
With kind regards,
Your Beurer Team
2. Indication for use
The upper arm blood pressure monitor is used to carry
out non-invasive measurement and monitoring of the
arterial blood pressure values in adults. This allows you
to quickly and easily measure your blood pressure, save
the measured values and display the development and
average values of the measured values taken.

14
3. Important Information
Signs and Symbols
The following symbols are used in these instructions
for use, on the packaging and on the type plate for the
device and accessories:
Attention
Note
Note on important information
Observe the instructions for use
Application part, type BF
Direct current
Storage
Permissible storage
temperature and humidity
Operating
Permissible operating
temperature and humidity
Protected against foreign objects
equal to or greater than 12.5 mm
in diameter and against vertically
falling drops of water
S
N
Serial number
4. Package Contents
•
1
x BM 76 Blood pressure monitor
•
1
x Universal cuff 8.7 - 17.3 in (22 - 44 cm)
•
1
x Storage pouch
•
4
x 1.5V AA alkaline batteries
•
1
x Instruction manual
•
1
x Quick start guide

15
5. Device description
1. Arm Cuff
2. Air Tube
3. Air Tube Connector
4. Start/Stop Button
5. +/- Buttons
6. Blood Pressure Classification Scale
7. Air Tube Socket (on side)
8. LCD Display
9. Memory Button
10. SET Button
Icons in the display:
8
112
10
9
567
2
3
4
11
1. Time and Date
2. Systolic Pressure
3. Diastolic Pressure
4. Pulse Rate
5. Irregular Heartbeat Indicator
6. Battery Level Indicator
7. Memory Space Number/Average ( )/
Morning Reading ( )/Evening Reading ( )
8. Deflation Icon
9. Blood Pressure Classification Indicator
10. User memories
11. Bluetooth®transfer indicator
1
2
3
MSET
Bluetooth®
mmHg
SYS
mmHg
DIA
/min
PUL
8
7
6
410
5
9

16
System requirements for the ‘beurer
HealthCoach‘ app
Bluetooth®from 4.0, iOS from version 10.0, AndroidTM
from version 5.0.
List of compatible devices:
6. Preparing for Measurement
Installing/Replacing Batteries:
If the batteries are depleted and you cannot power the
blood pressure monitor on, you will need to reset the
date, time and Bluetooth®settings after replacing the
batteries. All stored measurements will still be saved.
Slide the battery compartment cover in the direction
of its arrow to remove. Insert four AA alkaline
batteries according to the polarity markings inside the
compartment. Reattach battery compartment cover.
Setting the hour format, date, time and
Bluetooth®settings:
If date and time are not set, stored measurements will
not have a valid timestamp associated with them.
NOTE: Press and hold the +/- Buttons to advance
values rapidly.
1. If ’
12h
’ is not flashing in the LCD Display, press and
hold the SET Button for five seconds.
2.
Select an hour format (12 or 24 hour display) with the
+/- Buttons and press the SET Button to confirm.
3.
The year flashes on the LCD Display. Set the year
with the +/- Buttons and press the SET Button to
confirm.
4.
The month flashes on the LCD Display. Set the
month with the +/- Buttons and press the SET
Button to confirm.
5.
The day flashes on the LCD Display. Set the day with
the +/- Buttons and press the SET Button to confirm.
NOTE: If the hour format is set to 24h, the day/
month display sequence is reversed.

17
6. The hour flashes on the LCD Display. Set the hour
with the +/- Buttons and press the SET Button to
confirm.
7.
The minutes flash on the LCD Display. Set the
minutes with the +/- Buttons and press the SET
Button to confirm.
8.
’On’ will flash in the LCD Display. Use the +/-
Buttons to select whether to activate (’On’) or
deactivate (’Of’) automatic Bluetooth®data transfer
to a mobile device. Press the SET Button to confirm
and exit. Note that keeping Bluetooth®activated will
increase battery drain.
7. Measuring Blood Pressure
The blood pressure monitor needs to be at room
temperature when measuring. Measurements can
be performed on either arm.
Positioning the Cuff:
Place the cuff on to the bare left
upper arm. The circulation of
the arm must not be hindered
by tight clothing or similar.
The cuff must be placed on
the upper arm so that the
bottom edge is positioned
0.8 - 1.2 in (2-3 cm) above
the elbow and over the artery.
The line should point
to the centre of the palm.
Now tighten the free end of
the cuff, but make sure that it
is not too tight around the
arm and close the
hook-and-loop fastener. The
cuff should be fastened so that
two fingers fit under the cuff.
Now insert the cuff line into
the connection for the cuff
connector.
Blood pressure can vary between the right and left
arm, which may mean that the measured blood
pressure values are different. Always perform the
measurement on the same arm.

18
If the values between the two arms are significantly
different, please consult your doctor to determine
which arm should be used for the measurement.
CAUTION:
Only use original Beurer cuffs with this device. The
included cuff is suitable for an arm circumference of
8.7 – 17.3 inches (22 – 44 cm). For larger arm
circumferences, contact customer service to order
a larger cuff.
Correct Posture:
•
Rest for at least five minutes before each
measurement.
•
Perform the measurement either sitting or lying
down. Always make sure that the cuff is level with
your heart.
•
To perform a measurement, sit comfortably with
your arms and back supported. Do not cross your
legs and place your feet flat on the floor.
•
Keep still during the measurement and do not talk.
•
R
elax your arm and the palm of your hand.
Select a User Memory
This unit has four user numbers, each with 30
storage slots each.
1. Press the SET Button and select a user memory
from 1 to 4 using the +/- Buttons.
2. Confirm by pressing the Start/Stop Button or just
wait for three seconds to set the user number.
Performing a Measurement
1. With the cuff attached properly and in a correct
posture, press the Start/Stop button . All
LCD Display elements will briefly display and
measurement will begin after about three seconds.
To cancel a measurement at any time, press the
Start/Stop Button .

19
2. As a measurement concludes, air pressure in the
Cuff will release. The pulse symbol ( ) will display,
along with systolic and diastolic pressure. The
measurement data will be stored into the selected
user memory.
3. ’ ’ and a number from 1 to 7 will appear if the
measurement was not performed properly. Refer
to the ’Troubleshooting Guide’ section for details
about specific error message numbers and repeat
the measurement.
4. Press the Start/Stop button to shut off the
blood pressure monitor. The device will also shut
off by itself after about one minute.
5. Wait at least five minutes before taking another
measurement.
Bluetooth®data transfer
If the Bluetooth
®
function is activated on the
unit, measurement data is transferred to your
paired mobile device after measurement.
The blood pressure monitor will display the
Bluetooth
®
symbol ’ ’ during data transfer.
When connecting for the first time, a randomly-
gene rated six-digit PIN code is displayed on device,
and at the same time an input field appears on the
smartphone in which you must enter this six-digit
PIN code. After successfully entering the code, the
device will be connected to your smartphone. Press
the Start/Stop button again to shut off the blood
pressure monitor.

20
In order to transfer data to the
‘beurer HealthCoach’ app, you
must add the BM 76 device to
the app under ’My devices’. The
‘beurer HealthCoach’ app must
be active on your nearby mobile
device to enable data transfer.
8. Evaluating Results
Irregular Heartbeat:
This device can detect irregular heartbeat patterns
during measurement and will indicate them by
displaying the irregular heartbeat indicator .
This may be an indicator for arrhythmia, which is
a condition where the heart rhythm is abnormal.
These symptoms (omitted or premature heartbeats,
slow or excessively fast heart rate) may be caused,
among other things, by heart disease, age, physical
predisposition, excessive use of stimulants, stress,
or lack of sleep. Arrhythmia can only be ascertained
through examination by your doctor.
Repeat the measurement if the Irregular Heartbeat
Indicator displays after a measurement. Rest for at
least five minutes between measurements and do
not talk or move during measurement. If the
icon appears often, contact your doctor, since self-
diagnosis and treatment based solely on the test
results may be dangerous. It is vital to follow your
doctor‘s instructions
Blood Pressure Classifications
Measurements can be classified and assessed by the
table below. However, these standard values are only
a general guideline, since individual blood pressure
varies in different people and different age groups, etc.
Table of contents
Languages:
Other Beurer Blood Pressure Monitor manuals

Beurer
Beurer BC 19 User manual

Beurer
Beurer BC 32 User manual

Beurer
Beurer BM 47 User manual

Beurer
Beurer BC 44 User manual

Beurer
Beurer BC 32 User manual

Beurer
Beurer BM 26 User manual

Beurer
Beurer BC 19 User manual

Beurer
Beurer BM 57 User manual

Beurer
Beurer BM 81 easyLock User manual

Beurer
Beurer BC 58 User manual

Beurer
Beurer BC 40 User manual

Beurer
Beurer bm 40 User manual

Beurer
Beurer BM 31 User manual

Beurer
Beurer BC 44 User manual

Beurer
Beurer BC 50 User manual

Beurer
Beurer BC 80 User manual

Beurer
Beurer BM 49 User manual

Beurer
Beurer BM 58 User manual

Beurer
Beurer BC 32 User manual

Beurer
Beurer BM 35 User manual