Beyond BY-P23B User manual

7*4in1 Osram 15w beam zoom par
User manual
P
le
a
se
rea
d t
he
ins
tr
u
ction
s
carefu
ll
y before use

2
TABLE OF CONTENTS
1.
S
afety
I
nst
r
uctions
........................................................................................2
2. Technical Specifications
...............................................................................4
3. How To Control The Unit
...........................................................................5
4.SHAPE
.........................................................................................................8
5. Trouble shooting
..........................................................................................9
6. Fixture Cleaning
........................................................................................10
statement
The product has well capability and intact packing when leave
factory. All of the user should comply with warning item and manual, any
misuse cause of the damages are not included in our guarantee, and
also can not be responsible for any malfunction & problem owing to
ignore the manual.
1.
S
afety
I
nst
r
uctions
Please keep this User Guide for future consultation. If you sell the unit to another
user, be sure that they also receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using
the unit.
Before operating, ensure that the voltage and frequency of power

3
supply match the power requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order
to avoid electric shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at
least 50cm from adjacent surfaces. Be sure that no ventilation slots are
blocked.
Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as
it is fire hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head
only, butalways by taking its base.
Maximum ambient temperature is Ta: 40℃. DO NOT operate it where the
temperature is higher than this Unit surface temperature may reach up to 85℃.
DO NOT touch the housing bare-hand during its operation. Turn off the power
and allow about 15 minutes for the unit to cool down before replacing or serving.
In the event of serious operating problem, stop using the unit
immediately.Never try to repair the unit by yourself. Repairs carried out by
unskilled people can lead to damage or malfunction. Please contact the
nearest authorized technical assistance center. Always use the same type
spare parts.
DO NOT touch anywire during operation ashigh voltage might be causing
electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to
rain or moisture.
DO NOT open the unit within five minutes after switching off.

4
The housing, the lenses, or the ultraviolet filter must be replaced
if they are visibly damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing
or attempt any repairs yourself. In the unlikely event your unit may require
service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that
the unit is firmly fixed to avoid vibration and slipping while operating.
And make sure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times of the unit’s weight. Also always use a
safety cable that can hold 12 times of the weight of the unit when installing the
fixture.
The equipment must be fixed by professionals. And it must be fixed at a place
where is out of the touch of people and has no one pass by or under it.
2. Technical Specifications
Light Sources: led 7*4in1 15w
Power Consumption: 100W
Zoom angel:7-60 degree
Power Voltage: AC100-240V, 50/60Hz
Packing Dimension:440*350*360mm
Net Weight: 5kg
Gross Weight:5.5kg
Control
DMXChannel: 12 Channel
Control Modes: DMX512

5
Construction
Display: Digital Display Panel
Data In/Out socket: 3-pin
Protection Rating: IP20
3. How To Controlit
The
DM
X512
is
wid
ely
used
in intellig
ent
lighti
ng
con
trol,with a DMX512
controller.connect several lights together,dmx in and dmx out,
3
pin
XLR
connectors
:
Pin
1:
G
ND
,
Pin
2:
Negative
signa
l
(-),
Pin
3:
P
os
itive
s
i
gna
l
(+)
Display:
MENU To select the programming functions
DOWN To go backward in the selected functions
uP To go forward in the selected functions
ENTER To confirm the selected functions
Set
DMX
Ad d res s
Cod e

6
1 Press "Menu" to "Set DMX Address",and press"ENTER" keys to enter into
2 Show "Set DMX Address DMX Address:001",Press the "UPand DOWN"
keys to amended
3Press "ENTER"keys to save and Exit,Press the"MENU"Keys does not save and
Exit
Menu Up Down Enter
Menu
Funcation
DDetails
D001
DMX addr set 001
Press up and down button to set the addr
code, press Enter button to save
R255
Red brightness
adjustment
Press up and down button to set the
brightness , press Enter button to save
G255
Green brightness
adjustment
Press up and down button to set the
brightness , press Enter button to save
B255
Blue brightness
adjustment
Press up and down button to set the
brightness , press Enter button to save
H255
Blue brightness
adjustment
Press up and down button to set the
brightness , press Enter button to save
Pr01
Built-in program set
01
Press up and down button to choose the
program, press Enter button to save
SP01
Built-in
program speed set
16
Press up and down button to choose the
programspeed , press Enter button to save
TEST
Test mode
Press up and down button to choose Music
orAuto Run mode
Reset
Reset
Press Enter button to reset the fixture

7
DMX channel´s functions and their values (12 DMX channels):
Mode/Channel
Value
Function
1
0-255
Zoom
From narrow to wide
2
0-255
Dimmer intensity:
Intensity0 to 100%
3
0-255
strobe
Strobe effect slow to fast
4
0-255
R dimming slow to fast
5
0-255
G dimming slow to fast
6
0-255
B dimming slow to fast
7
0-255
W dimming slow to fast
8
0-255
Rainbow
9
Music mode or Auto Run mode
0-60
Show the effect from CH1-CH8
61-120
Jump change
121-180
Gradual change
181-244
Jump change,gradual change, strobe
245-255
Music mode
10
Speed
0-255
Fast to slow
11
Zoom speed
0-255
Fast to slow
12
Reset
0-64
No funcation
65-128
Auto run
129-192
Music mode
193-255
Reset

8
4.SHAPE

9
5. Trouble shooting
F
ollow
ing
a
r
e
a
few
co
mm
on
pr
oble
m
s
th
a
t m
ay
occu
r d
uring
ope
r
a
tion
.
He
r
e
a
r
e
so
m
e
sugges
tion
s
for
easy
tr
ou
b
leshooting
:
A.
The
un
it
does
no
t work
,
no
li
ght
a
n
d t
he
f
a
n
d
oes
no
t w
o
rk
1.
Check
th
e
connect
ion of p
owe
r
and
m
a
in fu
se.
2.
M
easure
th
e
m
ains
volt
age
on
th
e
m
a
i
n
conne
ct
o
r
.
3.
Check
th
e
pow
er
on
LED.
B.
N
o
t
responding
t
o
D
MX
con
troll
er
1.
DM
X
LED
s
h
ou
ld b
e
on.
If
no
t,
check
DM
X
connectors,
ca
bl
es
to
see
if link
pr
ope
rly
.
2.
If th
e
DM
X
LE
D i
s
on
and
no
r
esponse
t
o
th
e
c
h
annel,
check
th
e
a
ddr
ess
s
etti
ngs
and
DM
X
pol
a
rity
.
3.
If
you
h
ave
i
nter
mittent DM
X
signa
l pr
oble
m
s,
check
th
e
p
ins
on
connecto
r
s
or
on
PCB
of th
e
u
nit or
the
pr
ev
iou
s
one.
4.
Try
to
use
ano
th
er
DM
X
co
ntroller
.
5.
Check
if th
e
DM
X
ca
b
les
r
un
nea
r or run
a
lon
gs
id
e
t
o
h
ig
h
voltage
ca
b
les
th
a
t
m
ay
cause
d
a
m
age
or in
terference
to DM
X
inter
face
circuit.
C.
One
of
the
channel
s
is
no
t w
o
rk
ing
w
el
l
1.
The
step
p
er
motor m
ig
ht b
e
damaged
or
the
ca
b
le
connected
to th
e
PCB
is
br
oken.
2.
Th
e
m
oto
r
’
s
d
r
ive
IC
on
the
PCB
m
ig
h
t
b
e
o
ut
of
co
ndition.

10
6. Fixture Cleaning
The
cleaning
o
f inter
na
l
and
externa
l
optica
l
lenses
a
nd/or mirr
ors
m
us
t b
e
ca
rr
ied
ou
t p
eriodica
lly to optimiz
e
light
ou
tput
.
Clea
nin
g
fr
equency
d
e
p
ends
on
th
e
environment
in which th
e
f
ixture
ope
r
ates
:
d
a
mp
,
s
m
oky
o
r p
a
rtic
ula
rly dirty
s
urr
ounding
can
cause
g
r
eater
acc
um
ulatio
n
of
d
i rt
on
the
u
nit’
s
optic
s
.
Cle
a
n
with
s
oft
clo
th
using
no
rm
a
l
g
l
a
ss
clea
ni
ng
fluid
.
A
lw
a
ys
dr
y
th
e
parts
ca
r
ef
ully
.
Cle
a
n
th
e
externa
l optic
s
a
t
leas
t
every
20
days.
Cle
a
n
th
e
in
terna
l opti
cs
a
t
leas
t
every
30/60
days.
Table of contents
Other Beyond Lighting Equipment manuals