Bien Air TD 783 User manual

REF 2100038-ENG/12.10 1/2
REF 2100038-ENG/12.10
TD 783 / TDS 890
STS Trimmer S001 Without
module
Pressure of the Pressure of the (on the unit)
pressure gauge pressure gauge in bar
in bar in bar
TD 783 / TD 783 2-hole – 3 2,5
TDS 890 4-hole 4,8 – 2,5
4-hole REF 1600243-001
3-hole REF 1600242-001
Do no s erilise
f
ig. 1
fig. 6
fig. 4
fig. 2
fig. 7
fig. 5
fig. 3
TD 783 1600161-001 1/8“ (3.17 mm)
TD 783 1600162-001 2V
TDS 890 1600163-001 4V
REF 1000005-001
REF 1302401-010
TD 783
TDS 890
max. 25 mm
Typ 3 / ISO 1797
Code 4-6 / ISO 6360/1
min. 11 mm
ø 1.6 mm
REF 1302403-010
2.5 bar
fig. 9
fig. 10
Lubrimed
REF 1600037-006
1/2
fig. 8
1 se .
Instruction
English
Devices entirely made in Switzerland by
Bien-Air Dental SA.
Type
Straight laboratory turbine with or without spray.
Intended use
Product intended for professional use only. Use in
for laboratory work. Any use other than that for
which this device is intended is prohibited and may
prove dangerous.
Technical data
Coupling
2- or 4 hole pressure gauge and direct
fig. 1
.
Recommanded rotation speed
Up to 300,000 rpm.
Weight
60 g (2,11 oz).
Air consumption
35 normliter/min on average.
Air spray rate
2 normliter/min to 200 kPa (29 psi).
Water spray rate
100 ml/min to 200 kPa (29 psi).
Information
The technical specifications, illustrations and di-
mensions contained in these instructions are given
only as a guide. They may not be the subject of any
claim.The manufacturer reserves the right to make
technical improvements to its equipment, without
amending these instructions. For all additional in-
formation, please contact Bien-Air Dental SA at the
address indicated on the back cover.
Using
Air pressure output
Do not use the turbine at above the required
air pressure
For use without unit:
Adjust the required air pressure to 2.5 bar (36.28
psi) with the assistance of a Bien-Air Dental inspec-
tion pressure gauge - 3-hole or 4-hole version
placed between hose and connection,
fig. 1
.
For use with the S001 unit:
Please refer to the indications of the unit’s manome-
ter. The required air pressure is 3 bar (44 psi).
Important
The device must not be started without a bur in-
serted into the chuck.
Bur
Diameter of shaft 1.60 mm (0.06 in), type 3 in ac-
cordance with ISO 1797; max. length 25 mm (0.98
in), code 4-6 in accordance with ISO 6360-1
fig. 2
.
Inserting the tool
Place the bur in the turbine’s chuck
fig. 3
. Then in-
sert the turbine head in the bur securing tool, press
the bur against the metal disc in the bur securing
tool and press firmly until you hear a «clic»
fig. 4
.
Extracting the tool
old the central part of the straight turbine’s han-
dle firmly in one hand and press the rear part of the
handle forward. Release and remove the bur
fig. 5
.
Seals replacement
2V:
Remove the seal according to
fig. 6
4V:
Remove the seal according to
fig. 7
Removing seal, place it on the tubes and remount
the attachment
fig. 1
Maintenance
Non-sterilisable
Only use maintenance products and components
from Bien-Air Dental.The use of other products and
components can void the guarantee.
Servicing
Never disassemble the device. For any modification
and repair, we recommend that you contact your
regular supplier or Bien-Air Dental directly.
Bien-Air Dental asks the user to have its dynamic
instruments checked or inspected at least once a
year.
Cleaning
Use
Spraynet
cleaner
fig. 8
. Spray the inside and
outside of the equipment to remove the residues and
carefully clean the surfaces.
Never immerse in disinfectant solutions.
Not suitable for ultrasonic bath.
Lubrication
Lubrication at least twice a day
.
Only use
Lubrimed
medical grease and greaser.
• First-time use: Remove the cap, screw the
knurled back-housing until the grease appears
at the end of the rod. Wipe off surplus grease
and replace cap after use.
• Remove the bur and introduce the rod of the
greaser to the bottom. The dose corresponds to
one half-turn of the knurled backhousing. Use
the guidemarks
fig. 9
.
• Replace a bur, turn on the air and run the tur-
bine for about 15 seconds.
Important
After cleaning and disinfecting the instrument
and before using it, operate at moderate
speed, with a bur in the chuck, for 10 to 15
seconds to distribute, and remove, the excess
lubricant.
Cleaning of spray tubes
fig. 10
Wire cleaner.
Transport and storage conditions
Temperature between -40°C (-40°F) and 70°C
(158°F), relative humidity between 10% and 100%,
atmospheric pressure 50 kPa to 106 kPa (7.3 to 15.3
psi).
Other precautions for use
The device must be used by a qualified person in
accordance with the current legal provisions con-
cerning industrial safety, health and accident pre-
vention measures, and these working instructions.
In accordance with these requirements, the opera-
tors:
• must only use operating devices that are in per-
fect working order; in the event of irregular
functioning, excessive vibration, abnormal
heating or other signs indicating malfunction
of the device, the work must be stopped imme-
diately; in this case, contact a repair centre that
is approved by Bien-Air Dental;
• must ensure that the device is used only for the
purpose for which it is intended, must protect
themselves, their patients and third parties from
any danger, and must avoid contamination
through the use of the product.
Rest the device on a suitable support in order to
eliminate the risk of injury to you yourself and to
third parties.
Recommendations
It is essential to use dry, purified compressed
air in order to ensure the long working life of
the device. Maintain the quality of the air and
the water by regular maintenance of the com-
pressor and the filtration systems.
The use of unfiltered hard water will lead to
early blockage of the tubes, connectors and
spray cones.
After a period of prolonged use, the device must be
cleaned and serviced according to these instruc-
tions.
REF 2100038-ENG/12.10 2/2
Bien-Air Dental SA
Länggasse 60
Case postale
2500 Bienne 6, Switzerland
Tel. +41 (0)32 344 64 64
Fax +41 (0)32 344 64 91
office@bienair.com
Bien-Air Deutschland GmbH
Jechtinger Strasse 11
79111 Freiburg, Deutschland
Tel. +49 (0)761 45 57 40
Fax +49 (0)761 47 47 28
ba-d@bienair.com
Bien-Air España SA
Entença, 169 Bajos
08029 Barcelona, España
Tel. +34 934 25 30 40
Fax +34 934 23 98 60
ba-e@bienair.com
Bien-Air USA, Inc.
Medical Technologies
5 Corporate Park
Suite 160
Irvine, CA 92606 USA
Phone 1-800-433-BIEN
Phone 949-477-6050
Fax 949-477-6051
ba-usa@bienair.com
Bien-Air France Sàrl
55-57, avenue Jean Lolive
93508 Pantin Cedex, France
Tel. +33 (0)1 41 83 60 70
Fax +33 (0)1 48 96 07 40
ba-f@bienair.com
Bien-Air Italia s.r.l.
Via Vaina 3
20122 Milano, Italia
Tel. +39 (02) 58 32 12 51/52/54
Fax +39 (02) 58 32 12 53
ba-i@bienair.com
Bien-Air UK Limited
63, The Street Capel,
Surrey R 5 5JZ, England
Tel. +44 (0)1306 711 303
+44 (0)1306 712 505
Fax +44 (0)1306 711 444
ba-uk@bienair.com
Bien-Air Asia Ltd.
Nishi-Ikebukuro
Daiichi-Seimei Bldg. 10F
2-40-12 Ikebukuro, Toshimaku
Tokyo, 171-0014, Japan
Tel. +81 (3) 5954-7661
Fax +81 (3) 5954-7660
ba-asia@bienair.com
Beijing Bien-Air
Medical Instrument
Technology Service Co. Ltd.
Room 907, The Exchange Beijing,
No 118 Jian Guo Lu Yi,
Chao Yang District,
Beijing 100022, China
Tel. +86 10 6567 0651
Fax +86 10 6567 8047
ba-beijing@bienair.com
In these instructions, “Device” corresponds to the product described in the
heading “Type”. For example, turbine, contra-angle, handpiece, micromotor,
tube, electronics, connectors, station etc.
List of Bien-Air Dental SA registered trade mark products ®:
Aquilon®
Bora®
Boralina®
ChiroPro®
Diamline®
Eolia®
Gyro®
Gyrolina®
Isolite®
Lubrifluid®
Lubrimed®
MX2®
MX®
PowerCare®
Prestilina®
Spraynet®
REF Legend
1600161-001 TD 783 turbine for hose with internal Ø 1/8" (3,17mm),
with Friction Grip chuck (FG)
1600162-001 TD 783 turbine with 2-hole connection, Friction Grip (FG)
1600163-001 TDS 890 turbine with spray, 4-hole connection,
Friction Grip (FG)
1000005-001 Friction Grip bur-locking tool for TD 783 and TDS 890
1302401-010 Seal 3V
1302403-010 Seal 4V
1600242-001 Gauge for 3-hole attachment
1600243-001 Gauge for 4-hole attachment
1600037-006 Lubrimed medical grease cartridges, box of 6 cartridges
1000003-001 Lubrimed greaser
1600036-006 Spraynet, cleaning spray 500 ml, box of 6 cans
This product may be covered by one or more of the following patents:
E Europe: 745358 / 688539 / 948294 / 1145688 / 1563800 / 1563801 / 1675523 / 1753360 DE Germany: 29616023.7
DK Denmark: 9600315 FR France: 2722972 CH Switzerland: 693922 CN China: 100528099 / 100522100 / 100522099 /
100553584 J Japan: 3892485 / 4298933 / 7000419 US United-States: 5453008 / 6033220 / 6319003 / 7214060 / 7448870
RU Russia: 2361540 / 2361541 / 2372046
REF 1600161-001 TUR TD783 / REF 1600162-001 TUR TD783 2 / REF 1600163-001 TUR TDS890 4
Wear rubber gloves.
Attention.
CE Marking.
Move fully to the stop,
in the direction indica-
ted.
Move in the direction
indicated.
Manufacturer.
Se supplied
Op ional accessories
TD 783
REF 1600161-001
TD 783
REF 1600162-001
TDS 890
REF 1600163-001
REF 1600243-001 REF 1600242-001 REF 1600037-006
REF 1000001-010 REF 1000003-001
10x
REF 1600036-006
6x
4-hole 3-hole
REF 1302401-010 REF 1302403-010
REF 1000005-001
10x 10x
SymbolesSymbols
Adhere to the Instructions for Use, in accordance
with the instructions of the tool manufacturer. Never
use a tool with an incorrect rod, as there is a risk of
this becoming detached during the use and caus-
ing injury to you yourself and to third parties.
The device is not intended for medical treatment;
any use other than that for which this product is in-
tended is not allowed and may proved to be dan-
gerous. The device meets all the current European
legal requirements (according to the European
Directive 93/42/EEC relating to medical devices).
Guarantee
Terms of guarantee
Bien-Air Dental grants the user a guarantee cover-
ing all functional defects, material or production
faults.
The device is covered by this guarantee for
12 months from the date of invoicing.
Bien-Air Dental offers a 24-month guarantee for the
glass-bar light conductors.
In the event of justified claim, Bien-Air Dental or its
authorised representative will fulfil the company’s
obligations under this guarantee by repairing or re-
placing the product free of charge.Any other claims,
of whatever nature, in particular in the form of a
claim for damages and interest, are excluded.
Bien-Air Dental shall not be held responsible for
damage or injury and the consequences thereof,
resulting from:
• excessive wear and tear
• improper use
• non-observance of the instructions for installa-
tion, operation and maintenance
• unusual chemical, electrical or electrolytic
influences
• poor connections, whether of the air, water or
electricity supply.
The guarantee does not cover flexible “fibre optic”
type conductors, or any parts made of synthetic ma-
terials.
The guarantee shall become null and void if the
damage and its consequences are due to improper
manipulation of the product, or modifications to
the product carried out by persons not authorised
by Bien-Air Dental.
Claims under the terms of the guarantee will be
considered only on presentation, together with the
product, of the invoice or the consignment note, on
which the date of purchase, the product reference
and the Serial No. should be clearly indicated.

This manual suits for next models

1

Other Bien Air Dental Equipment manuals

Bien Air MC2 Series User manual

Bien Air

Bien Air MC2 Series User manual

Bien Air CHIROPRO 3rd Gen Series User manual

Bien Air

Bien Air CHIROPRO 3rd Gen Series User manual

Bien Air 1601098-001 User manual

Bien Air

Bien Air 1601098-001 User manual

Bien Air CA 1: 2.5 L MS User manual

Bien Air

Bien Air CA 1: 2.5 L MS User manual

Bien Air S001 User manual

Bien Air

Bien Air S001 User manual

Bien Air CA 1:1 User manual

Bien Air

Bien Air CA 1:1 User manual

Bien Air Chiropro Plus 3rd Gen User manual

Bien Air

Bien Air Chiropro Plus 3rd Gen User manual

Bien Air CAP 15:1 Prophy User manual

Bien Air

Bien Air CAP 15:1 Prophy User manual

Bien Air OPTIMA INT User manual

Bien Air

Bien Air OPTIMA INT User manual

Bien Air Lubricare 2 HIM-2 User manual

Bien Air

Bien Air Lubricare 2 HIM-2 User manual

Bien Air iOptima User manual

Bien Air

Bien Air iOptima User manual

Bien Air iOptima User manual

Bien Air

Bien Air iOptima User manual

Bien Air OPTIMA INT User manual

Bien Air

Bien Air OPTIMA INT User manual

Bien Air iOptima INT User manual

Bien Air

Bien Air iOptima INT User manual

Bien Air Micromotor MX User manual

Bien Air

Bien Air Micromotor MX User manual

Bien Air CA 1:1 User manual

Bien Air

Bien Air CA 1:1 User manual

Bien Air iOptima User manual

Bien Air

Bien Air iOptima User manual

Bien Air CA 1: 2.5L MS User manual

Bien Air

Bien Air CA 1: 2.5L MS User manual

Bien Air CA 1:2.5 L MS User manual

Bien Air

Bien Air CA 1:2.5 L MS User manual

Popular Dental Equipment manuals by other brands

Seecode 20338 manual

Seecode

Seecode 20338 manual

Amanngirrbach centrofix Series instructions

Amanngirrbach

Amanngirrbach centrofix Series instructions

Amanngirrbach Artex Instructions for processing

Amanngirrbach

Amanngirrbach Artex Instructions for processing

Amanngirrbach Artex CP user manual

Amanngirrbach

Amanngirrbach Artex CP user manual

3Disc FireCR Dental user manual

3Disc

3Disc FireCR Dental user manual

orangedental spot-on nxt Instructions for use

orangedental

orangedental spot-on nxt Instructions for use

3D Systems NextDent Cure Instructions for use

3D Systems

3D Systems NextDent Cure Instructions for use

DiO PROBO cure user guide

DiO

DiO PROBO cure user guide

NSK FX204 Series Operation manual

NSK

NSK FX204 Series Operation manual

Ancar A-3200 user manual

Ancar

Ancar A-3200 user manual

Zhermack D2 manual

Zhermack

Zhermack D2 manual

Ivoclar Vivadent Cultura Instructions for use

Ivoclar Vivadent

Ivoclar Vivadent Cultura Instructions for use

Dabi Atlante COBRA CONTRA ANGLE INTRA 32 CA owner's manual

Dabi Atlante

Dabi Atlante COBRA CONTRA ANGLE INTRA 32 CA owner's manual

KaVo INTRAmatic 10 ES Instructions for use

KaVo

KaVo INTRAmatic 10 ES Instructions for use

Renfert TOP spin quick start guide

Renfert

Renfert TOP spin quick start guide

Myray ZEN-X Instructions for use

Myray

Myray ZEN-X Instructions for use

Dentsply Sirona Nupro RDH 740000 Installation, maintenance and operation instructions

Dentsply Sirona

Dentsply Sirona Nupro RDH 740000 Installation, maintenance and operation instructions

Schick Dental QBasic operating instructions

Schick Dental

Schick Dental QBasic operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.