Biamp Vocia PSKIT-1 User manual

Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.com
Vocia®
Paging Station Kit 1
(PSKIT-1)
Manual
December 2013

2
2
Important Safety Instructions
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this product near water.
6) Clean only with dry cloth.
7) Do not block ventilation openings. Install in
accordance withthe manufacturer’sinstructions.
8) Do not install near any heat sources such as
radiators, heat registers, stoves, or other product
(including amplifiers) that produce heat.
9) Do not defeat the safety purpose of the
grounding-type plug. A grounding type plug has
two blades andathird grounding prong.
The third prong is provided for your safety. If the
provided plug does notfit into your outlet, consult
an electrician for replacement of the obsolete
outlet.
10)Protect the power cord from being walked on or pinched,
particularly at plugs, convenience receptacles and the point
where they exit from the product.
11)Only use attachments/accessories specified by the
manufacturer.
12)Use only with equipment rack, cart, stand
or table designed to provide adequate
mechanical strength, heat dissipation and
securement to the building structure.
When a cart is used, use caution when moving
the cart and product combination to avoid injury from tip-over.
13)Unplug this product during lightning storms or when
unusedfor long periods of time.
14)Refer all servicing to qualified service personnel.
Servicing is required when the product has been damaged in
any way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the product, the
product has been exposed to rain or moisture, does not
operate normally, or has been dropped.
Explanation of Graphical Symbols:
Lightning Bolt: Hazardous Live voltages present when this unit is in operation. Do not touch terminals marked
withthis symbol whilethe unit is connected tolive power.
Exclamation Point: Replace components (i.e. fuses) only withthe values specified by the manufacturer.
Failure to do so will compromise safe operation of this unit.
Hazardous Moving Fan Blades: Remove power before servicing and keep away from moving fan blades.
WARNING - To reduce the risk of fire or electric shock, do not expose these products to rain or moisture. These products
must not be exposedto dripping or splashing and no objects filled withliquids, such as vases, shall be placed on these
products.
WARNING – 100 Volt Speaker terminals marked with the symbolare Hazardous Live. External wiring connected to
these terminals requires installation by a Skilled or Instructed Person.
WARNING – MAINS Powered Products employ Safety Grounding and must be connected to a MAINS socket that is properly
grounded to provide a protective earthing connection.
Disconnect Device - The MAINS plug is used to disconnect MAINS power and must remain readily operable.
CAUTION – When POTS Telephone Interface options are provided, connections to the telecom circuits of this device must
be made by qualified, trained personnel. To reduce the risk of fire, use only No. 26 AWG solid copper wire for telecom circuit
connections.
Intended for Installation and Service by Skilled Personnel Only:
CAUTION – To reduce the Risk of Electric Shock, Installation and Service of Biamp Products should be conducted only by
Skilled Persons who are Biamp Qualified Audio Installation Professionals.
Do not perform any servicing other than that contained in the Operating Instructions unless you are a Skilled Person
qualified to do so.
Skilled Persons must disconnect AC MAINS Power before opening product.
CAUTION - The Installation steps for ‘Auxiliary Power’ are for use by Skilled Personnel only and must comply with all local
codes.
•National Electrical Code, ANSI/NFPA 70 for United States.
•Canadian Electrical Code, Part 1, CSA C22.1, Sections 2-128, 12-010(3) and 12-100 for Canada.
Wall Mounting Instructions – Wall-mounted products must be securely fastened to drywall or similar surface using a
minimum of 4 wood screws (2 screws for product with only two mounting holes). Alternate fasteners which may be used
include Drywall Anchors, self-tapping sheet metal screws located in metal studs or wood screws extending minimum inch
into wood studs.
IMPORTANT SAFETY INSTRUCTIONS

3
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS ..........................................2
VOCIA PAGING STATION KIT (PSKIT-1) .........................................4
Features ................................................................................4
FRONT PANEL ..............................................................5
Setup And Use ...........................................................................5
Power Indicator ...........................................................................5
CONNECTIONS ............................................................................5
Power ..................................................................................5
Microphone ..............................................................................5
Ptt Input.................................................................................6
General Purpose Inputs ....................................................................6
General Purpose Outputs ...................................................................6
Rs-232..................................................................................7
Aux Port ................................................................................7
Cobranet Led Indication ....................................................................7
Device Id Switches ........................................................................7
PSKIT-1 SPECIFICATIONS ....................................................8
WARRANTY ................................................................9
FCC NOTICE...............................................................10
EC DECLARATION OF CONFORMITY ..........................................11
ROHS COMPLIANCE AND HAZARDOUS SUBSTANCE TABLE .....................12

4
VOCIA PAGING STATION KIT (PSKIT-1)
The PSKIT-1 is a standalone Paging Station Kit designed to allow for direct connection to third-party equipment such as reman’s
microphone stations or custom designed re panels. The PSKIT-1 feature embedded DSP and on-board memory to support standard and
advanced public address and mass notication functionalities. The PSKIT-1 can store 999 user-congurable Page Codes. Additionally, all
device-specic conguration information is stored locally, which means the PSKIT-1 does not rely on a centralized controller for processing
and Page routing. Thus all the processing, routing and storage functionality in a Vocia system remains decentralized. This eliminates a
single point of system failure and permits redundancy to be built directly into the network. As part of a Vocia system, the PSKIT-1 meets
paging requirements for facilities of all sizes.
FEATURES
• Up to 999 user-congurable Page Codes
• 8 priority levels: 4 regular priority levels, 4 emergency
priority levels
• Local digital signal processing, including gain, lters,
and compressor/limiter
• Local storage of conguration data
• Local storage of default and/or custom chimes
• Built-in store and forward functionality
• CobraNet®audio/control, plus power on single cable
• Dual/Redundant Powering (PoE, 24V DC)
• RS-232 control of functionality for third-party control systems
• Support for an optional Biamp-supplied high-quality,
handheld or gooseneck microphone
• Monitored microphone capability when using dual
capsule Vocia microphone
• 12 General Purpose Inputs
• 3 General Purpose Outputs
• Microphone and Push-to-Talk (PTT) input
• Store and forward functionality
• Sturdy, surface-mounted component housing
• Rotary ID switches for unit identication
• CE marked, UL certied and RoHS compliant
• Covered by Biamp Systems’ 5-year warranty

5
VOCIA PAGING STATION KIT (PSKIT-1) FRONT PANEL
Setup and Use
The Vocia software provides an intuitive interface for conguration, DSP equalization and programming of the PSKIT-1. The information supplied
by this manual relates to physical connections and assignment. For more details on software setup, please consult the Vocia Help File.
Power Indicator
Caution - Due to potential energy hazard, connections to the Auxiliary Power 24V DC
inputs must be made by a qualied electrician or other qualied person
The Vocia PSKIT-1 is capable of operation from both PoE and 24V DC power. If both are being used, PoE power is given priority. The
Power Indicator LED behaves in the following manner:
LED Description
None No power
Solid green Powered
CONNECTIONS
Power
The PSKIT-1 supports powering via 802.3af or 802.3at (Type 1) PoE switches or external PoE Supplies. Alternatively the
device can be powered using the Power connector and an external 24V DC supply. Both supplies can be connected at the
same time without affecting the unit. Upon loss of one power source the unit automatically switches to the other source without
interrupting device operation.
Microphone
A microphone may be connected using the external 3-pin balanced microphone input provided. The default nominal input
level is -50dBu. Phantom power is not available on this input. If using this input, the microphone and its connection will not
be monitored.
The PSKIT-1 also includes a 5-pin internal connector for supporting a Biamp monitored microphone (optional accessory). This connection
is not accessible from the outside of the enclosure and must only be used with a Biamp supplied microphone. If the internal connector is
being used with a monitored microphone, the LK1 and LK2 jumpers must be removed. By default the jumpers are installed, which disables
the monitoring functionality so that a standard (3-pin) microphone may be used.
Do not use both the internal and external microphone connections at the same time.

6
VOCIA PAGING STATION KIT (PSKIT-1) FRONT PANEL
PTT Input
The Push-to-Talk function will be activated when the PTT pin is connected to Ground.
General Purpose Inputs
The PSKIT-1 supports 12 unmonitored Control Inputs for connection to a keypad interface numbered 0 through 9, as well as inputs for a Next
and Previous scroll button. Each Control Input is activated with a momentary connection to Ground. Only one pin can be selected at once.
Pin Labeled Assignment
1 Ground
2 1 Keypad 1
3 2 Keypad 2
4 3 Keypad 3
5 4 Keypad 4
6 Ground
7 5 Keypad 5
8 6 Keypad 6
9 7 Keypad 7
10 8 Keypad 8
11 Ground
12 9 Keypad 9
13 10 Keypad 0
14 11 Next Scroll
15 12 Previous Scroll
General Purpose Outputs
Two General Purpose Outputs are used to indicate the Wait and Talk states.
Once the PTT is active the “Wait” output will assert while the system establishes the necessary audio paths, checks for zone availability
and plays the chime (if selected). The “Talk” output will assert once the audio path is live.
Pin Labeled Assignment
1 Ground
2 1 Wait
3 2 <not currently in use>
4 3 Talk
5 12V 12V DC (100mA)

7
VOCIA PAGING STATION KIT (PSKIT-1) FRONT PANEL
RS-232
A female RS-232 serial port is provided for Vocia Text Protocol (VTP) connectivity. Please refer to the software help le for all supported
commands.
Pin Out Function
Pin 2 Transmit Data TXD output
Pin 3 Receive Data RXD input
Pin 5 GND / 0V
Aux Port
A RJ-45 connector is available internally for use with Biamp accessories. This port is not an Ethernet port and must not be connected to a
switch, PoE supply, or other Ethernet network devices.
Network Connection
The PSKIT-1 is a CobraNet device and uses the RJ-45 connector for communications with other Vocia devices. It is possible to use this
network connection with an 802.3af or 802.3at (type 1) PoE switch or external PoE Supplies to provide power to the device. Alternatively,
if the device is being powered using the Power Connector and an external 24V DC supply, a connection to the CobraNet network must
still be available for the device communications. All CobraNet routing and bundle assignments are processed by the Vocia devices locally.
Vocia makes dynamic use of available bundles in CobraNet. A 100Base-T Ethernet switch (not repeater hub) is required when networking
multiple units. CobraNet utilizes standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specied maximum length of 328 feet (100
meters). Additional Ethernet switches, or switches which provide ber-optic interface, can be used to extend the physical distance between
units within a network. Please note that CobraNet limits network extensions to 7 hops (one-way transmissions) within a network. The RJ-45
connector provides two LEDs that indicate Ethernet link and network activity.
Left LED Right LED Description
None None No Data Connectivity or CobraNet activity.
Amber Flashing green Link established and CobraNet activity detected. The unit is acting as
the CobraNet Performer.
Flashing amber Flashing green Link established and CobraNet activity detected. The unit is acting as
the CobraNet Conductor.
Flashing amber None CobraNet fault. Check cabling and conguration for errors.
Device ID switches
The rotary ID switches are located on the front of the unit and are used to provide a unique Device ID. The
switches are in hexadecimal format. All Vocia units of the same type must have a unique Device ID to function
properly within a Vocia Paging World (for instance, it is not possible to have two Vocia Devices of the same
type with the same Device ID of hex 07).
As an example, to assign a Device ID of hex 07, turn the LSB switch to 7 and leave the MSB switch on 0. To create an ID of hex B7, turn the
LSB switch to 7 and turn the MSB switch to B. Device ID switches should be set using a 0.1 inch (2.5mm) to 0.12 inch (3.0mm) at blade
screwdriver. More information on setting IDs and the hexadecimal numbering scheme used can be found in the Vocia Software Help File.

8
VOCIA PAGING STATION KIT (PSKIT-1) SPECIFICATIONS
Frequency Response: +0, -1dB, 100Hz to 20kHz
Effective Input Headroom: 30dB
Gain: Adjustable in 1dB steps over a 30dB range
System Headroom: 18dB
Nominal Input Level: -50dBu
THD + N: <0.05% 20Hz to 8kHz
General Purpose Inputs:
Quantity: 12
Type: Contact Closure / TTL
TTL Logic Low: 0 – 0.8V
TTL Logic High: 2 – 5V
General Purpose Outputs:
Quantity: 3
Max Continuous Current: 200mA
Max External Supply: 40V
Reference Output: 12V DC 100mA
RS-232:
Baud: 57600 bps
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
A/D Converters: 24-bit (48kHz sampling)
Connection: RJ-45 with shielded Ethernet
(CAT5, CAT5e, CAT6 or CAT7)
PoE Power: 802.3at Type 1 Class 2
DC Power: 24V DC 6W
Overall Dimensions:
Height: 1.6” (40.6mm)
Width: 5.24” (133mm)
Length: 11.54” (293mm)
Weight: 2.25lb (1.02kg)
Ambient Operating Temperature Range: 32-113º F (0–45º C)
Altitude: 0–10,000 feet (0-3000 meters)
Humidity: 0% to 95% non-condensing
Compliance: CE marked (Europe)
RoHS Directive (Europe)
UL Certified Safety
E215636 (US, Canada)
FCC Part 15B (USA)
RCM (Australia)
EAC (Eurasian Customs Union)
Vocia Paging Station Kit Interface 1 SPECIFICATIONS

9
BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF
THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL
1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and
workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the
terms and conditions set forth below.
2 If you notify BIAMP during the warranty period that a BIAMP Systems product fails to comply with the warranty, BIAMP Systems
will repair or replace, at BIAMP Systems’ option, the nonconforming product. As a condition to receiving the benets of this warranty,
you must provide BIAMP Systems with documentation that establishes that you were the original purchaser of the products. Such
evidence may consist of your sales receipt from an authorized BIAMP Systems dealer. Transportation and insurance charges to
and from the BIAMP Systems factory for warranty service shall be your responsibility.
3. This warranty will be VOID if the serial number has been removed or defaced; or if the product has been altered, subjected to
damage, abuse or rental usage, repaired by any person not authorized by BIAMP Systems to make repairs; or installed in any
manner that does not comply with BIAMP Systems’ recommendations.
4. Electro-mechanical fans, electrolytic capacitors, gooseneck microphones, cords connecting handheld microphones, hard-drives,
displays, and normal wear and tear of items such as paint, knobs, handles, keypads and covers are not covered under this
warranty. All server-based devices are warranted for 3 years only.
5. This warranty is in lieu of all other warranties, expressed or implied. Biamp Systems disclaims all other warranties, expressed or
implied, including, but not limited to, implied warranties of merchantability and tness for a particular purpose.
6. The remedies set forth herein shall be the purchaser’s sole and exclusive remedies with respect to any defective product.
7. No agent, employee, distributor or dealer of Biamp Systems is authorized to modify this warranty or to make additional warranties
on behalf of Biamp Systems. Statements, representations or warranties made by any dealer do not constitute warranties by Biamp
Systems. Biamp Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or
other person.
8. No action for breach of this warranty may be commenced more than one year after the expiration of this warranty.
9. Biamp systems shall not be liable for special, indirect, incidental, or consequential damages, including lost prots or loss of use
arising out of the purchase, sale, or use of the products, even if BIAMP Systems was advised of the possibility of such damages.
585.0404.90A
WARRANTY

101010
FCC NOTICE - CLASS B DIGITAL DEVICE
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential as well as in a commercial
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1) Reorient or relocate the receiving antenna, 2) Increase the separation between the equipment and receiver, 3) Connect the equipment
into an outlet on a circuit different from that to which the receiver is connected or 4) Consult the dealer or an experienced radio/TV
technician for help.
FCC COMPLIANCE

11
COMPLIANCE
12
DoC PSK201311
EC Declaration of Conformity
Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares
that our delivered version of the following described product complies with the applicable
provisions of the DIRECTIVES below except as noted herein. Any alterations to the product
not agreed upon and directed by Biamp Systems Corporation will invalidate this declaration.
Brand Name: Vocia®
Product Description: Paging Station Control Interface
Model: PSKIT-1
Applicable EC Directives: Applicable Harmonized Standards:
LVD Directive (2006/95/EC) Safety EN 60065:2002, A1:2006,
A11:2008, A2:2010, A12:2011
EMC Directive (2004/108/EC) Emissions EN 55103-1:2009, Environment E2
Immunity EN 55103-2:2009, Environment E2
RoHS Directive (2011/65/EU) RoHS Recast
Special Considerations for Product Environment or Compliance:
•Use only CE marked Power over Ethernet (PoE) power supply and/or DC power supply.
•Shielded cabling must be used for system connections.
Technical Construction File, Location and Contact:
Biamp Systems Corporation phone: +1 503.641.7287
9300 S.W. Gemini Drive fax: +1 503.626.0281
Authorized Representative: Larry Copley, Compliance Engineer
Authorized Signature:
Date and Place Issued: November 2013, Beaverton, Oregon USA

12
COMPLIANCE
13
RoHS Compliance and Hazardous Substance Table
This Biamp product, including all attendant cables and accessories supplied by Biamp, meets all
requirements of EU Directives 2011/65/EU.
The information below is presented in accordance with parallel requirements of Chinese law
SJ/T11363-2006.
gH©£
Biamp Systems Corporation
#L¤ (Announcement Station)
Vocia PSKIT-1
©W
²7
Pb
·
Hg
w
Cd
½
Cr+6
$º
PBB PBDE
§Ci(Equipment Chassis)X O X O O O
b\RaG (Plug-in Terminal Blocks) O O O O O O
ZM (Cable Ties) O O O O O O
! (CD ROM) O O O O O O
Y':%Äco (Manual and Paper Documents) O O O O O O
.¤:Xg.¤kd (Box and Packing Materials) O O O O O O
0£¨²Xg?©kd®gsgH© SJ/T11363-2006 À,¥v.
X£¨²¡Jg?©kdX8®gsgH©Æ SJ/T11363-2006 À,¥v.
>¦F:W¼½X8?©kd½3%/68³5ª 0.01%p] 91/338/EECn_p]
76/769/EECÀ,»;:m0©:,-²+Xq±ÁD
>WE©X8?©kd·3%/68³5ª 0.1%:
1) G <&X8·
2) ·>¶kf6´ 8³5¬ 0.35%
3) ·>¹kf6´ 8³5¬ 0.4%
4) ·>¸kf6´ 8³5¬ 4%
5) Æd·1·d6´·8³ª 85%
6) Gò&·
7) VdX8·°aµ:TB<.¤%
·8³ª 80% 85%
8) ÅPµ°a&·
9) I«¾SV°d
>rNU(=hÀ 10 Olf
• A|Q 0-40C (32-104°F)
• }Q 0-95%e*
• z\ÆQ 0-2000-
• ty4¿
• xguW%{¯"²
• ~ IEEE 802.3af PoEClass 2 :24VDC, 6W
• ²xg^@^@²P1
• K2`j9[)kd¯¢Xg
Other manuals for Vocia PSKIT-1
2
This manual suits for next models
1
Table of contents
Other Biamp Microphone manuals

Biamp
Biamp Vocia DS-4 User manual

Biamp
Biamp Tesira TCM-1 User manual

Biamp
Biamp Vocia PSKIT-1 User manual

Biamp
Biamp NPX H1040 Original operating instructions

Biamp
Biamp Parlé TTM-X Original operating instructions

Biamp
Biamp Vocia WS-4 User manual

Biamp
Biamp Vocia GPIO-1 User manual

Biamp
Biamp DCM-1 User manual

Biamp
Biamp Vocia WS-10 User manual

Biamp
Biamp Vocia PSKIT-1 User manual