Bilanciai VENUS User manual

VENUS
User manual
Code 81320051 EDITION 1 December 2003


Table of Contents
1. GENERAL INFORMATION 1-7
1.1 Declaration of conformity 1-7
1.2 Foreword 1-8
1.3 Symbols 1-10
1.4 Documentation 1-11
1.5 Description of the terminal 1-11
1.6 Technical characteristics of the terminal 1-12
1.7 Overall dimensions 1-13
1.8 Obtaining technical assistance 1-13
1.9 Replacement parts list 1-14
1.10 Warranty 1-14
2. SAFETY INSTRUCTIONS 1-15
2.1 Prohibited uses 1-15
2.2 Regulations 1-15
2.3 Prescriptions for use 1-15
2.4 Professional profiles 1-17
3. DELIVERY AND INSTALLATION 1-19
3.1 Connection of the terminal to the electricity main 1-21
3.2 Connection of the terminal to the weighing platform 1-22
3.2.1 Equipotentiality between terminal and weighing platform 1-23
3.2.2 Analogue cell connection 1-23
3.3 COM1 - COM2 - COM3 serial output connection 1-24
3.3.1 RS232/RS422/RS485 configuration connections 1-24
3.4 Keyboard connection 1-26
3.5 Fast Ethernet connection 1-26
3.6 Printer connection 1-26
4. CONTROLS, DISPLAY, SWITCHING THE TERMINAL ON AND OFF 1-27
4.1 Front part (display and keyboard) 1-27
4.2 Display 1-28
4.2.1 Pathway area 1-29
4.2.2 Tare area 1-29
4.2.3 Weight area 1-29
4.2.4 Metrological data area 1-30
4.2.5 Price area 1-30
4.2.6 Message area 1-30
4.2.7 Symbol M (Metrological) area 1-31
4.2.8 Functions area 1-31
4.2.9 Date, time and level area 1-31
4.2.10 Settings area 1-31
4.3 Keyboard 1-32
4.3.1 Groups of keys 1-32
4.3.2 Function keys (orange background) 1-33
4.3.3 Date keys (purple background) 1-33
4.3.4 Summing keys (purple background) 1-33
4.3.5 Alphanumerical keys (light blue and grey background) 1-34
4.3.6 Editing keys (black background) 1-35
4.4 Switching the terminal on and off 1-38
Venus
1-3

4.4.1 BOOT phase 1-39
5. USE OF THE TERMINAL - PROGRAMMING 1-41
5.1 Convention 1-41
5.2 Operating levels 1-42
5.2.1 Introduction 1-42
5.2.2 List of levels 1-42
5.2.3 Level changes 1-43
5.2.4 Change Password 1-43
5.2.5 Access level changes on powering 1-44
5.2.6 Functions of the operating levels 1-45
5.3 Macro area 1-60
5.3.1 Introduction 1-60
5.3.2 How to program a macro function 1-60
5.3.3 How to erase a macro function 1-62
5.3.4 Macro display 1-62
5.4 User menu tree 1-63
5.5 How to program the texts 1-65
5.5.1 Introduction 1-65
5.5.2 Text archive 1-65
5.5.3 How to enter a text 1-66
5.5.4 How to copy a text 1-69
5.5.5 How to erase a text 1-69
5.5.6 How to find a text 1-70
5.5.7 Preset texts 1-70
5.6 Label programming 1-74
5.6.1 Label archive 1-74
5.6.2 How to create a label in the correct way 1-74
5.6.3 How to enter a label 1-75
5.6.4 How to copy a label 1-108
5.6.5 How to cancel a label 1-109
5.6.6 How to print a label 1-110
5.7 How to program barcodes 1-111
5.7.1 Barcode archive 1-111
5.7.2 Barcode entry 1-112
5.7.3 How to copy a barcode 1-129
5.7.4 Barcode cancellation 1-130
5.7.5 Barcodes 1-131
5.8 How to program PLUs 1-143
5.8.1 PLU archive 1-143
5.8.2 How to enter a PLU 1-155
5.8.3 How to copy a PLU 1-157
5.8.4 How to cancel a PLU 1-158
5.8.5 How to set-up the process with a variable weight 1-159
5.8.6 How to set-up the fixed weight and/or amount process 1-159
5.8.7 How to set-up the process as a labelling machine (weighing
excluded) 1-159
5.8.8 Weight range set-up 1-159
5.8.9 Piece pre-selection for total 1 (box/crate) 1-161
5.8.10 Weight pre-selection for total 1 (box/crate) 1-162
5.8.11 Piece pre-selection for total 2 (pallet) 1-163
5.8.12 Weight pre-selection for total 2 (pallet) 1-164
Venus
1-4

5.8.13 Selection of the date printing format 1-165
5.8.14 Storage days 1-167
5.9 Image programming 1-169
5.9.1 Images archive 1-169
5.9.2 How to enter an image 1-170
5.9.3 How to copy an image 1-172
5.9.4 How to cancel an image 1-172
5.9.5 Memorize in PTR 1-173
6. USE OF THE TERMINAL - PROCESS 1-175
6.1 Data modification 1-175
6.2 Basic reversal 1-175
6.3 Evolved reversal 1-175
6.4 Totals management 1-175
6.4.1 Advanced closing 1-175
6.4.2 Advanced use of totals 1-176
7. MAINTENANCE 1-177
7.1 Internal battery 1-177
7.2 How to replace the fuses 1-177
8. OPTIONS 1-179
8.1 Flash compact with adapter 1-179
8.2 Parallel output 1-179
8.3 Software options 1-180
9. TROUBLESHOOTING 1-181
9.1 Malfunctions and error messages 1-181
9.1.1 Terminal 1-181
9.1.2 Printer 1-182
Venus
1-5

Venus
1-6

1. GENERAL INFORMATION
1.1 Declaration of conformity
Venus
1-7
We SOCIETÀ COOPERATIVA BILANCIAI A.R.L.
Via S. Ferrari, 16
41011 Campogalliano - MODENA
declare upon our sole responsibility that
the Weighing indicator
VENUS and its options
described in this declaration, complies with the relevant harmonised
standards of the European Union:
2014/30/UE (EMC): EN61000-6-3:2007
EN61000-6-4:2007
2014/35/UE (LVD): EN60950-1:2006
2014/31/UE (NAWI):EN45501:1992
The terminal is also suitable for the creation of non-automatic weighing instruments approved
with the “UE Type Approval Certificate” in conformance with the requirements of Directive
2014/31/EU (NAWI). .
Campogalliano, 2/05/2016 Signed for and on behalf
of the manufacturer
The product bears CE marking.

1.2 Foreword
✔The aim of this manual is to provide the operator, through the use of
text and illustrations, with essential information regarding the
installation, safe operation and maintenance of the weighing system.
✔This manual must be kept in a safe place where it is readily available
for consultation! Always observe the instructions contained in the
manual!
✔Safe operation of the system is the responsibility of the operator, who
must be fully familiar with it.
✔The user is responsible for ensuring that the installation conforms to
the applicable regulations.
✔The equipment must only be installed by specialised personnel who
have read and understood this manual.
✔The term "specialised personnel" means any personnel who, by
virture of the training they have received and their professional
experience, have been explicitly authorised by the "System safety
supervisor" to install, operate and service the system.
✔Contact your nearest Service Centre if problems occur.
✔Any attempt on the part of unauthorised personnel to dismantle or
modify the terminal is prohibited. Any such attempt shall invalidate the
warranty and relieve the manufacturer from all liability for any damage
or injury to persons or property.
✔It is also forbidden to alter or remove the data plates and seals on the
terminal. Make sure that all plates and seals are present and legible,
if not contact the After-Sales Service.
✔The manufacturer shall not be liable for any damages caused by
incorrect handling of the terminal.
✔The information and illustrations contained in this manual were up to
date at the time of publication.
✔The manufacturer is committed to a policy of continuous product
improvement and parts of the system may therefore be subject to
modification.
✔All the technical information contained in this manual remains the
exclusive property of the manufacturer and may not be disclosed to
third parties.
✔No part of this document may be reproduced or transmitted in any
Venus
1-8

form, including publication in computerised form or on the World Wide
WEB, without the explicit written permission of the manufacturer.
✔This manual may not be used for purposes other than those directly
related to installation, operation and maintenance of the terminal.
✔In order to more clearly describe certain maintenance or adjustment
operations, some of the illustrations in this manual show the weighing
system with the safety guards removed. Under no circumstances may
the system be operated in these conditions. The safety guards may
only be removed for the time strictly required to carry out the required
repairs or maintenance work after which they must be fitted back in
place.
Venus
1-9

1.3 Symbols
Below is a list of the symbols used in this manual to alert the reader to
the various hazards associated with the operation and maintenance of
the instrument.
DANGER
Denotes an operation or procedure where failure to observe
the instructions will result in death or serious injury.
ATTENTION
Denotes an operation or procedure where failure to observe
the instructions could result in minor injury or damage to the
instrument.
WARNING
Information or instructions on how the system is to be
operated correctly in order to maximise its service life or
prevent loss or damage of programmed data or to optimise
operation with regard to metrological standards.
Text and messages displayed on the terminal are printed in this manual
using special characters.
Messages:
Display messages appear like this.
Menu pathways:
Home\Process\Data Modification\Product
The "\" character indicates the transition from one menu option to the
next.
Venus
1-10

1.4 Documentation
This manual is accompanied by a CD-ROM that primarily contains
information about installation of the terminal.
Here you will find information on how to interface the terminal with a PC
or PLC.
1.5 Description of the terminal
The digital weight indicator allows highly accurate and reliable weighing
operations to be carried out. Its field of use is mainly for commercial
weighing and labelling purposes. The graphic display and fully
alphanumerical keypad allow the terminal to be easily used by even
inexpert operators.
Certain of the characteristics of the indicator are listed below:
✔connection to up to 2 scales with analogue cells (up to four 350 Ohm
cells per scale)
✔three RS232/422/485 standard serial outputs
✔110-240 Vac power supply
✔facility for connection to an external keyboard and mouse (compatible
PCs).
Optional boards that extend the way the indicator is used and interfaced
can also be requested.
Venus
1-11

1.6 Technical characteristics of the terminal
Power supply: 110-240 +10%-15% Vac 50/60 Hz
Maximum power: 75 VA
Load cell connection: up to four 350 Ohm analogue cells
on the 9-pin connector for each
scale input
Minimum impedance: 87 ohm (per analogue input)
10 VdcAnalogue load cell power:
Resolution: up to 10000 divisions
23 mVMaximum input signal:
Sensitivity: 0.75 uV/division (version with
analogue cells)
Full scale stability: < 5 ppm/°C
Zero stability: < 5 ppm/°C
-10 + 40 °CCompensated temperature range: -10 +50 °COperating range:
Protection: IP20
Humidity: 85 % @ 40°C
Venus
1-12

1.7 Overall dimensions
Weight: 5.6 kg
The dimensions are given in mm.
Figure 1.1 - Overall dimensions and weight of terminal (citi5002.jpg)
1.8 Obtaining technical assistance
In the event of any operating faults requiring the intervention of
specialised technicians, contact the manufacturer or your nearest
Service Centre. To enable us to deal with your request swiftly, always
state the serial number of your terminal, which can be found on the seal
label. Also provide information about the system in which the terminal is
installed.
Venus
1-13

1.9 Replacement parts list
Description
Code
520540 110-240 Vac 50/60 Hz power supplier complete with
casing, fan, switch, fuses, socket and internal
connection flex
512739 Keyboard (policarbonate casing and board)
571312 Carrier E0202 board
571311 CPU 1220 board with Venus BIOS
460744 Scale converter complete with box
528242 LCD display
520539 Inverter for LCD display
460765 COMPACT Memory Card + Adapter
554749 D.O.M. Disk On Module 32Mb
460782 Parallel output kit
51270001 Keyboard (policarbonate casing and board) 8.2"
display version
52820001 8.2" sx21v001-z4 colour display for Venus
52050001 Inverter for 8.2" Venus LCD display
Replacement parts can be ordered directly from the manufacturer or
from your nearest Service Centre.
1.10 Warranty
The warranty conditions are specified in the contract of sale.
Venus
1-14

2. SAFETY INSTRUCTIONS
2.1 Prohibited uses
The instrument you have purchased is a weighing system and has been
designed and manufactured as such. The instrument is primarily
intended for weighing goods.
✔It is forbidden to use the terminal without taking the necessary
precautions for safe use.
✔Use of the terminal in places with potentially explosive atmospheres
or in areas where there is a risk of fire is strictly prohibited.
Any other use shall only be permitted if explicitly authorised by the
Manufacturer.
2.2 Regulations
The operating conditions for the electronic terminal are subject to the
regulations in force in the country in which the terminal is used. All use
of the terminal in conditions which do not comply with these regulations
is prohibited.
2.3 Prescriptions for use
✔Strictly comply with the instructions in this manual during use.
✔In the event of discrepancy between the information in this manual
and the instrument purchased, contact your Dealer or the
Manufacturer's After-Sales Service for explanations.
✔Always observe the indications given on the warning and danger
plates on the terminal.
✔Make sure that all the safety guards are in place and that the
connection cables are in a good condition and connected correctly.
✔Make sure that the terminal is connected to an electrical outlet socket
equipped with an efficient earth connection. Make sure that the line
complies with the applicable regulations. Make sure that there is no
difference in potential between the earth and neutral conductors.
✔If the terminal is to be connected to other devices (e.g. a computer or
other), these devices must be disconnected from the electricity main
before connection to the terminal.
Venus
1-15

✔All maintenance work and/or repairs must be carried out by
authorised personnel only.
✔Always disconnect the terminal from the electricity main and wait a
few minutes before accessing the internal components.
Venus
1-16

2.4 Professional profiles
In view of the absence of particular, intrinsically dangerous devices and
the consequent simplicity of the protection systems, the professional
profiles of the persons who work with the machine can be the following:
Qualification 1) Machine operator who is entrusted with operations that
include powering the line, starting, stopping, correctly feeding in the
products, unloading the products, replacing the labels and removing the
silicone-backed paper.
Qualification 1-a) Programmer of the machine entrusted with the
machine programming phase, which does not entail hazards for persons
or property. The person who deals with this task must be particularly
careful and diligent as some of the programming operations can destroy
the previously memorised data. He/she must also be familiar with the
productive organisation of the company so as to enter adequate
information.
Qualification 2) Mechanical servicing technician entrusted with making
sure that the mechanical components are clean and in a good condition,
as well as adjusting and servicing them: with the exclusion of any
operation involving the electrical system with which the machine is fitted.
Qualification 3) Servicing electrician, entrusted with the task of
organising the maintenance work and dealing with any electrical faults,
possibly with the ability to work inside the control panel.
Qualification 4) After-Sales Service, person who deals with all the
complex adjustments, servicing, repairs or other operations to be carried
out in particular conditions.
WARNING
Reference will be made to the qualifications described above
in all future descriptions about operations involving the
machine.
Venus
1-17

Venus
1-18

3. DELIVERY AND INSTALLATION
Key
1. Earthing screw
2. Data plate indicating the connection voltage and frequency ratings,
and the type of fuses
3. Threepole make power connector
4. Fuses
5. ON/OFF switch
Figure 3.1 - Rear part of terminal (power supplier part) (citi5003.jpg)
Venus
1-19

Key
1. 9-pin female connector (JCOM1) for serial connections to the
various devices
2. 9-pin female connector (JCOM2) for serial connections to the printer
3. 9-pin female connector (JCOM3) for serial connections to the
various devices
4. 9-pin male connector (JBIL-B) for connection to the second optional
weighing platform
5. 9-pin male connector (JBIL-A) for connection to the first weighing
platform
6. Expansion slot S4
7. Expansion slot S3
8. Expansion slot S2
9. Expansion slot S1
10. Slot for memory card
11. Supplementary keyboard-mouse input
12. Ethernet
Figure 3.2 - Rear part of terminal (part with scale connection and
auxiliary outputs) (citi5004.jpg)
Venus
1-20
Table of contents