1. To commence trace
2. Escape to exit TDR mode
3. Increase se ng
4. Cursor right/Op on
5. On/Off and keyboard light
6. Decrease se ng
7. Cursor le /Op on
8. Enter to save selected se ng
and select ac ve cursor
9. Set/Sel to select screen op ons
BEFORE USE READ THE FULL INSTRUCTION MANUAL
WHICH IS AVAILABLE TO DOWNLOAD FROM OUR
WEBSITE.
www.bicommunica ons.co.uk
DO NOT USE ON LIVE OR ACTIVE CIRCUITS
Opera on
Power ON – Press key (5) and release, Power OFF
press key (5) and hold for 2 seconds
Key Pad Illumina on- press key (5) to Turn on/off .
If the unit is fi ed with new ba eries, or the ba eries
have been removed and refi ed a message will appear
for the user to select the ba ery type press keys (3 / 6)
to highlight the ba ery type, press key (9) to select.
The main menu –
1. Measurements
2. Se ngs
3. Help
To select a menu op on, use keys (3 / 6) to highlight,
press key (8) to select.
Measurements this is the measurement screen, the
parameters listed below are displayed along the top
and the right-hand side of the display these may be
changed as follows,
to select Press key (5) un l parameter is highlighted
press keys (3 / 6) to change value
Impedance – selectable for 25,50,75 and 120
ohms
VoP- selectable between 1 and 99% or feet/
meters per microsecond
RANGE-Selectable from 7meters to 6Km or Feet
(11 range scales)
Scan mode select between Cont, Once or Tone
CURSOR MODES C1, C2 – The TDR can be operated on
single cursor C1 (RED) or dual cursor C2 (GREEN), to
move the cursor to fault posi on on cable use keys (4/
7). When in Dual cursor mode keys (4/7) default to C1
cursor. To change between cursors, press (8). A small
arrow will be shown on the top of the selected cursor.
The distance between cursors is displayed in bo om
right of display.
GAIN To change gain value press keys (3/7)
?A range of fault condi ons may be superimposed on
the screen, to scroll through these Press keys (3/6)
To exit TDR mode – Press key (2),
SETTINGS MENU
VoP unit, % or meters / feet per m/s
Length unit, meters or feet (the VoP will be displayed in
the unit selected)
Display brightness, high, medium or low
Auto Shutdown, disabled or 1,3,5,10,15, minutes
Language, English, Polish, German and Spanish
Press keys (3 / 5) to highlight op on, keys (4 / 7) to
change se ng, to exit screen press key (2)
HELP This lists a number of cable types with their
impedance and VoP values
1 2 3