Bien Air CAP 15:1 Prophy User manual

English
Fully Swiss-manufactured devices.
Type
Dental contra-angle and handpiece, with internal
spray.
Description CAP 15:1 Prophy
Contra-angle without light, for interchangeable
cups.
Description PMP 10:1 Prophy
Handpiece without light, for interchangeable
heads.
Planned use
Product intended for professional use only. Use in
dentistry for prophylaxis work.
Technical data and assembly
Classification
Class IIa in accordance with European Directive
93/42/CE in accordance with medical directives.
Type of coupling
The most commonly used coupling in the world as
per ISO Standard3964.
Drive
The instrument can be coupled to an air-driven or
electric micromotor.
Dimensions
CAP 15:1
Ø19.6 mm (0.77 in)
total length 88.5 mm (3.5 in)
PMP 10:1
Ø19.6 mm (0.77 in)
total length without head 68 mm (2.68 in)
Possible input value
Up to 40 000 rpm
Recommended working speed
400 to 600 rpm
Transmission ratio
CAP 15:1
15:1 reduction
PMP 10:1
10:1 reduction
Cup, brush
With screw type M1.8 or clip type M1.8
Head for PMP 10:1
Doriot type head, disposable straight and angled
Fitting the screw cup
fig. 1
Disassembling the screw cup
Leave the CAP on the motor
fig. 2
Fitting the clip cup
fig. 3 and 5
Disassembling the clip cup
Leave the CAP on the motor
fig. 4-5
Fitting the head
Only for PMP 10:1
fig. 6
Disassembling the head
Only for PMP 10:1
fig. 7
Important
Never mount an instrument on a rotating motor.
Maintenance
Separately clean, lubricate and sterilise the
device before the treatment of each patient.
Only use maintenance products and components
from Bien-Air. The use of other products and com-
ponents can void the guarantee.
The instrument is delivered “non sterile”. Before
first use, lubricate and sterilize the instrument.
Please comply with these instructions.
Check that the steriliser and the water that is used
are clean. After each sterilisation cycle, remove the
device from the sterilizing apparatus immediately,
in order to reduce the risk of corrosion.
Overhaul
Never disassemble the device. For all modifications
and repairs, we recommend that you contact your
regular supplier or Bien-Air direct. Bien-Air asks
the user to have its dynamic instruments checked
or inspected at least once a year thereafter.
Cleaning
Use Spraynet cleaner from Bien-Air
fig. 8
. Spray
the inside and outside of the equipment to remove
the residues and carefully clean the surfaces.
Disinfection
Disinfect using a clean cloth soaked in a suitable
product. Products containing acetone, chlorine
and bleach are not recommended as disinfectants.
Never immerse in disinfectant solutions.
Not suitable for ultrasonic bath.
Before sterilisation
Remove residue, carefully clean the device. Lubri-
cate instrument.
Lubrication
Only use Lubrifluid spray.
•Remove tool from instrument gripper before
lubrication
•Place the instrument in a cloth so as to catch
the debris and foreign matter expelled by the
atomizer jet.
•Removethe protectivecap and insertthe nozzle
into the back of the instrument sleeve.
•Spray for about 1 second
fig. 9
.
Sterilisation
Process: Steam autoclave up to 134°C (273°F).
The required time for sterilisation of our products
must comply with the prevailing local regulations
for this type of instrument.
Important
After lubrication, always place the instrument with
the head downwards in order to allow the lubricant
to spread well through the whole mechanism and
to prevent any infiltration of the oil into the micro-
motor when the instrument is attached to it.
Important
After cleaning and disinfecting/ sterilizing
the instrument and before using it, operate
at moderate speed, with a bur in the chuck,
REF 2100050-ENG/05.08
CAP 15:1 Prophy
PMP 10:1 Prophy
ENG Instruction
REF 2100050-ENG/05.08 1/2
for 10 to 15 seconds to circulate lubricant
and remove excess.
Environment
Temperature between -40°C (-40°F) and 70°C
(158°F), relative humidity between 10% and
100%, atmospheric pressure 50 kPa to 106 kPa
(7.3 to 15.3 psi).
Information
The technical specifications, illustrations and di-
mensions contained in these instructions are given
only as a guide. They may not be the subject of any
claim. The manufacturer reserves the right to
make technical improvements to its equipment,
without amending these instructions. The French
original of this text conforms to the legal
standards. For all additional information, please
contact Bien-Air at the address indicated on the
reverse.
General information
The device must be used by a competent person in
accordance with the current legal provisions con-
cerning industrial safety, health and accident pre-
vention regulations, and these working instruc-
tions. In accordance with these requirements, the
operators:
•must only use operating devices that are in per-
fect working order; in the event of irregular fun-
ctioning, excessive vibration, abnormal heating
or other signs indicating malfunction of the
device, the work must be stopped immediately;
in this case, contact a repair centre that is
approved by Bien-Air;
•must ensure that the device is used only for the
purpose for which it is intended, must protect
themselves, their patientsand thirdparties from
any danger, and must avoid contamination
through the use of the product.
The device is intended for medical treatment only;
any use other than that for which this product is
intended is unauthorised and may be dangerous.
The medical device meets all the current European
legal requirements.
Excess material from productsused for mainten-
ance (lubricants, cleaning products and disinfec-
tants) originating from CA or PM may penetrate
into the electric brush motor and interfere with its
functioning. It is essential to follow the mainten-
ance instructions accompanying each product.
Never lubricate the electric brush motor.
Recommendations
Adhereto the Instructions for Use, in accordance
with the instructions of the tool manufacturer.
Never use a tool with an incorrect rod, as there is a
risk of this becoming detached during the treat-
ment and causing injuryto you yourself, to your
patient and to third parties.
Rest the device on a suitable support to avoid risks
of infection for yourself,the patient or third parties.
Only use maintenance products and components
from Bien-Air. The use of other products and com-
ponents can void the guarantee.
Guarantee
Terms of guarantee
Bien-Air grants the operator a guarantee covering
all functional defects, material or production
faults.
The device is covered by this guarantee for
12 months from the date of invoicing.
In the event of justified claims, Bien-Air or itsaut-
horised representative will fulfil the company’s ob-
ligations under this guarantee by repairing or re-
placing the product free of charge. Any other
claims, of whatever nature, in particular in the
form of a claim for damages and interest, are
excluded.
Bien-Air shall not be held responsible for damage
or injuryand the consequences thereof, resulting
from:
• excessive wear and tear
0120
fig. 8
fig. 5
fig. 7
fig. 4
fig. 9
fig. 6
fig. 2
fig. 1
fig. 3
1sec.
1sec.
Bien-Air Dental SA
Länggasse 60
Case postale 6008
2500 Bienne 6, Switzerland
Tel. +41 (0)32 344 64 64
Fax +41 (0)32 344 64 91
office@bienair.com
Bien-Air Deutschland GmbH
Jechtinger Strasse 11
79111 Freiburg, Deutschland
Tel. +49 (0)761 45 57 40
Fax +49 (0)761 47 47 28
ba-d@bienair.com
Bien-Air España SA
Entença, 169 Bajos
08029 Barcelona, España
Tel. +34 934 25 30 40
Fax +34 934 23 98 60
ba-e@bienair.com
Bien-Air USA, Inc.
Medical Technologies
5Corporate Park
Suite 160
Irvine, CA 92606 USA
Phone 1-800-433-BIEN
Phone 949-477-6050
Fax 949-477-6051
ba-usa@bienair.com
Bien-Air France Sarl
131, BoulevardPéreire
75017 Paris, France
Tel. +33 (0)1 47 64 13 49
Fax +33 (0)1 40 54 91 43
ba-f@bienair.com
Bien-Air Italia s.r.l.
Via Vaina 3
20122 Milano, Italia
Tel. +39 (02) 58 32 12 51/52/54
Fax +39 (02) 58 32 12 53
ba-i@bienair.com
Bien-Air UK Limited
63, The Street Capel,
Surrey RH5 5JZ, England
Tel. +44 (0)1306 711 303
+44 (0)1306 712 505
Fax +44 (0)1306 711 444
ba-uk@bienair.com
Bien-Air Asia Ltd.
Nishi-Ikebukuro
Daiichi-Seimei Bldg. 10F
2-40-12 Ikebukuro, Toshimaku
Tokyo, 171-0014, Japan
Tel. +81 (3) 5954-7661
Fax +81 (3) 5954-7660
ba-asia@bienair.com
Beijing Bien-Air
Medical Instruments
Technology Service Co. Ltd.
Room 2106,
The Exchange Beijing
Yi 118 Jianguo Road
Chaoyang District
Beijing 100022, China
Tel. +86 10 6567 0651
Fax +86 10 6567 8047
ba-beijing@bienair.com
REF 2100050-ENG/05.08 2/2
Optional accessories
Set supplied
In these instructions, “Device” corresponds to the product described in the
heading “Type”. For example, turbine, contra-angle, handpiece, micromo-
tor, tube, electronics, connectors, station etc.
List of Bien-Air registered trade mark products ®:
REF Legend
1600289-001 Handpiece PMP 10:1 Prophy without light and without
spray, with 10x reducer, for standard disposable heads.
Set comprising: • 1 PMP 10:1 Prophy • 2 straight heads
1600290-001 Contra-angle CAP 15:1 Prophy, without light and without
spray, 15x reducer, interchangeable cups: clip-on or screw
Set comprising: • 1 CAP 15:1 Prophy • 5 screw cups
• 5 clip-on cups
1100056-100 Interchangeable heads for PMP 10:1
Set comprises 100 straight heads
1302631-010 Clip cup support
107.60.03 Screwdriver
107.60.05 Key for nut
1600064-006 Lubrifluid, lubricant 500 ml, box of 6 cans
1600036-006 Spraynet, cleaning spray 500 ml, box of 6 cans
This product may be covered by one or more of the following patents:
EP Europe: 0497 139 / 0 526 783 / 0 745 358 / 0 688 539 / 0 894 879 / 1 145 688 / 1 109 301 DE Germany: 296 16 023.7
DK Denmark: 96 00315 FR France: 2679 804 / 2 722 972 / 2 733 680 / 2 692 621 / 2 720 263 / 2 757 763 / 2 766 697 / 2 781 318
CH Switzerland: 693 922 CN China: 129343 JP Japan: 2037 611 / 1 991 770 US United-States: 5.059.122 / 4.773.856 /
6.033.220 /6.337.554 / 5.453.008 / 6.319.003 / 6.495.937
REF 1600290-001 CAP 15:1 PROPHY / REF 1600289-001 PM 10:1 PROPHY
Aquilon®
Bora®
Boralina®
Eolia®
Gyro®
Gyrolina®
Isolite®
Lubrifluid®
Lubrimed®
MX®
Prestilina®
Spraynet®
• improper use
• non-observance of the instructions for installa-
tion, operation and maintenance
• unusual chemical, electrical or electrolytic
influences
•poor connections, whether of the air, water or
electricity supply.
The guarantee does not cover flexible “fibre optic”
type conductors, or any parts made of synthetic
materials.
The guarantee shall become null and void if the
damage and its consequences are due to improper
manipulation of the product, or modifications to
the product carried out by persons not authorised
by Bien-Air.
Claims under the terms of the guarantee will be
considered only on presentation, together with the
product, of the invoice or the consignment note, on
which the date of purchase, the product reference
and the Serial No. should be clearly indicated.
Symboles
Wear rubber gloves
Move fully to the stop,
in the direction indi-
cated
Move in the direction
indicated
0120
CE Marking with number
of the notified body
REF 1302631-010 REF 1100056-100 REF 1600064-006
6x
REF 1600036-006
6x
10x
100x
CAP 15:1 Prophy
REF 1600290-001
PMP 10:1 Prophy
REF 1600289-001

This manual suits for next models

1

Other Bien Air Dental Equipment manuals

Bien Air Micromotor MX User manual

Bien Air

Bien Air Micromotor MX User manual

Bien Air OPTIMA INT User manual

Bien Air

Bien Air OPTIMA INT User manual

Bien Air CHIROPRO 3rd Gen Series User manual

Bien Air

Bien Air CHIROPRO 3rd Gen Series User manual

Bien Air S001 User manual

Bien Air

Bien Air S001 User manual

Bien Air CA 1: 2.5 L MS User manual

Bien Air

Bien Air CA 1: 2.5 L MS User manual

Bien Air CA 1:2.5 L MS User manual

Bien Air

Bien Air CA 1:2.5 L MS User manual

Bien Air CA 1:1 User manual

Bien Air

Bien Air CA 1:1 User manual

Bien Air 1601098-001 User manual

Bien Air

Bien Air 1601098-001 User manual

Bien Air CA 1: 2.5L MS User manual

Bien Air

Bien Air CA 1: 2.5L MS User manual

Bien Air MC2 Series User manual

Bien Air

Bien Air MC2 Series User manual

Bien Air Chiropro Plus 3rd Gen User manual

Bien Air

Bien Air Chiropro Plus 3rd Gen User manual

Bien Air iOptima INT User manual

Bien Air

Bien Air iOptima INT User manual

Bien Air OPTIMA INT User manual

Bien Air

Bien Air OPTIMA INT User manual

Bien Air Lubricare 2 HIM-2 User manual

Bien Air

Bien Air Lubricare 2 HIM-2 User manual

Bien Air iOptima User manual

Bien Air

Bien Air iOptima User manual

Bien Air iOptima User manual

Bien Air

Bien Air iOptima User manual

Bien Air TD 783 User manual

Bien Air

Bien Air TD 783 User manual

Bien Air iOptima User manual

Bien Air

Bien Air iOptima User manual

Bien Air CA 1:1 User manual

Bien Air

Bien Air CA 1:1 User manual

Popular Dental Equipment manuals by other brands

Vatech PaX-i3D Smart installation manual

Vatech

Vatech PaX-i3D Smart installation manual

NSK Ti-Max Ti-SG65L Operation manual

NSK

NSK Ti-Max Ti-SG65L Operation manual

Bien-Air Dental CA NOVA 1:1L Instructions for use

Bien-Air Dental

Bien-Air Dental CA NOVA 1:1L Instructions for use

KERR ENDODONTICS elements 8:1 Instructions for use

KERR ENDODONTICS

KERR ENDODONTICS elements 8:1 Instructions for use

DENTSPLY Cavitron Directions for use

DENTSPLY

DENTSPLY Cavitron Directions for use

Poldent Endostar Instructions for use

Poldent

Poldent Endostar Instructions for use

NewTom VGi Technical instructions

NewTom

NewTom VGi Technical instructions

Tecno-gaz Europa B EVO Instructions for use

Tecno-gaz

Tecno-gaz Europa B EVO Instructions for use

Muss Dental MA 50 operation instruction

Muss Dental

Muss Dental MA 50 operation instruction

Aseptico ADU-04 Operation and maintenance instruction manual

Aseptico

Aseptico ADU-04 Operation and maintenance instruction manual

Vatech PaX-500 user manual

Vatech

Vatech PaX-500 user manual

Komet SFS120 Instructions for use

Komet

Komet SFS120 Instructions for use

ASI 90-2115 Operation & service manual

ASI

ASI 90-2115 Operation & service manual

Kulzer Dima Instructions for use

Kulzer

Kulzer Dima Instructions for use

NSK PTL-CL-LED Operation manual

NSK

NSK PTL-CL-LED Operation manual

Dentatus Profin pdx Instruction and maintenance

Dentatus

Dentatus Profin pdx Instruction and maintenance

B.A. International BA Optima Operation manual

B.A. International

B.A. International BA Optima Operation manual

Finally White URLT999 user guide

Finally White

Finally White URLT999 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.