Bing Innovations DigiVibe User manual

Owner’s Booklet

3
The DigiVibe device is the latest product innovation from Bing
This Owner’s Booklet offers a complete explanation of how to use
to refer to it in the future.
We hope DigiVibe products will make it easier and more
TM

Ta bl e of contents
Intended Use + Kit Contents
Before You Begin
Setting Up the DigiVibe
Setting Up the Lancing Device
.
Ta k i ng a Te s t w it h Di g i Vi be
.
Removing the Used Lancet Device
Care and Maintenance of the Lancing Device
Care and Maintenance of the DigiVibe
Tro ub le sho ot in g & Tec hn ic al I nf or mat io n
Warnings
EMC
5
6
7
8
10
12
14
15
16
17
18
19
20
21
4

Intended Use + Kit Contents
Before You Begin
Setting Up the DigiVibe
Setting Up the Lancing Device
.
Ta k i ng a Te s t w it h Di g i Vi be
.
Removing the Used Lancet Device
Care and Maintenance of the Lancing Device
Care and Maintenance of the DigiVibe
Tro ub le sho ot in g & Tec hn ic al I nf or mat io n
Warnings
EMC
5
6
7
8
10
12
14
15
16
17
18
19
20
21
Biohazard After Use
Warning
Manufacturer
European Authorized Representative
Single Patient - Multiple Use
DigiVibe Symbols and Icons
Cautions and Warnings: Refer to all instructions and inserts that
Not Waterproof
5
Consult User Manual

Intended Use
6
5Te st s t ri p s to ra ge
1DigiVibe device and stand
2DigiVibe tip
3Lancing device
4
The DigiVibe is intended to be used during the
quantitative measurement of glucose (sugar) in fresh
The system is intended to be used by a
single patient and should not be shared.
Five 30-gauge lancets
6Glucose blood monitor storage
Kit contents

7
inserts that come with the DigiVibe device.
After use and exposure to blood, all parts of this kit are
performed cleaning and disinfection.
Clean and disinfect the DigiVibe before initial use and
once a week with cleaning and disinfecting wipes.
present a choking hazard.
Do not expose the unit to high temperatures for an
extended period of time (ex: leaving it in a vehicle
reduce the performance and/or cause a failure of the
disposable tip.
WARNING: Battery can explode or leak and cause
burns if installed backwards, dissembled, charged,
disassembly not allowed.
Before You Begin
IMPORTANT SAFETY INSTRUCTIONS:

1. Remove the DigiVibe
device and stand from
the travel case. Push tip
into handle until it clicks
into place.
compartment door, slide
the DigiVibe stand off
the device.
Familiarize yourself
with the device.
a.
b.
c.
d.
e.
f.
g.
8
b
a
d
c
g
f
eDigiVibe device
Power button
DigiVibe tip
Tip housing
DigiVibe stand
Suction activation button
Rubber suction base
Setting Up the DigiVibe

a
9
lining up the dot located
on the base of the tip to the
arrow on the device and
pushing the DigiVibe tip
hear a click.
Remove the DigiVibe tip
-
clockwise (1/4 turn) and
lifting up.
pressing the latch on
the bottom of the
DigiVibe. Remove the
protector.
compartment and slide
the DigiVibe stand onto
aligning the stand with
the grooves in the
DigiVibe and sliding
forward.

10
a
b
c
a
d
Before handling your lancing device, wash your hands
thoroughly with warm, soapy water. Rinse and dry completely.
Setting Up the Lancing Device
1. Remove the lancing
device
counterclockwise and then
pulling it straight up from
the device.
2. Insert a sterile lancet into
the grooves of the lancet
holder. Push the lancet into
seated in the holder. Twist
the protective cover one
full turn until it separates
from the lancet. Save the
protective cover for lancet
removal and disposal.
the device.
a. Lancing device cap
b. Depth indicator
c. Cocking control
d. Trigger

11
3. Replace the lancing
device cap back onto
clockwise to secure
the cap.
Do not over-tighten.
5. Cock the lancing
the device back until it
clicks. If it does not click,
inserted the lancet. The
lancing device is now
4. Adjust the depth setting
turning the wheel to
choose the depth from #1
(minimum depth) to #5
(maximum depth).
Shallower punctures work
for children and most
adults.

12
2. Attach the stand to
down with light pressure
against the surface and
pushing the suction
activation button at the
base of the stand until it
slides through to the
other side.
3. Be sure the Rubber
Suction Base and the
surface it is attaching to
are clean.
1. Place the DigiVibe
device with the stand at
surface with the
DigiVibe tip hanging
over the edge.
Taking a Test with the DigiVibe
Be sure your lancing device
and glucose monitor are ready
for use.

13
4. Press the power
button on the DigiVibe
device to turn it on.
against the vibrating
the vibrating tip for at
least 12 to 15 seconds
6. Position the lancet in
the center of the DigiVibe
to lose contact with the
vibrating tip until you
have pricked your

14
Removing the Used Lancet
1. Remove the lancing device cap
pulling it straight up from the device.
2. Cover the exposed lancet tip
Before removing the lancet, place the lancet protective
cover on a hard surface then push the lancet tip into the
cupped side of the cover.
3. Remove the lancet
After securing the tip of the lancet with its cover, remove
4. Replace the lancing device cap
secure the cap. Do not over-tighten. It is important to use
will help prevent infections.
5. Discard the used lancet
avoid unintended lancet stick injuries. Used lancets
care professional’s recommendations or local
regulations for proper disposal.
handling the DigiVibe, test strips, and lancing device
and cap.

15
Cleaning your DigiVibe and DigiVibe tip
1.
and then with a disinfecting wipe. DO NOT wet the DigiVibe
2.
then cleaning it with liquid detergent and rinsing with water.
DO NOT wet the DigiVibe device.
IMPORTANT:
sliding it downward and pressing the release latch.
.
Insert a new AA lithium batt
Replacing the battery
450 uses, assuming each use requires 15 seconds. If the
Battery
Care and Maintenance of the DigiVibe

16
The lancing device and cap should be disinfected at least once per
week.
2. Use a new germicidal wipe to rub or swab the outside of
the lancing device until the surface is damp.
DigiVibe and lancing device.
- Do not allow liquids, dirt, dust, blood, or control
lancing device.
- Do not immerse the DigiVibe or lancing device in
Care and Maintenance of the
Lancing Device
Replacing the battery (continued)
DigiVibe still does not power on, contact Customer Service at
1-844-503-8423.
Disposal of battery and Unit.
waste.

17
Troubleshooting
Detach the stand and wash with mild dish washing
Or, moisten the rubber suction cup prior to placing the stand on
DO NOT WET THE DEVICE.
2. DigiVibe vibration is weak.
batteries are not powerful enough to run the device at full
strength.
3. What if my DigiVibe will not turn on?
b. The device is built with a thermostat to ensure it
this occur, wait 5-10 minutes and the device will
4. What if my DigiVibe tip is cracked or damaged?
Customer Service at 1-844-503-8423 or order a
Technical Information

18
of defects in material and workmanship for a period of one
such a defect, Bing Innovations, LLC will, at its option, repair or
replace it without cost for parts and labor. The product must
be shipped, prepaid and insured (recommended), to an
authorized Bing Innovations, LLC Service Center. Proof of date
of original purchase is required. The cost to ship the product
nor does it cover damage resulting from accident, misuse, dirt,
ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE
YEAR FROM DATE OF ORIGINAL PURCHASE. IN NO EVENT
WILL BING INNOVATIONS, LLC BE RESPONSIBLE FOR
CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF
THIS PRODUCT. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the
Limited 1-Year Warranty

19
WARNING: Use of this equipment adjacent to or stacked with other
equipment should be avoided because it could result in improper
WARNING: Use of accessories, transducers and cables other than
could result in increased electromagnetic emissions or decreased
operation.
WARNING: Portable RF communications equipment (including
peripherals such as antenna cables and external antennas should be
Otherwise degradation of the performance of this equipment could
result.
The EMISSIONS characteristics of this equipment make it suitable for
use in industrial areas and hospitals (CISPR 11 Class A). If it is used in a
required) this equipment might not offer adequate protection to
mitigation measures, such as relocating or re-orienting the equipment.
In addition to the requirements of 7.9.3 of the general standard, the
technical description shall describe precautions to be taken to prevent
adverse events to the PATIENT and OPERATOR due to
ELECTROMAGNETIC DISTURBANCES
a:
The compliances for each EMISSIONS and IMMUNITY standard or test
and IMMUNITY TEST LEVEL.
Warning

20
User profile:
The lancing procedure is typically self-administered, i.e. the patient is
the user and the process is done at-home.
Contra indications:
User does not fit profile.
Device is used off label for other injections.
Device is used for multiple patients.
IP rating: This device has an IP21 rating, which means that it is resistant
to water being sprayed on it from the top only.
BF Symbol
Do not service the unit while equipment is in use.

21
EMC
Other manuals for DigiVibe
1
Table of contents
Other Bing Innovations Blood Glucose Meter manuals
Popular Blood Glucose Meter manuals by other brands

Arkray
Arkray GLUCOCARD 01-mini User instruction manual

All Medicus
All Medicus metene AGM-513S user manual

Bayer HealthCare
Bayer HealthCare Ascensia Contour CONTOUR Blood Glucose Meter and Ascensia CONTOURTM Test... user guide

GlucoZen.auto
GlucoZen.auto AGM-4000 user manual

Prodigy
Prodigy Pocket owner's manual

ReliOn
ReliOn Confirm User instruction manual