—IMPORTANT
The Billi system is recommended to be
installed on a safe tray in accordance with
AS 3500.4 Clause 4.4.
—Determine component location
A stop tap (not supplied) is to be installed
in an easily accessible position for later
service. Determine the location of each
of the components, taking into account
the tube lengths and space available.
Refer to Diagrams 1 and 2.
—Flush lines
It is important to flush lines before fitting.
Install outlet fitting to combined valve. Refer
to Diagram 4 on the following page.
—Install dispenser tap assembly
—IMPORTANT
Dispenser must not be installed below the
spill level of the receiving fixture.
A 22mm hole is required either in the
benchtop or flat surface of sink adjacent
to bowl of sink. Mount the dispenser tap.
Refer to Diagram 3.
—Install chiller module
Connect all plastic tubing as shown.
Refer to Diagram 4.
All connections are made using push-fit
connectors. Trim tubes to correct lengths.
Tubes should be cleanly cut square using
a sharp knife or plastic tube cutter.
Ensure that tube ends are round and
not flattened or kinked, then push into
connectors firmly until properly seated (to
release, press the outer ring in while pulling
gently on the tube).
—Install drain connection
The Billi dispenser tap incorporates an air
break above the spill level of the sink and
therefore a tundish is not required.
Connect a 3/8” drain tube to dishwasher
nipple, or alternative drainage point, using
fittings supplied.
—IMPORTANT
Ensure drain tube has a continual fall.
—Turn on water supply
Lift dispenser tap lever and then turn on
water supply. After water flows from outlet,
release lever and ensure that there are no
leaks. Lift lever again and run for at least 5
minutes.
—Turn on electricity supply
—Set chilled water temperature
Set the desired water temperature using
blue temperature control knob.
Refer to B–3000 User Guide.
—Re-check connections for leaks
—Explain operation to user
Installing
procedure.